• Title/Summary/Keyword: radiation application

Search Result 1,449, Processing Time 0.024 seconds

Development of $^{166}Ho$-Stent for the Treatment of Esophageal Cancer (식도암 치료용 $^{166}Ho$-Stent 개발)

  • Park, Kyung-Bae;Kim, Young-Mi;Kim, Kyung-Hwa;Shin, Byung-Chul;Park, Woong-Woo;Han, Kwang-Hee;Chung, Young-Ju;Choi, Sang-Mu;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.62-73
    • /
    • 2000
  • Purpose: Esophageal cancer patients have a difficulty in the intake of meals through the blocked esophageal lumen, which is caused by an ingrowth of cancer cells and largely influences on the prognosis. It is reported that esophageal cancer has a very low survival rate due to the lack of nourishment and immunity as the result of this. In this study a new radioactive stent, which prevents tumor ingrowth and restenosis by additional radiation treatment, has been developed. Materials and Methods: Using ${\ulcorner}HANARO{\lrcorner}$ research reactor, the radioactive stent assembly ($^{166}Ho$-SA) was prepared by covering the metallic stent with a radioactive sleeve by means of a post-irradiation and pre-irradiation methods. Results: Scanning electron microscopy and autoradiography exhibited that the distribution of $^{165/166}Ho\;(NO_3)$ compounds in polyurethane matrix was homogeneous. A geometrical model of the esophagus considering its structural properties, was developed for the computer simulation of energy deposition to the esophageal wall. The dose distributions of $^{166}Ho$-stent were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly on the surface in the form of a cylinder with a diameter of 20 mm and length of 40 mm. As an animal experiment, when radioactive stent developed in this study was inserted into the esophagus of a Mongrel dog, tissue destruction and widening of the esophageal lumen were observed. Conclusion: We have developed a new radioactive stent comprising of a radioactive tubular sleeve covering the metallic stent, which emits homogeneous radiation. If it is inserted into the blocked or narrowed lumen, it can lead to local destruction of the tumor due to irradiation effect with dilatation resulting from self-expansion of the metallic property. Accordingly, it is expected that restenosis esophageal lumen by the continuous ingrowth and infiltration of cancer after insertion of our radioactive stent will be decreased remarkably.

  • PDF

Determination of Consistency according to the Status of Supplementary Education for Radiation Safety Management Managers (방사선안전관리책임자 보수교육의 현황에 따른 정합성 판단)

  • Seung-Chul Kim
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.7-12
    • /
    • 2024
  • Medical institutions wishing to install and operate diagnostic radiation generators must complete appointment training within one year of appointment based on the 「Medical Act」 and the 「Rules on Safety Management of Diagnostic Radiation Generator Devices」 which will come into effect on January 1, 2024. Additionally, You must receive supplementary education every three years from the date you received it. The strengthening of safety management for diagnostic radiation generators used in medical institutions means that although the radiation exposure that may occur when using diagnostic radiation generators is low, the risk of carcinogenesis may be higher than previously evaluated. In addition, safety management of diagnostic radiation generators can be said to be an essential requirement because it has been reported that the incidence of leukemia and other diseases is increasing in diagnostic radiation tests. However, the safety management training targets and programs for radiation exposure management operated by other organizations other than diagnostic radiation generators are significantly different. In addition, since the public institutions that are responsible for radiation safety management are divided, there is a risk of duplicative, excessive, and under-administrative application to medical institutions and educational institutions that install and operate diagnostic radiation generators. Therefore, we would like to determine their consistency by comparing domestic and foreign related cases and the provisions of the 「Medical Act」 and the 「Nuclear Safety Act」.

Two-Dimensional Electrophoresis Analysis of Proteins between Bacillus licheniformis DM3 and Its Antifungal Activity Deficient Mutant (이차원전기영동법을 이용한 길항세균 Bacillus licheniformis DM3와 이의 항진균 활성 결여 돌연변이균주간 단백질 비교 분석)

  • Lee, Young-Keun;Kim, Jae-Sung;Chung, Hye-Young;Jang, Yu-Sin;Jang, Byung-Il
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.3
    • /
    • pp.203-209
    • /
    • 2003
  • In the course of screening for antifungal agents, a bacterial strain, DM3 was isolated from a mud sample collected at Daechon in Chungnam province and identified as Bacillus licheniformis based on API 50CHB test. It has antifungal activity against 12 plant pathogenic fungi in paper disc assay. At the 95% lethal dose of gamma radiation ($^{60}Co$, 10 kGy, $D_{10}=2.32\;kGy$), the antifungal activity deficient mutant (mDM3) against Colletotrichum gloeosporioides was induced From 2-D electrophoresis analysis, serine hydroxymethyltransferase (45.0 kDa), hypothetical protein(40.7 kDa), NifU protein homolog(15.4 kDa), and resolvase(12.5 kDa) homologous proteins were detected only in B. licheniformis DM3. Lysozyme(18.1 kDa) and alkyl hydroperoxide reductase(15.6 kDa) homologous proteins were expressed uniquely in B. licheniformis mDM3. Further studies are needed to reveal that these proteins from B. licheniformis DM3 could be closely related to the antifungal activity against plant pathogenic fungi.

Effect of Salt Concentration on the Quality of SaewooJeot(Salted Shrimp) Fermented at Room Temperature (실온 저장 새우젓의 이화학적 미생물학적 특성에 미치는 염농도의 영향)

  • Oh Sang-Hee;Heo Ok-Soon;Shin Hyun-Soo;Lee Ju-Woon;Kim Dong-Ho;Byun Myung-Woo;Kim Mee-Ree
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.15 no.4
    • /
    • pp.444-449
    • /
    • 2005
  • Effect of salt concentration on the quality of Saewoojeot (salted shrimp) fermented at room temperature was evaluated Salted shrimp with three different salt concentration (9, 18 and $27\%$) were prepared with fresh shrimp, and fermented at $20^{\circ}C$ temperatures for 180 days. Amino nitrogen (AN), volatile basic nitrogen (VBN) and trimethylamine (TMA) contents increased with longer fermentation time and lower salt concentration. AN, VBN and TMA contents in salted and fermented shrimp with $9\%$ salt increased rapidly during fermentation period, while that with 18 and $27\%$ salt maintained its initial level through 180 days of fermentation. When salted and fermented shrimps were fermented at $20^{\circ}C$, all the indexes of fermentation process maintained stable with $27\%$ salt level. Pathogenic bacteria such as pathogenic Echerichia coli, Salmonella spp., were not detected in the manufactured salted and fermented shrimps. However, coliform and yeast disappeared within 180 days and 100 days of storage for 18 and $27\%$ salt, respectively. Gram positive cocci survived until 180 days of storage against $18\%$($10^3-10^6$ CFU/g) and $27\%$($0-10^6$ CFU/g) salt.

  • PDF

Radiation Synovectomy: when, which disease, and which joint (방사성 동위원소 활액막절제술의 임상응용)

  • Choi, Chang-Woon
    • 대한핵의학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.196-199
    • /
    • 1999
  • Radiation synovetomy with various radiopharmaceuticals has been used to alleviate pain and swelling of rheumatoid arthritis and related joint diseases for more than 40 years. It is an attractive alternative to the surgical synovectomy for the management of the various joint diseases. Recently, the development of new radiopharmaceuticals labeled with $^{90}Y,\;^{32}P,\;^{186}Re,\;^{188}Re,\;^{153}Sm,\;^{165}Dy$ and $^{166}Ho$, for the effective management of synovial inflammation and related arthritic problems are gaining attention. In this article the general concepts and the clinical application of radiation synovectomy are reviewed.

  • PDF

Analysis of Public Notice of NSSC and Field Application Case Regarding Security of Radioisotopes (원자력안전위원회 방사성동위원소 보안관련 고시 및 현장 적용 사례 분)

  • Lee, Hyun-Jin;Lee, Jin-Woo;Jeong, Gyo-Seong;Lee, Sang-bong;Kim, Chong-Yeal
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.303-310
    • /
    • 2018
  • Since Roentgen discovered X-rays, radiation sources have been utilized for many areas such as agriculture, industry, medicine and fundamental chemical research. As a result, human society has gained lots of benefits. However, if a radioactive material is used for the malicious purpose, it causes serious consequences to humanity and environment. Consequently, international organizations including International Atomic energy Agency (IAEA) have been emphasizing establishment and implementation of security management to prevent sabotage and illicit trafficking of radioactive materials. For this reason, the rule of technical standards of radiation safety management was revised and the public notice of security management regarding radioisotope was legislated in 2015 by Nuclear Safety and Security Commission (NSSC). Several radioactive sources which have to be regulated under the above rule and the public notice have been utilized in Advanced Radiation Technology Institute (ARTI) of Korea Atomic Energy Research Institute (KAERI). In order to control them properly, security management system such as access control and physical protection has been adapted since 2015. In this paper, we have analyzed the public notice of NSSC and its field application case. Based on the results, we are going to draw improvement on the public notice of NSSC and security system.

The Development of Automatic Chemical Processing System for $^{67}Ga$ Production ($^{67}Ga$ 생산용 화학처리 자동화 장치 개발)

  • Lee, Dong-Hoon;Kim, Yoon-Jong;Suh, Yong-Sup;Yang, Seung-Dae;Chun, Kwon-Soo;Hur, Min-Goo;Yun, Yong-Ki;Hong, Seung-Hong
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.25-33
    • /
    • 2003
  • The automatic system for $^{67}Ga$ production using for the diagnosis of malignant tumor has been developed. A solvent extraction and an ion exchange chromatography were used for the separation $^{67}Ga$ from the irradiated enriched $^{68}Zn$. This system consisted of a solvent separation unit which was composed of micro conductivity cells, air supply tubes, solvent transfer tubes, solenoid valves and glasses, a PLC based controller and a PMU user interface unit for automation. The radiation exposure to the workers and the production time can both be reduced by employing this system during the $^{67}Ga$ production phase. After all, the mass production of $^{67}Ga$ with high efficiency was possible.

PRACTICE SPECIFIC TRAINING FOR APPLICATION OF IONIZING RADIATION IN INDUSTRIES

  • Sdagopan, Geetha;Kim, Hyunkee
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.177-180
    • /
    • 2012
  • Industrial radiography practice is usually employed in public domain. Over the years there are several radiation accidents reported in this practice. The accidents often result in severe or fatal exposures to occupational workers and public. The number of radiation accidents is also significant when compared with other industrial accidents. This paper describes practice specific training as one of the measures to the improve radiation safety and reduce the accidents. The efforts by International Atomic Energy Agency (IAEA) to disseminate information and to improve the radiation safety status in industrial radiography are also discussed.

The Low-Radiation Dosimetry Application of "tris" Lyoluminescence using Electron Paramagnetic Resonance at Low Temperature

  • Son, Phil-Kook;Choi, Suk-Won;Kim, Sung-Soo;Gwag, Jin-Seog
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.172-175
    • /
    • 2012
  • We present a method for detecting very weak radiation by analyzing the inner structure of irradiated tris (lyoluminescence) materials using electron paramagnetic resonance (EPR) at low temperature. Organic materials have been looked into for use in emergency dosimetry of inhabitants around radiation accidents. However, this technology has never been applied to imperceptible radiation doses (< 0.5 Gy) because there is no proper method for detecting the change of inner structure of the subject bombed by very weak radiation at room temperature. Our results show that tris materials can be applied as a radiation detectors of very small radiation doses below 0.05 Gray, if EPR is used at low temperature (130 K ${\leq}$ T ${\leq}$ 270 K). The EPR signal intensity from the irradiated-tris sample had barely faded at all after 1 year.

Design of radiation detection circuit for gamma column scanning (자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계)

  • Kim, Jong-Beom;Jeong, Seong-Hui
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF