• Title/Summary/Keyword: radial distribution

Search Result 851, Processing Time 0.025 seconds

Distribution System Reconfiguration Using the PC Cluster based Parallel Adaptive Evolutionary Algorithm

  • Mun Kyeong-Jun;Lee Hwa-Seok;Park June Ho;Hwang Gi-Hyun;Yoon Yoo-Soo
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.269-279
    • /
    • 2005
  • This paper presents an application of the parallel Adaptive Evolutionary Algorithm (AEA) to search an optimal solution of a reconfiguration in distribution systems. The aim of the reconfiguration is to determine the appropriate switch position to be opened for loss minimization in radial distribution systems, which is a discrete optimization problem. This problem has many constraints and it is very difficult to find the optimal switch position because of its numerous local minima. In this investigation, a parallel AEA was developed for the reconfiguration of the distribution system. In parallel AEA, a genetic algorithm (GA) and an evolution strategy (ES) in an adaptive manner are used in order to combine the merits of two different evolutionary algorithms: the global search capability of GA and the local search capability of ES. In the reproduction procedure, proportions of the population by GA and ES are adaptively modulated according to the fitness. After AEA operations, the best solutions of AEA processors are transferred to the neighboring processors. For parallel computing, a PC-cluster system consisting of 8 PCs·was developed. Each PC employs the 2 GHz Pentium IV CPU, and is connected with others through switch based fast Ethernet. The new developed algorithm has been tested and is compared to distribution systems in the reference paper to verify the usefulness of the proposed method. From the simulation results, it is found that the proposed algorithm is efficient and robust for distribution system reconfiguration in terms of the solution quality, speedup, efficiency, and computation time.

A study of communication-based protection coordination for networked distribution system (네트워크 배전계통용 통신기반 보호협조에 관한 연구)

  • Kim, WooHyun;Chae, WooKyu;Hwang, SungWook;Lee, HakJu
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.43-48
    • /
    • 2022
  • Although the distribution system has been structured as complicated as a mesh in the past, the connection points for each line are always kept open, so that it is operated as a radial distribution system (RDS). For RDS, the line utilization rate is determined according to the maximum load on the line, and the utilization rate is usually kept low. In addition, when a fault occurs in the RDS, a power outage of about 3 to 5 minutes occurs until the fault section is separated, and the healthy section is transferred to another line. To improve the disadvantages of the RDS, research on the construction of a networked distribution system (NDS) that linking multiple lines is in progress. Compared to the RDS, the NDS has advantages such as increased facility utilization, load leveling, self-healing, increased capacity connected to distributed generator, and resolution of terminal voltage drop. However, when a fault occurs in the network distribution system, fault current can flow in from all connected lines, and the direction of fault current varies depending on the fault point, so a high-precision fault current direction determination method and high-speed communication are required. Therefore, in this paper, we propose an accurate fault current direction determination method by comparing the peak value polarity of the fault current in the event of a fault, and a communication-based protection coordination method using this method.

Distribution of Grown-in Defects in the Fast-pulled Czochralski-silicon Single Crystals (고속 인상 초크랄스키 실리콘 단결정에서 성장 결함 분포)

  • 박봉모;서경호;오현정;이홍우;유학도
    • Korean Journal of Crystallography
    • /
    • v.14 no.2
    • /
    • pp.84-92
    • /
    • 2003
  • The fast pulling is easy to modify the distribution of grown-in defects toward fine size, which can be readily removed by additional treatment. In this experiment, The fast pulled crystals with high pulling late over 1.0 mm/min were grown and their grown-in defect distributions were investigated. In our recent developments in the growth of Cz-Si, it could be found that the cooling rate in a specific temperature range and the uniformity of temperature gradient at solid/liquid interface are more important for the formation of grown-in defect than the pulling rate itself. We analyzed these cooling rates and temperature gradients for the various fast pulled crystals and compared them to the observed formation behavior of the grown-in defects. The effective factor (Ω) for the void defect formation was introduced and it could explain the radial distribution of void defects in the fast-pulled crystals effectively.

On the origin of blue straggler stars in dwarf galaxies

  • Kim, Hak-Sub;Han, Sang-Il;Joo, Seok-Joo;Yoon, Suk-Jin;Lee, Young-Wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.86.2-86.2
    • /
    • 2017
  • Blue stragglers (BSs) are the objects that are brighter and bluer than the stars at main-sequence turn-off point. In this study, we present the Ca-by and VI photometry for Galactic dwarf spheroidal galaxies using Subaru/Suprime-Cam and investigate the spatial distribution characteristics of BS stars using the hk index as a photometric metallicity indicator. We compare the cumulative radial distribution of the BS stars with those of two groups of red-giant-branch (RGB) stars divided by the hk-index strength, and find that the spatial distribution of all BS stars is closer to that of hk-weak (i.e. metal-poor) RGB stars. We also find that the hk-strong BS stars are more centrally concentrated than the hk-weak ones. We will discuss the use of hk-index as a metallicity indicator for the hot BS stars and suggest possible explanations for the results in terms of the origin of BS stars in the dwarf gal.

  • PDF

Analysis on Particle Deposition onto a Heated Rotating Disk with Electrostatic Effect (정전효과가 있는 가열 회전원판으로의 입자침착 해석)

  • 유경훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.424-432
    • /
    • 2002
  • Numerical analysis has been conducted to characterize deposition rates of aerosol particles onto a heated, rotating disk with electrostatic effect under the laminar flow field. The particle transport mechanisms considered were convection, Brownian diffusion, gravitational settling, thermophoresis and electrophoresis. The aerosol particles were assumed to have a Boltzmann charge distribution. The electric potential distribution needed to calculate local electric fields around the disk was calculated from the Laplace equation. The Coulomb, the image, the dielectrophoretic and the dipole-dipole forces acting on a charged particle near the conducting rotating disk were included in the analysis. The averaged particle deposition vetocities and their radial distributions on the upper surface of the disk were calculated from the particle concentration equation in a Eulerian frame of reference, along with a rotation speed of 0∼1,000rpm, a temperature difference of 0∼5K and a charged disk voltage of 0∼1000V.Finally, an approximate deposition velocity model for the rotating disk was suggested. The present numerical results showed relatively good agreement with the results of the present approximate model and the available experimental data.

A Measurements of Radio-Frequency Induction Discharge Plasma using probe method (고주파 유도방전 플라즈마의 푸로우브법에 의한 계측)

  • Park, Sung-Gun;Park, Sang-Yun;Ha, Chang-Ho;Park, Won-Zoo;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1657-1659
    • /
    • 1997
  • Electron temperature and electron density were measured in a radio-frequency inductively coupled plasma (RFICP) using a probe measurements. Measurement was conducted in an argon discharge for pressures from 10 [mTorr] to 40 [mTorr] and input rf power from 100 [W] to 800 [W], Ar flow rate from 5 [sccm] to 30 [sccm], Spatial distribution electron temperature and electron density were measured for discharge with same aspect ratio (R/L=2). Electron temperature and electron density were discovered depending on both pressure and power, Ar flow rate. Electron density was increased with increasing input power and in creasing pressure, increasing Ar flow rate. Radial distribution of the electron density was peaked in the plasma center. Normal distribution of the electron density was peaked in the center between quartz plate and substrate. From these results, We found out the generation mechanism of Radio-Frequency Inductively Coupled Plasma.

  • PDF

Spray Characteristics of Internal-Mixing Twin-Fluid Atomizer using Sonic Energy (음향에너지를 이용한 내부 혼합형 이유체 분사노즐의 분무특성)

  • Cho, H.K.;Kang, W.S.;Seok, J.K.;Lee, G.S.;Lee, C.W.
    • Journal of ILASS-Korea
    • /
    • v.4 no.3
    • /
    • pp.32-41
    • /
    • 1999
  • In this research, internal-mixing twin-fluid atomizer using sonic energy is designed and manufactured. We are trying to intimate high efficiency twin-fluid atomizer to obtain good liquid atomization in the low pressure region. Define of geometric form of atomizer, characteristics of spray is influenced by position, depth and height variation of cavity resonator, variation of sound intensity and resonant sound frequency with liquid flow rate. The liquid atomization is promoted by multi-stage disintegration of mixing flow of gas with liquid and the optimum condition of position and depth of cavity resonator according to sonic energy is obtained from the condition at a=2.5mm and L=2mm. The velocity distribution of droplets shows negative value due to recirculation region at the center of axial, and as the radial direction distance is far, the velocity distribution of droplets decrease slowly after having a maximum value. However velocity and SMD show nearly uniform distribution at the down stream and as result compared to Nukiyama and Tanasawa's equation. atomization of mixing flow with air and liquid dispersing from the outlet of the nozzle is promoted by the effect of collision at the cavity resonator.

  • PDF

Chemical Differentiation of CS and $N_2H^+$ in Starless Cores

  • Kim, Shinyoung;Lee, Chang Won;Sohn, Jungjoo;Kim, Gwanjeong;Kim, Mi-Ryang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.62.1-62.1
    • /
    • 2014
  • We present preliminary results on the chemical differentiation of two dense gas tracers CS and $N_2H^+$ in five 'evolved' starless cores, L1544, L1552, L1689B, L694-2 and L1197, using our mapping observations in $C^{34}S$(J=2-1) and $N_2H^+$(J=1-0) with Nobeyama 45-m telescope. We compared the intensity maps of two molecular lines with 850 ${\mu}m$ continuum data which precisely trace the density distribution of the dense cores, finding that all of our targets show the central depletion holes in CS distribution, but the similar distribution in $N_2H^+$ to the one in dust continuum. Our data confirm the claim that CS molecule generally deplete out in the central region in starless cores, while $N_2H^+$ keep abundant as they get evolved. The detailed quantitative analysis on CS depletion in the dense cores, for example, the size of CS depletion area and radial (or gas density) dependence of CS depletion, is underway and will be presented in the meeting.

  • PDF

On the Thermal Stress and Residual Stress Distributions in a Aluminum Alloy Plate due to Resistance Spot Welding (알루미늄합금(合金)의 저항용접(抵抗熔接)에 따른 열응력(熱應力) 및 잔류응력(殘留應力)의 해석(解析))

  • Zae-Geun,Kim;Hyo-Chul,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.9 no.2
    • /
    • pp.21-32
    • /
    • 1972
  • The problems of thermal stress and residual stress in resistance spot welding are studied from two standpoint namely, effect of temperature distributions and effect of the radius of free boundary. The radius of the region where the temperature distributions are occured is taken as a function of time after welding and as a finite size, 6 times of heated zone. The region of the radial stress distribution is treated as a function of time under Saint-Venant's principle and 6 or 12 times of originally heated zone. Thermal stresses and strains are obtained by analytic solution under constant mechanical properties and by the finite difference method for varing properties under temperature variation. From the computed results following conclusions are derived (1) For the engineering purpose, the region of temperature distribution and stress distribution can be treated as a finite region, $R=r_o=6r_e$ (2) If the maximum temperature of the aluminum alloy plate is less than $500^{\circ}F$, thermal stresses and strains can be obtained with constant mechanical properties. (3) The residual stresses and strains will be remained in welds and its vicinity.

  • PDF

Modeling and Investigation of Multilayer Piezoelectric Transformer with a Central Hole for Heat Dissipation

  • Thang, Vo Viet;Kim, In-Sung;Jeong, Soon-Jong;Kim, Min-Soo;Song, Jae-Sung
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.671-676
    • /
    • 2011
  • A multilayer square-type piezoelectric transformer with a hole at the center was investigated in this paper. Temperature distribution at the center was improved by using this construction, therefore increasing input voltage and output power. This model was simulated and investigated successfully by applying a finite element method (FEM) in ATILA software. An optimized structure was then fabricated, examined, and compared to the simulation results. Electrical characteristics, including output voltage and output power, were measured at different load resistances. The temperature distribution was also monitored using an infrared camera. The piezoelectric transformer operated at first radial vibration mode and a frequency area of 70 kHz. The 16 W output power was achieved in a three-layer transformer with 96% efficiency and $20^{\circ}C$ temperature rise from room temperature under 115 V driving voltage, 100 ${\Omega}$ matching load, $28{\times}28{\times}1.8mm$ size, and 2 mm hole diameter. With these square-type multilayer piezoelectric transformers, the temperature was concentrated around the hole and lower than in piezoelectric transformers without a hole.