• Title/Summary/Keyword: quasi-steady

Search Result 322, Processing Time 0.023 seconds

An experimental study of heat transfer and particle deposition during the outside vapor deposition process (외부증착공정(OVD)에서 열전달 및 입자부착에 관한 실험적 연구)

  • ;;Kim, Jaeyun;Choi, Mansoo
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.11
    • /
    • pp.3063-3071
    • /
    • 1995
  • An experimental study has been carried out for the heat transfer and particle deposition during the Outside Vapor Deposition process. The surface temperatures of deposited layers, and the rates, efficiencies and porosities of particle deposition were measured. It is shown that the axial variation of the surface temperature can be assumed to be quasi-steady and that as the traversing speed of burner is increased, the deposition rate, efficiency and porosity increase due to the decreased surface temperature. As the flow rate of the chemicals is increased, both the thickness of deposition layers and the surface temperature increase. Deposition rate also increases, however, deposition efficiency decreases for tests done. Later passes in early deposition stage result in higher surface temperatures due to increased thickness of porous deposited layers, which cause the deposition rate, efficiency, and porosity to decrease.

Enzyme Kinetics of Multiple Inhibition in the Presence of Two Reversible Inhibitors

  • Han, Moon H.;Seong, Baik L.
    • Bulletin of the Korean Chemical Society
    • /
    • v.3 no.3
    • /
    • pp.122-129
    • /
    • 1982
  • In order to extend our understanding on the multiple inhibition enzyme kinetics, a general equation of an enzyme reaction in the presence of two different reversible inhibitors was derived by what we call "match-box mechanism" under the combined assumption of steady-state and quasi-equilibrium for inhibitor binding. Graphical methods were proposed to analyze the multiple inhibition of an enzyme by any given sets of different inhibitors, i.e., competitive, noncompetitive, and uncompetitive inhibitors. This method not only gives an interaction factor $({\alpha})$ between two inhibitors, but also discerns ${\alpha}_1$ and ${\alpha}_2$ with and without substrate binding, respectively. The factors involved in the dissociation constants of inhibitors can also be evaluated by the present plot. It is also shown that the present kinetic approach can be extended to other forms of activators or hydrogen ions with some modification.

Characteristics and Dynamic Compensation Modeling of Liquid-Based Tilt Sensor (액체저항경사계의 특성과 동적모델링)

  • Song, Mu-Seok;Ahn, Ja-Il
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.2 s.140
    • /
    • pp.73-79
    • /
    • 2005
  • The characteristics of a tilt sensor utilizing the resistance change of an electrolyte associated with inclination is investigated, and a dynamic compensation modeling is proposed to make the real-time measurement of the absolute slope possible even with sporadically dynamic motion. Although the proposed system is small, economical and accurate for quasi-steady slope measurement, since it contains a freesurface the evolution of the liquid surface that has no direct relation to the real slope must be excluded for any rapid rotations or translations. For various artificial motions the response of the sensor is analyzed and simplified modeling equations are proposed.

Simulation of Transient Flow in a Cold-Water Supply System with Pressure Reducing Valves for Cooling the Inside of a Coal Mining Pit (감압밸브를 사용한 탄광갱내 공조용 냉수 공급시스템의 과도현상 해석)

  • Kang, S.H.;Lee, T.S.;Lee, S.S.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.395-407
    • /
    • 1988
  • Transient flow in a cold-water supply system for cooling the inside of a coal mining pit was numerically simulated. Properly designed and presetted pressure reducing valves control the level of pressures of the piping system at normal or emergent conditions Quasi-steady relations to simulate the valve motion are obtained and the transient performance of the valve is investigated in the present paper. The present method reasonably simulate transient phenomena in the system including the pressure reducing valve. Excessive valve motion and column separation are simulated when the flow is abruptly reduced. A calculated example of the real system is also presented. The simulation can be used for the safety-check and the guidance for design and operation in emergent cases of the system.

  • PDF

A Study on Switching Characteristics of Active Clamp Type Flyback Converter with Synchronous Rectifier Driving Signals Controlling Auxiliary Switch (보조스위치가 동기정류기 구동 신호로 제어되는 능동 클램프형 플라이백 컨버터의 스위칭 특성에 관한 연구)

  • Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.3
    • /
    • pp.21-26
    • /
    • 2018
  • In this paper, the switching characteristics of the active clamp type flyback converter, which is deemed suitable for the miniaturization of the external power supply for home appliance, were analyzed and the process of reducing the switching loss was explained. The active clamp type flyback converter operating in the DCM has confirmed that the surge voltage of the main switch does not occur and the turn-off / on loss of the switch do not occur in principle. Also, in the case of the switch for synchronous rectifier, it was showed that the switch current showed half-wave rectified sinusoidal characteristic, and the switching loss was reduced. The switching characteristics of the experimental results gathered from 120 W class prototype were compared with the theoretical waveform in the steady-state and it was confirmed that the power conversion efficiency of the active clamp type flyback converter was maintained high due to the reduction of the switching loss.

Analytical Solution of Two -dimensional Conduction in the Side Wall of a Thermocline System Enclosure (Thermocline 축열조 측벽에서의 열전도 해석)

  • Lee Joon Sik
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.1
    • /
    • pp.103-108
    • /
    • 1987
  • The heat transfer processes taking place in the side wall of a thermocline enclosure have been analyzed for idealized conditions based on the assumption that, at any instant time, side wall heat transfer processses are independent of the thermocline bulk motion. However, the axial tempera-ture distribution in the thermocline core provides the means for specifying the liquid medium-side boundary condition to the enclosure side wall. A picture is drawn which reflects the side wan response to thermocline bulk motion within the frame work of a quasi-steady analytic approach. For valves of the parameters typical of systems of engineering interest, the analysis shows that a significant amount of heat transfer short - circuiting can take place along the side wall enclosure. This phenomenon is favored by high values of $H_l$ and low values of P and $H_g$ respec-tively. The location of the point of zero normal heat flux on the side wan can be expected to mark, approximately, the region of confluence of two sidewall boundary flows respectively driven by the buoyant effects.

  • PDF

Heat Transfer from a Sphere in Fluctuating Flow (맥동류에 놓인 구로부터의 열전달)

  • Kwon Young-Pil;Lee Kye-Cheul
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.2
    • /
    • pp.185-193
    • /
    • 1987
  • The heat transfer characteristics from a solid sphere in a fluctuating air flow is simulated numerically in the range of the Reynolds numbers, $1\;{\leqslant}\;Re\;{\leqslant}\;40.$ Such a situation may be encountered in forced convection from a heated spherical particle in a sound field or oscillat-ing flow. The amplitude and phase delay in the heat transfer response to the flow oscillation are computed for a small amplitude flow. The instantaneous response of heat transfer is simulated for the large amplitude oscillation and compared with the quasi-steady response. The effect of the oscillation on the time - mean value in the local and overall heat transfer rate is discussed along with the change in the flow .field.

  • PDF

Estimation of Overflow-Induced Pressure and Velocity on a Mound-Type Sea Dike (월류 시 마운드형태 방조제에 작용하는 압력과 유속 산정)

  • Kim, Taehyung;Yeh, Harry;Kim, Sungwoung;Choi, Myoungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.3
    • /
    • pp.5-13
    • /
    • 2015
  • Wave overflow can cause a failure of sea dike structure. Based on the results of the field surveys on mound-type sea dike, the failure of vicinity of crown and the scouring of toe at the landward was revealed as the most representative failure example. One of the main factors related to this failure pattern is overflow-induced pressure and velocity. Thus, in this study the analytical equations which can determine the pressure and the velocity induced by overflow in sea dike were proposed and verified. To accomplish this, assumed that the flow is quasi-steady and irrotational, and concentric circular streamlines around the vicinity of crown and toe of the sea dike. Flow was assumed as critical state and Bernoulli equation was used to develop the equations that can determine the pressure and velocity at the vicinity of crown and toe of the sea dike. Using these equations, the pressure and the velocity were calculated in condition of various overflow depths and radiuses of circular streamline. Based on the calculation results, while a negative pressure was occurred at the vicinity of crown, a significant amount of positive pressure occurred at the toe. The existence of flow-induced shear stresses was also confirmed. In addition, the limitation of the proposed equations was discussed.

A study on grid aspect ratio of fire dynamics simulator (FDS의 격자 종횡비에 관한 연구)

  • Kim, Won Ouk;Park, Woe-Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.923-928
    • /
    • 2015
  • The FDS is one of the most used programs for fire analysis and needs an optimal grid selection for an accurate analysis. This study selected various grid aspect ratios (ARs) for selection of optimal grid and analyzed them with FDS v 6.1.2. A calculation time of 10 min. was used, which is enough to obtain the time average value of temperature changes. Temperature, visibility, and the time average value of mass balance are obtained from 200-600 s, which is a period of maintaining quasi-steady state. Two polyurethane fires of 1 [MW] and 2 [MW] in two enclosures of $10{\times}10{\times}3[m^3]$ and $20{\times}20{\times}3[m^3]$ were considered. Time variations of heat release rates, temperature, visibility, and mass balance were compared for ARs from 1-6. The heat release rates were accurate for all aspect ratios regardless of fire and enclosure sizes. The quasi-steady state temperature and visibility were well predicted for $AR{\leq}5$. Temperature drop and skewness of mass conservation, however, increased with increasing aspect ratio. Therefore, careful investigation of the grid size is recommended in performance-based design when $AR{\geq}3$, where temperature and visibility in early stage of a fire are important parameters. For accurate simulations of enclosure fires, grid sizes of 0.1~0.2 [m] and smaller in the vertical direction and $AR{\leq}2$ are recommended.

ATTITUDE STABILITY OF A SPACECRAFT WITH SLOSH MASS SUBJECT TO PARAMETRIC EXCITATION (계수자극을 받는 유동체를 포함한 위성체의 자세 안정도 해석)

  • Kang, Ja-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.3
    • /
    • pp.205-216
    • /
    • 2003
  • The attitude motion of a spin-stabilized, upper-stage spacecraft is investigated based on a two-body model, consisting of a symmetric body, representing the spacecraft, and a spherical pendulum, representing the liquid slag pool entrapped in the aft section of the rocket motor. Exact time-varying nonlinear equations are derived and used to eliminate the drawbacks of conventional linear models. To study the stability of the spacecraft's attitude motion, both the spacecraft and pendulum are assumed to be in states of steady spin about the symmetry axis of the spacecraft and the coupled time-varying nonlinear equation of the pendulum is simplified. A quasi-stationary solution to that equation and approximate resonance conditions are determined in terms of the system parameters. The analysis shows that the pendulum is subject to a combination of parametric and external-type excitation by the main body and that energy from the excited pendulum is fed into the main body to develop the coning instability. In this paper, numerical examples are presented to explain the mechanism of the coning angle growth and how angular momenta and disturbance moments are generated.