• Title/Summary/Keyword: quantitative evaluation method

Search Result 1,410, Processing Time 0.027 seconds

A comparative analysis of the simulation results of total window thermal transmittance(Uw) according to the evaluation method - Focused on comparison of the single window simulation results - (창세트 전체 열관류율(Uw) 평가 방법에 따른 시뮬레이션 결과 비교 분석 - 단창 창세트에 대한 시뮬레이션 결과 비교를 중심으로 -)

  • Lee, Yong-jun;Oh, Eun-joo;Kim, Sa-kyum;Choi, Hyun-jung;Kim, Yu-min
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.77-82
    • /
    • 2016
  • Purpose: The aim of this study is to calculate U-factor of the window using international standard methods and compare quantitative and tendency difference focused on ISO standard 15099 and ISO standard 10077. And the result of ISO standard calculation methods is verified using thermal performance experiment to evaluate applicability of domestic certification system. This study is utilized a basis for activation of domestic window certification system. Method: First, 16 cases are selected that is combined a variety of frame, Glazing, spacer, etc. The selected cases were simulated using WINDOW&THERM based on ISO 15099 and 10077 calculation method. Second, experiment was conducted based on Korean standard condition. Then, it was compared the error of experiment and simulation results. Through this process, ISO 15099 and 10077 calculation methods were evaluated accuracy and utilization. Result: The results show that the difference of ISO 15099 and ISO 10077-2 is maximum 5.4%. The results of comparing U-factor errors based on the Korea standard experiment test found 2.4%. Consequently, it will be possible to combination calculation methods of ISO 15099 and ISO 10077 for a single window.

An Evaluation of the Statistical Techniques Used in Papers of the Journal of Sasang Constitutional Medicine (2000-2009) (최근 10년간(2000-2009) 사상체질의학회지 게재논문의 통계분석방법에 대한 연구)

  • Park, Ki-Hyun;Kim, Sang-Hyuk;Kim, Hong-Gie;Lee, Si-Woo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.22 no.4
    • /
    • pp.49-55
    • /
    • 2010
  • 1. Objectives The purpose of this study is to assess the statistical methods used in the Journal of Sasang Constitutional Medicine and to identify the types of errors in the statistical analysis. 2. Methods We have reviewed quantitative articles published in the Journal of Sasang Constitutional Medicine from 2000 to 2009. Except for the case report, a total of 505 articles was reviewed by year. We focused on the methods of statistics in these articles. We have analysed the number of thesis used the statistical methods, the number of the statistical methods, the types of the statistical methods, and the errors of the statistical methods with the object of 202 thesis used the statistical method. 3. Results 1. Of the 370 articles, 202 used inferential statistics. 2. The most dominant was the thesis with one type of the statistical method forming 61.9% (125 thesis) of the total. 3. The ANOVA was the statistic of choice overall (40.1%), followed by the t-test (35.6%). 4. By examining the errors of the statistical methods, there were 49 thesis with errors among 81 thesis using ANOVA, 25 thesis among 72 thesis using t-test, and 18 over 62 thesis using chi-squared test. 4. Conclusions We have found various mistakes or misuses in the applications of statistical methodologies in the articles published in the Journal of Sasang Constitutional Medicine. It is necessary to present the cases of inappropriate statistical methods in order to improve the quality of academic researches. So long as Sasang constitutional medicine uses the statistical methods, researchers should fully examine and be aware of the statistical methods which they wish to use through other research articles, and statistic publications.

3D Head Modeling using Depth Sensor

  • Song, Eungyeol;Choi, Jaesung;Jeon, Taejae;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.13-16
    • /
    • 2015
  • Purpose We conducted a study on the reconstruction of the head's shape in 3D using the ToF depth sensor. A time-of-flight camera (ToF camera) is a range imaging camera system that resolves distance based on the known speed of light, measuring the time-of-flight of a light signal between the camera and the subject for each point of the image. The above method is the safest way of measuring the head shape of plagiocephaly patients in 3D. The texture, appearance and size of the head were reconstructed from the measured data and we used the SDF method for a precise reconstruction. Materials and Methods To generate a precise model, mesh was generated by using Marching cube and SDF. Results The ground truth was determined by measuring 10 people of experiment participants for 3 times repetitively and the created 3D model of the same part from this experiment was measured as well. Measurement of actual head circumference and the reconstructed model were made according to the layer 3 standard and measurement errors were also calculated. As a result, we were able to gain exact results with an average error of 0.9 cm, standard deviation of 0.9, min: 0.2 and max: 1.4. Conclusion The suggested method was able to complete the 3D model by minimizing errors. This model is very effective in terms of quantitative and objective evaluation. However, measurement range somewhat lacks 3D information for the manufacture of protective helmets, as measurements were made according to the layer 3 standard. As a result, measurement range will need to be widened to facilitate production of more precise and perfectively protective helmets by conducting scans on all head circumferences in the future.

Evaluation of the Corrosion Resistance of Plated Ni and Ni-Cr Layers on Fe Substrate by Using Salt Spray, CASS and EC Tests (철소지 위에 형성된 니켈 및 니켈-크롬 도금층의 염수분무, 캐스, 전해부식시험법을 이용한 내식성평가)

  • 신재호;이동훈;이재봉;신성호
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.4
    • /
    • pp.307-316
    • /
    • 2003
  • Salt spray, CASS(copper accelerated acetic salt spray) and EC(electrolytic corrosion) tests were performed in order to evaluate the corrosion resistance of plated Ni and Ni-Cr layers on Fe substrate. Compared with the conventional methods such as salt spray and CASS, the electrochemical method such as EC test may be beneficial in terms of test time span and quantitative accuracy. Furthermore, EC test can also become the alternative method to evaluate the resistance to corrosion of coatings by measuring the corrosion potentials of the coated layers in the electrolyte during the off-time of EC cycles. Compared with the corrosion potentials of pure iron, nickel, chromium, those potentials of coated layers can be used to anticipate the extent of corrosion. Results showed that in terms of the test time span, EC test gave 14 times and 21 times faster results than the salt spray test in cases of $5\mu\textrm{m}$ Ni and $20\mu\textrm{m}$ Ni plated layers, respectively. In addition, EC test also offered the shorter test time span than CASS test in cases of $5 \mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr, and $20\mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr on Fe substrate by 78 times and 182 times, respectively. Therefore, EC test can be regarded as the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as salt spray and CASS.

Lifecycle and Requirements for Digital Collection Management of Thai Theses and Dissertations

  • Jareonruen, Yuttana;Tuamsuk, Kulthida
    • Journal of Information Science Theory and Practice
    • /
    • v.7 no.3
    • /
    • pp.52-64
    • /
    • 2019
  • This research was aimed at studying the situation, problems, and requirements for digital collection lifecycle management of Thai theses and dissertations. The mixed research method used was composed of: (1) Study of the problem and situation in which the qualitative method was applied. The research site covered 10 higher education institutions where the Thailand Digital Collection (TDC) project is operated. The informants were key administrative officers of the TDC project of each institution. In-depth and structured interviews were conducted on an individual basis to obtain the most accurate answers. (2) Study of requirements based on the quantitative research method to survey the requirements for the digital collection management system for Thai theses and dissertations from 84 purposively-selected TDC project officers and 527 end users selected by accidental sampling, totaling 611 samples. Research findings are as follow: (1) The study of the situation and problems of digital collection lifecycle management shows that Thai higher institutions systematically manage their digital collection. The management lifecycle is consistent with the Guidance documents for lifecycle management of ETDs, which included seven steps: program planning, creation, submission, and ingestion, access and retrieval of digital objects, archiving and preservation, evaluation and assessment, interoperation (creation of institutional collaboration), and development of link data. (2) The study of requirements for digital collection management of Thai theses and dissertations shows five system requirements: acquisition and gathering, digitization, metadata standards, management of rights, and storage and retrieval, all of which are at M (mandatory) and D (desirable) levels.

Comparison of Modulation Transfer Function in Measurements by Using Edge Device angle in Indirect Digital Radiography (간접평판형 검출기에서 변조전달함수 측정 시 Edge 각도에 따른 비교 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.259-263
    • /
    • 2019
  • This study was purpose to compare image quality of Indirect digital radiography (IDR) system by using the International electro-technical commission standard(IEC 62220-1) which were applied to IEC in medical imaging. To evaluation the analysis of Modulation transfer function(MTF) measurements edge device each angle by using edge method. In this study, Aero (Konica, Japan) which is Indirect flat panel detector(FPD) was used, the size of image receptor matrix $1994{\times}2430$ which performed 12bit processing and pixel pitch is $175{\mu}m$. In IEC standard method were applied to each angle were compared. The results of shown as LSF at $2.0^{\circ}$ and $3.0^{\circ}$ angeles. Shape is constant and shows smooth shape. The amount of data seemed reasonable and 2.19 cycles/mm and 2.01 cycles/mm at a spatial frequency of $2.0^{\circ}$ and $3.0^{\circ}$ at an MTF value of 0.1. At an MTF value of 0.5, the spatial frequencies were $2.0^{\circ}$ and 1.11 cycles/mm and 0.93 cycles/mm at an angle of $3.0^{\circ}$. This study were to evaluate MTF by setting the each $2{\sim}3^{\circ}$ each angle and to suggest the quantitative methods of measuring by using IEC.

Evaluation of the Feasibility of the Sample Pretreatment and Nile Red Fluorescence Staining Methods for Quantification of Microplastics in Wastewater Samples (하수처리장 유입⋅유출⋅공정수 내 미세플라스틱 분석을 위한 시료 전처리 기법과 Nile Red 형광염색법 적용성 평가)

  • Jae In Kim;Nguyen Thu Huong;Byung Joon Lee
    • Journal of Korean Society on Water Environment
    • /
    • v.40 no.1
    • /
    • pp.36-46
    • /
    • 2024
  • Microplastics in water resources have been recognized as a serious problem. The discharge of microplastics from wastewater treatment plants is considered a major contributor to environmental pollution in water resources. However, a reliable analytical method for quantifying microplastics in wastewater treatment plants has not yet been established. This study proposes a reliable, quick, and easy analytical method for quantifying microplastics. For the removal of organic particles, preprocessing steps were applied including oxidation, sonication, washing, and sieving. Nile Red staining was used to visualize microplastics, and quantitative analysis was conducted using fluorescent imaging. The stained microplastics were ultimately quantified through image analysis software. Among the preprocessing steps, sonication and washing stages were particularly effective in efficiently removing interfering substances from wastewater, enhancing the accuracy of the microplastic analysis. Additionally, various solvents (methanol, acetone, and N-hexane) for the Nile Red staining solution were tested. When N-hexane was applied as the solvent, the quantity of stained microplastics was lower compared to methanol and acetone. This suggests that N-hexane has a greater potential of reducing false staining and counting of non-plastic particles. In summary, this research demonstrates a robust method for quantifying microplastics in wastewater treatment plants by employing effective preprocessing steps and optimizing the staining process with Nile Red and N-hexane.

Cytotoxicity test on human contact area with L-929 cells using extracorporeal shock wave therapy cartridge (체외충격파치료기 카트리지의 L-929 세포를 통한 인체접촉부의 세포독성시험)

  • Jun-tae Kim;Se-jin Yoon;So-hyun Park;Kyung-ah Kim;Jae-hyun Jo;Jin-hyoung Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.5
    • /
    • pp.389-395
    • /
    • 2024
  • This study was conducted to determine the cytotoxicity of the extracts from the human body contact area of the test substance during a test on the Good Laboratory Practice (GLP), which is the medical device safety evaluation standard, using the extracorporeal shock wave therapy (ESWT) cartridge as a sample, using L-929 cells. The test and control substances were extracted with 1xMEM culture medium containing 10% FBS at 37±1℃ for 24±2 hours. The test substance extract (test group), negative control substance extract (negative control group), positive control substance extract (positive control group), and blank test solution extract (solvent control group) were applied to L929 cells and cultured for 48±2 hours in a 37±1℃, 5±1% CO2 incubator. As a result of observing cell reactions under a microscope, the cells to which the blank test solution extract and negative control substance extract were applied were grade 0, the cells to which the positive control substance extract was applied were grade 4, and the cells to which the test substance extract was applied were grade 0. As a result of quantitative evaluation through cell counting, the cell viability rate of the cells to which the negative control substance extract was applied was 106.28% compared to the blank test solution extract, the cells to which the positive control substance extract was applied were 0.00%, and the cells to which the test substance extract was applied were 99.58%. Therefore, when the results of the negative and positive control groups were confirmed, the test process was appropriate, and it was determined that it did not cause cytotoxicity because the qualitative evaluation method was less than grade 2 and the quantitative evaluation method showed a cell viability rate of more than 70%.

Quantitative Rainfall Estimation for S-band Dual Polarization Radar using Distributed Specific Differential Phase (분포형 비차등위상차를 이용한 S-밴드 이중편파레이더의 정량적 강우 추정)

  • Lee, Keon-Haeng;Lim, Sanghun;Jang, Bong-Joo;Lee, Dong-Ryul
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.1
    • /
    • pp.57-67
    • /
    • 2015
  • One of main benefits of a dual polarization radar is improvement of quantitative rainfall estimation. In this paper, performance of two representative rainfall estimation methods for a dual polarization radar, JPOLE and CSU algorithms, have been compared by using data from a MOLIT S-band dual polarization radar. In addition, this paper presents evaluation of specific differential phase ($K_{dp}$) retrieval algorithm proposed by Lim et al. (2013). Current $K_{dp}$ retrieval methods are based on range filtering technique or regression analysis. However, these methods can result in underestimating peak $K_{dp}$ or negative values in convective regions, and fluctuated $K_{dp}$ in low rain rate regions. To resolve these problems, this study applied the $K_{dp}$ distribution method suggested by Lim et al. (2013) and evaluated by adopting new $K_{dp}$ to JPOLE and CSU algorithms. Data were obtained from the Mt. Biseul radar of MOLIT for two rainfall events in 2012. Results of evaluation showed improvement of the peak $K_{dp}$ and did not show fluctuation and negative $K_{dp}$ values. Also, in heavy rain (daily rainfall > 80 mm), accumulated daily rainfall using new $K_{dp}$ was closer to AWS observation data than that using legacy $K_{dp}$, but in light rain(daily rainfall < 80mm), improvement was insignificant, because $K_{dp}$ is used mostly in case of heavy rain rate of quantitative rainfall estimation algorithm.

Isolation, Quality Evaluation, and Seasonal Changes of Bakkenolide B in Petasites japonicus by HPLC (머위로부터 Bakkenolide B의 순수분리, HPLC분석 방법 및 채취 시기별 함량 분석)

  • Kim, Tae Hoon;Kim, Do Youn;Jung, Won Jung;Nagaiya, Ravichandran;Son, Beung Gu;Park, Young Hoon;Kang, Jum Soon;Lee, Young Jae;Im, Dong-Soon;Lee, Young-Geun;Choi, Yung Hyun;Choi, Young-Whan
    • Journal of Life Science
    • /
    • v.24 no.3
    • /
    • pp.252-259
    • /
    • 2014
  • The leaves of Peatasites japonicus are a traditional oriental medicine with diverse biological activities. A simple and specific analytical method for the quantitative determination of bakkenolide B constituents from methanolic extract of the leaves of P. japonicus was developed. Bakkenolide B was isolated from the leaves of P. japonicus, and its structure was elucidated based on 1D, 2D NMR, and GC-MS spectral data. A liquid chromatographic method was developed to evaluate the quality of P. japonicus through determination of major active compound, bakkenolide B. The wavelengths at 254 and 215 nm were chosen to determine bakkenolide B. The recovery of the method was in the range of 98.6 to 103.1%, and bakkenolide B showed good linearity ($r^2$=0.999) within test ranges. The developed method was applied to the determination of bakkenolide B in the plant part and seasonal changes. The results showed that the content of bakkenolide B in the leaf was higher than in the petiole and rhizome. In this study, a simple, rapid, and reliable high-performance liquid chromatography method was used to determine the percentage and composition of bakkenolide B in P. japonicus procured from different Petasites species plants in South Korea. The method can be employed in routine quantitative analysis and quality control of different products in the market.