• Title/Summary/Keyword: quantitative evaluation method

Search Result 1,410, Processing Time 0.032 seconds

A Failure Estimation Method of Steel Pipe Elbows under In-plane Cyclic Loading

  • Jeon, Bub-Gyu;Kim, Sung-Wan;Choi, Hyoung-Suk;Park, Dong-Uk;Kim, Nam-Sik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.245-253
    • /
    • 2017
  • The relative displacement of a piping system installed between isolated and nonisolated structures in a severe earthquake might be larger when without a seismic isolation system. As a result of the relative displacement, the seismic risks of some components in the building could increase. The possibility of an increase in seismic risks is especially high in the crossover piping system in the buildings. Previous studies found that an elbow which could be ruptured by low-cycle ratcheting fatigue is one of the weakest elements. Fatigue curves for elbows were suggested based on component tests. However, it is hard to find a quantitative evaluation of the ultimate state of piping elbows. Generally, the energy dissipation of a solid structure can be calculated from the relation between displacement and force. Therefore, in this study, the ultimate state of the pipe elbow, normally considered as failure of the pipe elbow, is defined as leakage under in-plane cyclic loading tests, and a failure estimation method is proposed using a damage index based on energy dissipation.

Measurement Method of the Masseter Muscle Volume Using 3D Computed Tomography (3D CT를 이용한 교근의 부피측정)

  • Baek, Jung Hwan;Choi, Jong Woo;Yoo, Sun Kuk;Kim, Yong Oock;Park, Beyoung Yun
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.589-592
    • /
    • 2005
  • Since G.N. Hounsfield's clinical use of computed tomography in 1971, digital imaging technique using computers has shown an eye opening progress. Progress has made 3-dimensional understanding of not only facial bones but muscles and other connective tissues possible through 3-dimensional reconstruction of preexisting tomographical images. Also, quantitative analysis of density, distance, volume has become possible, allowing objective analysis of preoperative and postoperative states through imaging. The authors measured the masseter muscle volume of 20 normal individuals and 8 female patients through 3-D reconstructive CT imaging and made a statistical analysis of the measurements. The method used in our study may be applied to the diagnosis of disease causing the change of the facial volume and presurgical design as a useful tool to provide objective information on the evaluation of surgery outcome.

Selection of Optimum Support based on Rock Mass Classification and Monitoring Results at NATM Tunnel in Hard Rock (경암지반 NATM 터널에서 암반분류 및 계측에 의한 최적지보공 선정에 관한 연구)

  • 김영근;장정범;정한중
    • Tunnel and Underground Space
    • /
    • v.6 no.3
    • /
    • pp.197-208
    • /
    • 1996
  • Due to the constraints in pre site-investigation for tunnel, it is essential to redesign the support structures suitable for rock mass conditions such as rock strength, ground water and discontinuity conditions for safe tunnel construction. For the selection of optimum support, it is very important to carry out the rock mass classification and in-situ measurement in tunnelling. In this paper, in a mountain tunnel designed by NATM in hard rock, the selectable system for optimum support has been studied. The tunnel is situated at Chun-an in Kyungbu highspeed railway line with 2 lanes over a length of 4, 020 m and a diameter of 15 m. The tunnel was constructed by drill & blasting method and long bench cut method, designed five types of standard support patterns according to rock mass conditions. In this tunnel, face mapping based on image processing of tunnel face and rock mass classification by RMR carried out for the quantitative evaluation of the characteristics of rock mass and compared with rock mass classes in design. Also, in-situ measurement of convergence and crown settlement conducted about 30 m interval, assessed the stability of tunnel from the analysis of monitoring data. Through the results of rock mass classification and in-situ measurement in several sections, the design of supports were modified for the safe and economic tunnelling.

  • PDF

Evaluating the effectiveness of ERS for vessel oil spills using fuzzy evidential reasoning

  • Wang, H.Y.;Ren, J.;Yang, J.Q.;Wang, J.
    • Ocean Systems Engineering
    • /
    • v.5 no.3
    • /
    • pp.161-179
    • /
    • 2015
  • An emergency response system (ERS) for vessel oil spills is a complex and dynamic system comprising a number of subsystems and activities. Failures may occur during the emergency response operations, this has negative impacts on the effectiveness of the ERS. Of the classes of problems in analyzing failures, the lack of quantitative data is fundamental. In fact, most of the empirical data collected via questionnaire survey is subjective in nature and is inevitably associated with uncertainties caused by the human being's inability to provide complete judgement. In addition, incomplete information and/or vagueness of the meaning about the failures add difficulties in evaluating the effectiveness of the system. Therefore this paper proposes a framework to evaluate the ERS effectiveness by using the combination of fuzzy reasoning and evidential synthesis approaches. Based on analyzing the procedure of ERS for oil spills, the failures in the system could be identified, using Analytic Hierarchy Process(AHP)to determine the relative weight of identified failures. Fuzzy reasoning combined with evidential synthesis is applied to evaluate the effectiveness of ERS for oil spills under uncertainties last. The proposed method is capable of dealing with uncertainties in data including ignorance and vagueness which traditional methods cannot effectively handle. A case study is used to illustrate the application of the proposed method.

Comparative Study on the Traditional Market with the Department Store for Placeness Analysis - Focusing on Namdaemun Market Area - (재래시장 장소성 해석을 위한 백화점과의 비교연구 - 남대문상권을 중심으로 -)

  • Kim, In-Sook;Kim, Young-Ook
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.12
    • /
    • pp.21-30
    • /
    • 2018
  • The traditional market has formed for itself through a long time thus has special value of the place. The tangible value of the traditional market is high, however, it became jeopardized to be dismantled since it can not cope with the consumption environment of modern society. Modern industrial society provides an inefficiently and standardized solution to the traditional market by ignoring the identity of place only by the value the traditional market in the law of large distribution industry. This study aims to define the placeness of Namdaemun traditional market by considering tangible value of place. The identity of the place was analyzed as a spatial configuration, space organization, and sense of place through the place's physical setting, activities, and meanings by Edward Ralph. Based on the analysis by Ralph, we analyzed the traditional market and compare to the department store, which is the representative of large scale distributor, using comparative method. We performed quantitative and integrative analysis for the placeness and provide a way to appraise the worth of the traditional market by deviating from the traditional evaluation method.

Quantitative Evaluation of Image Quality using Automatic Exposure Control (AEC 사용 유무에 따른 영상의 화질평가)

  • Kim, Gwang-ho;Yoo, Gwan-ju;Kang, Ji-won;Ko, Bong-joo;Kim, Kyoun-lan;Kim, Min-hee;Yoon, Young-woo;Ye, Soo-young;Choi, Seok-yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.86-89
    • /
    • 2015
  • Quantitative Evaluation of Image Quality using Automatic Exposure Control This it leads, the relationship of control and image between of photographing condition, DR proper use method proposing. Chest phantom acquires Chest PA images which it follows in conditional change, Image evaluation factor (SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), PSNR (Peak Signal to Ratio), RMS (Root Mean Square)). It excepted RMS price, SNR, CNR, PSNR the case which uses AEC it came out being high The fact that the quality of image is better there was a case which does not use AEC. but Price it was slight. Image qualitative it was deficient in AEC use presence. Through this, the overall situation and most efficient use of radiation workers is better suited. But Passive AEC use would be appropriate for use rather than proactive AEC.

  • PDF

Reduction of Spectral Distortion in PAN-sharpening Using Spectral Adjustment and Anisotropic Diffusion (분광 조정과 비등방성 확산에 의한 PAN-Sharpened 영상의 분광 왜곡 완화)

  • Lee, Sanghoon
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.6
    • /
    • pp.571-582
    • /
    • 2015
  • This paper proposes a scheme to reduce spectral distortion in PAN-sharpening which produces a MultiSpectral image (MS) with the higher resolution of PANchromatic image (PAN). The spectral distortion results from reconstructing spatial details of PAN image in the MS image. The proposed method employs Spectral Adjustment and Anisotropic Diffusion to make a reduction of the distortion. The spectral adjustment makes the PAN-sharpened image agree with the original MS image, but causes block distortion because the spectral response of a pixel in the lower resolution is assumed to be equal to the average response of the pixels belonging to the corresponding area in the higher resolution at a same wavelength. The block distortion is corrected by the anisotropic diffusion which uses a conduct coefficient estimating from a local computation of PAN image. It results in yielding a PAN-sharpened image with the spatial structure of PAN image. GSA is one of PAN-sharpening techniques which are efficient in computation as well as good in quantitative quality evaluation. This study suggests the GSA as a preliminary PAN-sharpening method. Two data sets were used in the experiment to evaluate the proposed scheme. One is a Dubaisat-2 image of $1024{\times}1024$ observed at Los Angeles area, USA on February, 2014, the other is an IKONOS of $2048{\times}2048$ observed at Anyang, Korea on March, 2002. The experimental results show that the proposed scheme yields the PAN-sharpened images which have much less spectral distortion and better quantitative quality evaluation.

Evaluation of Absorption and Release, Survival Efficiency and Recovery Rate of Transport Medium according to the CLSI M40-A2 Standard (CLSI M40-A2 기준에 따른 수송배지의 흡수 및 배출, 생존 효율, 회수율 평가)

  • Ha, Sung-Il;Suk, Hyun-Soo;Shin, Jeong-Seob;Heo, Woong;Park, Kang-Gyun;Park, Yeon-Joon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.164-170
    • /
    • 2019
  • The absorption and release capacities, survival efficiency, and recovery rates of five kinds of transport media were evaluated based on the swab elution method (Quantitative) of CLSI (Clinical and Laboratory Standards Institute) M40-A2. Liquid media showed mostly better results than semi-solid media in the three evaluations. The flocked swabs had better ability to absorption and discharge bacteria than the standard swabs. The liquid medium (S4) had the best survival efficiency. Pneumococcal strains with poor growth had a higher survival efficiency and recovery rate in liquid media (S4, S5). The results of microbial recovery showed that S. pyogenes met all the CLSI standards in all media. S. pneumoniae was inadequate in the semi- solid media (S2, S3) and all the remaining media met the criteria. H. influenzae was unsuitable in semi-solid media (S1, S3) and met the criteria in semi-solid medium (S2) and liquid medium (S4, S5). The viability of the H. influenzae, pneumococcal strain causing respiratory disease, was poor in most media. Overgrowth of P. aeruginosa was observed at room temperature. The combination of liquid medium and flocked swab confirmed the best results in the three evaluation methods.

Quantitative Indices of Small Heart According to Reconstruction Method of Myocardial Perfusion SPECT Using the 201Tl (201Tl을 이용한 심근관류 SPECT에서 재구성 방법에 따른 작은 용적 심장의 정량 지표 변화)

  • Kim, Sung Hwan;Ryu, Jae Kwang;Yoon, Soon Sang;Kim, Eun Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: Myocardial perfusion SPECT using $^{201}Tl$ is an important method for viability of left ventricle and quantitative evaluation of cardiac function and now various reconstruction methods are used to improve the image quality. But in case of small sized heart, you should always be careful because of the Partial Volume Effect which may cause errors of quantitative indices at the reconstruction step. So, In this study, we compared those quantitative indices of left ventricle according to the reconstruction method of myocardial perfusion SPECT with the Echocardiography and verified the degree of the differences between them. Materials and Methods: Based on ESV 30 mL of Echocardiography, we divided 278 patients (male;98, female;188, Mean age;$65.5{\pm}11.1$) who visited the Asan medical center from February to September, 2012 into two categories; below the criteria to small sized heart, otherwise, normal or large sized heart. Filtered and output each case, we applied the method of FBP and OSEM to each of them, and calculated EDV, ESV and LVEF, and we conducted statistical processing through Repeated Measures ANOVA with indices that measured in Echocardiography. Results: In case of men and women, there were no significant difference in EDV between FBP and OSEM (p=0.053, p=0.098), but in case of Echocardiography, there were meaningful differences (p<0.001). The change of ESV especially women in small sized heard, significant differences has occurred among FBP, OSEM and Echocardiography. Also, in LVEF, there were no difference in men and women who have normal sized heart among FBP, OSEM and Echocardiography (p=0.375, p=0.969), but the women with small sized heart have showed significant differences (p<0.001). Conclusion: The change in quantitative indices of left ventricle between Nuclear cardiology image reconstruction, no difference has occurred in the patients with normal sized heart but based on ESV, under 30 mL of small sized heart, especially in female, there were significant differences in FBP, OSEM and Echocardiography. We found out that overestimated LVEF caused by PVE can be reduced in average by applying OSEM to all kinds of gamma camera, which are used in analyzing the differences.

  • PDF

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF