• Title/Summary/Keyword: quality measurement tool

Search Result 342, Processing Time 0.023 seconds

A Study of an OMM System for Machined Spherical form Using the Volumetric Error Calibration of Machining Center (머시닝센터의 체적오차 보상을 통한 구면 가공형상 측정 OMM시스템 연구)

  • Kim, Sung-Chung;Kim, Ok-Hyun;Lee, Eung-Suk;Oh, Chang-Jin;Lee, Chan-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.7
    • /
    • pp.98-105
    • /
    • 2001
  • The machining accuracy is affected by geometric, volumetric errors of the machine tools. To improve the product quality, we need to enhance the machining accuracy of the machine tools. To this point of view, measurement and inspection of finished part as error analysis of machine tools ahas been studied for last several decades. This paper suggests the enhancement method of machining accuracy for precision machining of high quality metal reflection mirror or optics lens, etc. In this paper, we study 1) the compensation of linear pitch error with NC controller compensation function using laser interferometer measurement, 2) the method for enhancing the accuracy of NC milling machining by modeling and compensation of volumetric error, 3) the spherical surface manufacturing by modeling and compensation of volumetric error of the machine tool, 4) the system development of OMM without detaching work piece from a bed of machine tool after working, 5) the generation of the finished part profile by OMM. Furthermore, the output of OMM is compared with that of CMM, and verified the feasibility of the measurement system.

  • PDF

Evaluation of Polishing Characteristics for Polishing Patterns (연마패턴에 따른 연마특성 평가)

  • Cho J.R.;Lee J.Y.;Kimm N.K.;Jung Y.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1579-1582
    • /
    • 2005
  • Polishing is cutting process that polished workpiece by relative motion of abrasive grain between polishing tool and workpiece. According to relative motion forms(polishing patterns) of abrasive grain, the surface quality is different. Then, polishing patterns are important essential in polishing process. In work field, polishing patterns are determined by an expert of experience. Therefore, to work effective polishing, it is necessary that evaluate polishing characteristics for polishing patterns. And, polishing machine is made with cartesian coordinate robots, we estimate polishing characteristics by measurement of surface roughness.

  • PDF

An Empirical Study on Service Quality and User Satisfaction of Business Consulting (경영컨설팅 서비스품질과 고객만족에 관한 실증적 연구)

  • Kim, Dong-Il;Kang, Hee-Sam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.840-845
    • /
    • 2008
  • This study through theoretical investigation connected with business consulting quality of service and pre-study, actual proof was analyzed on the basis of research hypothesis about domestic consulting's element of qualify of service. Analyzed interrelation degree because do result that is customer satisfaction measurement classifying roughly quality of service and expense quality in actual proof analysis by a representation measurement tool. By first if summarize this study finding, was construed by thing which relativity is very high mutually relation about service quality and satisfaction of customer satisfaction. Therefore, was assumed by leading recognition that is very positive in service quality and customer relation. Secondly, expense quality of service and recycling of customer satisfaction measurement inside synonymy confirm. Hereafter, We can had assumption information consulting and business consulting from medium and small enterprises to very important competition factor.

Development of Measurement Scale for the Quality of Life in Hypertensive Patients (고혈압 환자의 삶의 질 측정도구 개발)

  • Kim, Keon-Yeop;Kam, Sin;Lee, Sang-Won;Park, Ki-Soo;Chae, Shung-Chull;Chun, Byung-Yeol
    • Journal of Preventive Medicine and Public Health
    • /
    • v.38 no.1
    • /
    • pp.61-70
    • /
    • 2005
  • Objectives : To develop a tool for multidimensional measurement of the quality of life, which was psychometrically sound, short, and easy to administer for patients with hypertension. Methods : A sample of 1,115 hypertensive patients aged 20 or above in Cheong-Song County was studied from June 1997 to October 1998. In the development of the instrumental stage, the authors first conceptualized the quality of life. Item generation, item reduction, and questionnaire formatting were followed. Item-level (item descriptive, missing%, item internal consistency, item discriminant validity) analysis, scale-level (scale descriptive, floor and ceiling effect) analysis, and other tests(Cronbach's alpha, inter-dimension correlations, factor analysis, clinical validity) were performed to evaluate the validity and reliability of the new measurement scale. After 1 year, responsiveness and confirmatory factor analysis were performed. Results : The results of both item-level and scale-level analyses were acceptable. An acceptable degree of internal consistency was observed for each of the dimensions (Cronbach's alpha was 0.60 or higher). Inter-dimension correlations were below 0.50 and the factor analysis result was the same as the intended dimension structure. Correlation coefficients between perceived health status, stress and dimensions were proven to be acceptable. The result of comparing dimensional score means among ADL and MMSE-K groups above 60 years was statistically significant(p<0.05). The result of confirmatory factor analysis concluded that the dimensional structure model was well fitted. However, the result of responsiveness test using sensitivity and specificity was unsatisfactory. Conclusions : The newly developed measurement scale is psychometrically reliable and valid instrument for measuring quality of life in hypertensive patients.

Development of a Maintenance Support System for C++ Programs (C++프로그램의 유지보수 지원 시스템 개발)

  • Moon, Yang-Sun;Jang, Gun-Sil;Yoo, Cheol-Jung;Chang, Ok-Bae
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.7
    • /
    • pp.1759-1773
    • /
    • 1998
  • This paper introduces a maintenance support tool for C++ programs. The tool was extended by adding a documentation supporting tool(DT) and an OOD/OOP style guidelines supporting tool(OOD\ulcornerP-GT) to previous work results, the complexity measurement tool(CT) and the visualization tool(VT). The tool was named C++ MT. For the extention, we studied a documentation method of object oriented programs, analyzed and grouped the OOD/OOP style guidelines suggested in some works. The DT developed in this paper helps programmer understand, cange, and est programs, and also extract the reuse components. OOD/P-GT provides guielines for programmer to improve program quality.

  • PDF

Deformation Characteristics of an Automotive Outer Door Panel by Vacuum-assisted Incremental Sheet Forming using Multi-tool paths (진공점진성형에서 복합공구경로가 차량용 외판부 도어패널의 변형특성에 미치는 영향 분석)

  • H.W. Youn;N. Park
    • Transactions of Materials Processing
    • /
    • v.32 no.4
    • /
    • pp.208-214
    • /
    • 2023
  • This paper discusses the deformation characteristics of a scaled-down automotive outer door panel with vacuum-assisted incremental sheet forming. The vacuum condition between the die and Al6052-H32 sheet with a thickness of 1.0 mm is reviewed with the goal of improving the geometrical accuracy of the target product. The material flow according to the forming tool path, including the multi-tool path and conventional contour tool path, is investigated considering the degradation of the pillow effect. To reduce friction between the tool and the sheet during incremental forming, automotive engine oil (5W-30) is used as a lubricant, and the strain field on the surface of the formed product is analyzed using ARGUS. By comparing the geometry and material flow characteristics of products under different test conditions, it is confirmed that the product surface quality can be significantly improved when the vacuum condition is employed in conjunction with a multi-tool path strategy.

Review Study of Headache Measurement Tools - Mainly on Reliability and Validity - (두통 평가 척도에 관한 고찰 - 신뢰도와 타당도를 중심으로 -)

  • Kim, Eun-Jung;Jung, Chan-Yung;Jang, Min-Gee;Yoon, Eun-Hye;Nam, Dong-Woo;Kang, Jung-Won;Lee, Jae-Dong;Lee, Seung-Deok;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.51-64
    • /
    • 2010
  • Objectives : To introduce and compare various headache measurement tools, in order to provide fundamental information for future clinical trials and development of oriental medicine measurement tools. Methods : Eight headache assessment scales, Migraine-Specific Quality of Life Questionnaire(MQoLQ), Migraine-Specific Quality of Life(MSQOL), Migraine-Specific Quality of Life Questionnaire(MSQ), The Headache Impact Questionnaire(HImQ), Headcahe Needs Assessment Survey(HANA), Henry Ford Headache disability Inventory(HDI), Migraine Disablity Assessment Scale(MIDAS) and Headache Impact Test(HIT-6), were searched through Pubmed. General character, the process of development, verification of reliability, internal consistency, responsiveness to patient's change and validity were reviewed. Results : In assessing the quality of life of migraine patients, MQoLQ can be used to measure the change within 24 hours, MSQ and MSQOL can be used to measure the change during a relatively longer period of time. The frequency and bothersomeness of headache can be easily measured by HANA. HImQ can be used to measure the intensity of headache and the influence on normal daily activities. HDI can measure the emotional difficulties of headache patients. HIT-6 and MIDAS makes measurements possible in a short period of time, and the reliability and validity have been verified numerously. HIT-6 and MIDAS are the most frequently used measurement tools because they are simple and easy for both the assessor and the patient to understand and use. Conclusions : In this study, various headache assessment tools have been reviewed. The assessed tools were widely used after being verified for their reliability and validity. We hope this study provides fundamental information in establishing future clinical trial and clinical practice guidelines. We also hope this study to contribute to the development of an oriental medicine assessment tool for headache.

Development of a system for measuring inside & outside diameters of automobile hub (자동차 허브 내.외경 측정 시스템 개발)

  • 윤규택;이동주;최만용;박혜원;박정학]
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.363-368
    • /
    • 2002
  • An automobile hub is composed of a hollow cylindrical part with inner and outer diameters. These hub diameters must be precise, as any irregularities in them (diameters) can influence/degrade the motion of an automobile with this problem. Highly accurate and reliable hub inner and outer diameters measurement systems are therefore required for inspection of the diameters. In this research, an automobile hub inner and outer diameters measurement system has been developed and tested. The system consists of measuring heads with LVDT sensors, and associated software for automatic measurement and calibration of the diameters and the sensors respectively. The system has been evaluated in comparison with an existing measurement system, and the following outcomes have been achieved; .Improved and guaranteed quality and reliability .Increased productivity and cost reduction. These results prove the system developed in this research to be suitable for automobile hub inspection.

  • PDF

A study on the Error Separation Method in Rotation Accuracy Measurement of High Precision Spindle Unit (고정밀 스핀들의 회전정밀도 측정 오차 분리법에 관한 연구)

  • Kim, Sang-Hwa;Kim, Byung-Ha;Jin, Yong-Gyoo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.78-84
    • /
    • 2014
  • The rotation of a spindle unit must be accurate for high-quality machining and to improve the quality of the machine tools.Therefore, the proper measurement of the rotation accuracy and ensuring a proper analysis are very important. Separate processes are necessary because spindle errors and roundness errors associated with the test balls can both factor into the measured rotation error values. We used three methods to discern test ball errors and analyzed which could be deemed as the most proper technique in a test of the rotation accuracy of the main spindle of a machine tool.

A New Available Bandwidth Measurement Technique with Accurate Capacity Estimation (정확한 고정대역폭 추정을 통한 새로운 가용대역폭 측정 기법)

  • Cho Seongho;Choe Han;Kim Chong-kwon
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.4
    • /
    • pp.495-507
    • /
    • 2005
  • Measuring the end-to-end available bandwidth in the Internet is a useful tool for distributedapplication services or QoS (Quality-of-Service) guarantee. To measure the end-to-end available bandwidth, Single-hop Gap model-based packet train measurement techniques are well-known. However, the error of packet train output gap can happen by network topologies. This error of the output gap causes the inaccuracy of the available bandwidth measurement. In this paper, we propose a new end-to-end available bandwidth measurement technique with accurate capacity measurement and fast convergence methods. To solve the erroneous capacity measurement problem of the back-to-back packet train transmission, we propose a new available bandwidth measurement method by decoupling the capacity measurement with the initial gap of the packet train. Also, we propose a new technique to predict the proper initial gap of the packet train for faster convergence. We evaluate our proposed method by the simulation in various topologies comparing with previous methods.