• 제목/요약/키워드: pv module

검색결과 599건 처리시간 0.03초

에너지 저장 장치가 적용된 태양광 하이브리드 모듈형 시스템의 전력 조류 제어 (Power Flow Control of PV Hybrid Module System with ESS)

  • 이순령;김영호;장진우;최봉연;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.473-474
    • /
    • 2013
  • In this paper, a power flow control of PV hybrid module system with ESS is proposed. Photovoltaic(PV) hybrid module system is consist of individual converter, central inverter, and energy storage system(ESS). Because PV power can be changed in particular hours and environment condition, the power management control for ESS is required. In this paper, the power flow control method for PV hybrid module system with ESS is proposed. The validity of proposed control method is verified by simulations and theoretical analysis.

  • PDF

PV-AC 모듈형 플라이백 인버터의 전류 센서리스 MPPT제어기법 (Current sensorless MPPT for PV-AC module flyback inverter)

  • 최봉연;김영호;지용혁;이태원;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.49-50
    • /
    • 2012
  • Maximum power point tracking(MPPT) algorithm is needed in PV AC module power conditioning system because of the nonlinear current-voltage characteristics. Conventional MPPT algorithm is required to know PV-module output current and voltage. Thus, PV-AC module must have voltage and current sensor. In this paper, a current-sensorless MPPT algorithm, which uses only the voltage sensor, is presented for Flyback inverter.

  • PDF

태양광 발전시스템에서 모듈 설치 각도와 어레이 간격의 비교 연구 (Comparison Researches for Installation of the Module Angles and Array Spacing on Photovoltaic Power System)

  • 최동진
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.162-168
    • /
    • 2009
  • 본 논문에서는 태양전지를 가지고 일정량의 태양광으로부터 최대 유효전력을 얻기 위해 고정식 태양광 발전시스템과 태양 위치추적기를 부착한 태양광 발전시스템에서 PV모듈의 각도 변화 및 어레이 간격에 따른 최적의 발전효율에 대한 연구 및 실험을 하였다. 먼저, PV 모듈의 다양한 각도를 가지고 실험한 결과 PV 모듈 경사각 30[$^{\circ}$]에서 측정한 결과 값이 경사각 20[$^{\circ}$] 및 40[$^{\circ}$]일 때보다 발전 효율이 $12{\sim}17$[%] 상승되었다. 그러므로 본 논문의 연구 결과에서는 태양광 발전시스템의 실용화 측면에서 PV 모듈의 경사각 30[$^{\circ}$] 설치를 하여 발전을 하는 것이 가장 좋은 변환 효율을 얻을 수 있었다. 하지만 태양전지를 지붕 및 옥상에 설치를 할 경우, 면적 활용이 좁고 겨울에 눈이 쌓이게 될 경우에는 경사각에 의해 빠르게 쓸려 내려갈 수 있도록 경사각을 35[$^{\circ}$]로 선정하는 것이 타당하다.

스펜드럴부 적용 BIPV 모듈의 열 특성 분석 (Analysis on Thermal Performance of BIPV in Spandrel)

  • 김하련;김진희;강기환;유권종;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.364-369
    • /
    • 2011
  • Recently, the cases of BIPV(Building-integrated Photovoltaic) have been increased with interest in renewable energy application for buildings. PV System in building can perform a variety of roles as an energy supplier, exterior materials, aesthetic element and etc. To apply PV modules in buildings, various factors should be considered, such as the installation angle and orientation of PV module, shading, and temperature. The temperature of PV modules that are attached to building surfaces especially is one of the most important factors, as it affects both the electrical efficiency of a PV module and the energy load in a building. BIPV modules designed as finished material for spandrels are presented in this paper. The purpose of this study is to analysis on the thermal performance characteristics of BIPV modules. This study dealt with different types of BIPV modules depending on the backside material, such as clear glass and backsheet. The analysis of monitoring data shows that the PV module temperature was closely related to the solar radiation on the BIPV module surface, and the BIPV used at the backside also had an effect on the PV module temperature that in turn determines its thermal performance.

  • PDF

유무연 용융도금 리본에 따른 결정질 실리콘 태양전지 모듈 열화거동 (Degradation Behavior of Eutectic and Pb-free Solder Plated Ribbon in Crystalline Silicon Photovoltaic Module)

  • 김주희;김아영;박노창;하정원;이상권;홍원식
    • Journal of Welding and Joining
    • /
    • 제32권6호
    • /
    • pp.75-81
    • /
    • 2014
  • Usage of heavy metal element (Pb, Hg and Cd etc.) in electronic devices have been restricted due to the environmental banning of the European Union, such as WEEE and RoHS. Therefore, it is needed to develop the Pb-free solder plated ribbon in photovoltaic (PV) module. This study described that degradation characteristics of PV module under damp heat (DH, $85^{\circ}C$ and 85% R.H.) condition test for 1,000 h. Solar cell ribbons were utilized to hot dipping plate with Pb-free solder alloys. Two types of Pb-free solder plated ribbons, Sn-3.0Ag-0.5Cu (SAC305) and Sn-48Bi-2Ag, and an electroless Sn-40Pb solder hot dipping plated ribbon as a reference sample were prepared to evaluate degradation characteristics. To detect the degradation of PV module with the eutectic and Pb-free solder plated ribbons, I-V curve, electro-luminescence (EL) and cross-sectional SEM analysis were carried out. DH test results show that the reason of maximum power (Pm) drop was mainly due to the decrease fill factor (FF). It was attributed to the crack or oxidation of interface between the cell and the ribbon. Among PV modules with the eutectic and Pb-free solder plated ribbon, the PV module with SAC305 ribbon relatively showed higher stability after DH test than the case of PV module with Sn-40Pb and Sn-48Bi-2Ag solder plated ribbons.

지붕 설치형 결정질 실리콘 태양전지모듈의 온도 특성 (Roof-attached Crystalline Silicon Photovoltaic Module's Thermal Characteristics)

  • 김경수;강기환;유권종;윤순길
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.11-18
    • /
    • 2012
  • To expect accurately the maximum power of solar cell module under various installation conditions, it is required to know the performance characteristics like temperature dependence. Today, the PV (photovoltaic) market in Korea has been growing. Also BIPV (building integrated photovoltaic) systems are diversified and become popular. But thermal dependence of PV module is little known to customers and system installers. In IEC 61215,a regulation for testing the crystalline silicon solar cell module, the testing method is specified for modules. However there is limitation for testing the module with diverse application examples. In extreme installation method, there is no air flow between rear side of module and ambient, and it can induce temperature increase. In this paper, we studied the roof type installation of PV module on the surface of one-axis tracker system. We measured temperature on every component of PV module and compared to open-rack structure. As a result, we provide the foundation that explains temperature characteristics and NOCT (nominal operation cell temperature) difference. The detail description will be specified as the following paper.

A Novel Flyback-type Utility Interactive Inverter for AC Module Systems

  • Shimizu Toshihisa;Nakamura Naoki;Wada Keiji
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.518-522
    • /
    • 2001
  • In recent years, natural energy has attracted growing interest because of environmental concerns. Many studies have been focused on photovoltaic power generation systems because of the ease of use in urban areas. On the conventional system, many photovoltaic modules (PV modules) are connected in series in order to obtain the sufficient DC-bus voltage for generating AC output voltage at the inverter circuit. However, the total generation power on the PV modules sometimes decreases remarkably because of the shadows that partially cover the PV modules. In order to overcome this drawback, an AC module strategy is proposed. On this system, a small power DC-AC utility interactive inverter is mounted on each PV module individually and the inverter operates so as to generate the maximum power from the corresponding PV module. This paper presents a novel flyback-type utility interactive inverter circuit suitable for AC module systems. The feature of the proposed system are, (1) small in volume and light in weight, (2) stable AC current injection, (3) enabling a small DC capacitor. The effectiveness of the proposed system is clarified through the simulation and the experiments.

  • PDF

건물외피용 태양광발전 BIPV 모듈 개발 연구 (Development of Building Integrated PV(BIPV) module for the replacement of commercial building envelope materials)

  • 윤종호;김종일;이길송;유권종
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.113-119
    • /
    • 2004
  • As Building Integrated Photovoltaic(BIPV) system replaces the conventional building finishing materials with PV modules, two function of electricity generation and building envelope can be expected. Therefore BIPV can be a good alternative technology for the 21 century environment-friendly buildings. The objective of this paper is to develope BIPV modules for a commercial buildings of which structure is mainly light-weight, curtain wall system. Two types of module are developed for a opaque part and a transparent part of building envelope. Current technology level and market status of Korea determines the configuration of developed BIPV modules. Architectural considerations for the integration of PV module to building envelope such as building structure, construction type, safety, regulation, maintenance etc. have been carefully reflected from the early stage of BIPV module design. Especially the survey result of current building envelope materials determines the size of unit BIPV modules and a unique cladding method for PV module installation is developed. Trial product of BIPV modules and cladding hardwares are manufactured and sample construction details for a demonstration building are proposed.

고온용 PV module을 위한 PVB film 광특성 연구 (The analysis on PVB film optical characteristics for PV module generating in high-temperature)

  • 이상훈;김경수;강기환;유권종;안형근;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1320-1321
    • /
    • 2011
  • According to the advance that solar power plants go into the desert, power plants are getting greater capacity. The desert is unspoiled resources and it is well suited to build a solar power plant, because of abundant solar radiation and long sunshine duration. but existing PV modules have several weaknesses and don't generate lower the rated power, because it wasn't designed to produce in extreme environments like a desert climate. The one of the weaknesses of PV modules is that the characteristics of the temperature of the Encapsulants(EVA sheet) are not good in a desert climate, because the EVA sheet is melt at high temperature. In this study, a decrease phenomenon of the transmittance depending on the melting point of the Encapsulant(PV module using EVA sheet : $75^{\circ}C$ PV module using PVB film : $110^{\circ}C$) is suggested, it would be the one of the important factors to achieve rated output of the PV modules in high temperature climate regions.

  • PDF

태양전지 모듈 구조와 바이패싱 동작 포인트의 관계 분석 (The study on the relationship between structure of PV module and bypassing point)

  • 지양근;공지현;강기환;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.70-70
    • /
    • 2010
  • Until recently. the study about bypass diode has been limited to theoretical study. but, in this paper, We study on the relationship between structure of PV module and Bypassing point by simulation software(Pspice). We expected the design on the PV module has an effect on bypassing point. So, we designated the two kind of experiment with PV modules. One of the experiment is on the relationship between the number of rows and Bypassing point on the PV modules, the other experiment is on the relationship between the number of groups(two columns) on the PV modules.(around 50Wp, 100Wp, 150Wp, 200WP) As the result, the more increase the number of rows, bypassing point is faster. And the more increase the number of groups in more than 3 groups, bypassing point is faster more than case of increasing the rows.

  • PDF