• Title/Summary/Keyword: purpose

Search Result 155,985, Processing Time 0.161 seconds

Comparative evaluation of radiation exposure in radiation-related workers (방사선 작업종사자의 피폭선량 비교 평가)

  • Baek, Seong-Min;Jang, Eun-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.195-200
    • /
    • 2011
  • The purpose of this study is to investigate the dose of radiation exposure to radiation-related workers in a hospital setting, thus increasing awareness of the health risk to the radiation-related workers. The result of the analysis showed the average dose of radiation exposure to radiation-related workers in hospital K was $0.75{\pm}0.26mSv$ in 2008, $0.67{\pm}0.30mSv$ in 2009, and $0.92{\pm}0.33mSv$ in 2010. The average dose of radiation exposure in hospital P was $0.43{\pm}0.13mSv$ in 2008, $0.43{\pm}0.20mSv$ in 2009, and $0.33{\pm}0.85mSv$ in 2010. The average dose of radiation exposure in hospital K by age group was 13.39mSv for age 20 to 29, 8.37mSv for age 30 to 39, 1.19mSv for age 40 to 49, 0.28mSv for age 50 to 59, and 0.32mSv for age 60 to 69 The average dose of radiation exposure in hospital P by age group was 0.33mSv for age 20 to 29, 1.41mSv for age 30 to 39, 0.83mSv for age 40 to 49, 1.66mSv for age 50 to 59, and 1.12mSv for age 60 to 69. Moreover, the average radiation exposure to radiation-related workers over 3 year period by gender group in hospital K was $2.92{\pm}1.03mSv$ for male group and $0.94{\pm}0.93mSv$ for female group. The average radiation exposure over 3 year period by gender group in hospital P was $0.66{\pm}0.18mSv$ for male group and $1.80{\pm}0.60mSv$ for female group. Persons working in diagnostic radiology department received mean of $1.65{\pm}1.54mSv/year$, mean $1.17{\pm}0.82mSv/year$ in radiation oncology, mean $1.79{\pm}1.42mSv/year$ at nuclear medicine department and mean $0.99{\pm}0.51mSv/year$ at other departments. Radiation exposure was higher than that of other departments(p<0.05). Doctors and technologists received higher radiation exposure (mean $1.75{\pm}1.17mSv/year$, $1.60{\pm}1.39mSv/year$ each) than other workers(p<0.05). Measurement and evaluation of radiation exposure in radiation-related workers should be widely conducted accurately and consistently in the radiation-related occupational setting so that people in these occupational settings are more aware of the risk from radiation exposure, and thus give more attention and caution to decrease radiation exposure. It would be essential to minimize accumulated radiation dose in the radiation-related occupational setting in order to maintain and improve the health of radiation-related workers.

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF

Medical Radiation Exposure Dose of Workers in the Private Study of the Job Function (의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.3-12
    • /
    • 2011
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: From January 1, 2010 December 31, 2010, medical practitioners working in the radiation is classified as a regular personal radiation dosimetry, and subsequently one year 540 people managed investigation department to target workers, dose sectional area, working period, identify the job function-related tasks for a deep dose, respectively, the annual average radiation dose were analyzed. Frequency analysis methods include ANOVA was performed. Results: Medical radiation workers in the department an annual radiation dose of Nuclear and 4.57 mSv a was highest, dose zone-specific distribution of nuclear medicine and in the 5.01~19.05 mSv in the high dose area distribution showed departmental radiation four of the annual radiation dose of Nuclear and 7.14 mSv showed the highest radiation dose. More work an average annual radiation dose according to the job function related to the synthesis of Cyclotron to 17.47 mSv work showed the highest radiation dose, Gamma camera Cinema Room 7.24 mSv, PET/CT Cinema Room service is 7.60 mSv, 2.04 mSv in order of intervention high, were analyzed. Working period, according to domain-specific average annual dose of radiation dose from 10 to 14 in oral and maxillofacial radiology practitioners as high as 1.01~3.00 mSv average dose showed the Department of Radiology, 1-4 years, 5-9 years, respectively, 1.01 workers~8.00 mSv in the range of the most high-dose region showed the distribution, nuclear medicine, and the 1-4 years, 5-9 years 3.01~19.05 mSv, respectively, workers of the highest dose showed the distribution of the area in the range of 10 to 14 years, Workers at 15-19 3.01~15.00 mSv, respectively in the range of the high-dose region were distributed. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image (PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가)

  • Park, Sun-Myung;Lee, Hyuk;Hong, Gun-Chul;Chung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.41-46
    • /
    • 2011
  • Purpose: The result of exam using an imaging device is very closely related with the image quality. Moreover, this image quality can be changed according to the condition of image acquisition and evaluation method. In this study, we evaluated the image quality according to the difference of pre-set method in PET/CT image. Materials & Methods: PET/CT Discovery STe16 (GE Healthcare, Milwaukee, USA), Chest PET phantom (Experiment 1) and 94 NEMA phantom (Experiment 2) were used. Phantom were filled with $^{18}F$-FDG maintaining hot sphere and background ratio to 4:1. In the case of experiment 1, we set the radio activity concentration on 3.5, 6.0, 8.6 kBq/mL. In the case of experiment 2, we set the radio activity concentration on 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL. All experiments were performed with the time-set method for 2 minutes 30 seconds per frame and the count-set method with one hundred million counts in 3D mode after CT transmission scan. For the evaluation of the image quality, we compared each results by using the NECR and SNR. Results: In the experiment 1, both the NECR and SNR were increased as radioactivity concentration getting increased. The NECR was shown as 53.7, 66.9, 91.4. and SNR was shown as 7.9, 10.0, 11.7. Both the NECR and SNR were increased in time-set method. But the count-set method's pattern was not similar with the time-set method. The NECR was shown as 53.8, 69.1, 97.8, and SNR was shown as 14.1, 14.7 14.4. The SNR was not increased in count-set method. In experiment 2, results of both the NECR and SNR were shown as 45.1, 70.6, 95.3, 115.6, 134.6, 162.2 and 7.1, 8.8, 10.6, 11.5, 12.7, 14.0. These results were shown similar patten with the experiment 1. Moreover, when the count-set method was applied, the NECR was shown as 42.1, 67.3, 92.1, 112.2, 130.7, 158.7, and SNR was shown as 15.2, 15.9, 15.6, 15.4, 15.5, 14.9. The NECR was increased but SNR was not shown same pattern. Conclusion: Increment of administered radioactivity improves the quality of image unconcerned with the pre-set method. However, NECR was not influenced by increment of total acquisition counts through simple increasing scan duration without increment of administered activity. In case of count-set method, the SNR was shown similar value despite of increment of radioactivity. So, the administered activity is more important than the scan duration. And we have to consider that evaluation of image quality using only SNR may not be appropriate.

  • PDF

A Study on the Legal Proposal of Crew's Fatigue Management in the Aviation Regulations (항공법규에서의 승무원 피로관리기준 도입방안에 관한 연구 - ICAO, FAA, EASA 기준을 중심으로 -)

  • Lee, Koo-Hee;Hwang, Ho-Won
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.27 no.1
    • /
    • pp.29-73
    • /
    • 2012
  • Aviation safety is the State and industry's top priority and more scientific approaches for fatigue management should be needed. There are lately various studies and regulation changes for crew fatigue management with ICAO, FAA and EASA. ICAO issued the provisions of fatigue management for flight crew since 1st edition, 1969, of Annex 6 operation of aircraft as a Standards and Recommended practice(SARPs). Unfortunately, there have been few changes and improvement to fatigue management provisions since the time they were first introduced. However the SARPs have been big changed lately. ICAO published guidance materials for development of prescriptive fatigue regulations through amendment 33A of Annex 6 Part 1 as applicable November 19th 2009. And then ICAO introduced additional amendment for using Fatigue Risk Management System (FRMS) with $35^{th}$ amendment in 2011. According to the Annex 6, the State of the operator shall establish a) regulations for flight time, flight duty period, duty period and rest period limitations and b) FRMS regulations. The Operator shall implement one of following 3 provisions a) flight time, flight duty period, duty period and rest period limitations within the prescriptive fatigue management regulations established by the State of the Operator; or b) a FRMS; or c) a combination of a) and b). U.S. FAA recently published several kinds of Advisory Circular about flightcrew fatigue. U.S. passed "Airline Safety and FAA Extension Act of 2010" into law on August 1st, 2010. This mandates all commercial air carriers to develop a FAA-acceptable Fatigue Risk Management Plan(FRMP) by October 31st, 2010. Also, on May 16, 2012, the FAA published a final rule(correction) entitled 'Flightcrew Member Duty and Rest Requirements; correction to amend its existing prescriptive regulations. The new requirements are required to implement same regulations for domestic, flag and supplemental operations from January 4, 2014. EASA introduced a Notice of Proposed Amendment (NPA) 2010-14 entitled "Draft opinion of the European Aviation Safety Agency for a Commission Regulation establishing the implementing rules on Flight and Duty Time Limitations and Rest Requirements for Commercial Air Transport with aeroplanes" on December 10, 2010. The purpose of this NPA is to develop and implement fatigue management for commercial air transport operations. Comparing with Korean and foreign regulations regarding fatigue management, the provisions of ICAO, FAA, EASA are more considering various fatigue factors and conditions. Korea regulations should be needed for some development of insufficiency points. In this thesis, I present the results of the comparative study between domestic and foreign regulations in respect of fatigue management crew member. Also, I suggest legal proposals for amendment of Korea Aviation act and Enforcement Regulations concerning fatigue management for crew members. I hope that this paper is helpful to change korea fatigue regulations, to enhance aviation safety, and to reduce the number of accidents relating to fatigue. Fatigue should be managed at all level such as regulators, experts, operators and pilots. Authority should change surveillance mind-set from regulatory auditor to expert adviser. Operators should identify various fatigue factors and consider to crew scheduling them. Crews should strongly manage both individual and duty-oriented fatigue issues.

  • PDF

A Study on the Effect of the Introduction Characteristics of Cloud Computing Services on the Performance Expectancy and the Intention to Use: From the Perspective of the Innovation Diffusion Theory (클라우드 컴퓨팅 서비스의 도입특성이 조직의 성과기대 및 사용의도에 미치는 영향에 관한 연구: 혁신확산 이론 관점)

  • Lim, Jae Su;Oh, Jay In
    • Asia pacific journal of information systems
    • /
    • v.22 no.3
    • /
    • pp.99-124
    • /
    • 2012
  • Our society has long been talking about necessity for innovation. Since companies in particular need to carry out business innovation in their overall processes, they have attempted to apply many innovation factors on sites and become to pay more attention to their innovation. In order to achieve this goal, companies has applied various information technologies (IT) on sites as a means of innovation, and consequently IT have been greatly developed. It is natural for the field of IT to have faced another revolution which is called cloud computing, which is expected to result in innovative changes in software application via the Internet, data storing, the use of devices, and their operations. As a vehicle of innovation, cloud computing is expected to lead the changes and advancement of our society and the business world. Although many scholars have researched on a variety of topics regarding the innovation via IT, few studies have dealt with the issue of could computing as IT. Thus, the purpose of this paper is to set the variables of innovation attributes based on the previous articles as the characteristic variables and clarify how these variables affect "Performance Expectancy" of companies and the intention of using cloud computing. The result from the analysis of data collected in this study is as follows. The study utilized a research model developed on the innovation diffusion theory to identify influences on the adaptation and spreading IT for cloud computing services. Second, this study summarized the characteristics of cloud computing services as a new concept that introduces innovation at its early stage of adaptation for companies. Third, a theoretical model is provided that relates to the future innovation by suggesting variables for innovation characteristics to adopt cloud computing services. Finally, this study identified the factors affecting expectation and the intention to use the cloud computing service for the companies that consider adopting the cloud computing service. As the parameter and dependent variable respectively, the study deploys the independent variables that are aligned with the characteristics of the cloud computing services based on the innovation diffusion model, and utilizes the expectation for performance and Intention to Use based on the UTAUT theory. Independent variables for the research model include Relative Advantage, Complexity, Compatibility, Cost Saving, Trialability, and Observability. In addition, 'Acceptance for Adaptation' is applied as an adjustment variable to verify the influences on the expected performances from the cloud computing service. The validity of the research model was secured by performing factor analysis and reliability analysis. After confirmatory factor analysis is conducted using AMOS 7.0, the 20 hypotheses are verified through the analysis of the structural equation model, accepting 12 hypotheses among 20. For example, Relative Advantage turned out to have the positive effect both on Individual Performance and on Strategic Performance from the verification of hypothesis, while it showed meaningful correlation to affect Intention to Use directly. This indicates that many articles on the diffusion related Relative Advantage as the most important factor to predict the rate to accept innovation. From the viewpoint of the influence on Performance Expectancy among Compatibility and Cost Saving, Compatibility has the positive effect on both Individual Performance and on Strategic Performance, while it showed meaningful correlation with Intention to Use. However, the topic of the cloud computing service has become a strategic issue for adoption in companies, Cost Saving turns out to affect Individual Performance without a significant influence on Intention to Use. This indicates that companies expect practical performances such as time and cost saving and financial improvements through the adoption of the cloud computing service in the environment of the budget squeezing from the global economic crisis from 2008. Likewise, this positively affects the strategic performance in companies. In terms of effects, Trialability is proved to give no effects on Performance Expectancy. This indicates that the participants of the survey are willing to afford the risk from the high uncertainty caused by innovation, because they positively pursue information about new ideas as innovators and early adopter. In addition, they believe it is unnecessary to test the cloud computing service before the adoption, because there are various types of the cloud computing service. However, Observability positively affected both Individual Performance and Strategic Performance. It also showed meaningful correlation with Intention to Use. From the analysis of the direct effects on Intention to Use by innovative characteristics for the cloud computing service except the parameters, the innovative characteristics for the cloud computing service showed the positive influence on Relative Advantage, Compatibility and Observability while Complexity, Cost saving and the likelihood for the attempt did not affect Intention to Use. While the practical verification that was believed to be the most important factor on Performance Expectancy by characteristics for cloud computing service, Relative Advantage, Compatibility and Observability showed significant correlation with the various causes and effect analysis. Cost Saving showed a significant relation with Strategic Performance in companies, which indicates that the cost to build and operate IT is the burden of the management. Thus, the cloud computing service reflected the expectation as an alternative to reduce the investment and operational cost for IT infrastructure due to the recent economic crisis. The cloud computing service is not pervasive in the business world, but it is rapidly spreading all over the world, because of its inherited merits and benefits. Moreover, results of this research regarding the diffusion innovation are more or less different from those of the existing articles. This seems to be caused by the fact that the cloud computing service has a strong innovative factor that results in a new paradigm shift while most IT that are based on the theory of innovation diffusion are limited to companies and organizations. In addition, the participants in this study are believed to play an important role as innovators and early adapters to introduce the cloud computing service and to have competency to afford higher uncertainty for innovation. In conclusion, the introduction of the cloud computing service is a critical issue in the business world.

  • PDF

EU's Space Code of Conduct: Right Step Forward (EU의 우주행동강령의 의미와 평가)

  • Park, Won-Hwa
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.27 no.2
    • /
    • pp.211-241
    • /
    • 2012
  • The Draft International Code of Conduct for Outer Space Activities officially proposed by the European Union on the occasion of the 55th Session of the United Nations Peaceful Uses of the Outer Space last June 2012 in Vienna, Austria is to fill the lacunae of the relevant norms to be applied to the human activities in the outer space and thus has the merit our attention. The missing elements of the norms span from the prohibition of an arms race, safety and security of the space objects including the measures to reduce the space debris to the exchange of information of space activities among space-faring nations. The EU's initiatives, when implemented, cover or will eventually prepare for the forum to deal with such issues of interests of the international community. The EU's initiatives begun at the end of 2008 included the unofficial contacts with major space powers including in particular the USA of which position is believed to have been reflected in the Draft with the aim to have it adopted in 2013. Although the Code is made up of soft law rather than hard law for the subscribing countries, the USA seems to be afraid of the eventuality whereby its strategic advantages in the outer space will be affected by the prohibiting norms, possibly to be pursued by the Code from its current non-binding character, of placing weapons in the outer space. It is with this trepidation that the USA has been opposing to the adoption of the United Nations Assembly Resolutions on the prevention of an arms race in the outer space (PAROS) and in the same context to the setting-up of a working group on the arms race in the outer space in the frame of the Conference on Disarmament. China and Russia who together put forward a draft Treaty on Prevention of the Placement of Weapons in Outer Space and of the Threat or Use of Force against Outer Space Objects (PPWT) in 2008 would not feel comfortable either because the EU initiatives will steal the lime light. Consequently their reactions are understandably passive towards the Draft Code while the reaction of the USA to the PPWT was a clear cut "No". With the above background, the future of the EU Code is uncertain. Nevertheless, the purpose of the Code to reduce the space debris, to allow exchange of the information on the space activities, and to protect the space objects through safety and security, all to maximize the principle of the peaceful use and exploration of the outer space is the laudable efforts on the part of EU. When the detailed negotiations will be held, some problems including the cost to be incurred by setting up an office for the clerical works could be discussed for both efficient and economic mechanism. For example, the new clerical works envisaged in the Draft Code could be discharged by the current UN OOSA (Office for Outer Space Affairs) with minimal additional resources. The EU's initiatives are another meaningful contribution following one due to it in adopting the Kyoto Protocol of 1997 to the UNFCCC (UN Framework Convention on the Climate Change) and deserve the praise from the thoughtful international community.

  • PDF

The National Survey of Acute Respiratory Distress Syndrome in Korea (급성호흡곤란증후군의 전국 실태조사 보고)

  • Scientific Subcommittee for National Survey of Acute Respiratory Distress Syndrome in Korean Academy of Tuberculosis and Respiratory Disease
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.25-43
    • /
    • 1997
  • Introduction : The outcome and incidence of acute respiratory distress syndrome (ARDS) could be variable related to the varied definitions used for ARDS by researchers. The purpose of the national survey was to define the risk factors of ARDS and investigate the prognostic indicies related to mortality of ARDS in Korea according to the definition of ARDS determined by the American-European Concensus Conference on 1992 year. Methods : A Multicenter registry of 48 University or University-affliated hospital and 18 general hospital s equipped with more than 400 patient's beds conducted over 13 months of patients with acute respiratory distress syndrome using the same registry protocol. Results : 1. In the 12 months of the registry, 167 patients were enrolled at the 24 hospitals. 2. The mean age was 56.5 years (${\pm}17.2$ years) and there was a 1.9:1 ratio of males to females. 3. Sepsis was the most common risk factors (78.1%), followed by aspiration (16.6%), trauma (11.6%), and shock (8.5%). 4 The overall mortality rate was 71.9%. The mean duration was 11 days (${\pm}13.1$ days) from the diagnosis of ARDS to the death. Respiratory insufficiency appeared to be a major cause in 43.7% of the deaths followed by sepsis (36.1%), heart failure (7.6%) and hepatic failure (6.7%). 5. There were no significant differences in mortality based on sex or age. No significant difference in mortality in infectious versus noninfectious causes of ARDS was found. 6. There were significant differences in the pulse rate, platelet numbers, serum albumin and glucose levels, the amounts of 24 hour urine, arterial pH, $Pa0_2$, $PaCO_2$, $Sa0_2$, alveolar-arterial oxygen differences, $PaO_2/FIO_2$, and PEEP/$FI0_2$ between the survivors and the deaths on study days 1 through 6 of the first week after enrollment. 7. The survivors had significantly less organ failure and lower APACHE III scores at the time of diagnosis of ARDS (P<0.05). 8. The numbers of organ failure (odd ratio 1.95, 95% confidence intervals:1.05-3.61, P=0.03) and the score of APACHE III (odd ratio 1.59, 95% confidence interval:1.01-2.50, P=0.04) appeared to be independent risk factors of the mortality in the patients with ARDS. Conclusions : The mortality was 71.9% of total 167 patients in this investigation using the definition of American-European Consensus Conference on 1992 year, and the respiratory insufficiency was the leading cause of the death. In addition, the numbers of organ failure and the score of APACHE III at the time of diagnosis of ARDS appeared to be independent risk factors of the mortality in the patients with ARDS.

  • PDF

A study on the ecological habitat and protection of natural Sorbus commixta forest at Mt. Seorak (설악산(雪嶽山)에 분포(分布)하는 마가목 천연림(天然林)의 생태환경(生態環境)과 보호(保護)에 관(關)한 연구(硏究))

  • Shin, Jai Man;Kim, Tong Su;Han, Sang Sup
    • Journal of Forest and Environmental Science
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 1983
  • The purpose of this study was to elucidate the ecophysiological habitat of natural Sorbus commixta forest at Mt. Seorak. The results obtained were as follows: 1. The Sorbus commixta trees mainly distributed from 900m to 1,500m altitude. In there, the warm index(WI) was about 42$3.2{\times}10^3$ to $9.2{\times}10^3$, cation exchange capacity(CEC) was 13.7 to 19.5mg/100g, N content 0.21 to 0.39%, $P_2O_5$ content was 22.6 to 38.7ppm, and pH value was 5.6 to 5.8 respectively. 4. The upper crown trees in Sorbus commixta communities were Abies nephrolepis, Taxus cuspidata, Betula platyphylla var. japonica, Quercus${\times}$grosseserrata, Acer mono, Prunus sargentii, Carpinus cordata, Tilia amurensis, and the under crown trees were Rhododendron brachycarpum, Acer pseudo-sieboldianum, Thuja olientalis, Corylus heterohpylla, Philadelphus schrenckii, Rhododendron schlippenbachii, Rhododendron mucronulatum, and Magnolia sieboldii. 5. The stand densities were 1,156 trees/ha at 1,160m and 3,600 trees/ha at 1,300m respectively. The coverages by the DBH basal area were 0.37 at 1,160m and 0.31 at 1,300m respectively, and the vegetation coverages by the crown projection area were 2.04 at 1,160m and 1.61 at 1,300m respectively. 6. The light extinction coefficient(k) in Beer-Lambert's law, showed the distance, F(z), from top canopy to aboveground, was 0.17. 7. The water relations parameters of Sorbus commixta shoot were obtained by the pressure chamber technique. The osmotic pressure, ${\pi}_o$, at maximum turgor was -16.2 bar, and VAT pressure was 14.5bar. The osmotic pressure, ${\pi}_p$, at incipient plasmolysis was -19.4bar. The relative water contents at incipient plasmolysis were 83.1% ($v_p/v_o$) and 87.1%($v_p/w_s$;$w_s$, total water at maximum turgor). 8. The bulk modulus of elasticity(E) of shoot was about 69.6. The total symplasmic water to total water in shoot was 67.7%, and the apoplastic water to total water was 32.3%.

  • PDF

The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.