• Title/Summary/Keyword: puncture test

Search Result 87, Processing Time 0.029 seconds

Texture Properties of Acorn Starch Gels -Puncture test, Back extrusion test and Retrogradation test- (도토리묵의 텍스쳐 특성 -관통시험, 역압출시험, 노화특성시험-)

  • 김영아
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.20 no.2
    • /
    • pp.173-178
    • /
    • 1991
  • The rheological properties of acorn crude starch gel and refined starch gel were investigated by puncture test, back-extrusion test and retrogradation test. Puncture test was a useful method to compare the different gel type and concentration, and to calculate the compression and shear coefficient. Maximum extrustion force and adhesiveness were also examined by performing back-extrustion test. The retrogradation rate was analysed by Avrami equation in retrogradation test.

  • PDF

Rheological Properties of Acorn Flour Gels - Puncture Test and Back Extrusion Test - (도토리묵의 물리적 특성 -Puncture test 와 Back Extrusion test-)

  • Kim, Young-A;Rhee, Hei-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.469-473
    • /
    • 1985
  • The typical force-distance curves by puncture test and Back Extrusion test of acorn flour gels were investigated. Kc' and Ks' were calculated to estimate the compression and shear components of a puncture force. In this study, compression effect played a major role. The more concentration of acorn flour gel and diameter of probe increased, the more compression force contributed to the puncture force. In the Back Extrusion test, the effect of increasing the sample size was to extend the length of the plateau without affecting the maximum force. However, as the concentration of acorn flour gel increased, maximum Extrusion force became larger.

  • PDF

Puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study

  • Son, Il Wan;Kim, Suk;Hong, Seung Baek;Lee, Nam Kyung;Jeong, Mi Ri;Han, Sung Yong;Woo, Hyun Young
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.1
    • /
    • pp.18-23
    • /
    • 2022
  • Background: This study was performed to evaluate periprocedural factors, complications, and repuncture rate of the newly developed puncture needle and compare it with the routinely used puncture needle for ultrasound (US)-guided paracentesis. Methods: We retrospectively identified 137 patients who underwent US-guided paracentesis between July 2018 and March 2019. Among them, 82 patients underwent US-guided paracentesis with a newly developed puncture needle. The other 55 patients underwent US-guided paracentesis with a routinely used puncture needle. The periprocedural factors, complications, and repuncture rate were compared between the two groups using the Mann-Whitney U test and Fisher exact test. The repuncture-associated factors were assessed using logistic regression analysis. Results: There were no major or minor complications in either group. The rate of repuncture was significantly lower in the group using the newly developed puncture needle compared with the group using the routinely used puncture needle (p=0.01). The duration of the procedure was significantly shorter with the newly developed puncture needle compared with the routinely used puncture needle (p=0.01). In univariate analysis, the thickness of the abdominal wall (p=0.04) and the use of the newly developed puncture needle (p=0.01) were significantly associated with the rate of repuncture. In multivariate analysis, only the use of the newly developed puncture needle was significantly associated with the rate of repuncture. Conclusion: Using this novel puncture needle with a hard plastic sheath and plastic wings, the rate of repuncture and the duration of the procedure were decreased without complications of US-guided paracentesis.

The Measurment Methods of the Textural Characteristics of Fermented vegetables (침채류의 조직감 측정방법)

  • 이희섭
    • Korean journal of food and cookery science
    • /
    • v.11 no.1
    • /
    • pp.83-91
    • /
    • 1995
  • For the accurate interpretation and objective measurement of textural characteristics of fermented vegetables, first of all, the studies on the microstructure and chemical compositions of vegetable cell, and the changes in the textural properties of vegetables during salting, blanching and fermentation should be carried out. And the mechanical textural parameters were needed to compare with and analyze in relation to the sensory parameters. In this review, the thypical force-distance curves of fermented vegetables were obtained from the compression, cutting and puncture test. And it was showed that the compression force was a more effective textural parameter to express the hardness of fermented vegetables, and the sensory chewiness and toughness were related to the changes in cutting force. In the puncture test, the puncture force was related to the hardness and varied with the size and form of puncture probe; the changes in puncture force by small probe could express the decrease in hardness and crispness, whereas those by large probe could represent the changes in toughness. And the brittleness and crispness could be measured by the break point and the numbers of peak obtained from the force-distance curves.

  • PDF

A mite Element Modeling for the Puncture Drop Test of a Cask with the Failure of Impact Limiter (충격완충체의 효과를 고려할 수 있는 운반용기의 파열낙하시험 유한요소해석 방법)

  • Kwon, Kie-Chan;Seo, Ki-Seog;You, Gil-Sung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.1
    • /
    • pp.9-16
    • /
    • 2009
  • Transport package for radioactive material should be structurally safe under puncture drop condition and its safety should be verified by test and numerical analysis. Most finite element analyses for puncture drop have been performed without modeling the impact limiter since failure is occurred in the materials of the impact limiter. This paper presents a new modeling methodology, where an element is eroded in case that the material's failure criteria are reached at the element's integration point, to investigate the effect of the impact limiter in the puncture process. The effectiveness of the proposed scheme is shown through the puncture drop analysis of hotcell transport cask, which is under design in KAERI. The results show that about 80 percent of the total impact energy is absorbed due to the deformation of impact limiter. Using the present method the puncture drop can be analyzed more accurately, but it would give conservative results compared to the actual test condition.

  • PDF

The Efect of Cutaneus Stimulation on AV Fistula Puncture Pain of Hemodialysis Patients (피부자극이 혈액투석환자의 동정맥루 천자시 동통감소에 미치는 영향)

  • Park, Jeong-Sook
    • The Korean Nurse
    • /
    • v.33 no.1
    • /
    • pp.37-51
    • /
    • 1994
  • The cutaneous stimulation is an independent nursing intervention used in various painful conditions, and is explained by gate control theory. This study was aimed at identifying the effect of cutaneous stimulation on reduction of arteriovenous fistula puncture pain of hemodialysis patients. One group repeated measurement post test research was designed. Forty-five hemodialysis patients who received arteriovenous fistula puncture regulary in hemodialysis units of an attacted D hospital to K university have been studied from August 16 to 21, 1993. First the arteriovenous fistula puncture pain of control period was measured, and then the arteriovenous fistula puncture pain of experimental period(with cutaneous stimulation) was measured. The instrument used for this study were visual analogue pain scale as subjective pain measurement, objective pain behavior checklist and Spielberger's Trait Anxiety Inventory as intervening variables. Analysis of data was done by use of paired t-test, t-test, ANOVA and Perarson correlation coefficient. The results of this study were summarized as follows; 1) The first hypothesis that the subjective pain score of arteriovenous fistula puncture pain in experimental period(with cutaneous stimulation) will be lower than in control period was partly supported. The subjective pain score of arterial line was rejected(paired t=-0.28, p=0.77) and the subjective pain score of venous line was supported(paired t=2.61, p=0.01). 2) The second hypothesis that the objective pain behavior score of arteriovenous fistula pain in experimental period(with cutaneous stimulation) will be lower than in control period was rejected(arterial line paired t=-0.45, p=0.65; venous line paired t=-0.36, p=0.72). 3) The third hypothesis that the cardiopulmonary signs of arteriovenous fistula puncture pain in experimental period(with cutaneous stimulation) will be lower than in control period was rejected(pulse paired t=-0.8, p=0.42; systolic BP paired t=0.98, p=0.33; diastolic BP paired t=0.43, p=0.66). Further experimental studies with simple intravenous injection patients will be recommended in order to identify the effect of cutaneous stimulation.

  • PDF

Resistant Effects of Geosynthetics Against Puncture Loads as a Protective of HDPE (차수재(HDPE) 보호재로서 토목섬유의 천공(꿰뚫림)하중에 대한 저항효과)

  • 이광열;장삼식;구태곤
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.11-17
    • /
    • 2004
  • This study focused on the protection effects of geosynthetics installed on HDPE to resist against puncture loads. The study was conducted by a model test with various types of puncture loads created by different shapes of tools. The puncture resistance of geosynthetics installed as a protective material on HDPE is varied depending on the sizes of geosynthetics and types of puncture loads. In this study, it was found that the protection effect far all kinds of geosynthetics when a truncated cylindrical shape of puncture tool is used is lower than others. Also, geocomposite has the most excellent protection effect against all types of puncture loads.

Suspension insulator development of Epoxy casting Bar-Type (에폭시 BAR-TYPE 배전용 현수애자 개발)

  • Kim, J.Y.;Song, I.K.;Kim, S.J.;Kwon, D.J.;Kim, S.K.;Kwak, H.R.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1529-1531
    • /
    • 1996
  • Porcelain suspension insulators have teen used for a long time in distribution line. However, Puncture breakdowns in porcelain insulators caused by weaking cement between metal fitting nad porcelain material. There is little puncture breakdown in Epoxy casting insulator. This paper presents electrical test results for the development of suspension insulator used Cycloaliphatic Epoxy resin. Items of test results are as follow - Power Arc test - Aging test - Impulse flashover voltage tests - Puncture tests et.al.

  • PDF

Texture of Chewing Gum: Instrumental and Sensory Rheological Characteristics (츄잉검의 텍스쳐 : 기계적(機械的) 물성(物性)과 관능적(官能的) 특성(特性))

  • Pyun, Yu-Ryang;Yoo, Myung-Shik;Lee, Yoon-Hyung
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.303-308
    • /
    • 1984
  • Instrumental and sensory characteristics of chewing gums were measured at each masticatory stage, and the correlations between the characteristics were analyzed. In instrumental characteristics, similarities were proved between initial puncture work and puncture force, intermediate hardness and penetration work, final hardness and penetration work, and adhesion work and adhesion force. Final hardness correlated highly with yield force and the slope of force-distance curve of penetration test, and the slope also correlated significantly with springiness and adhesion force. In sensory characteristics, the correlations of the same parameter between trained panel and consumer were extremely high. Initial stiffness correlated significantly with both intermediate and final firmness by consumer. Highly significant correlations were obtained between final firmness and stiffness and between lift and cohesion by trained panel, whereas firmness correlated with adhesion negatively.

  • PDF

Character Analysis that influences to Surgical Gloves Punctures (수술장갑의 천공에 영향을 미치는 특성 분석)

  • Kim, Eu Jin;Koh, Myung Suk
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.1
    • /
    • pp.99-110
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the puncture incidence of surgical gloves in an operational setting. Methods: The 277 surgical gloves were used collecting at one general hospital located in Seoul from February 1, 2011 to April 3. The data were analyzed by $x^2$ test, Fisher's exact test, and multiple logistic regression. Results: In the dental and orthopedic department, the puncture incidence were significantly higher than others. The time of wearing gloves demonstrated significant difference: The group 181-240 minutes had a significantly higher than those with under 90, 91-180, or over 240 minutes. The influencing factors were as follows. Compared to that of the 2nd assistants, the puncture incidence rates of the surgeons were 9.91 times, scrub nurses were 8.39 times higher respectively. The participants in work experience under 1 year showed a 4.58 times higher than those with over 7 years. In addition, compared to the puncture incidence rate of neurosurgery department, the 17.41 times in cardio-thoracic surgery, 13.89 times in dental surgery, 4.93 times in gynecology, and 4.97 times in orthopedics higher respectively. Conclusion: There is a need for training operational room personnels to occasionally exchange the gloves even during the procedure and to use double surgical gloves.