• 제목/요약/키워드: pumping rates

검색결과 113건 처리시간 0.031초

나노 파운틴펜의 동적해석에 관한 연구 (A Study on Dynamic Analysis of Nano Fountain Pen)

  • 이영관;김훈모;김윤제;이석한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.922-929
    • /
    • 2006
  • In this study, flow characteristics of the FPN (Fountain Pen Nano-Lithography) using active membrane pumping are investigated. This FPN has integrated chamber, micro channel, and high capacity reservoir for continuous ink feed. The most important aspect in this probe provided control of fluid injection using active membrane pumping in chamber. The flow rates in channel by capillary force are theoretically analyzed, including the control of mass flow rates by deflection of membrane. The above results are compared with numerical simulations that calculated by commercial code, FLUENT. The velocity of fluid in micro channel shows linear behaviors. And the mass flows are proportional to the second order function of pumping pressure that is imposed to membrane.

  • PDF

Physical Model Investigation of a Compact Waste Water Pumping Station

  • Kirst, Kilian;Hellmann, D.H.;Kothe, Bernd;Springer, Peer
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.285-291
    • /
    • 2010
  • To provide required flow rates of cooling or circulating water properly, approach flow conditions of vertical pump systems should be in compliance with state of the art acceptance criteria. The direct inflow should be vortex free, with low pre-rotation and symmetric velocity distribution. Physical model investigations are common practice and the best tool of prediction to evaluate, to optimize and to document flow conditions inside intake structures for vertical pumping systems. Optimization steps should be accomplished with respect to installation costs and complexity on site. The report shows evaluation of various approach flow conditions inside a compact waste water pumping station. The focus is on the occurrence of free surface vortices and the evaluation of air entrainment for various water level and flow rates. The presentation of the results includes the description of the investigated intake structure, occurring flow problems and final recommendations.

소형관정의 양수효율 (Pumping Efficiency of the Small Size Tube Well)

  • 정재훈;박승기;강성민;이승기
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.221-224
    • /
    • 2002
  • The analysis of characteristics of pumping in the small tube well for agriculture were surveyed. Study area was located at the Galsinri in Yesangun near the yedang reservoir. Agricultural electricity using rates for pumping, ground water level and volume of pumping was monitored every week. Pump working ratio and pump efficiency during period of transplanting of rice showed 48.5%, 58.4% respectively.

  • PDF

농업용 소형 관정의 양수 특성 (Characteristics of Pumping in Small Tube Wells for Agricultural)

  • 정재훈;황무석;박승기;이승기
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.106-109
    • /
    • 2001
  • The analysis of characteristics of pumping in the small tube well for agriculture were surveyed. Study area was located at the Galsinri in Yesangun near the yedang reservoir. Agricultural electricity using rates for pumping, ground water level and volume of pumping was monitored every week. Pump working ratio and pump efficiency during period of transplanting of rice showed 48.9%, 62.7% respectively.

  • PDF

지하수위를 고려한 양수량 추정

  • 박승기;이승기;정재훈;강성민
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.13-16
    • /
    • 2002
  • The analysis of characteristics of pumping in the small tube well for agriculture were surveyed. Study area was located at the Galsinri in Yesangun near the yedang reservoir. Agricultural electricity using rates for pumping, ground water level and volume of pumping was monitored every week. Pump working ratio and pump efficiency during period of transplanting of rice showed 48.9%, 62.7% respectively.

  • PDF

능동적 박막 펌핑에 의한 파운틴 펜 나노 리소그래피 유동 특성에 관한 연구 (A Study on Flow Characteristics of Fountain-pen Nano-Lithography with Active Membrane Pumping)

  • 이진형;이영관;이성근;이석한;김윤제;김훈모
    • 대한기계학회논문집B
    • /
    • 제30권8호
    • /
    • pp.722-730
    • /
    • 2006
  • In this study, the flow characteristics of a FPN (Fountain Pen Nano-Lithography) using active membrane pumping are investigated. The FPN has integrated chamber, micro channel, and high capacity reservoir for continuous ink feed. The most important aspect in this probe provided control of fluid injection using active membrane pumping in chamber. The flow rates in channel by capillary force are theoretically analyzed, including the control of the mass flow rates by the deflection of the membrane. The above results are compared with the numerical simulations that calculated by commercial code, FLUENT. The velocity of the fluid in micro channel shows linear behaviors. And the mass flows are proportional to the second order function of the pumping pressure that is imposed to the membrane.

해석적 모형을 이용한 주기적 지하수 양수가 하천의 수량에 미치는 장기 영향 분석 (Evaluation of long-term stream depletion due to cyclic groundwater pumping using analytical model)

  • 이정우;정일문;김남원
    • 한국수자원학회논문집
    • /
    • 제52권7호
    • /
    • pp.483-492
    • /
    • 2019
  • 대수층과 하상의 수리특성을 고려하여 유도된 Hunt 해석해에 영상정과 중첩원리를 적용하여 양수 및 중단을 반복하는 주기적 지하수 양수로 인한 하천수 감소량을 산정할 수 있는 해석적 모형을 개발하고, 이를 활용하여 관개기 지하수 양수에 따른 하천수량에 미치는 장기 영향을 분석하였다. 대수층과 하상의 다양한 수리특성값과 하천-관정 이격거리 조합에 따라 총 1,500 가지 조건에 대해 10년 양수시 하천수 감소량을 산정하고 그 결과를 도시적으로 나타내었으며, 특히 양수기간동안 최대 및 평균 하천수 감소율의 거동 특성을 연속적인 양수의 결과와 비교, 분석하였다. 또한, 하천수 감소율과 농업용수 회귀율을 함께 고려하여 하천수량 측면에서 관개기 지하수 양수 영향을 최소화할 수 있는 한계수리조건을 제시하였다.

Numerical Simulation of Water Table Drawdown due to Groundwater Pumping in a Contaminated Aquifer System at a Shooting Test Site, Pocheon, Korea

  • Kihm, Jung-Hwi;Hwang, Gisub
    • 자원환경지질
    • /
    • 제54권2호
    • /
    • pp.247-257
    • /
    • 2021
  • The study area has been contaminated with explosive materials and heavy metals for several decades. For the design of the pump and treat remediation method, groundwater flow before and during groundwater pumping in a contaminated aquifer system was simulated, calibrated, and predicted using a generalized multidimensional hydrological numerical model. A three-dimensional geologic formation model representing the geology, hydrogeology, and topography of the aquifer system was established. A steady-state numerical simulation with model calibration was performed to obtain initial steady-state spatial distributions of groundwater flow and groundwater table in the aquifer system before groundwater pumping, and its results were illustrated and analyzed. A series of transient-state numerical simulations were then performed during groundwater pumping with the four different pumping rates at a potential location of the pumping well. Its results are illustrated and analyzed to provide primary reference data for the pump and treat remediation method. The results of both steady-state and transient-state numerical simulations show that the spatial distribution and properties of the geologic media and the topography have significant effects on the groundwater flow and thus depression zone.

강변여과 취수정의 간섭효과와 하천수 비율에 대한 해석적 평가 (Analytical Evaluation of Interference and Ratio of River Water at Riverbank Filtration Pumping Wells)

  • 박남식
    • 한국수자원학회논문집
    • /
    • 제47권8호
    • /
    • pp.685-691
    • /
    • 2014
  • 강변여과는 하천 인근에 다수의 관정을 설치하여 하천수의 수질 개선을 추구하는 기술이다. 그런데 다수의 관정이 인접해 있는 경우 관정간의 상호간섭 현상으로 인하여 취수량에 영향을 미친다. 강변 여과 관정의 경우에는 관정이 관망으로 연결되기 때문에 간섭효과의 요인에는 지하수위 강하량 외에도 유량변화에 따른 관망 수두손실이 포함된다. 간섭효과는 취수정으로 유입되는 하천수와 배후 지하수의 비율에도 영향을 미친다. 본 연구에서는 강변여과시스템의 대수층과 관망흐름을 통합해석하는 기법을 이용하여 복수 관정의 간섭효과와 하천수 비율을 산정하는 방법을 제시하고 실제에 가까운 가상의 강변여과시스템에 적용하였다. 관정 가동 패턴에 따라 취수량은 5% 이상 차이가나고 배후지하수 유입비율도 30~40% 범위로 10% 이상 차이가 날 수 있는 것으로 나타났다.

Analytical Solution for Flow Field by Arbitrarily-Located Multi Injection-Pumping Wells

  • Yoo, In-Wook;Lee, Kang-Kun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.79-82
    • /
    • 2001
  • Analytical solutions have been derived to delineate the capture zone created by pumping wells for the remediation design of contaminated groundwater. These previous analytical solutions are often restricted to pumping wells only, specific well locations, a limited number of wells, and an isotropic aquifer. Analytical solution was developed to deal with arbitrarily located multi injection-pumping wells in an anisotropic homogeneous aquifer. The solution presented in this study provides a simple, easy method for determining tile complex flow field caused by multi injection-pumping wells at different rates, and will consequently be useful in pump-and-treat design.

  • PDF