• Title/Summary/Keyword: pump pressure

Search Result 1,491, Processing Time 0.028 seconds

Experimental Performance Study of the Bubble Pump for the Diffusion Absorption Refrigerating System (확산형 흡수식 냉동시스템의 기포펌프 성능실험)

  • 이재효;정의갑;윤재호;정의갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.287-292
    • /
    • 2004
  • An experimental investigation was carried out to study the performance of a bubble pump for the diffusion absorption refrigerating system. Ammonia was used as the refrigerant and the helium was charged in order to balance the pressure between the low and high pressure side. As experimental variables, the concentration of ammonia charged into system, heat input, and the pressure of helium were selected. Experimental results show that the generation rate of ammonia vapor and the circulation rate of diluted ammonia solution were increased as the heat input increases, but the ratio of the solution to vapor flow rate was decreased. The generation rate of refrigerant vapor and the circulation rate of diluted ammonia solution increased as the system pressure decreased. Finally under the condition of 25 bars, the concentration of rich ammonia solution was not affected by the generation rate of ammonia vapor and the circulation of diluted ammonia solution.

An Experimental Study on the Pumping Performance of Molecular Drag Pumps

  • Kwon, Myoung-Keun;Hwang, Young-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.9
    • /
    • pp.1483-1491
    • /
    • 2006
  • The pumping performance of molecular drag pumps (MDP) has been investigated experimentally. The exporimented MDPs are a disk-type drag pump (DTDP), helical-type drag pump(HTDP) and compound drag pump (CDP), respectively In the case of the DTDP, spiral channels of a rotor are cut on both upper surface and lower surface of a rotating disk, and the corresponding stator is a planar disk. In the case of the HTDP, the rotor has six rectangular grooves. The CDP consists with the DTDP, at lower part, and with the HTDP, at upper part. The experiments are performed in the outlet pressure range of $0.2{\sim}533Pa$. The inlet pressure and compression ratio are measured under the various conditions of outlet pressure and throughputs, and nitrogen is used for the test gas. At the outlet pressure of 0.2Pa, the ultimate pressure has been reached to $1.0{\times}10^{-2}Pa$ for the HTDP, $1.3{\times}10^{-4}Pa$ for the DTDP, and $3.6{\times}10^{-5}Pa$ for the CDP. The maximum compression ratio of the CDP is much higher than those of the DTDP or HTDP. Consequently, the ultimate pressure of the CDP is the lowest one.

Electrohydraulic Pump-Driven Closed-Loop Blood Pressure Regulatory System

  • Ahn, Jae-Mok
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.449-454
    • /
    • 2007
  • An electrohydraulic (EH) pump-driven closed-loop blood pressure regulatory system was developed based on flow-mediated vascular occlusion using the vascular occlusive cuff technique. It is very useful for investigating blood pressure-dependant physiological variability, in particular, that could identify the principal mediators of renal autoregulation, such as tubuloglomerular feedback (TGF) and myogenic (MYO), during blood pressure regulation. To address this issue, renal perfusion pressure (RPP) should be well regulated under various experimental conditions. In this paper, we designed a new EH pump-driven RPP regulatory system capable of implementing precise and rapid RPP regulation. A closed-loop servo-controlwas developed with an optimal proportional plus integral (PI) compensation using the dynamic feedback RPP signal from animals. An in vivo performance was evaluated in terms of flow-mediated RPP occlusion, maintenance, and release responses. Step change to 80 mmHg reference from normal RPP revealed steady state error of ${\pm}3%$ during the RPP regulatory period after PI action. We obtained rapid RPP release time of approximately 300 ms. It is concluded that the proposed EH RPP regulatory system could be utilized in in vivo performance to study various pressure-flow relationships in diverse fields of physiology, and in particular, in renal autoregulation mechanisms.

Analysis of Forces Acting on Plunger in Radial Plunger Pump Considering Characteristics of Oil (유압유의 특성을 고려한 플런저 펌프의 작용력 해석)

  • 장윤석;박인규;임윤철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.151-158
    • /
    • 2001
  • This paper presents a method for evaluating the lubrication characteristics between the plunger and cylinder in a radial type plunger pump. A numerical analysis is carried out in order to obtain the pressure distribution and acting forces between the plunger and cylinder. The pressure distribution is also measured experimentally by using pressure transducer through the cam type test machine. The experimental pressure distribution result is compared with the numerical result which is estimated by the computer simulation. In conclusion, the acting forces to the plunger are expressed for the operating conditions such as clearance, supply pressure, rotation speed and viscosity of oil.

  • PDF

The Lubrication Characteristics of the Vane Tip Under Pressure Boundary Condition of Oil Hydraulic Vane Pump

  • Cho Ihn-Sung;Oh Seok-Hyung;Song Kyu-Keun;Jung Jae-Youn
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.10
    • /
    • pp.1716-1721
    • /
    • 2006
  • The Lubrication Mode of line contacts between the vane and the camring in an oil hydraulic vane pump has been investigated. First, the variations of the radial force of a vane were calculated from previous measurements of dynamic internal pressure in four chambers surrounding a vane. Next, the lubrication modes were distinguished with Hooke's chart, which is an improvement over Johnson's chart. Finally, the influence of the boundary conditions in the lubrication region on the fluid film lubrication was examined by calculating the film pressure distributions. The results showed that the lubrication mode of the vane tip exists in the rigid-variable-viscosity region, and that discharge pressure higher than 7 MPa greatly affects the oil film pressure in the small and the large arc section because of the Piezo-viscous effect.

Pressure Pulsation Characteristics of a Model Pump-turbine Operating in the S-shaped Region: CFD Simulations

  • Xia, Linsheng;Cheng, Yongguang;Cai, Fang
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.3
    • /
    • pp.287-295
    • /
    • 2017
  • The most detrimental pressure pulsations in high-head pump-turbines is caused by the rotor-stator interaction (RSI) between the guide vanes and runner blades. When the pump-turbine operates in the S-shaped region of the characteristic curves, the deteriorative flow structures may significantly strengthen RSI, causing larger pressure pulsations and stronger vibration with an increased risk of mechanical failure. CFD simulations were carried out to analyze the impacts of flow evolution on the pressure pulsations in the S-shaped region of a model pump-turbine. The results show that the reverse flow vortex structures (RFVS) at the runner inlet have regular development and transition patterns when discharge reduces from the best efficiency point (BEP). The RFVS first occur at the hub side, and then shift to the mid-span near the no-load point, which cause the strongest pressure pulsations. The locally distributed RFVS at hub side enhance the local RSI and makes the pressure fluctuations at the corresponding sections stronger than those at the rest sections along the spanwise direction. Under the condition of RFVS at the mid-span, the smaller flow rate make the smaller difference of pressure pulsation amplitudes in the spanwise direction. Moreover, the rotating stall, rotating at 35.7%-62.5% of the runner rotational frequency, make the low frequency components of pressure pulsations distribute unevenly along the circumference in the vaneless space. However, it have little influence on the distributions of high components.

Study on the fuel rail temperature and pressure characteristics with LPG composition during hot restart condition of LPi engine with turbine type pump (터빈방식 펌프 LPi연료공급 시스템의 엔진 고온재시동 시 LPG 조성비에 따른 연료레일에서의 압력 및 온도특성에 관한 연구)

  • Lee, Kang-Ju;Kim, Ju-Won;Myung, Cha-Lee;Park, Sim-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3323-3328
    • /
    • 2007
  • Conventional LPG pump for Liquified Petroleum injection(LPi) engine has been adopted vane type. But the BLDC type fuel pump for LPi system has complicated structure and its price is high. Therefore, as a alternative, this study has mainly focused on the development of turbine type LPG pump which has lower cost and simple structure than conventional BLDC type. To verify the possibility of substitute the performance tests were performed for each fuel pump. The comparative items were pressure settling time, variation of fuel outlet temperature and engine performance of hot restart ability. As a result, performances of turbine type LPG pump were equivalent or high comparing to the BLDC type all over the tests for different fuel composition.

  • PDF

Development of Computer Program for Design of the Small Annular Linear Induction EM Pump (소형 환단면 선형유도전자펌프 설계를 위한 전산 프로그램 개발)

  • Kim, H.R.;Nam, H.Y.;Hwang, J.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.137-140
    • /
    • 2002
  • EM(ElectroMagnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). In the present study, computer program for the pilot annular linear EM pump has been developed for the maximum flowrate with 200 l/min and maximum developing pressure with 3 bar. Firstly, Balance equation is induced by the equivalent circuit method which is commonly employed to analyze linear induction machines and the calculation of the hydraulic pressure drop. Then, design equation is converted to the computer program and optimum pump variables are determined by this code. The code is verified by the comparative analysis with the characteristic of the commercialized pump.

  • PDF

Performance Characteristics of R134a Supercritical Heat Pump (R134a 냉매용 초임계 히트펌프의 성능 특성)

  • Choi, In-Soo
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.60-65
    • /
    • 2014
  • In this paper, cycle performance analysis for heating capacity, compression work and COP of R134a supercritical heat pump is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature in the R134a supercritical heat pump system. The main results were summarized as follows : Superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature of R134a heat pump system have an effect on the heating capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the supercritical heat pump using R134a. The prediction for COP of R134a supercritical heat pump have been proposed through multiple regression analysis.

A Soft Actuation System with Origami Pump for Maximizing Haptic Feedback (햅틱 피드백 극대화를 위한 오리가미 펌프 기반의 소프트 구동기 시스템)

  • Jung, Pyeong-Gook;Jang, Hyukjoon;Cha, Youngsu
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.1
    • /
    • pp.29-34
    • /
    • 2021
  • Traditional actuation system such as electric and pneumatic actuator has obvious advantages and disadvantages. To combine advantages and compensate disadvantages of the traditional actuation, a pneumatic actuation system with an internal air pressure source is noteworthy approach. In this paper, a soft pneumatic actuation system based on origami pump is described for haptic feedback glove. To improve wearability, an origami pump is introduced because the origami pump is much lighter than air compressor. The miniaturized electric actuation system is also designed with 3D printed planetary gear in order to reduce the volume of the system. To figure out the performance of the system, shrinkage distance of origami pump was measured with vision camera. The pressure in the origami pump was also estimated to understand the performance of the system.