• 제목/요약/키워드: pulses

검색결과 1,600건 처리시간 0.03초

『소문(素問)·육절장상론(六節藏象論)』의 인영(人迎)·촌구(寸口) 맥진(脈診)의 셈법과 활용에 대한 연구 (Counting Method and Application of Pulse-taking on both Carotid and Wrist Pulses in Suwen·LiuJieCangXiangLun)

  • 조학준
    • 대한한의학원전학회지
    • /
    • 제30권3호
    • /
    • pp.77-93
    • /
    • 2017
  • Objectives : Clear and detailed analysis on Pulse-taking on both Carotid and Wrist Pulses is an absolute prerequisite if it is to be applied in real practice or its practical value proven. Methods : The original notes found in Suwen and Lingshu, their translations, and conventional studies regarding Suwen LiuJieCangXiangLun's Pulse-taking are compared and analyzed to find cases within medical texts where this method was used and to get an idea of the direction taken by the conventional study. Results : The ilsung, esung, samsung, and sasung of Carotid (or wrist pulses) refers that the pulse is one-, two-, three-, four-fold in differences. Refrainment should be practiced while comparing carotid and wrist pulses. Rather, they need to be compared with their normal states. Used by Luo Tianyi in Ming Dunasty, this method of pulse-taking was used for (radial artery) when diagnosing and treating the degree of seriousness of food injury. The measurement of maximum blood flow velocity using TCD done recently proved the validity of this pulse-taking, and it's been used for alleviating hypertension or tinnitus through acupuncture, or abating intractable diseases (around carotid). Conclusions : The obscurity of the measuring method of this pulse-taking can be resolved, and the problem which occurs while comparing carotid and wrist pulses can be solved. Even though there are differences in opinion regarding the positions when comparing the two pulses, their practical values are acknowledged since their usages in diagnosis, treatments, experiments, and researches have yielded positive results to a degree. They may not be used that often, but they are nonetheless under utilization.

위상 변조 및 첩 보상에 의한 초단 펄스 발생 (Short Pulse Generation Based on Phase Modulation and Chirp Compensation)

  • 전희정;임용훈;서동선;명승일;김호영
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2002년도 제13회 정기총회 및 2002년도 동계학술발표회
    • /
    • pp.174-175
    • /
    • 2002
  • We generate short optical pulses of ∼ 6 picoseconds at 10 GHz by chirped pulse compression based on phase modulation and chirp compensation. In the suggested method, sinusoidally driven intensity and phase modulators generate chirped pulses which are subsequently suppressed by chirp compensation using a single mode fiber.

  • PDF

극초단펄스 전송을 위한 고차원펄스의 스펙트럼 대역 분석 (Bandwidth Analysis of High-order Pulse for the Transmission of Ultrashort Laser Pulses)

  • 전진성;조형래;오용선
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1999년도 춘계종합학술대회
    • /
    • pp.237-242
    • /
    • 1999
  • 본 논문에서는, 차수에 따라 체계적으로 변화하는 고차원펄스의 스펙트럼 특성을 이용하여 극초단 레이저펄스의 전송특성을 분석하였다. 부분응답시스템의 수정된 모델로부터 얻어지는 고차원펄스는 그 차수의 증가에 따라 FWHM폭이 현저히 감소하여 분석하고자 하는 극초단펄스의 형태에 근접하며, 그 스펙트럼과 전송대역폭도 차수에 따라 일률적으로 유도되므로 기존의 Gaussian 펄스나 Sech 펄스에 의한 근사화에 비하여 광범위하고 정확한 전송특성을 분석하는데 매우 유용함을 밝혔다. 우리는 부분응답시스템의 일반적 모델을 순환형으로 수정함으로써 정형화된 임의의 고차원펄스 형태를 얻어낼 수 있는 새로운 모델을 설계하였으며, 이를 이용하여 다양한 형태와 FWHM폭을 갖는 극초단 레이저펄스의 전송특성을 분석하는 새로운 방법을 제안하였다. 또한, 제안된 방법을 사용하여, 설정 펄스폭을 $\tau$=1(ps)으로 설정, 고차원펄스의 차수 n=1-100에서 얻어지는 FWHM 1(ps)-150(fs)의 극초단펄스의 스펙트럼을 제시하였고, 그 null-to-null 대역폭을 유도하였다. 전송특성은 레이저펄스의 보편적인 신호방식인 Unipolar 체계로 설정하여, 가능한 펄스간격에 따른 전력밀도스펙트럼을 유도하여 제시하였다. 이러한 결과는 기존의 실험결과와 일치함은 물론 레이저펄스 발생기술의 발달에 의하여 새로이 등장할 어떠한 형태와 폭을 갖는 극초단펄스에 대해서도 적용될 수 있다.

  • PDF

SF6 압력에 따른 결함별 부분 방전 펄스의 분포 분석 (Analysis on PD Pulse Distribution by Defects Depending on SF6 Pressure)

  • 김선재;조향은;정기우;길경석;김성욱
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.40-45
    • /
    • 2015
  • Electrode systems: a protrusion on conductor (POC), a protrusion on enclosure (POE), a crack in epoxy plate and a free particle (FP) were fabricated to simulate insulation defects in a gas insulated switchgear (GIS). $SF_6$ gas was filled in the electrode systems by 3 bar and/or 5 bar, respectively. Partial discharge (PD) pulses were detected through a $50{\Omega}$ non-inductive resistor. A calibration test was carried out according to IEC 60270, and the sensitivity was 0.25 pC/mV. PD pulses were distributed in the phase of $50^{\circ}{\sim}135^{\circ}$ and over 95% of them existed in the phase of $55^{\circ}{\sim}120^{\circ}$ for the POC. PD pulses were distributed in the phase of $230^{\circ}{\sim}310^{\circ}$ and over 90% of them existed in phase of $220^{\circ}{\sim}300^{\circ}$ for the POE. PD pulses occurred in the phase of $40^{\circ}{\sim}60^{\circ}$ and $220^{\circ}{\sim}300^{\circ}$ for the crack, and pulse counts were 25% higher in negative polarity than in positive polarity. PD pulses were distributed in every phase unlike to other three electrode systems and the peak magnitude was measured at $118^{\circ}$ and $260^{\circ}$ for the FP. As described above, PD pulses were observed in positive polarity for the POC, in negative one for the POE, in both one for the crack and the FP. In conclusion, it is expected that the identification rate of defect type can be improved by considering the polarity ratio of PD pulses on the PRPDA method.

Power-Scalable, Sub-Nanosecond Mode-Locked Erbium-Doped Fiber Laser Based on a Frequency-Shifted-Feedback Ring Cavity Incorporating a Narrow Bandpass Filter

  • Vazquez-Zuniga, Luis Alonso;Jeong, Yoonchan
    • Journal of the Optical Society of Korea
    • /
    • 제17권2호
    • /
    • pp.177-181
    • /
    • 2013
  • We present an all-fiberized power-scalable, sub-nanosecond mode-locked laser based on a frequency-shifted-feedback ring cavity comprised of an erbium-doped fiber, a downshifting acousto-optic modulator (AOM), and a bandpass filter (BPF). With the aid of the frequency-shifted feedback mechanism provided by the AOM and the narrow filter bandwidth of 0.45 nm, we generate self-starting, mode-locked optical pulses with a spectral bandwidth of ~0.098 nm and a pulsewidth of 432 to 536 ps. In particular, the output power is readily scalable with pump power while keeping the temporal shape and spectral bandwidth. This is obtained via the consolidation of bound pulse modes circulating at the fundamental repetition rate of the cavity. In fact, the consolidated pulses form a single-entity envelope of asymmetric Gaussian shape where no discrete internal pulses are perceived. This result highlights that the inclusion of the narrow BPF into the cavity is crucial to achieving the consolidated pulses.

A Study of the Properties of Optically Induced Layers in Semiconductors Aided by the Reflection of Optically Controlled Microwave Pulses

  • Wang, Xue;Choi, Yue-Soon;Park, Jong-Goo;Kim, Yong-K.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권4호
    • /
    • pp.111-115
    • /
    • 2009
  • We present a study on the reflection of optically controlled microwave pulses from non uniform plasma layers in semiconductors. The transient response of the microwave pulses in different plasma layers has been evaluated by means of the reflection function of dielectric microstrip lines. The lines were used with an open-ended termination containing an optically induced plasma region, which was illuminated by a light source. The reflection characteristics impedance resulting from the presence of plasma is evaluated by means of the equivalent transmission line model. We have analyzed the variation of the transient response in a 0.01 cm layer with a surface frequency in the region of 128 GHz. In the reflection the variation of the diffusion length $L_D$ is large compared with the absorption depth $1/{\alpha}_l$. The variation of the characteristic response of the plasma layer with differentially localized pulses has been evaluated analytically. The change of the reflection amplitude has been observed at depths of 0.1 cm, 0.01 cm and $0.1{\times}10^{-5}$ cm respectively.

저주파 플라이백 스위칭회로를 이용한 고성능 자기자극기 (A Magnetic Stimulator Adopting a Low-Frequency Fly-Back Switching Circuit)

  • 이정한;김형식;허문창;김정회
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.343-350
    • /
    • 2006
  • Medical magnetic stimulator generates strong magnetic field pulses. Clinical applications of the magnetic pulse are the stimulation of nervous system and the contraction of muscle. The unique source of the strong magnetic pulse is a capacitor-inductor resonator and this inductor generates a strong sinusoidal magnetic pulse by discharging the capacitor with high initial voltage. Continuous muscle contraction needs sequential generation of the magnetic pulses. However, to keep the magnitude of sequential pulses identical, an expensive high-voltage power supply have to support voltage drop of the capacitor between the pulses. A protection circuit between the supply and the resonator is necessary to protect the supply from reverse current caused by capacitor voltage reversal. In this paper, a new circuit structure of the magnetic stimulator adopting a low-frequency fly-back switching is proposed. The new circuit supports sequential pulse generation and allows the reverse current without damage. Performance of the new circuit is examined and a low-cost magnetic stimulator for urinary incontinence therapy is being developed using the presented method.

비정질 실리콘 방사선 계측기에서의 Photoconductive Gain의 응용 (Utilization of Photoconductive Gain Mechanism in Amorphous Silicon Radiation Detectors)

  • 이형구;서태석;최보영;신경섭;조규성
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.457-460
    • /
    • 1997
  • The photoconductive gain mechanism in various types of hydrogenated amorphous silicon devices, such as p-i-n, n-i-n and n-i-p-i-n structures was investigated in connection with applications to radiation detection. We measured the photoconductive gain in two time scales: one for short pulses of visible light $(<1{\mu}sec)$ which simulate the transit of energetic charged particles, and the other for rather long pulses of light $(\sim1msec)$ which simulate x-ray exposure in medical imaging. We used two definitions of photoconductive gain: current gain and charge gain which is an integration of the current gain. We found typical charge gains of $3\sim9$ for short pulses and a few hundred for long pulses at a dark current density level of $10mA/cm^2$.

  • PDF

모터 구동 장치의 가청 소음 저감을 위한 새로운 3상 Lead-Lag 랜덤 펄스 위치 PWM 기법 (A New Three-Phase Lead-Lag Random Pulse Position PWM Scheme for Decreasing Audible Acoustic Noise of Motor Drives)

  • 위석오;정영국;임영철;나석환
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권7호
    • /
    • pp.387-398
    • /
    • 2002
  • In this paper, a new Three-Phase Lead-Lag Random Pulse Position PWM(LL-RPWM) scheme is proposed and implemented for decreasing audible acoustic noise of motor drives. In the proposed RPWM(Random PWM), each of three phase pulses is located randomly in each switching interval. Based on the space vector modulation technique, the duty ratio of the pulses is calculated. Along with the randomization of the PWM pulses, we can obtain the effects of spread spectra of voltage, current as in the case of randomly changed switching frequency. To verify the validity of the proposed LL-RPWM, the simulation and experimental study was tried. Along with the randomization PWM pulses, the space vector modulation is also executed in the C167 micro-controller. The simulation and experimental results show that the voltage and current harmonics are spread to a wide band area and that the audible acoustic noise is reduced by the proposed RPWM method.