• Title/Summary/Keyword: pulsed mode

Search Result 172, Processing Time 0.03 seconds

Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia (만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.846-855
    • /
    • 1999
  • Background : Secondary pulmonary hypertension is an important final endpoint in patients with chronic hypoxic lung disease, accompanied by deterioration of pulmonary hemodynamics. The clinical diagnosis of pulmonary hypertension and/or cor pulmonale could be difficult, and simple noninvasive evaluation of pulmonary artery pressures has been an relevant clinical challenge for many years. Doppler echocardiography might to be a more reliable method for evaluating pulmonary hemodynamics in such patients in terms of the accuracy, reproducibility and easiness for obtaining an appropriate echocardiographic window than M-mode echocardiography. The aim of this study was to assess echocardiographic parameters associated with pulmonary arterial hypertension, defined by increasing right ventricular systolic pressure(RVSP), calculated from trans-tricuspid gradient in patients with chronic hypoxic lungs. Method : We examined 19 patients with chronic hypoxic lung disease, suspected pulmonary hypertension under the clinical guidelines by two dimensional echocardiography via the left parasternal and subcostal approach in a supine position. Doppler echocardiography measured RVSP from tricuspid regurgitant velocity in continuous wave with 2.5MHz transducer and acceleration time(AT) on right ventricular outflow tract in pulsed wave for the estimation of pulmonary arterial pressure. Results : On echocardiography, moderate to severe degree of pulmonary arterial hypertension was defined as RVSP more than 40mmHg, presenting tricuspid regurgitation. Increased right ventricular endsystolic diameter and shortened AT were noted in the increased RVSP group. Increased RVSP was correlated negatively with the shortening of AT. Other clinical data, including pulmonary functional parameters, arterial blood gas analysis and M mode echocardiographic parameters were not changed significantly with the increased RVSP. Conclusion : These findings suggest that shortened AT on pulsed doppler can be useful when quantifying pulmonary arterial pressure with increased RVSP in patients with chronic lung disease with hypoxemia. Doppler echocardiography in pulmonary hypertension of chronic hypoxic lungs is an useful option, based on noninvasiveness under routine clinical practice.

  • PDF

X-Band 50 W Pulse-Mode GaN HEMT Internally Matched Power Amplifier (X-대역 50 W급 펄스 모드 GaN HEMT 내부 정합 전력 증폭기)

  • Kang, Hyun-Seok;Bae, Kyung-Tae;Lee, Ik-Joon;Cha, Hyen-Won;Min, Byoung-Gue;Kang, Dong-Min;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.10
    • /
    • pp.892-899
    • /
    • 2016
  • In this paper, an X-band 50 W internally matched power amplifier is designed and fabricated using an $80{\times}150{\mu}m$ GaN HEMT that is developed by the $0.25{\mu}m$ GaN HEMT process of ETRI. The optimum source and load impedances are experimentally extracted from the loadpull measurement using impedance-transform-prematching circuits, and the transistor performance is predicted. The power performance of the internally matched power amplifier, whose matching circuits are fabricated on a substrate with ${\varepsilon}_r$ of 10.2, is measured under the pulsed mode of $100{\mu}s$ pulse period and 10 % duty cycle, and the best output power of 47.46 dBm(55.5 W) and the power-added efficiency of 46.6 % are obtained at 9.2 GHz. The output power of 47~47.46 dBm(50~55.7 W) is measured in 9.0~9.5 GHz, and the power-added efficiency is measured to be greater than 43 % in 9.0~9.3 GHz and above 36 % in 9.4~9.5 GHz.

Observation of Molecular Relaxation Behavior of Glucose Powders with Different Structures and Particle Sizes Using Low Field Nuclear Magnetic Resonance (NMR) (NMR을 이용한 구조 및 입도 차이에 따른 분말 포도당의 molecular relaxation behavior의 관찰)

  • Chung, Myung-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.1140-1144
    • /
    • 2002
  • Molecular relaxation behaviors of crystalline glucose anhydrous, crystalline glucose monohydrate, and amorphous glucose with different particle sizes were observed by measuring spin-spin relaxation time constant $(T_2)$ at the temperature range of $-20\;to\;110^{\circ}C$ using temperature-controlled low field nuclear magnetic resonance spectroscopy. No change in $T_2$ values of crystalline glucose anhydrous was observed throughout the temperature range, whereas $T_2$ values of crystalline glucose monohydrate and amorphous glucose increased from around $45\;and\;65^{\circ}C$, respectively. These results indicate that molecular mobility of crystalline glucose anhydrous does not change even at temperature higher than $100^{\circ}C$ and that the stability of powdered glucose could be improved by increasing the particle size of materials.

An Epidemiological Investigation on an Outbreak of Shigellosis in a Special School for Handicapped in Yeongcheon-si and in a Rehabilitation Facility in Gyeongsan-si, Korea, 2008 (2008년 영천시 지적장애인 학교와 경산시 재활원에서 발생한 세균성이질에 관한 역학조사)

  • Lee, Hyun-Dong;Lee, Soon-Ok;Lim, Hyun-Sul
    • Journal of agricultural medicine and community health
    • /
    • v.34 no.1
    • /
    • pp.24-33
    • /
    • 2009
  • Objectives: In September 2008, an outbreak of diarrhea occurred among students attending Y school in Yeongcheon-si. Shigella sonnei was cultured from some of the rectal swabs. An epidemiological investigation was carried out to determine the source of the infection and the mode of transmission of the shigellosis outbreak. Methods: The index case lived in the D rehabilitation facility in Gyeongsan-si and an additional epidemiological investigation was carried out there. The cases could not be questioned due to their mental handicaps. The teachers were interviewed instead. A patient case was defined as a resident with diarrhea more than one time a day from September 18 to September 26, 2008 or a resident with confirmed Shigella sonnei at the Y school or the D rehabilitation facility. Results: The attack rate was 1.2% (8 persons) among 659 persons in the Y school and D rehabilitation facility. Five persons were microbiologically confirmed to have the infection and three persons were diagnosed on the basis of symptoms. Shigella sonnei was cultured from five of the 659 rectal swabs. However, 80 environmental specimens including drinking water, preserved foods, and cooking utensils were negative. All eight patients were Y school students and had been living in group boarding and lodging. Six of them lived in the D rehabilitation facility and two lived in the dormitory at the Y school. Five cases showed pulsed-field gel electrophoresis patterns that were identical for Shigella sonnei. Conclusions: The results of this study showed that the infection source of the shigellosis outbreak, in the two places, were identical. It is likely that the infections initially spread from a teacher or volunteer and then among the students.

Batch and Fed-batch Fermentation for the Lovastatin Production by Cerulenin-resistant Aspergillus terreus Mutant (Cerulenin 저항성 Aspergillus terreus 변이주로부터 lovastatin 생산을 위한 회분식과 유가식 배양)

  • 문미경;전계택;정용섭
    • KSBB Journal
    • /
    • v.16 no.1
    • /
    • pp.87-94
    • /
    • 2001
  • The biosynthesis of Lovastatin, a cholesterol lowering agent formed by the filamentous fungus, cerulenin-resistant Aspergillus terreus mutant was studied in shake flasks and bioreactors. The lovastatin production could be improved by fed-batch under the limited condition of carbon source. The relationship between the fungal morphology and the lovastatin production was also examined during the fed-batch cultures. The fed-batch studies in shake flasks were carried out to find the optimum glucose feeding method, and the pulsed feeding of glucose from 3 days onward at 24 hours intervals was found to be optimal to increase the lovastatin production and reduce the average pellet size. When the pH was controlled at around 5.8 during the whole fermentation period, the lovastatin concentration reached 384 mg/L, which is much higher than the values obtained pH-uncontrolled and pH 7.4. The optimal glucose feeding strategies was found that 30 g/L of glucose was added initially in batch mode, and then fed-batch was conducted by continuous addition of glucose solution(180 g/L) from 72 to 240 hr at a rate of 1.2 mL/hr at $28^{\circ}C$, pH 5.8, 400 rpm, and 1.0 vvm. The lovastatin concentration of 547 mg/L was obtained in 168 hr. It was about 1.5 times higher than the value of the batch fermentation.

  • PDF

High-$T_c$ 2nd-order SQUID Gradiometer for Use in Unshielded Environments (비차폐 환경에서의 고온초전도 SQUID 2차 미분기의 특성연구)

  • 박승문;강찬석;이순걸;유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.50-54
    • /
    • 2003
  • We have fabricated $∂^2$$B_{z}$ /$∂x^2$ type planar gradiometers and studied their properties in operation under various field conditions. $YBa_2$$Cu_3$$O_{7}$ film was deposited on $SrTiO_3$ (100) substrate by a pulsed laser deposition (PLD) system and patterned into a device by the photolithography with ion milling technique. The device consists of 3 pickup loops designed symmetrically Inner dimension and the width of the square side loops are 3.6 mm and 1.2 mm, respectively, and the corresponding dimensions of the center loop are 2.0 mm and 1.13 mm. The length of baseline gradiometer is 5.8 mm. Step-edge junction width is 3.0 $\mu\textrm{m}$ and the hole size of the SQUID loop is 3 $\mu\textrm{m}$ ${\times}$ 52 $\mu\textrm{m}$. The SQUID inductance is estimated to be 35 pH. The device was formed on a 20 mm ${\times}$ 10 mm substrate. We have tested the behavior of the device in various field conditions. The unshielded gradiometer was stable under extremely hostile conditions on a laboratory bench. Noise level 0.45 pT/$\textrm{cm}^2$/(equation omitted)Hz and 0.84 pT/$\textrm{cm}^2$/(equation omitted)Hz at 1 Hz for the shielded and the unshielded cases, which correspond to equivalent field noises of 150 fT/(equation omitted)Hz and 280 fT/(equation omitted)Hz, respectively. In spite of the short baseline of 5.8 mm, the high common-mode-rejection-ratio of the gradiometer, $10^3$, allowed us to successfully record magnetocardiogram of a human subject, which demonstrates the feasibility of the design in biomagnetic studies.

  • PDF

Growth and Structural Properties of Fe Thin Films Electrodeposited on n-Si(111) (n-Si(111) 기판 위에 전기증착에 의한 Fe 박막의 성장과 구조적 특성)

  • Kim Hyun-Deok;Park Kyeong-Won;Lee Jong-Duk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.9
    • /
    • pp.1663-1670
    • /
    • 2006
  • Single crystal Fe thin films were grown directly onto n-Si(111) substrates by pulsed electrodeposition. Cyclic Voltammogram(CV) indicated that the $Fe^{2+}/n-Si(111)$ interface shows a good diode behavior by forming a Schottky barrier. From Mott-Schottky (MS) relation, it is found that the flat-band potential of n-Si(111) substrate and equilibrium redox potential of $Fet^{2+}$ ions are -0.526V and -0.316V, respectively. The nucleation and growth kinetics at the initial reaction stages of Fe/n-Si(111) substraste was studied by current transients. Current transients measurements have indicated that the deposition process starts via instantaneous nucleation and 3D diffusion limited growth. After the more deposition, the deposition flux of Fe ions was saturated with increase of deposition time. from the as-deposited sample obtained using the potential pulse of 1.4V and 300Hz, it is found that Fe nuclei grows to three dimensional(3D) islands with the average size of about 100nm in early deposition stages. As the deposition time increases, the sizes of Fe nuclei increases progressively and by a coalescence of the nuclei, a continuous Fe films grow on the Si surface. In this case, the Fe films show a highly oriented columnar structure and x-ray diffraction patterns reveal that the phase ${\alpha}-Fe$ grows on the n-Si(111) substrates.

Measurement of Distributed Temperature and Strain Using Raman OTDR with a Fiber Line Including Fiber Bragg Grating Sensors (광섬유 브래그 격자 센서가 있는 광섬유 라인에 라만 OTDR을 이용한 분포 온도 및 변형률 측정 가능성에 대한 연구)

  • Kwon, Il-Bum;Byeon, Jong-Hyun;Jeon, Min-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.443-450
    • /
    • 2016
  • In this study, we propose a novel fiber optic sensor to show the measurement feasibility of distributed temperature and strains in a single sensing fiber line. Distributed temperature can be measured using optical time domain reflectometry (OTDR) with a Raman anti-Stokes light in the sensing fiber line. Moreover, the strain can be measured by fiber Bragg gratings (FBGs) in the same sensing fiber line. The anti-Stokes Raman back-scattering lights from both ends of the sensing fiber, which consists of a 4 km single mode optical fiber, are acquired and inserted into a newly formulated equation to calculate the temperature. Furthermore, the center wavelengths from the FBGs in the sensing fiber are detected by an optical spectrum analyzer; these are converted to strain values. The initial wavelengths of the FBGs are selected to avoid a cross-talk with the wavelength of the Raman pulsed pump light. Wavelength shifts from a tension test were found to be 0.1 nm, 0.17 nm, 0.29 nm, and 0.00 nm, with corresponding strain values of $85.76{\mu}{\epsilon}$, $145.55{\mu}{\epsilon}$, $247.86{\mu}{\epsilon}$, and $0.00{\mu}{\epsilon}$, respectively. In addition, a 50 m portion of the sensing fiber from $30^{\circ}C$ to $70^{\circ}C$ at $10^{\circ}C$ intervals was used to measure the distributed temperature. In all tests, the temperature measurement accuracy of the proposed sensor was less than $0.50^{\circ}C$.

Evaluation of cardiac function by tissue Doppler imaging in children with cancer (Tissue Doppler imaging을 이용한 소아 종양 환자에서의 심기능 평가)

  • Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.417-423
    • /
    • 2006
  • Purpose : The objectives of this study were to assess ventricular function by tissue Doppler imaging in children who were receiving chemotherapy or who had received chemotherapy, and to apply repeated tissue Doppler imaging to make an early assessment in cardiac toxicity studies. Methods : This study was conducted on 23 oncology patients on-treatment or off-treatment from April 2005 to July 2005 at Dongsan Medical Center, Keimyung University. All patients(group 1) were divided into two groups, fractional shortening(FS) over 29 percent(group 2) and FS under 28 percent (group 3) in the first category. These same patients were also divided into the following groups : group treated with anthracyclin(group 4) and group treated without anthracyclin(group 5). Deceleration time(DT), isovolumic relaxation time(IVRT), FS, peak early diastolic(E), and peak late diastolic (A) velocity of transmitral flow were measured by M-mode and pulsed wave Doppler. Systolic(Sm), peak early diastolic(Em), and peak late diastolic(Am) velocity in apical 4-chamber and 2-chamber views were measured by tissue Doppler imaging. The author calculated a modified Tei index, E/A, E/Em ratio by using measured values. Results : Twenty three patients were enrolled : 12 boys and 11 girls. The average age of patients was 8 years and 4 months. Thirteen out of 23 patients were in the group treated with anthracyclin (group 4) and 6 had FS under 28 percent(group 3). E/Em ratio showed a significant difference between group 1 and control group($6.46{\pm}1.85$ vs $7.06{\pm}1.64$, P<0.05). Other parameters had no difference statistically. Conclusion : This study showed that the change of cardiac function developed earlier in diastolic function than in systolic function, as E/Em ratio reflecting the mean LV diastolic pressure showed a significant difference between the control group and chemotherapy groups. Echocardiography using tissue Doppler imaging is a non-invasive, comfortable and reliable method for post-chemotherapy follow up.

Quantitative Assessment of Myocardial Tissue Velocity in Normal Children with Doppler Tissue Imaging : Reference Values, Growth and Heart Rate Related Change (소아에서 도플러 조직영상을 이용한 최대 심근 속도의 계측 : 정상 추정치 및 성장 및 심박동수에 따른 변화)

  • Kim, Se Young;Hyun, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.846-856
    • /
    • 2005
  • Purpose : To measure the peak myocardial tissue velocities and patterns of longitudinal motion of atrioventricular(AV) annuli and assess body weight and heart rates-related changes in normal children. Methods : Using pulsed wave Tissue Doppler Imaging(TDI), we measured peak systolic, early and late diastolic myocardial velocities in 72 normal children at six different sites in apical-4 chamber (A4C) view and at four different sites in apical-2 chamber(A2C) view and compared those values with each other, also observing effects with body weights and heart rates. Longitudinal motions of the AV annuli were measured at three different sites in A4C. Results : There were no significant differences of the TDI parameters between gender, ECHO-machines and among the three Doctors performing TDI. Peak myocardial velocities were significantly higher at the base of the heart than in the mid-ventricular region and in the right lateral ventricular wall than in the left lateral ventricular wall or IVS. The TDI parameters showed no significant correlation with fractional shortening(%). Peak systolic and early diastolic myocardial velocities had no correlation with heart rates, but peak late diastolic velocities and A/E ratio correlated positively with heart rates. Correlations between the TDI parameters and body weight were inconsistent. Absolute longitudinal displacement and % displacement were not differ between gender and not correlated with the TDI parameters. Conclusion : We measured the peak myocardial velocities with TDI and the longitudinal motion of the AV annuli using M-mode echocardiography in normal children. With more large scale evaluation, we may establish reference values in normal children and broaden clinical applicabilities in congenital and acquired heart diseases.