• Title/Summary/Keyword: pulse pattern

Search Result 426, Processing Time 0.032 seconds

Study of the Specific Indicators Calculation of Fire-Heat Pattern Identification and Yin Deficiency Pattern Identification in Stroke (중풍 화열 변증과 음허 변증을 구분하는 특정 지표 산출에 대한 연구)

  • Kang, Baek-Gyu;Kang, Byeong-Kab;Lee, Jung-Sup;Han, Deok-Jin;Nam, Sang-Kyu;Shin, Sun-Ho;Moon, Byung-Soon;Lee, In
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.6
    • /
    • pp.1368-1373
    • /
    • 2008
  • This study was done to calculate the specific indicators of Fire-Heat Pattern Identification and Yin Deficiency Pattern Identification settled by tentative Korean Standard Differentiation of the Symptoms and Signs for Stroke. The subjects were 764 hospitalized patients with stroke, and a list of registry was made for each of them. Frequency and Correlations among Fire-Heat and Yin Deficiency indicators were studied. Fire-Heat pattern group included 175 patients out of 764, Yin Deficiency pattern group included 103 patients out of 764. Among the indicators of Fire-Heat pattern, those, in order of highest frequency, were 'heat vexation and aversion to heat', 'reddened complexion', 'thirst'. Among the indicators of Yin Deficiency pattern, those, in order of highest frequency, were 'dry mouth', 'red tongue', 'fine and rapid pulse'. Among the Fire-Heat pattern indicators, 'yellow fur' and 'thirst', 'heat vexation in the chest' and 'vexation and insomnia' showed most significant correlation. Among the Yin Deficiency pattern indicators, 'aphtha or tongue sore' and 'heat in the palms and soles', 'red tongue' and 'dry fur' showed most significant correlation. 'Reddened complexion', 'dry eyes', 'surging and parid pulse', 'heat vexation and aversion to heat' are classify between Fire-Heat pattern and Yin Deficiency pattern. 'Surging and parid pulse', 'Reddened complexion' are mostly representative of Fire-Heat pattern and 'fine and rapid pulse' are mostly representative of Yin Deficiency pattern.

Auxiliary Address Pulse Driving Scheme for Improving Luminance and Luminous Efficiency in 42-inch WVGA Plasma Display Panel

  • Park, Ki-Hyung;Lee, Eun-Cheol;Cho, Ki-Duck;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.329-332
    • /
    • 2003
  • The effects of an auxiliary address pulse driving scheme, in which an auxiliary short pulse was applied to the address electrode during a sustain-period, was examined under the various image patterns of the 42-inch WVGA ac-PDP. When the auxiliary address pulse driving scheme was applied, the luminance of the red, green and blue cells were measured respectively. The luminance, luminous efficiency and current were measured under the full-white pattern of the 42-inch ac-PDP. As a result, the luminance of blue cell was improved approximately by 17 %, whereas the luminous efficiency of the full-white pattern was improved approximately by 34 % without a misfiring discharge in comparison with conventional driving scheme.

  • PDF

Properties and classification of air discharge by Kohonen network (기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

Correlation between Pulse-respiration Ratio and Heart Rate Variability (맥솔(脈率)과 심박변이도(心搏變移度)의 상관성(相關性) 연구(硏究))

  • Yang, Dong-Hoon;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.104-120
    • /
    • 2006
  • Background : Pulse-respiration ratio has been used for estimating subject's status in oriental medicine. Pulse and respiration is strongly associated with autonomic nerve system. But there is no research about correlation between pulse-respiration ratio and autonomic nerve system. Objectives : We performed this study to know correlation between pulse-respiration ratio and HRV(heart rate variability) that shows autonomic nerve system status well and to clarify clinical meaning of pulse-respiration ratio. Methods : After subject's 10 minutes rest, we measured subject's ECG, respiration pattern and HRV. In this research, subject's number is 95(Male 50/Female 45). We calculated pulse-respiration ratio from ECG and respiration pattern. Then, we analyzed correlation between pulse-respiration ratio and HRV parameters in all subjects, 2 group divided by Wan-Maek(P-R ratio 4.28). We tried to compare HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek group. Correlation analysis between pulse-respiration Ratio and Pulse rate, respiration rate is performed. Finally correlation analysis between Respiration and HRV parameters in all subjects, 2 group divided by Wan-Maek(4.28) is studied. Results : 1. Mean pulse-respiration is 4.10${\pm}$0.67, Mean pulse rate is 68.06${\pm}$7.82bpm, Mean respiration rate is 16.81${\pm}$2.72 times per minute in all subjects. 2. Correlation analysis between pulse-respiration ratio and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm(correlation coefficient 0.306, p= 0.018), lnHF (0.308, p=0.002) is significantly correlated with pulse-respiration ratio. 3. Comparison of HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek Group is not significant. 4. Pulse-respiration ratio is more affected by respiration rate(correlation coefficient-0.17, p=0.000) than pulse rate (correlation coefficient 0.396, p=0.000). 5. Correlation analysis between respiration rate and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm (correlation coefficient -0.327, p=0.011), LF/HF(0.346, p=0.007), lnHF (-0.355, p=0.006) are significantly correlated with respiration rate. Conclusion : Pulse-respiration ratio and parasympathetic index has positive correlation. The closer Wan-Maek, The higher parasympathetic index in low pulse-respiration ratio group. Respiration rate is more related with pulse-respiration ratio than pulse rate. Respiration is negatively correlated with autonomic parameters. And the slower respiration, the higher parasympathetic index in low pulse-respiration ratio group.

  • PDF

Analysis of PRI Pattern with the Second Deviation of LASER Pulse Train (레이저 펄스열의 2차 차분을 이용한 PRI 패턴 분석)

  • Lim, Joong-Soo;Hong, Kyung-Ho;Jun, Gab-Song;Moon, Sung-Chul;Lee, Chang-Jae;Suh, Suhk-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.4
    • /
    • pp.63-70
    • /
    • 2008
  • This paper presents a method of PRI do-interleaving for LASER pulse signals. When the PRI of LASER pulse is periodically changed, the first deviation and the second deviation of TOA is used to calculate the PRI pattern of input LASER signals of receiver. If the standard deviation of the first difference of TOA is less than 5% of the average of the first difference of TOA, the PRI pattern of LASER signal is fixed or jittered type. If the standard deviation is larger than 5% of the average, those are triangular PRI patterns or sawtooth PRI patterns.

Design and Implementation of Parabolic Speed Pattern Generation Pulse Motor Control Chip (포물선 가감속 패턴을 가지는 정밀 펄스 모터 콘트롤러 칩의 설계 및 제작)

  • Won, Jong-Baek;Choi, Sung-Hyuk;Kim, Jong-Eun;Park, Jone-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.284-287
    • /
    • 2001
  • In this paper, we designed and implemented a precise pulse motor control chip that generates the parabolic speed pattern. This chip can control step motor[1], DC servo[2] and AC servo motors at high speed and precisely. It can reduce the mechanical vibration to the minimum at the change point of a degree of acceleration. Because the parabolic speed pattern has the continuous acceleration change. In this paper, we present the pulse generation algorithm and the parabolic pattern speed generation. We verify these algorithm using visual C++. We designed this chip with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and executed a logic simulation and synthesis using Synopsys synthesis tool. We executed the pre-layout simulation and post-layout simulation with Verilog-XL simulation tool. This chip was produced with 100 pins, PQFP package by 0.35 um CMOS process and implemented by completely digital logic. We developed the hardware test board and test program using visual C++. We verify the performance of this chip by driving the servo motor and the function by GUI(Graphic User Interface) environment.

  • PDF

Transcranial Magnetic Stimulation using Cockroft-Walton Circuit and Half Bridge Resonant Inverter (코크로프트-월톤회로와 반파공진인버터를 적용한 경두개 자기자극장치)

  • Kim, Whi-Young;HwangBo, Gak
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.4
    • /
    • pp.257-264
    • /
    • 2010
  • Though existent a transcranial magnetic stimulation makes various treatment and diagnostic sine waveform of fixed stimulation pulse, there is limitation. In this research, because strength, pulse width, pulse pattern required in treatment and diagnostic introduce other Cockroft-Walton circuit and half bridge inverter frequency and voltage variable become new device propose wish to. Have more advantages than existing device. First, do not have high voltage transformer. Second, switching loss can be less, and control output energy precisely. Three, stimulation strengths, pulse width, pulse pattern are various. As a result, sought special quality and an experiment that is improved applying inverter and cockroft - Walton circuit is half bridge inverter that do not use transformer.

A Study on Characteristics of Pulse Diagnosis in Infertile Women (여성 불임환자의 맥진특성 연구)

  • Yoo, Jeongeun;Jang, Saebyel;Yoo, Dongyoul
    • Journal of Haehwa Medicine
    • /
    • v.23 no.2
    • /
    • pp.15-21
    • /
    • 2015
  • Objective : The purpose of this study is to demonstrate the characteristics of pulse diagnosis in infertile women. Methods : We have studied 38 women infertility patients in the Dunsan oriental hospital by using pulse diagnostic device. Pulsation and pulse types have been analyzed with variables of infertility factors. Statistical analysis was performed by adopting descriptive and inferential tests. Results : Both right and left chi parts were shown different from other parts. In small intestine and gall bladder showed significantly different pulsation according to the infertility factor. Short pulse, fine pulse, skipping pulse, shallow pulse and deep pulse were often representative pulse types for the main organs of woman infertility. In Triple energizers showed significantly different shallow pulse type according to the infertility factor. Conclusion : The results corresponded closely with previous literature on pulse diagnosis about infertile women.

  • PDF

General Patterns in Echolocation Call of Greater Horseshoe Bat Rhinolophus ferrumequinum, Japanese Pipistrelle Bat Pipistrellus abramus and Large-Footed Bat Myotis macrodactylus in Korea (한국에 서식하는 곤박쥐 Rhinolophus ferrumequinum, 집박쥐 Pipistrellus abramus, 큰발윗수염박쥐 Myotis macrodactylus의 반향정위 형태)

  • Chung, Chul-Un;Han, Sang-Hoon;Lim, Chun-Woo;Kim, Sung-Chul;Lee, Hwa-Jin;Kwon, Yong-Ho;Kim, Chul-Young;Lee, Chong-Il
    • Journal of Environmental Science International
    • /
    • v.19 no.1
    • /
    • pp.61-68
    • /
    • 2010
  • In this study, we analyzed the pulse-duration, pulse-interval and peak-frequency of echolocation call in three species as Rhinolophus ferrumequinum, Pipistrellus abramus, and Myotis macrodactylus. The peak frequency and pulse duration for above mentioned species were 69 kHz, 47 kHz and 49 kHz and $69.39{\pm}8.76\;ms$, $4.95{\pm}0.77\;ms$ and $3.09{\pm}0.48\;ms$ for R. ferrumequinum, P. abramus and M. macrodactylus, respectively. The pulse intervals for R. ferrumequinum, P. abramus and M. macrodactylus were $103.61{\pm}9.05\;ms$, $67.59{\pm}3.47\;ms$ and $66.35{\pm}4.96\;ms$, respectively. The pulse pattern of R. ferrumequinum was setting into a short FM call and linked to long CF call and went through the short FM call again. The pulse pattern of M. macrodactylus was comprised with serial short FM call and the CF call was not checked up in accordance with the spectrogram analysis. The long FM call and short CF call got join together for the P. abramus and the peak frequency was checked up at the pulse ending as CF call.

Effect of Laser Pulse Repetition Rate on the Electrical Properties of $Pb(Zr_{0.48}Ti_{0.52})O_3$ (PZT) Thin Films grown by Pulsed Laser Deposition (펄스 레이저 증착법에 의해 제작된 Laser pulse repetition rate의 변화에 따른 $Pb(Zr_{0.48}Ti_{0.52})O_3$ (PZT) 박막의 전기적 특성)

  • Li, Dong-Hua;Lee, Sang-Yeol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.11-12
    • /
    • 2005
  • [ $Pb(Zr_{0.48}Ti_{0.52})O_3$ ] (PZT) thin films were deposited on Pt(111)/Ti/$SiO_2$/Si substrates by pulsed laser deposition. In order to study the effect of different laser pulse repetition rate on the dielectric and ferroelectric properties of PZT thin films,2 Hz and 5 Hz of laser pulse repetition rate were selected. We compared the results of XRD pattern, dielectric constant and hysteresis characteristics. From the experimental data, we found that the electrical properties of PZT thin films which grown ar 2 Hz of laser pulse repetition rate were better than those which grown at 5 Hz of laser pulse repetition rate.

  • PDF