• 제목/요약/키워드: pulse forming

검색결과 110건 처리시간 0.022초

IGBT 기반 고압 펄스전원장치 (Pulsed Power Modulator based on IGBTs)

  • Ryoo, H.J.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.43-46
    • /
    • 2007
  • In this paper, a novel new pulse power generator based on IGBT stacks is proposed for pulse power application. Proposed scheme consists of series connected 9 power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. The synchronization of gating signal is important for series operation of IGBTs. For gating signal synchronization, full bridge inverter and pulse transformer generates on-off signals of IGBT gating and specially designed gate power circuit was used. Proposed scheme has lots of advantages such as long lifecyle, compact size, flat topped pulse forming, small weight, protection for arc, high efficiency and flexibility to generate various kinds of pulse output.

  • PDF

소형 나노초 입상 고전압 펄스발생장치 (Compact Size Nanosecond Rise Time Hgh Voltage Pulse Generator)

  • 박승록;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1819-1821
    • /
    • 1996
  • A compact size high voltage pulse generator with nanosecond rise time has been fabricated and investigated experimentally. It can be reduced the inductance of the generator by fixing the Marx generator components and pulse forming network components into a single cylindrical unit. As a result, it can be obtained nanosecond rise time about $8{\sim}10[ns]$ and pulse width of several hundred nanoseconds from the modified Marx pulse generator. And parametric studies showed that the rise time of the output pulse was depended little on the change of the load resister and the charging capacitor while the pulse width of the output pulse was depended greatly upon the change of the load resistor and the charging capacitor.

  • PDF

말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료기 (Mini loop coil magnetic curer for peripheral nervous system treatment)

  • 김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.49-51
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse torn and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

PFN을 이용한 펄스발생기의 연구 (A Study on the Pulse Generator using PFN)

  • 이복희;정관모;박종순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1773-1775
    • /
    • 1998
  • This paper deals with the pulse generator using PFN(Pulse Forming Network), and its operation characteristics and application. Two kinds of pulse generator were composed of the best appropriate condition circuit. The output current of the one pulse generator has the rise time of 28 ns and the pulse duration of $7{\mu}s$. The other pulse generator has high current of about 2kA. By use of the former generator with rapid rise time, the impulse impedance characteristic of ground electrodes was investigated with measuring the ground potential rise when the pulse current was injected into the ground electrode.

  • PDF

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

신경계 치료를 위한 루프 프로브형 자기자극기의 시뮬레이터 (The simulator loop probe style magnetic stimulation design for a nervous system treatment)

  • 김휘영
    • 디지털산업정보학회논문지
    • /
    • 제5권3호
    • /
    • pp.29-37
    • /
    • 2009
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Simulator and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of loop object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment digital forming etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Neuralgia, muscular disease and Altzheimer, with stroke etc. is becoming the matter of concern and interest which disease of adult etc. it is same is important. And the melancholia in compliance with the modern direction of a ceremony which is complicated and garrulous, trillion it will cry and symptoms, it is a tendency where the emotional obstacle etc. nervous psychiatric disorder patient is increasing at class speed. But currently the applicator it will be able to treat like this disease almost it is a condition which is wholly lacking. Consequently like this disease it used magnetic stimulation and it diagnosed and the equipment it will be able to treat plan and it embodied.

고전압 나노초 펄스 발생기를 이용한 전자기파 방사 (Impulse Electromagnetic Radition for High Voltage Nanoseconds Pulse Generator)

  • 김영배;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.207-209
    • /
    • 2005
  • Ultra wide band electromagnetic energy can be transmitted to a far field by emitting the nanoseconds high voltage pulse electromagnetic energy via an antenna. This UWB EM energy is expected to be used in post-packing pasteurization of food, detection of buried objects or underground water veins and caves and the treatment of waste water or polluted gas. The nanoseconds pulse forming for UWB generation using high voltage blumlein line and an ultrafast switch is mentioned.

  • PDF

GW급 UWB용 고전압 나노초 펄스 발생 (High Voltage Nanoseconds Pulse Generation for 1GW UWB radiation)

  • 김영배;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2123-2125
    • /
    • 2005
  • Ultra wide band electromagnetic energy can be transmitted to a far field by emitting the nanoseconds high voltage Pulse electromagnetic energy via an antenna. This UWB EM energy is expected to be used in post-packing pasteurization of food, detection of buried objects or underground water veins and caves and the treatment of waste water or polluted gas. The nanoseconds pulse forming for UWB generation using 500kV blumlein line and an ultrafast switch is mentioned.

  • PDF

말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료시스템의 설계 및 제작 (Design and manufacture of mini loop coil magnetic curer for peripheral nervous system treatment)

  • 김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.153-155
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong.) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

Thyratron을 이용한 고압펄스 발생장치 (High voltage pulse power supply using thyratron)

  • 김태진;김성철;김은수;백주원;;이홍식;전성즙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2127-2129
    • /
    • 1998
  • In this paper, discharging part of high voltage pulse power supply of E-beam generating device is simulated and experimented. It is composed of high voltage part and high voltage pulse part. High voltage part is AC 380, DC/DC converter, high voltage high frequency transformer. High voltage pulse part is double pulse forming network and Thyratron. In the result, computer simulation analysis is same to experimental result and high voltage pulse is obtained 10kV, 4A, 10uS.

  • PDF