• Title/Summary/Keyword: pulse disturbance

Search Result 62, Processing Time 0.027 seconds

Fast Compensator of Periodic Disturbance in Disk Drives (디스크 드라이브의 주기적 외란 고속 보상 제어)

  • 부찬혁;김호찬;강창익
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.2
    • /
    • pp.153-163
    • /
    • 2004
  • The control objective in hard disk drives is to move head as fast as possible to target track and position the head over the center of target track in the presence of external disturbances. The external shock or disk clamping error in manufacturing process causes the disk center to deviate from the disk rotation center. The disk shift acts on the control system as disturbance and degrades severely the performance of disk drives. In this paper, we present a new controller that compensates for the periodic disturbances very fast. The disturbance compensator is arranged in parallel with the state feedback controller. To avoid the interference with the state feedback controller, the compensator creates compensation signal without the feedback of system output until steady state. The pulse type controller is included additionally for improving the transient performance due to initial state. Finally, in order to demonstrate the superior performance of the proposed compensator. we present some experimental results using a commercially available disk drive.

Stability Analysis of Nonlinear Pulse-Modulated System Subject to Gaussian Noise (가우스 잡음을 고려한 비선형 펄스 변조 시스템의 안정도 분석)

  • 강영채
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.6
    • /
    • pp.67-79
    • /
    • 1982
  • The stability of general pulse-width modulation system with Gaussian random disturbance was discussed . General system is divided into nonlinear and linear elements using the conventional describing function method. The concept of the equivalent admittance was used to find the transfer characteristic of the nonlinear element of the system. In this paper the self-sustained oscillation condition in the autonomous system was derived and the results was analyzed with computer simulation.

  • PDF

Design of Pulse Amplitude Modulation Controller for the Attitude Control of the Payload of a Sounding Rocket (과학로켓 탑재부 자세제어를 위한 펄스 진폭 변조 제어기 설계)

  • Gong, Hyeon-Cheol;Jeon, Sang-Woon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.11
    • /
    • pp.981-986
    • /
    • 2000
  • A pulse amplitude modulation(PAM) controller is designed for the 3 axis attitude control of a sounding rocket. a certain number of fixed level of thrust are used for the pulse amplitude modulation and the nonlinearity of the controller is considered to examine the existence of the limit cycles and the stability analysis is carried out with the aid of Nyquist plot.

  • PDF

A Investigation into Arrhythmia between East and West medicine (부정맥(不整脈)에 대(對)한 동서의학적(東西醫學的) 문헌고찰(文獻考察))

  • Jeong, Gwang-Sik;Kim, Young-Guen;Kwon, Jung-Nam;Kim, Kyoung-Min
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.5
    • /
    • pp.747-763
    • /
    • 2000
  • through a literal study upon Arrhythmia between east and west medicine, the results were as follows 1. Arrhythmia is not only irregular cardiac beat but disorder of cardiac impulse making and conduction disturbance. it means almost irregularity of interval between two beat 2. In the east medicine, arrhythmia is represented various category as palpitation, continuous palpitation, dizziness, consumption which give the first consideration by the accompanied symptoms. A separate way in a diagnostics it become a base of diagnosis of diseases and decision of prognosis by the examination of pulse 3. In the west medicine, Arrhythmia is classified as disorder of heart rate, rhythm, conduction disturbance or tachycardia, bradycardia and it is concomitant with fatigue, palpitation, dyspnoea, syncope, chest discomfort 4. The diagnostic study of pulse condition which represent arrhythmia was started from $\mathbb{<}$Nae-Kyung$\mathbb{>}$ and it was revealed as pulse condition of rapid pulse, slow pulse, swift pulse, running pulse, knotted pulse, intermittent pulse etc. Out of them running pulse, knotted pulse, intermittent pulse which obviously are concomitant with irregularity of interval are clinically meaningful in a conditions of disease and decision of prognosis. and the significance of these pulse condition are transformed through the changes of the times 5. According to cause of disease it is classified by Arrhythmia(running pulse, knotted pulse, intermittent pulse) due to heat, cold, phlegm, deficiency(or insufficiency) and There are three categories of etiological factor that is, endogenous, exogenous and non-exo-endogenous factor. the endogenous factor is insufficiency of the heart Ki, deficiency of both Ki and blood, intemal stagnation of phlegm and fluid, stagnation of seven emotions. the exogenous factor is caused by stagnation of Ki and blood by six exogenous pathogenic factor and the non-exo-endgenous factors are improper diet, overstrain, traumatic injury. A cause of arrhythmia in western medicine are a organic and pathological change of the heart itself and malfunction of the autonomic nervous system.

  • PDF

Active Disturbance Rejection Control for Single-Phase PWM Rectifier with Current Decoupling Control

  • Yan, Ruitao;Wang, Ping
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2354-2363
    • /
    • 2018
  • This paper proposed a novel double closed control strategy for single-phase voltage source pulse width modulation (PWM) rectifier based on active disturbance rejection control (ADRC) and dq current decoupling control. First, the mathematical model of the single-phase PWM rectifier in the d-q axis synchronous rotating reference frame is established by constructing a virtual component using a second-order generalized integrator (SOGI). Then, the mathematical model is simplified according to the active power conservation, and the first-order equation of single-phase PWM rectifier voltage outer loop is acquired. A linear auto-disturbance rejection controller is used to design the voltage outer loop according to the first-order equation. Finally, the proposed control strategy and the traditional PI control are compared and verified by simulation and physical experiments. Both simulation and experimental results confirm that the proposed control strategy has excellent dynamic performance and strong rejection ability to disturbances.

Vibration Characteristic Analysis of Bridge Simulator by Pulse ESPI System (Pulse ESPI System을 이용한 모형교량의 진동특성해석)

  • Choi JK;Kim K.S.;Jang H.S.;Kang M.G.;Kim S.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1433-1437
    • /
    • 2005
  • Until now, strain gage technique and accelerometer for the diagnosis safety of constructions are used widely. However, the limits of these methods are revealed. But Electronic Speckle Pattern Interferometry(ESPI) that uses Pulse Laser is noncontact, whole-field, real-time measuring method also dull to disturbance and can achieve test result in a very short time. It has various strong point in spot application, swift establishment, and dynamic conduct analysis for the entire field of Laser illuminate. This author analyzed vibration characteristic of using the Pulse ESPI System, the diagnosis safety of bridges, to simplify the analysis of the dynamic conduct of a large construction.

  • PDF

Development of stimulator for peripheral disturbance therapy using A variable Micro-electromagnetic (미약 전자기장을 이용한 말초장애 치료시스템 개발)

  • Kim, Soo-Byung;Lee, Seung-Wook;Shim, Ta-Kyu;Lee, Na-Ra;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1209-1216
    • /
    • 2010
  • It has increased that peripheral disturbance(blood flow, nerve, Raynaud's phenomenon) and finger rheumatoid arthritis which is caused by the diabetic complications. To improve these pain issues, we proposed new method for the Finger Disease Therapy(FDT). In this paper, we manufactured solenoid cylindrical coil which was only for the FDT using a variable micro-electromagnetic. Also, we designed the Finger Disease Therapy System(FDTS) which could select three stimulation modes(N_pulse, S_pulse, N/S_pulse) and frequency(0.25hz, 0.5hz, 1hz). We used a Teslameter to measure magnetic flux inner solenoid, and measured magnetic flux as distance(0 ~ 3cm) inner solenoid with stimulation modes and frequency. In the results, magnetic flux was the highest in center of solenoid(0cm) for all stimulation modes. Also, the highest magnetic flux was measured as N_pulse(294.3mT), S_pulse(293.8mT) in 1Hz and N/S_pulse (275.4mT) in 0.25Hz, respectively. Therefore, we developed the FDTS using various pattern and intensity for finger diseases therapy, and checked therapy clinic application possibility of the FDTS as measuring magnetic flux inner solenoid.

Analysis of PCI Cable Effects in HEMP Conducted Disturbance (HEMP 전도성 방해 펄스 전류 주입(PCI) 케이블의 영향 분석)

  • Jang, Tae-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.772-780
    • /
    • 2013
  • The high-altitude electromagnetic pulse(HEMP) conducted environment and the HEMP radiated environment are established as the consequences of a high-altitude nuclear explosion. The IEC 61000-2-10, the international standard, defines the HEMP conducted environment. The IEC 61000-5-5 defines how protective devices for conducted disturbance proposed for HEMP protection shall be specified. The IEC 61000-4-24 deals with methods for testing protective devices for HEMP conducted disturbance. The IEC 61000-4-24:1997 mainly describes the measurement method of small protective components. However, it does not provide the measurement method for a combination filter of a protective component and a filter which is widely used in recent. It is important to consider the characteristic of the measurement setup parameters like thickness and length of the cable and its height above ground plane etc. in establishing measurement setup because HEMP conducted disturbances include the frequency spectrum below 50 MHz. This paper deals with the optimized measurement method, considering the frequency spectrum of HEMP conducted disturbance, current waveform, and analyzing the effects of cables existing in the measurement setup.

An SCR Thyristor Based Three-Phase Voltage Disturbance Generator

  • Han, Heung-Soo;Jung, Jae-Hun;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.372-378
    • /
    • 2012
  • This paper deals with a 3-phase voltage disturbance generator for a performance test of custom power devices such as dynamic voltage restorers (DVR), dynamic uninterruptable power supplies (UPS), etc. The operating principle of the proposed circuit is described in each mode of voltage sag, swell, outage, and unbalance. The main components of the proposed disturbance generator are silicone controlled rectifier (SCR) thyristors, variable autotransformers, and transformers. Therefore, the disturbance generator can be implemented with a considerably low cost compared to the conventional pulse width modified (PWM) inverter and converter type generators. Furthermore, it has good features of high reliability with simple structure, high efficiency caused by no PWM switching of the SCR thyristors, and easy control with a wide variation range. To verify the validity of the proposed scheme, simulations and experiments are carried out.

Robust Decoupling Digital Control of Three-Phase Inverter for UPS (3상 UPS용 인버터의 강인한 비간섭 디지털제어)

  • Park, Jee-Ho;Heo, Tae-Won;Shin, Dong-Ryul;Roh, Tae-Kyun;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.4
    • /
    • pp.246-255
    • /
    • 2000
  • This paper deals with a novel full digital control method of the three-phase PWM inverter for UPS. The voltage and current of output filter capacitor as state variables are the feedback control input. In addition, a double deadbeat control consisting of a d-q current minor loop and a d-q voltage major loop, both with precise decoupling, have been developed. The switching pulse width modulation based on SVM is adopted so that the capacitor current should be exactly equal to its reference current. In order to compensate the calculation time delay, the predictive control is achieved by the current·voltage observer. The load prediction is used to compensate the load disturbance by disturbance observer with deadbeat response. The experimental results show that the proposed system offers an output voltage with THD less than 2% at a full nonlinear load.

  • PDF