• Title/Summary/Keyword: pulse corona

Search Result 108, Processing Time 0.033 seconds

Properties and Classification of Patterns of Air Discharges (기중방전의 방전원별 특성분석 및 패턴분류)

  • Park, Yeong-Guk;Lee, Gwang-U;Jang, Dong-Uk;Gang, Seong-Hwa;Jeong, Gwang-Ho;Kim, Wan-Su;Lee, Yong-Hui;Im, Gi-Jo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.19-23
    • /
    • 2000
  • Partial discharges(PD)in air insulated electric power apparatus often lead to deterioration of solid insulation by electron bombardments and electrochemical reaction. The PD caused to reduce the life time of power apparatus and to increase power losses. Thus understanding and classification of PD patterns in air are very important to discern sources of PD. In this paper, PD in air by using statistical methods was investigated. We classified air discharges, corona, surface discharges and cavity discharges by Kohonen network. For classification of PD patterns, we used statistical operators and parameters such as skewness$(S^+,\; S^-),\; kurtosis(K^+, K^-),\; mean phase(AP^+, AP^-)$, cross-correlation factor(CC) and asymmetry derived from the mean pulse-height phase distribution$(H_{avg}(\phi))$, the max pulse-height phase distribution $(H_{qmax}(\phi))$, the pulse count phase distribution $(H_n(\phi))$ and the pulse height vs. Repetition rate $(H_q(n))$.

  • PDF

A Comparative Study on the Electrostatic Eliminator of Piezo Type Ionizer and Pulse AC Corona Type Ionizer (피에조를 이용한 코로나 방전과 펄스교류 코로나 방전을 이용한 정전기 제거장치의 비교 연구)

  • Kwon, Sung-Yul;Lee, Dong-Hoon;Choi, Jae-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.50-54
    • /
    • 2009
  • Ionizer is used for improving manufacturing process and reducing inferior goods in the clean room. As a general rule, neutralization of the electrostatic charge is most important to make TFT-LCD, PDP and OLED. Pulse AC-static eliminator with output voltage of about 10.5kV has been used these days as neutralization device. But this device has a problem with lower performance which was caused by particles-adhesion on the electrode when it has been used for a long time. So we studied to solve the problem with lower performance using high Frequency(72kHz) static eliminator which was produced by Piezo transformer device, and compared Pulse-AC type with Piezo-electronic device such as decay time and ion balance for 10 weeks periods. As a result of this study, we found that Piezo transformer device has been maintained normal condition for 10 weeks. Also, we made the rule by this study, normally Piezo transformer device has to clean the electrode during every 11th weeks.

Properties and classification of air discharge by Kohonen network (기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

A Study on the New Partial Discharge Pattern Analysis System used by PA Map (Pulse Analysis Map) (PA Map(Pulse Analysis Map)을 이용한 새로운 부분방전 패턴인식에 관한 연구)

  • Kim, Ji-Hong;Kim, Jeung-Tae;Kim, Jin-Gi;Koo, Ja-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1092-1098
    • /
    • 2007
  • Since one decade, the detection of HFPD (High frequency Partial Discharge) has been proposed as one of the effective method for the diagnosis of the power component under service in power grids. As a tool for HFPD detection, Metal Foil sensor based on the embedded technology has been commercialized for mainly power cable due to its advantages. Recently, for the on-site noise discrimination, several PA (Pulse analysis) methods have been reported and the related software, such as Neural Network and Fuzzy, have been proposed to separate the PD (Partial Discharge) signals from the noises since their wave shapes are completely different from each other. On the other hand, the relevant fundamental investigation has not yet clearly made while it is reported that the effectiveness of the current methods based on PA is dependant on the types of sensors. Moreover, regarding the identification of the vital defects introducible into the Power Cable, the direct identification of the nature of defects from the PD signals through Metal Foil coupler has not yet been realized. As a trial for solving above shortcomings, different types of software have been proposed and employed without any convincing probability of identification. In this regards, our novel algorithm 'PA Map' based on the pulse analysis is suggested to identify directly the defects inside the power cable from the HFPD signals which is output of the HFCT and metal foil sensors. This method enables to discriminate the noise and then to make the data analysis related to the PD signals. For the purpose, the HFPD detection and PA (Pulse Analysis) system have been developed and then the effect of noise discrimination has been investigated by use of the artificial defects using real scale mockup. Throughout these works, our system is proved to be capable of separating the small void discharges among the very large noises such as big air corona and ground floating discharges at the on-site as well as of identifying the concerned defects.

Air/Quartz Dielectric Double Barrier Pulse Discharge (공기/석영관(空氣/石英管) 복합유전체(複合誘電體)장벽층(障壁層)의 고주파(高周波) 펄스 방전(放電) 특성(特性))

  • Lee, Eung-Gwan;Woo, Jung-Uk;Chung, Suk-Hwan;Lee, Dong-Hoon;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1556-1558
    • /
    • 1994
  • An air/quartz dielectric double barrier pulse discharge has been investigated to develop a novel si lent type ozone generator. It is found that there are very active pulsed coronas occurred in the airgap which are very useful for ozone generation. And, the corona onset voltage of the airgap of the air/quartz double barrier was enfluenced greatly by the airgap of the air/quartz dielectric double barrier, and depended greatly upon the airgap ranged of $0.0{\sim}3.0mm$ and by the quartz tube thickness ranged of $1.75{\sim}2.25mm$.

  • PDF

A Study on Discharge Characteristics in Flowing Gas at High Voltage Nozzle (고전압(高電壓) Nozzle 에서 유출(流出)하는 기체(氣體)의 방전특성(放電特性)에 관한 연구(硏究))

  • Song, Hyun-Jig;Kim, Sang-Ku;Jeun, Young-Ju;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.563-565
    • /
    • 1993
  • This paper describes ozone concentration and discharge characteristics in flowing $O_2$ with variation of Re at high voltage nozzle(HVN). HVN type ozonizer is equipped with ten nozzle. The important conclusions obtained from this paper are as follows. For constant pulse width(Pw) and pulse frequency(Pf) the more Re increases, the higher corona onset voltage(Vc) rise. Vc is inversely proportional to Pw and Pf. Ozone concentration($O_{3con}$) increases with less Re for constant Pw and Pf. $O_{3con}$ increases with less Pw. $O_{3con}$ is proportional to Pf.

  • PDF

Non-thermal Plasma Process for simultaneous removal of SO2/NOx from a Sintering Plant of Steel Works

  • Nam, Chang-Mo;Mok, Young-Sun;Kwon, Gi-Hong;Suh, You-Duck;Cho, Byeung-Rak
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.1
    • /
    • pp.81-86
    • /
    • 2003
  • For the simultaneous removal of $SO_2$/NOx from an iron-ore sintering plant, industrial plasma experiments have been conducted with a flue gas flow rate of $5,000Nm^3/hr$. The maximum 40kW power using the magnetic pulse compression (MPC) system generates a peak value of 100-150kV pulse voltage with its risetime of 200nsec and full width at half maximum (FWHM) of 500nsec, and with a frequency <300Hz. The plasma reactor module adopts a wire-plate structure with a gap of 200-400mm ID between plates. Initial concentrations of $SO_2$ and NOx were around 100-150ppm, respectively in the presence of 15% $O_2$ and <10% $H_2O$. Various reaction parameters such as specific energy ($Whr/Nm^3$), $NH_3$ injection with corona discharge, flow rate and injection of hydrocarbons were investigated for $SO_2$/NOx removal characteristics. About 90/65% of $SO_2$/NOx were simultaneously removed with a specific energy of $3.0Whr/Nm^3$ when both $NH_3$ and hydrocarbons were injected. Practical implications that the pilot-scale plasma results provide are further discussed.

  • PDF

Efficient Desulfurization and Denitrification by Low Temperature Plasma Process (저온 플라즈마 공정에 의한 효율적인 탈황 및 탈질)

  • Kim, Sung-Min;Kim, Dong-Joo;Kim, Kyo-Seon
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.129-135
    • /
    • 2005
  • In this study, we have analyzed the removal efficiencies of $SO_2$ and $SO_2/NO$ by the pulsed corona discharge process and investigated the effects of several process variables on those removal efficiencies systematically. The effects of process variables such as applied voltage, pulse frequency, residence time, and initial concentrations of reactants (NO, $SO_2$, $NH_3$, $H_2O$, and $O_2$) on the removal efficiency were analyzed. As the applied voltage, the pulse frequency or the residence time increases or as the $O_2$ or the $H_2O$ or the $NH_3$ concentration in the inlet feed gas stream increases, the $SO_2$ removal efficiencies and the simultaneous removal efficiencies of $SO_2/NO$ also increase. These experimental results can be used as a basis to design the pulsed corona discharge process to remove $NO_x$ and $SO_x$.

Corona Discharge and Strong Electrolyzed Water Generation Characteristics of the Electrode System Bedded by Dielectric Pellets (유전체구 충진형 전극계의 코로나방전과 강전해수 발생특성)

  • 김진규
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.46-54
    • /
    • 2002
  • A dielectric pellets bedded parallel plates with a membrane centered have been proposed as an ion separation and collection system in water. and effects of the relative dielectric constant and the applied square wave pulse voltage on the characteristics of ion separation and collection in tap water and NaCl dissolved tap water have been investigated. As a result, electrolyzed water of pH 3.1 and 10.6 were obtained with only tap water at the pulse current of 1.0[A] and flow rate of 0.5[LPM]. And the higher ionized water of pH 2.8 and pH 11.7 ware obtained in 0.1[%wt] NaCl dissolved water. When the dielectric pellets of BaTiO$_3$ having the highest dielectric constant were bedded in the ion separation and collection cell, the ionized water of pH 2.7 and pH 11.7 were obtained with only tap water. And the ionized water of pH 2.4 and pH 12.0 were obtained in 0.1[wt%] NaCl dissolved tap water with the dielectrics pellets bedded ones.