Air/Quartz Dielectric Double Barrier Pulse Discharge

공기/석영관(空氣/石英管) 복합유전체(複合誘電體)장벽층(障壁層)의 고주파(高周波) 펄스 방전(放電) 특성(特性)

  • 이응관 (경북대학교 전기공학과) ;
  • 우정욱 (한국전력 기술연구원) ;
  • 정석환 (경북대학교 전기공학과) ;
  • 이동훈 (부산공업대학 산업안전공학과) ;
  • 문재덕 (경북대학교 전기공학과)
  • Published : 1994.07.21

Abstract

An air/quartz dielectric double barrier pulse discharge has been investigated to develop a novel si lent type ozone generator. It is found that there are very active pulsed coronas occurred in the airgap which are very useful for ozone generation. And, the corona onset voltage of the airgap of the air/quartz double barrier was enfluenced greatly by the airgap of the air/quartz dielectric double barrier, and depended greatly upon the airgap ranged of $0.0{\sim}3.0mm$ and by the quartz tube thickness ranged of $1.75{\sim}2.25mm$.

Keywords