• Title/Summary/Keyword: pseudo-force

Search Result 117, Processing Time 0.023 seconds

Atomic Force Microscopy Study on Correlation between Electrical Transport and Nanomechanical properties of Graphene Layer

  • Kwon, Sang-Ku;Choi, Sung-Hyun;Chung, H.J.;Seo, S.;Park, Jeong-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.85-85
    • /
    • 2010
  • Graphene, the building block of graphite, is one of the most promising materials due to their fascinating electronic transport properties. The pseudo-two-dimensional sp2 bonding in graphene layers yields one of the most effective solid lubricants. In this poster, we present the correlation between electrical and nanomechanical properties of graphene layer grown on Cu/Ni substrate with CVD (Chemical Vapor Deposition) method. The electrical (current and conductance) and nanomechanical (adhesion and friction) properties have been investigated by the combined apparatus of friction force microscopy/conductive probe atomic force microscopy (AFM). The experiment was carried out in a RHK AFM operating in ultrahigh vacuum using cantilevers with a conductive TiN coating. The current was measured as a function of the applied load between the AFM tip and the graphene layer. The contact area has been obtained with the continuum mechanical models. We will discuss the influence of mechanical deformation on the electrical transport mechanism on graphene layers.

  • PDF

Laboratory Experiments for the Force and Load with Pseudo-Dynamic Test: Ex-vivo Study for the Manual Therapy

  • Choi, Wansuk;Choi, Taeseok;Heo, Seoyoon;Lee, Wooram
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.4
    • /
    • pp.1889-1896
    • /
    • 2019
  • Background: Because of the lack of accurate values for applied forces in manual therapy, manual therapists relies on the magnitude of the individual's perception during applying the force. However, excessive loading maneuvers carry risks for patients. Objective: To establish the relationship between the maximal force applied to swine skin with the specific region, sex, and baseline parameters of the subject. Design: Ex-vivo Study and laboratory Experimental research Methods: 3.5 kg of Korean pork sirloin that is a piece of swine was handled and it was set 3 dimensions; #A; #B; #C. Forty-seven participants who has no experience in physical therapy randomly carried out the experiment, indicated to push each place of the pressure spots with same posture and process under supervision from the instructor who has over 15 years of manual therapy, and we measured the pressure force in each time. Results: The biggest pressure force was recorded in spot #A, and #B was represented after #C. Pressure on #A showed certain statistic relation with height (r=.317, p<.05) and weight (r=.434, p<.01); pressure on #B showed certain relation which has statistical meaning with only height (r=.401, p<.01); pressure on #C emerged to have statistic relationship with height (r=.308, p<.05)and weight (r=.428, p<.01). The age aspect revealed relation with pressure on #A, #B and #C, but that was not statistically significant. Conclusions: It can be inferred that there is the most loss of pressure in the area where cartilage is like an island in the middle.

Displacement-Load Method for Semi-Analytical Design Sensitivity Analysis (준해석 설계민감도를 위한 변위하중법)

  • Yoo Jung Hun;Kim Heung Seok;Lee Tae Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.10
    • /
    • pp.1590-1597
    • /
    • 2004
  • Three methods of design sensitivity analysis for structures such as numerical method, analytical method and semi-analytical method have been developed for the last three decades. Although analytical design sensitivity analysis can provide very exact result, it is difficult to implement into practical design problems. Therefore, numerical method such as finite difference method is widely used to simply obtain the design sensitivity in most cases. The numerical differentiation is sufficiently accurate and reliable fur most linear problems. However, it turns out that the numerical differentiation is inefficient and inaccurate in nonlinear design sensitivity analysis because its computational cost depends on the number of design variables and large numerical errors can be included. Thus the semi-analytical method is more suitable for complicated design problems. Moreover, semi-analytical method is easy to be performed in design procedure, which can be coupled with an analysis solver such as commercial finite element package. In this paper, implementation procedure fur the semi-analytical design sensitivity analysis outside of the commercial finite element package is studied and the computational technique is proposed for evaluating the partial differentiation of internal nodal force, so called pseudo-load. Numerical examples coupled with commercial finite element package are shown to verify usefulness of proposed semi-analytical sensitivity analysis procedure and computational technique for pseudo-load.

Seismic tests of RC shear walls confined with high-strength rectangular spiral reinforcement

  • Zhao, Huajing;Li, Qingning;Song, Can;Jiang, Haotian;Zhao, Jun
    • Steel and Composite Structures
    • /
    • v.24 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • In order to improve the deformation capacity of the high-strength concrete shear wall, five high-strength concrete shear wall specimens confined with high-strength rectangular spiral reinforcement (HRSR) possessing different parameters, were designed in this paper. One specimen was only adopted high-strength rectangular spiral hoops in embedded columns, the rest of the four specimens were used high-strength rectangular spiral hoops in embedded columns, and high-strength spiral horizontal distribution reinforcement were used in the wall body. Pseudo-static test were carried out on high-strength concrete shear wall specimens confined with HRSR, to study the influence of the factors of longitudinal reinforcement ratio, hoop reinforcement form and the spiral stirrups outer the wall on the failure modes, failure mechanism, ductility, hysteresis characteristics, stiffness degradation and energy dissipation capacity of the shear wall. Results showed that using HRSR as hoops and transverse reinforcements could restrain concrete, slow load carrying capacity degeneration, improve the load carrying capacity and ductility of shear walls; under the vertical force, seismic performance of the RC shear wall with high axial compression ratio can be significantly improved through plastic hinge area or the whole body of the shear wall equipped with outer HRSR.

A Study on the Hydraulic Excitation Forces Using Transfer Function and Operational Measured Data for the Centrifugal Pump (전달함수와 진동응답 측정에 의한 원심펌프에서의 유체력 특성에 관한 연구)

  • Choi, Bok-Lok;Park, Jin-Moo;Kim, Kwang-Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.8 s.179
    • /
    • pp.1931-1939
    • /
    • 2000
  • Operating excitation forces of the linear vibratory system are normally determined by direct measurement techniques using load cells, strain gauges, etc. But, hydraulic forces of the rotating turbomachinery such as centrifugal pumps are exerted on an impeller due to asymmety of the flow by the interaction between pump impeller and volute. So, investigations of wide range of hydraulic designs and geometric deviations are difficult by direct method. This paper presents a hybrid approach for fourier transformed operational excitation forces, which uses pseudo-inverse matrix of the transfer matrix for the system and the measured vibrational data with standard installed pump. The determination of the transfer function matrix is based on a linear rotor/stationary system and steady state harmonic response in finite element analysis. And, vibrational data is collected in both vertical and horizontal directions at inboard and outboard bearing housings. The results of the process may be enhanced by making acceleration measurements at many more locations than there are forces to be determined.

Performance Improvement of Integrated Chassis Control with Determination of Rear Wheel Steering Angle (후륜 조향각 결정을 통한 통합 섀시 제어기의 성능 향상)

  • Yim, Seongjin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.2
    • /
    • pp.111-119
    • /
    • 2017
  • This paper presents a method to determine the rear steering angle in integrated chassis control with electronic stability control (ESC) and rear wheel steering (RWS). A control yaw moment needed to stabilize a vehicle should be distributed into the tire forces generated by the ESC and RWS. Weighted pseudo-inverse control allocation (WPCA) is adopted to determine the tire forces. Four methods are proposed to calculate the rear wheel steering angle. To validate the proposed methods, a simulation is performed using a vehicle simulation software package, CarSim. The simulation results show that the proposed method for determining the rear wheel steering angle improves the performance of the integrated chassis control.

Acoustic and Electrical Analysis of Microspeaker for Mobile Phones (모바일 폰용 마이크로스피커의 음향 및 전기 해석)

  • Park, Seok-Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.525-536
    • /
    • 2014
  • In this paper, GUI program for microspeaker system simulation program was developed and verified through closed box, vent box and 6th order bandpass enclosure system. By using the pseudo loudspeaker model concept, TS parameters and rear volume of microspeaker were identified. Their suitabilities were proved by comparing test results with simulations of electrical impedance and sound pressure response curves for the three box types; closed box, vent box and 6th order bandpass box. Also, MSSP was found to be effective regardless of the microspeaker's shape, either circular or rectangular shape. MSSP can be used for the microspeaker system simulation, and can give a general prediction of such as; sound pressure level curve, electrical impedance, diaphragm velocity and displacement curve according to multiple design parameters; diaphragm mass, compliance, force factor, front and rear volume, front and rear port's diameter and length.

Seismic response of vertical shafts in multi-layered soil using dynamic and pseudo-static analyses

  • Kim, Yongmin;Lim, Hyunsung;Jeong, Sangseom
    • Geomechanics and Engineering
    • /
    • v.21 no.3
    • /
    • pp.269-277
    • /
    • 2020
  • In this study, numerical analyses were conducted to investigate the load transfer mechanisms and dynamic responses between the vertical shaft and the surrounding soil using a dynamic analysis method and a pseudo-static method (called response displacement method, RDM). Numerical solutions were verified against data from the literature. A series of parametric studies was performed with three different transient motions and various surrounding soils. The results showed that the soil stratigraphy and excitation motions significantly influenced the dynamic behavior of the vertical shaft. Maximum values of the shear force and bending moment occurred near an interface between the soil layers. In addition, deformations and load distributions of the vertical shaft were highly influenced by the amplified seismic waves on the vertical shaft constructed in multi-layered soils. Throughout the comparison results between the dynamic analysis method and the RDM, the results from the dynamic analyses showed good agreement with those from the RDM calculated by a double-cosine method.

Seismic performance of gravity-load designed concrete frames infilled with low-strength masonry

  • Siddiqui, Umair A.;Sucuoglu, Haluk;Yakut, Ahmet
    • Earthquakes and Structures
    • /
    • v.8 no.1
    • /
    • pp.19-35
    • /
    • 2015
  • This study compares the seismic performances of two reinforced concrete frame specimens tested by the pseudo-dynamic procedure. The pair of 3-storey, 3-bay frames specimens are constructed with typical characteristics of older construction which is lacking seismic design. One of the specimens is a bare frame while the other is infilled with low-strength autoclave aerated concrete (AAC) block masonry. The focus of this study is to investigate the influence of low strength masonry infill walls on the seismic response of older RC frames designed for gravity loads. It is found that the presence of weak infill walls considerably reduce deformations and damage in the upper stories while their influence at the critical ground story is not all that positive. Infill walls tend to localize damage at the critical story due to a peculiar frame-infill interaction, and impose larger internal force and deformation demands on the columns and beams bounding the infills. Therefore the general belief in earthquake engineering that infills develop a second line of defence against lateral forces in seismically deficient frames is nullified in case of low-strength infill walls in the presented experimental research.

A Discussion on the Definitions of Seismic Coefficient for Gravity Quay Wall in Korea (국내 중력식 안벽의 수평지진계수 산정 방법에 대한 고찰)

  • Lee, Moon Gyo;Jo, Seong Bae;Cho, Hyung Ik;Park, Heon Joon;Kim, Dong Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.77-85
    • /
    • 2017
  • Pseudo-static approach has been conventionally applied for the design of gravity quay walls. In this method, the decision to select an appropriate seismic coefficient ($k_h$) is an important one, since $k_h$ is a key variable for computing an equivalent pseudo-static inertia force. Nonetheless, there is no unified standard for defining $k_h$. Likewise, port structure designers in Korea have a difficulty in choosing an appropriate $k_h$ definition, as there are conflicts in how $k_h$ is defined between the existing seismic code of port structures and the proposed new one. In this research, various seismic design codes for port structures were analyzed to compare the definitions of the seismic coefficient. The results were used for the proposing a unified seismic coefficient definition. Further, two dynamic centrifuge tests were performed with different wall heights (5 m, 15 m) to clarify the reference point of peak acceleration used in determination of $k_h$ according to the wall height. Results from dynamic centrifuge experiments showed that correction factors for the peak ground acceleration considering both the wall height and allowable displacement are needed to calculate $k_h$.