• 제목/요약/키워드: proton ion

검색결과 320건 처리시간 0.036초

Monte Carlo simulations of chromium target under proton irradiation of 17.9, 22.3 MeV

  • Kara, A.;Yilmaz, A.;Yigit, M.
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3158-3163
    • /
    • 2021
  • Chromium material is commonly used for fusion plasma facing applications because of the low neutron activation property. The Monte Carlo method is one of the useful ways to investigate the ion-target interactions. In this study, Chromium target irradiated by protons was investigated using Monte Carlo based simulation tools. In this context, the calculations of radiation damage on Chromium material irradiated with protons at 17.9 and 22.3 MeV energies were carried out using GEANT4 and SRIM codes. Besides, the cross sections for proton interaction with Chromium target were calculated by the TALYS 1.9 code using CTM + FGM, BSFGM, and GSFM level densities. As a result, GEANT4, SRIM and TALYS 1.9 codes provide a suitable tool for the predictions of radiation damage and cross cross section with proton irradiation.

I-V and C-V measurements or fabricated P+/N junction mode in Antimony doped (111) Silicon

  • Jung, Won-Chae
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권2호
    • /
    • pp.10-15
    • /
    • 2002
  • In this paper, the electrical characteristics of fabricated p+-n junction diode are demonstrated and interpreted with different theoretical calculations. Dopants distribution by boron ion implantation on silicon wafer were simulated with TRIM-code and ICECaEM simulator. In order to make electrical activation of implanted carriers, thermal annealing treatments are carried out by RTP method for 1min. at $1000^{circ}C$ under inert $N_2$ gas condition. In this case, profiles of dopants distribution before and after heat treatments in the substrate are observed from computer simulations. In the I-V characteristics of fabricated diodes, an analytical description method of a new triangular junction model is demonstrated and the results with calculated triangular junction are compared with measured data and theoretical calculated results of abrupt junction. Forward voltage drop with new triangular junction model is lower than the case of abrupt junction model. In the C-V characteristics of diode, the calculated data are compared with the measured data. Another I-V characteristics of diodes are measured after proton implantation in electrical isolation method instead of conventional etching method. From the measured data, the turn-on characteristics after proton implantation is more improved than before proton implantation. Also the C-V characteristics of diode are compared with the measured data before proton implantation. From the results of measured data, reasonable deviations are showed. But the C-V characteristics of diode after proton implantation are deviated greatly from the calculated data because of leakage currents in defect regions and layer shift of depletion by proton implantation.

Application of CRAMPS for a Phase Transition in H+-ion irradiated TlH2PO4

  • Kim, Se-Hun;Han, J.H.;Lee, Cheol-Eui;Lee, Kwang-Sei;Kim, Chang-Sam;Dalal, N.S.;Han, Doug-Young
    • 한국자기공명학회논문지
    • /
    • 제14권2호
    • /
    • pp.134-143
    • /
    • 2010
  • We studied the hydrogen-bonded $TlH_2PO_4$ (TDP) ferroelectrics treated with the proton-beam bombardment. The TDP material was irradiated with 1-MeV proton beam at a dose of $10^{15}/cm^2$. In order to analyze the hydrogen environment in TDP, we carried out the $^1H$ high resolution nuclear magnetic resonance (NMR) - i.e., Combined Rotation And Multiple Pulse Spectroscopy (CRAMPS) measurement. The isotropic chemical shift of hydrogen indicates its displacive property is related to the $PO_4$ lattice deformation which occurs throughout the antiferroelectric-, the ferroelastic- and the paraelastic-phase transitions. The temperature dependence of $\sigma_{iso}$ reveals the electronic charge redistribution is induced by the proton-beam irradiation and the elastic property.

Proton Conductivity of Niobium Phosphate Glass Thin Films

  • Kim, Dae Ho;Park, Sung Bum;Park, Yong-il
    • 한국재료학회지
    • /
    • 제28권5호
    • /
    • pp.308-314
    • /
    • 2018
  • Among the fuel cell electrolyte candidates in the intermediate temperature range, glass materials show stable physical properties and are also expected to have higher ion conductivity than crystalline materials. In particular, phosphate glass has a high mobility of protons since such a structure maintains a hydrogen bond network that leads to high proton conductivity. Recently, defects like volatilization of phosphorus and destruction of the bonding structure have remarkably improved with introduction of cations, such as Zr4+ and Nb5+, into phosphate. In particular, niobium has proton conductivity on the surface because of higher surface acidity. It can also retain phosphorus content during heat treatment and improve chemical stability by bonding with phosphorus. In this study, we fabricate niobium phosphate glass thin films through sol-gel processing, and we report the chemical stability and electrical properties. The existence of the hydroxyl group in the phosphate is confirmed and found to be preserved at the intermediate temperature region of $150-450^{\circ}C$.

An Amperometric Proton Selective Sensor with an Elliptic Microhole Liquid/Gel Interface for Vitamin-C Quantification

  • Faisal, Shaikh Nayeem;Hossain, Md. Mokarrom;Lee, Hye-Jin
    • Journal of Electrochemical Science and Technology
    • /
    • 제1권2호
    • /
    • pp.121-126
    • /
    • 2010
  • An amperometric ascorbic acid selective sensor utilizing the transfer reaction of proton liberated from the dissociation of ascorbic acid in aqueous solution across an elliptic micro-hole water/organic gel interface is demonstrated. This redox inactive sensing platform offers an alternative way for the detection of ascorbic acid to avoid a fouling effect which is one of the major concerns in redox based sensing systems. The detection principle is simply measuring the current change with respect to the assisted transfer of protons by a proton selective ionophore (e.g., ETH 1778) across the micro-hole interface between the water and the polyvinylchloride-2-nitrophenyloctylether gel phase. The assisted transfer reaction of protons generated from ascorbic acid across the polarized micro-hole interface was first characterized using cyclic voltammetry. An improved sensitivity for the quantitative analysis of ascorbic acid was achieved using differential pulse stripping voltammetry with a linear response ranging from 1 to $100\;{\mu}M$ concentrations of ascorbic acid. As a demonstration, the developed sensor was applied for analyzing the content of vitamin-C in different types of commercial pharmaceutical tablets and syrups, and a satisfactory recovery from these samples were also obtained.

Preparation and Characterization of Proton Conducting Membranes by Blending PVC-g-PHEA and PVA

  • Koh, Jong-Kwan;Choi, Jin-Kyu;Seo, Jin-Ah;Zeng, Xiaolei;Kim, Jong-Hak
    • Korean Membrane Journal
    • /
    • 제11권1호
    • /
    • pp.1-7
    • /
    • 2009
  • This work reports the preparation of proton conductive crosslinked polymer electrolyte membranes by blending poly(vinyl chloride)-g-poly(hydroxyl ethyl acrylate) (PVC-g-PHEA) and poly(vinyl alcohol) (PVA). The PHEA chains of the graft copolymer were crosslinked with PVA using sulfosuccinic acid (SA) via the esterification reaction between -OH of polymer matrix and -COOH of SA. The PVC-g-PHEA graft copolymer was synthesized via atom transfer radical polymerization (ATRP) using direct initiation of the secondary chlorines of PVC backbones. Ion exchange capacity (IEC) continuously increased with increasing concentrations of SA, due to the increasing portion of charged groups in the membrane. However, the water uptake increased up to 20.0 wt% of SA concentration above which it decreased monotonically. The membrane exhibited a maximum proton conductivity of 0.026 S/cm at 20.0 wt% of SA concentration, which is presumably due to competitive effect between the increase of ionic sites and the crosslinking reaction.

Development of neutron time-of-flight measurement system for 1.7-MV tandem proton accelerator with lithium target

  • Lim, Soobin;Kim, Donghwan;Kang, Jin-Goo;Dang, Jeong-Jeung;Lee, Pilsoo;Kim, Geehyun;Chung, Kyoung-Jae;Hwang, Y.S.
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.437-441
    • /
    • 2022
  • In this study, we developed a neutron time-of-flight (nTOF) measurement system for a 1.7-MV tandem proton accelerator with a target covered with 300-nm-thick lithium (Li) layer. With implementation of beam chopping module after its ion source, the accelerator is configured to operate in pulsed-beam mode with a pulse width <50 ns at 20-kHz repetition rate. This enables the gamma flash-type nTOF measurement system to identify the neutron generated with 3-MeV proton beam energy. The nTOF system consists of a 30" cylindrical NaI(Tl) and four stilbene scintillation detectors. The NaI(Tl) scintillator is placed 50 cm from the Li target to measure the time of beam irradiation on the target, and the stilbene detectors are placed 2 and 2.4 m away to measure nTOF at each location. The nTOF system successfully measured the generated neutron energy at irradiated proton energies of 2.6 and 3.0 MeV with an average energy resolution of 15%.

세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향 (Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy)

  • 김선영;이두현;조정근;정도형;김호식;최계숙
    • 대한방사선치료학회지
    • /
    • 제18권1호
    • /
    • pp.1-5
    • /
    • 2006
  • 목 적: 세기조절 방사선치료의 환자별 정도관리는 이온전리함을 이용한 일정 지점에서의 절대 선량 측정과 필름을 이용한 상대 선량측정의 두 단계로 구성된다. 이온전리함을 이용한 절대 선량 측정은 동일한 지점에서 치료계획상의 점선량과 실제 측정 점선량 간의 일치도에 대한 정보를 제공한다. 일반적으로 정확한 점선량을 측정하기 위해 volume이 작은 0.015 cc 이온전리함(pin point chamber, PTW, Germany)을 사용하고 있다. 그러나 이 경우 이온전리함의 볼륨이 작아 선량의 오차가 크게 나타나는 경우도 있어, 적합한 볼륨의 이온전리함 사용이 권고되기도 한다. 따라서 볼륨이 다른 세 가지의 이온전리함을 이용하여 점선량을 측정하여 치료계획상의 점 선량과 비교해 보고, 0.015 cc 이온전리함을 이용한 세기조절 방사선치료에서의 절대 점선량 측정의 유효성을 평가해 보고자 한다. 대상 및 방법: 두경부(Head & Neck) 종양의 세기조절 방사선치료가 요구되는 환자 6명을 대상으로 Sliding-window 방법의 IMRT 치료계획을 수립하였으며 치료기는 21EX(Varian, USA) 선형가속기의 6 MV 광자선을 사용하였다. 측정 조건은 120 millenium MLC를 이용하여 Gantry 0도에서 300 MU/min의 선량률로 선원-이온전리함(source-axis-distance)거리를 100 cm, 고체팬텀의 표면으로부터 5 cm 깊이에 이온전리함을 위치시켰다. 치료계획용 컴퓨터(CAD-Plan, USA)에서 결정된 결과를 0.015 cc(pin point, type 31014, PTW, Germany), 0.125 cc(micro type 31002, PTW, Germany ), 0.6 cc(famer type 30002, PTW, Germany) 전리함에 각각 조사하여 측정치를 비교 분석하였다. 측정점은 선량값의 변화가 상대적으로 적은 선량 저변동 영역(Low-gradient area)에 위치시켰다. 결 과: 각각의 이온전리함을 이용하여 측정한 결과 0.015 cc의 경우 평균 ${\pm}0.91%$, 0.125 cc의 경우 ${\pm}0.52%$, 0.6 cc의 경우 ${\pm}0.76%$로 0.125 cc 이온전리함의 경우가 모든 측정조건에서 가장 적은 오차를 보였다. 결 론: 세기조절 방사선치료에 있어서 선량의 평가는 매우 중요하다. 방사선치료가 정밀해지는 만큼 정확한 선량평가가 이루어져야 한다. 점선량을 평가하기 위해 제작된 0.015 cc 이온전리함은 작은 출력신호와 큰 신호 대 잡음비가 절대 선량 측정 시 선량오차를 발생시키는 큰 요인으로 작용할 수 있다. 반면에 이온전리함의 볼륨이 큰 경우 출력신호가 크므로 정확한 선량을 반영할 수 있으나, 작은 측정점에 이온전리함을 정확히 위치시키기 어려워 절대 점선량을 측정하기 어려운 단점이 있다. 따라서 본 연구의 결과에서 본 바와 같이 세기조절 방사선치료의 절대 점선량 측정에는 오차가 상대적으로 적은 0.125 cc 이온전리함의 사용이 고려되어야 한다.

  • PDF

베타-갈락토시데이즈를 이용하여 합성된 Benzyl Alcohol Galactoside의 NMR Spectroscopy 및 Mass spectrometry (NMR Spectroscopy and Mass Spectrometry of Benzyl Alcohol Galactoside synthesized using β-Galactosidase)

  • 이향렬;정경환
    • 한국응용과학기술학회지
    • /
    • 제36권1호
    • /
    • pp.84-89
    • /
    • 2019
  • 대장균 효소 ${\beta}$-gal를 이용하여 합성된 BzO-gal의 분자구조를 NMR ($^1H$-와 $^{13}C$-)과 고성능 mass spectrometry를 이용하여 분석하였다. BzO-gal은 $^1H$ NMR에서 14개의 proton으로부터 12개의 피크를 나타내었다. 방향족 고리에서 오는 5개의 proton 피크와 벤질기의 $CH_2$에서 오는 2개의 proton 피크는 벤질알코올이 존재함을 나타낸다. 지방족 사슬 영역인 ${\delta}_H$ 4.32 ~ 3.46 ppm에서 나타나는 7개의 proton 피크로부터 단당류가 도입되었음을 확인할 수 있었다. $^{13}C$ NMR 스팩트럼에서 나타난 11개의 carbon 피크도 또한 벤질알코올에 단당이 도입되었음을 나타낸다. BzO-gal의 분자량을 확인하기 위하여 mass spectrometry 로 분석한 결과 m/z가 293.0994인 BzO-gal의 sodium adduct ion($[M+Na]^+$)을 확인할 수 있었다. 이러한 결과를 바탕으로 세포독성이 감소된 첨가물 개발을 기대하고 있으며, 추가적인 후속연구를 진행할 예정이다.