• Title/Summary/Keyword: protocol parameter

Search Result 161, Processing Time 0.036 seconds

Node Balanced CNC Routing Protocol for Low Power and Lossy Networks (저전력 손실 네트워크를 위한 노드 균형 CNC 라우팅 프로토콜)

  • Kim, Tae-Jung;Joung, Jinoo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.5
    • /
    • pp.123-128
    • /
    • 2019
  • The Internet Engineering Task Force (IETF) proposed IPv6 Routing Protocol for Low-power Lossy Network (RPL) as a routing protocol for Low Power and Lossy Networks (LLN). In RPL networks, only a few parent nodes are connected to many child nodes, which is called Thundering Herd Phenomenon. To solve this problem, it has been considered to limit the maximum number of child nodes connected per node using the CNC (Child Number Count) parameter. However, the problem remains that some parent nodes can be attached with as many as the maximum number of child nodes. How to determine the maximum CNC value is yet another problem. Therefore, in this paper, we propose an algorithm that evenly distributes the number of child nodes connected per node, to solve the Thundering Herd Phenomenon problem. The performance of the proposed algorithm is compared with that of the conventional RPL using CNC. As a result, we showed that the proposed algorithm performs better in terms of load balancing.

Employing a fiber-based finite-length plastic hinge model for representing the cyclic and seismic behaviour of hollow steel columns

  • Farahi, Mojtaba;Erfani, Saeed
    • Steel and Composite Structures
    • /
    • v.23 no.5
    • /
    • pp.501-516
    • /
    • 2017
  • Numerical simulations are prevalently used to evaluate the seismic behaviour of structures. The accuracy of the simulation results depends directly on the accuracy of the modelling techniques employed to simulate the behaviour of individual structural members. An empirical modelling technique is employed in this paper to simulate the behaviour of column members under cyclic and seismic loading. Despite the common modelling techniques, this technique is capable of simulating two important aspects of the cyclic and seismic behaviour of columns simultaneously. The proposed fiber-based modelling technique captures explicitly the interaction between the bending moment and the axial force in columns, and the cyclic deterioration of the hysteretic behaviour of these members is implicitly taken into account. The fiber-based model is calibrated based on the cyclic behaviour of square hollow steel sections. The behaviour of several column archetypes is investigated under a dual cyclic loading protocol to develop a benchmark database before the calibration procedure. The dual loading protocol used in this study consists of both axial and lateral loading cycles with varying amplitudes. After the calibration procedure, a regression analysis is conducted to derive an equation for predicting a varying calibrated modelling parameter. Finally, several nonlinear time-history analyses are conducted on a 6-story steel special moment frame in order to investigate how the results of numerical simulations can be affected by employing the intended modelling technique for columns instead of other common modelling techniques.

Implementation of Wireless PGN Analyzer for ISOBUS network

  • Tumenjargal, Enkhbaatar;Badarch, Luubaatar;Lee, Kangsan;Ham, Woonchul;Doopalam, Enkhzul;Togooch, Amartuvshin
    • Smart Media Journal
    • /
    • v.4 no.2
    • /
    • pp.46-54
    • /
    • 2015
  • Communication between ECUs (Electronic Control Units) in agricultural machineries tends to use IS011783 widely, that is PGN (Parameter Group Number) based communication protocol lays on CAN protocol by altering its identifier part. Messages in line are transferred and received between ECUs according to ISO11783 standard. This paper discusses about design of wireless monitoring system. We used an ARM Cortex-M3 microcontroller embedded development board and marvel8686 wireless module. The wireless ISOBUS monitoring system, attached to communication line, reads messages, interpret them, and display them on the screen in easily comprehendible form. It can be used to generate messages and monitor the traffic on physical bus systems. The monitoring system connected to ECUs, monitor and simulate real traffic of communication and functionality of the ECUs. In order to support our work, we have implemented the monitoring tool. The development consists of two parts: GUI of the application and firmware level programming. Hence the monitoring system is attached to the communication line and equipped by Wi-Fi module; farmer/dispatcher in a farm monitors all messages in communication line on personal computer and smart device.

End-to-end Transmission Performance of VoIP Traffics based on Mobility Pattern over MANET with IDS (IDS가 있는 MANET에서 이동패턴에 기반한 VoIP 트래픽의 종단간 전송성능)

  • Kim, Young-Dong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.7
    • /
    • pp.773-778
    • /
    • 2014
  • IDS(Intrusion Detection System) can be used as a countermeasure for blackhole attacks which cause degrade of transmission performance by causing of malicious intrusion to routing function of networks. In this paper, effects of IDS for transmission performance based on mobility patterns is analyzed for MANET(Mobile Ad-hoc Networks), a suggestion for effective countermeasure is considered. Computer simulation based on NS-2 is used in performance analysis, VoIP(Voice over Internet Protocol) as an application service is chosen for performance measure. MOS(Mean Opinion Score), call connection ratio and end-to-end delay is used as performance parameter.

Intrabed and Interbed Networks for Patient Monitoring (환자 모니터링을 위한 인트라베드 및 인터베드 통신망)

  • Park, Seung-Hun;Woo, Eung-Je;Kim, Kyung-Soo;Choi, Keun-Ho;Kim, Seung-Tae;Lee, Hee-Cheol;Seo, Jae-Joon;Kim, Hyung-Jin
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.285-289
    • /
    • 1997
  • In this paper, we describe the intrabed and interbed network in a developed patient monitoring system. Intrabed network handles data communication among the main unit of a bedside monitor and parameter modules plugged in it. Interbed network deals with a higher level data communication among many bedside monitors, central stations, DB servers, and clinical workstations. Analyzing the data communication requirements in each stage of the system, we designed the intrabed network based upon RS-485 and HDLC protocol with 1Mbps data rate. Interbed network is designed to utilize the industry standard 10Base-T Ethernet with TCP/IP and UDP protocol. We present the specifications and the performances of the developed data communication networks in the patient monitoring system.

  • PDF

Development of a Patient Monitoring System Overall Architecture and Specifications (환자모니터링시스템의 개발 : 전체구조 및 기본사양)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • We have developed a patient monitoring system including module-based bedside monitors, interbed network, central stations, clinical workstations, and DB servers. A bedside monitor with a color LCD can accommodate up to 3 module cases and 21 different modules. Six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmoyaph are provided as parameter modules. In a single bedside monitor, modules and a module controller communicate with IMbps data rate through an intrabed network based on RS-485 and HDU protocol. At the same time, it communicates with other bedside monitors and central stations through interbed network based on 1 OMbps Ethernet and TCP/IP protocol. Central stations using 20" color CRT monitors can be connected with many bedside monitors and they display 18 channels of waveforms simultaneously. Clinical workstations are used mainly for the review of patient datE In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we have developed a relational database server dedicated to the patient monitoring system. Software for bedside monitor, central station, and clinical workstation fully utilizes graphical user interface techniques and all functions are controlled by a rotate/push button on the bedside monitor arid a mouse on the central station and clinical workstation. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances.nces.

  • PDF

Throughput Analysis of ETSI BRAN HIPERLAN/2 MAC Protocol Taking Guard Timing Spaces into Consideration

  • Ko, You-Chang;Son, Yong-Tae;Shin, Yong-Eok;Lee, Hyong-Woo;Cho, Choong-Ho
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04d
    • /
    • pp.515-517
    • /
    • 2003
  • In this paper we examine the effects of the required portions of guard timing spaces in a MAC frame of ETSI BRAN HIPERLAN/2 system such as inter-mobile guard timing space in UL(Up Link) duration, inter-RCH(Random CHannel) guard timing space, sector switch guard timing space. In particular, we calculate the number of OFDM(Orthogonal Frequency Division Multiplexing) symbols required for these guard timing spaces in a MAC frame. We them evaluate the throughput of HIPERLAN/2 system as we vary parameter such as the guard time values defined in [2], the number of DLCCs(Data Link Control Connections), and the number of RCHs. Finally we show by numerical results that the portions for the 새심 summation of required guard timing spaces in a MAC frame are not negligible, and that they should be properly considered when trying to evaluate the performance of MAC protocol of HIPERLAN/2 system and also when determining the number of RCHs as well as the number of DLCCs in UL PDU trains at an AP/CC(Access Point/Central Controller).

  • PDF

Modifications of DCF Scheme to Alleviate Jitter Property in WLANs (무선 랜의 지터 성능 개선을 위한 DCF 개선 방안)

  • Kang, Dong-Hun;Seok, Seung-Joon
    • Journal of Internet Computing and Services
    • /
    • v.9 no.5
    • /
    • pp.153-163
    • /
    • 2008
  • Almost literature has so far proposed the modifications to IEEE 802.11 DCF MAC protocol to improve system throughput and average delay. Jitter(variance in packet delays) is, however, considered as an important QoS parameter for real-time streaming service which is popularized increasingly. Unfortunately, legacy access protocol for WLAN can't support the jitter. This paper proposes two schemes modifying the DCF MAC protocol to reduce the average value of jitter for multimedia frames arrived at received nodes. The one scheme, referred to as DCW-DCF(Decreasing Contention Window-DCF), reduces CW(Contention Window) size by half whenever a transmitted frame collided against other frames and back-off happens. Also, it increase initial CW size according as the link utilization and the collision probability increase. The other scheme, referred to as D-DIFS(Differential-DIFS), assigns different values to DIFS. That is, the DIFS interval is deceased as the number of back-off for a frame increases. In this paper, the two schemes are evaluated through simulation using ns2 and simulation results show that the proposed schemes are effective for improving the jitter property of standard WLAN.

  • PDF

Comparison of Two Vitrification Methods of In Vitro Development Oocytes Collected from Porcine Antral Follicles Using Open Pulled Straw (OPS) Techniques

  • An, Mihyun;Hong, Daewuk;Son, Dongsoo;Seok, Hobong
    • Proceedings of the Korean Society of Embryo Transfer Conference
    • /
    • 2002.11a
    • /
    • pp.84-84
    • /
    • 2002
  • The advantages of the OPS techniques(Vajta G et al, Mol Reprod Dev 51: 53-58,1998) give 1) high survival rates of various types of eggs, 2) quick and simple process, 3) inexpensive equipment and reduced chilling injury. The efficiency of IVM/IVF technique in the porcine species is relatively lower than that obtained in other species such as ruminants. Two experiments were designed to investigate the effects of in-vitro fertilization of porcine oocytes matures using different OPS protocol for chilling and warming of vitrification. Porcine oocytes from ovaries collected at abattoir were matured for 44 hours in TCM199 Earle's salt supplemental with pyruvate, pff, L-cysteine, hormones and gentamycin. Oocytes were denuded and fertilized with frozen boar semen by common method. Porcine embryos produced routinely by in-vitro culture system of NCSU23 medium. The vitrification and the warming were conducted by OPS method with the glass micropipette instead of straw vessels and modified the protocol of G.Vajta(1999). In Exp 1, Chilling/Warming:Holding Medium(HM)+EG+DMSO/HM +sucrose Medium(SM) at 39$^{\circ}C$ warm stage. In Exp 2, : PBS+CS+EG+Ficoll+ Trehalose/PBS+Trehalose at 25$^{\circ}C$ stage. Filling, freezing, packing, thawing out and further culturing were performed to follow the basic protocol of G Vajta. During IVM-lVC and post-warming, fertilization parameter and developmental potential were compared to and statistically analysed. It was not significantly different from Exp 1 and Exp 2 but 25$^{\circ}C$ of stage was slightly higher on the morula/blastocyst forming rate and better atmosphere for worker than that at 39$^{\circ}C$ stage.

  • PDF

A Study of NMEA 2000 Protocol Application for Ship Electrical Power Converter Monitoring System (NMEA 2000 프로토콜을 적용한 선박 전력 컨버터 모니터링 시스템에 관한 연구)

  • Hong, Ji-Tae;Park, Dong-Hyun;Yu, Yung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.288-294
    • /
    • 2011
  • In this paper, the FPGA-based SoC board (Xilinx Virtex-4 ML401 EVM) is adopted to control electrical power inverter system. For marine application, its performance is shown on PC-based system for monitoring electrical characteristics of a power inverter using by the NMEA 2000 protocol. This power inverter system is achieved in Real-Time monitoring and control by dual micro-processor operation on embedded FPGA-based SoC board. One micro processor is for control (Control processor) electrical power inverter using by PWM signal. And the other microprocessor (Communication processor) is for communication with PC-based monitoring system. The two-processor is communicating each other using by dual-port ram (DPRAM). PC-based system user can control and monitor information of the electrical power inverter via NMEA 2000 based communication processor. Control and monitoring information includes the inverter status and configuration. SoC board converts this information to Parameter Group Numbers (PGNs) in the NMEA 2000 protocol. This system can be applied to marine power electronics for distributed power generation, transmission or regulation systems on the ship.