• Title/Summary/Keyword: protocol inspection

Search Result 65, Processing Time 0.027 seconds

SOC Bus Transaction Verification Using AMBA Protocol Checker

  • Lee, Kab-Joo;Kim, Si-Hyun;Hwang, Hyo-Seon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.2
    • /
    • pp.132-140
    • /
    • 2002
  • This paper presents an ARM-based SOC bus transaction verification IP and the usage experiences in SOC designs. The verification IP is an AMBA AHB protocol checker, which captures legal AHB transactions in FSM-style signal sequence checking routines. This checker can be considered as a reusable verification IP since it does not change unless the bus protocol changes. Our AHB protocol checker is designed to be scalable to any number of AHB masters and reusable for various AMBA-based SOC designs. The keys to the scalability and the reusability are Object-Oriented Programming (OOP), virtual port, and bind operation. This paper describes how OOP, virtual port, and bind features are used to implement AHB protocol checker. Using the AHB protocol checker, an AHB simulation monitor is constructed. The monitor checks the legal bus arbitration and detects the first cycle of an AHB transaction. Then it calls AHB protocol checker to check the expected AHB signal sequences. We integrate the AHB bus monitor into Verilog simulation environment to replace time-consuming visual waveform inspection, and it allows us to find design bugs quickly. This paper also discusses AMBA AHB bus transaction coverage metrics and AHB transaction coverage analysis. Test programs for five AHB masters of an SOC, four channel DMAs and a host interface unit are executed and transaction coverage for DMA verification is collected during simulation. These coverage results can be used to determine the weak point of test programs in terms of the number of bus transactions occurred and guide to improve the quality of the test programs. Also, the coverage results can be used to obtain bus utilization statistics since the bus cycles occupied by each AHB master can be obtained.

Efficacy of new inspection system of Anticancer Drug Prescription (새로운 항암제 처방 감사 시스템 도입을 통한 의료의 질 향상)

  • Kim, M.S.;Kim, Y.K.;Lee, Y.J.;Choi, Y.J.;Shin, H.Y.;Song, Y.C.
    • Quality Improvement in Health Care
    • /
    • v.14 no.2
    • /
    • pp.125-132
    • /
    • 2008
  • Background : The number of outpatient injected anticancer drug is increasing. and the pathway of prescribing, compounding, and injecting anticancer drug is processed very rapidly in out-patient department. Moreover, Dose of anticancer drug is often changed depending on side effect of patients. So we need more effective inspection of anticancer drug prescriptions. The purpose of this study was to analyze the prescription errors for anticancer drugs in Out-Patient Department and to suggest system to prevent them. Method : The study took place at Asan Medical Center from July to September 2007. The pharmacists performed inspection of anticancer drug prescriptions before compounding and injecting. We used protocol-based anticancer drug order program and Electronic Medical Record (EMR). Result : During the study period, we analyzed 4683 prescriptions for out-patient. And we detected 55 medication errors (1.2%). Most common errors included dosage above or below the correct ones (56.3%), followed by incorrect treatment duration. Because most of dosing errors were in the range of usual dosage, it was hard to detect them. So when inspecting the prescription, we considered the medical records of individual patients. As a result, we could raise the efficiency of intervention. Therefore inspection using EMR could possibly reduce the number of anticancer drug errors. Conclusion : we are preventing the medication errors on stability and dosage above or below the maximum therapeutic dose according to the previous inspection system. However most of dosing errors were in the range of usual dosage according to the result of this study. Because of there was interpatient variability of dosage depending adverse effect. For improvement of quality assurance, we suggest inspection system based on patient's medical history.

  • PDF

Thickness Measurement of Pipe Using Tangential Radiography (Tangential Radiography를 이용한 배관의 두께 평가법)

  • Lee, S.S.;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.205-210
    • /
    • 1998
  • 이미 오래전부터 국내외에서 석유화학공장 등의 보온 배관에서 보온재를 벗기지 않고 배관의 부식 손상 및 잔존두께를 평가하는데 방사선투과시험법을 적용해 오고 있다. 그러나 배관 용접부의 결함 탐상에 관한 방사선투과법에 대한 국제 및 국내 코드는 이미 마련되어 있지만 배관의 두께와 내부에 존재하는 부착물(deposit) 등의 두께를 측정하는 것에 관련한 국제 및 국내 코드는 미비되어 시험 절차 및 시험 결과에 대한 시비가 근본적으로 존재할 수 밖에 없을 뿐만 아니라 표준화된 시험 기술의 미비로 현장에서 많은 시행착오를 동반하였다. 그러나 최근 이 시험법에 대한 관련 원안(protocol)을 확정하기 위해 각국에서 개별적으로 수행되었던 기존의 연구 결과들이 취합되고 있으며 부족한 부분들에 대한 연구가 국제 공동 연구 형식으로 이뤄지고 있다. 따라서 본 연구에서는 tangential radiography를 적용하여 보온된 배관의 잔존 두께를 평가할 수 있는 시험 방법을 제시하고자 하였다.

  • PDF

Network Camera for CMOS Camera Module Inspection (CMOS 카메라 모듈 검사를 위한 네트워크 카메라)

  • 신은철;최병욱
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.809-813
    • /
    • 2004
  • In this paper, we developed a network camera for CMOS camera module inspection. The design, implementation details including embedded linux porting and CPLD logics, and performance of network camera are described. The network camera consists of SoC(S3C4530A), CPLD and CMOS image sensor. In order to image data of CMOS image sensor we designed capture logics on CPLD by using VHDL program. Embedded Linux such as uClinux is performed on the network camera to utilize development environment and TCP/IP protocol specification. The application is based on socket communication between GUI on PC and Embedded Linux based network camera. When JPEG compression is applied, the transmission speed was improved enough for this system to be used for an alternative of expensive CCTV or remote monitoring system in a power plant and uninhabited places.

  • PDF

Minimizing Security Hole and Improving Performance in Stateful Inspection for TCP Connections (TCP연결의 스테이트풀 인스펙션에 있어서의 보안 약점 최소화 및 성능 향상 방법)

  • Kim, Hyo-Gon;Kang, In-Hye
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.4
    • /
    • pp.443-451
    • /
    • 2005
  • Stateful inspection devices must maintain flow information. These devices create the flow information also for network attack packets, and it can fatally inflate the dynamic memory allocation on stateful inspection devices under network attacks. The memory inflation leads to memory overflow and subsequent performance degradation. In this paper, we present a guideline to set the flow entry timeout for a stateful inspection device to remove harmful embryonic entries created by network attacks. Considering Transmission Control Protocol (TCP) if utilized by most of these attacks as well as legitimate traffic, we propose a parsimonious memory management guideline based on the design of the TCP and the analysis of real-life Internet traces. In particular, we demonstrate that for all practical purposes one should not reserve memory for an embryonic TCP connection with more than (R+T) seconds of inactivity where R=0, 3, 9 and $1\leqq{T}\leqq{2}$ depending on the load level.

Suggestion of the Domestic CCTV Inspection Sewer Pipe Defect Codeby Sewer Defect Frequency Analysis (국내 하수관로 결함빈도 분석을 통한 CCTV 조사 결함항목 코드 제안)

  • Son, Jooyoung;Lee, Jaehyun;Kim, Jungryul;Oh, Jeill;Yoon, Sungsoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.623-634
    • /
    • 2016
  • Sewer condition assessment involves the determination of defective points and status of aged sewers by a CCTV inspection according to the standard manual. Therefore, it is important to establish a reliable and effective standard manual for identifying the sewer defect. In this study, analytic reviews of the CCTV inspection manuals of the UK, New Zealand, Canada and South Korea were performed in order to compare the defect codes and the protocols of condition assessment. Through this, we also established the standardized method for defect code and revised the calculation method of assigning the condition grade. Analyses of the types and frequencies of sewer defects that obtained by CCTV inspection of 7000 case results, showed that the joint defect and lateral defect were the most frequent defects that occurred in Korea. Some defect codes are found to be modified because those did not occur at all. This study includes a proposed new sewer defect codes based on sewer characteristics.

Suggestion of the defect score and condition grading protocol about sewer pipe (하수관로 결함 점수 및 상태 등급 판정 방법 제안)

  • Kim, Jungruyl;Lee, Jaehyun;Oh, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.21-28
    • /
    • 2017
  • This study was performed to propose the sewer defect scoring, and grading protocols for sewer condition assessment. For this, sewer defect scoring methods were comparatively analyzed and reviewed for four international condition assessment protocols, which are established based on WRc manual. As a result, we proposed a new protocol for sewer condition assessment, in which characteristics of sewer pipes are considered by segment. In reference to the PIM-3, the extent of ground subsidence was adopted to be of importance, and renewal scores increased in accordance with weighting of defects causing structural backfill materials. Also, defect grades of 'Hole' were extended to 5 levels of the grading, and 'Surface Damage' was excluded in defect assessment. The addition of 'Buckling' resulted in reduction of weights in 'Surface Damage' and 'Lining Defects'.

Research For Reducing Patient Dose that Low Extremity CT Angiography Using Automatic Current Selection (하지동맥조영 전산화단층촬영에서 자동선량 조절장치를 이용한 환자선량 감소 연구)

  • An, Hyeong-Theck;Kim, Jae-Yeol;Yeo, Woon-Sik;Park, Yong-Sung;Lee, Gui-Won;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.45-53
    • /
    • 2013
  • Purpose : Fixed way of mAs previously Low Extremity Computed Tomography Angiography(LECTA) examination were used. Automatic Current Selection(ACS) to use for the purpose of reducing the dose when Low Extremity Computed Tomography Angiography examining patients. Materials and methods : Were analyzed from July 2011 to July 2012 MDCT examination of Dose Length Product(DLP) LECTA 116 Case. It was defined as previous inspection methods(Old protocol). CT workstation is set to 100 mAs and 150 mAs protocol based on the patient's weight 70kg examined by LECTA. We defined as 'New protocol' that applies to ACS. The data collection period are 76 cases from October 2012 to January 2013 Results : 1. Average Total DLP of 'Old protocol' is 3602.943 $mGy^*cm$. 2. Average Total DLP of 'New protocol' is 1762.977 $mGy^*cm$. 3. Due to the 'New Protocol' use of Total DLP was reduced by approximately 51 %. Phase-specific dose reduction is as follows. Pre(33.62 %), Artery(64.63 %), Delay(49.0 %) 4. Using One way ANOVA Analysis of fluctuations obtained DLP is as follows. 'Old protocol', 'New protocol' a value of P < 0.001, P = 0.882 values were obtained. Conclusions : Dose reduction of 51 % is a useful study that proves. The results obtained using the ACS, the effects of a dose reduction of 51 % was obtained. Therefore, it has been proven to be a useful way. Statistics using SPSS version came out of the 'Old protocol' P-value P < 0.0001. This result means that the DLP a large difference values. On the other hand, The results of the 'New protocol' was P = 0.882. These results means to that small and regularly was fluctuations of the dose. The use of ACS, you can get a reduction of the dose and will able to get the effect of reducing the dose errors.

  • PDF

Classification of Security Checklist Items based on Machine Learning to Manage Security Checklists Efficiently (보안 점검 목록을 효율적으로 관리하기 위한 머신러닝 기반의 보안 점검 항목 분류)

  • Hyun Kyung Park;Hyo Beom Ahn
    • Smart Media Journal
    • /
    • v.11 no.11
    • /
    • pp.75-83
    • /
    • 2022
  • NIST in the United States has developed SCAP, a protocol that enables automated inspection and management of security vulnerability using existing standards such as CVE and CPE. SCAP operates by creating a checklist using the XCCDF and OVAL languages and running the prepared checklist with the SCAP tool such as the SCAP Workbench made by OpenSCAP to return the check result. SCAP checklist files for various operating systems are shared through the NCP community, and the checklist files include ID, title, description, and inspection method for each item. However, since the inspection items are simply listed in the order in which they are written, so it is necessary to classify and manage the items by type so that the security manager can systematically manage them using the SCAP checklist file. In this study, we propose a method of extracting the description of each inspection item from the SCAP checklist file written in OVAL language, classifying the categories through a machine learning model, and outputting the SCAP check results for each classified item.

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

  • Kim, Juhye;Shin, Dong Oh;Choi, Sang Hyoun;Min, Soonki;Kwon, Nahye;Jung, Unjung;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.123-136
    • /
    • 2018
  • The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerators, the ATP items were checked step by step and compared with the quality assurance (QA) test items of the AAPM TG-142 described for the medical accelerator QA. Based on the commissioning procedure, dose quality control protocol, and mechanical quality control protocol presented at international conferences, step-by-step check items and commissioning guidelines were derived. The risk management items at each stage were (1) 21 ionization chamber performance test items and 9 electrometer, cable, and connector inspection items related to the dosimetry system; (2) 34 mechanical and dose-checking items during ATP, 22 multileaf collimator (MLC) items, and 36 imaging system items; and (3) 28 items in the measurement preparation stage and 32 items in the measurement stage after commissioning. Because the items presented in these guidelines are limited in terms of special treatment, items and practitioners can be modified to reflect the clinical needs of the institution. During the system installation, it is recommended that at least two clinically qualified medical physicists (CQMP) perform a double check in compliance with the two-person rule. We expect that this result will be useful as a radiation safety management tool that can prevent radiation accidents at each stage during the introduction of radiotherapy and the system installation process.