A Study on Fire Spread between Office Room and Atrium in the Atrium Building

  • Lee, Su-Kyung;Kim, Jong-Hoon;Ko, Han-Mog
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.345-352
    • /
    • 1997
  • We could analyse the fire behavior using the developed software for fire safety assessment in a large space such as atrium. But Korean building law hasn't admitted the result of fire risk assessment in atrium. In the legislation fire resistant wall or shutter must be required between atrium and office rooms, That has obstructed development of building design and fire protection technique in Korea. From this point of view, we made scenarios of fire spread between atrium and office rooms, and then computed fire spread and fire phenomena using FASTLite and Breakl. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

An Experimental Study of Sprinkler system for Sandwich Panel Wall Protection (샌드위치패널 벽면보호용 스프링클러설비 적용 실험)

  • Seo, Dong-Hun;Kim, Won-Hyung;Kim, Jong-Hoon;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.37-43
    • /
    • 2017
  • Domestic sandwich panel buildings are widely used on walls and roofs of factories and warehouse facilities. Factory and warehouse facilities have high fire load and rapid spread of fire due to their use characteristics, leading to large fires. Due to the characteristics of materials, walls and roofs are collapsed, resulting in life damage and property damage. In this regard, this study examined domestic and international standards of sprinkler facilities to prevent ignition of sandwich panel walls. Also, in order to check whether the fire was prevented by installing the head on the wall of the sandwich panel, the fire test was carried out with 10 cm, 60 cm, and 120 cm from the wall along the sprinkler head installation standard of domestic fire safety standards. As a result of the fire test, it was confirmed that the sandwich panel was prevented from igniting when the head of water pressure 0.1 MPa and water quantity K-80 was installed. According to the separation distance, it was impossible to measure the temperature at 10 cm, but at 60 cm, At the maximum temperature of $525^{\circ}C$ and 120 cm, the maximum temperature of the wall of the sandwich panel was measured as $276^{\circ}C$. As a result of the fire test, considering the fire point of 450 degrees Celsius in the fire test of the sandwich panel, the distance from the sandwich panel wall to the combustible is more than 120 cm.

Noise Protection Roof: Partial Opening Effect for Noise Reduction (철도용 터널형 방음벽 개발연구: 설계 방향)

  • Kim, Tae-Min;Kim, Jeung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.6
    • /
    • pp.522-532
    • /
    • 2015
  • In the present study, a tunnel type soundproof wall with partial opening is proposed to reduce the environmental noise caused by railway vehicles traveling on bridges, which affects residents of high-rise apartment buildings; the study also attempts to minimize load due to wind and the weight of the wall. Applying the principles of computational fluid dynamics and structural mechanics, and the ray tracing method, a reduction in noise as well as of the overall weight of the soundproof walls is estimated. Analysis results show that the proposed soundproof wall with a partial opening weighs less, while reducing the wind loading by up to 30%. To prevent direct propagation of sound through openings in the wall, an acoustic louver, which is a type of silencer, could be considered for the opening. In order to achieve a similar noise effect with existing insulation material, the fluid flow and the insulation effect of the acoustic louver are analyzed. As the considered opening is in the range of 30~40% of the total length of the soundproof wall, the noise effect and wind load are reduced by 10dB and 25% respectively. Consequently, opening some part of tunnel type soundproof walls and installing louvers on the wall openings can have the effects of weight-reduction and reduced wind load. If a partial opening is applied with proper sound material application, a gain of an additional 5~10dB of noise reduction can be achieved.

Numerical Simulation of Vertical Wall Fires I. Turbulent Natural Convection Along Vertical Wall (수직벽화재의 수치 시뮬레이션 I. 수직벽 난류자연대류)

  • Park, Woe-Chul;Trouve, Arnaud
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.181-187
    • /
    • 2008
  • Numerical simulation of natural convection along a vertical wall was carried out to evaluate the computational fluid dynamics simulator, which is to be utilized for study of vertical wall fires. The computed velocity and temperature profiles were compared with measurements over the turbulent boundary layer formed along the wall of 4m high and constant temperature. It fumed out that the simulator with default parameters failed to predict the turbulent natural convection showing the boundary layer flow laminar. The grid size $\Delta$x=5mm, ${\Delta}y={\Delta}z=10mm$ and Smagorinsky constant of the large eddy simulation $C_s$=0.1 were chosen through parametric investigations. Though turbulent mixing was not enough, the velocity distribution near wall, peak velocity, and temperature profile in the turbulent boundary layer agreed well with the measurements.

Micromorphology and development of the epicuticular structure on the epidermal cell of ginseng leaves

  • Lee, Kyounghwan;Nah, Seung-Yeol;Kim, Eun-Soo
    • Journal of Ginseng Research
    • /
    • v.39 no.2
    • /
    • pp.135-140
    • /
    • 2015
  • Background: A leaf cuticle has different structures and functions as a barrier to water loss and as protection from various environmental stressors. Methods: Leaves of Panax ginseng were examined by scanning electron microscopy and transmission electron microscopy to investigate the characteristics and development of the epicuticular structure. Results: Along the epidermal wall surface, the uniformly protuberant fine structure was on the adaxial surface of the cuticle. This epicuticular structure was highly wrinkled and radially extended to the marginal region of epidermal cells. The cuticle at the protuberant positions maintained the same thickness. The density of the wall matrix under the structures was also similar to that of the other wall region. By contrast, none of this structure was distributed on the abaxial surface, except in the region of the stoma. During the early developmental phase of the epicuticular structure, small vesicles appeared on wallecuticle interface in the peripheral wall of epidermal cells. Some electron-opaque vesicles adjacent to the cuticle were fused and formed the cuticle layer, whereas electron-translucent vesicles contacted each other and progressively increased in size within the epidermal wall. Conclusion: The outwardly projected cuticle and epidermal cell wall (i.e., an epicuticular wrinkle) acts as a major barrier to block out sunlight in ginseng leaves. The small vesicles in the peripheral region of epidermal cells may suppress the cuticle and parts of epidermal wall, push it upward, and consequently contribute to the formation of the epicuticular structure.

A Study on Construction Manner of City Wall Parks in China Beijing (북경의 성곽역사공원 조성방식 연구)

  • Li, Ao-Fei;Kang, Tai-Ho
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.33 no.4
    • /
    • pp.129-139
    • /
    • 2015
  • Parks in order to find the inspiration and implication from their construction. The research is focused on a few cross-sectional city wall parks, which are Huangchenggen city wall park, Ming city wall park and Yuandadu city wall park. to come to the conclusion, it defines the generic concept of city wall park, clarifies the transitional process of the city of Beijing, organize the current situation and basis of the construction of the Beijing city wall parks. besides, by analyzing the Beijing city wall parks' specific construction manners including the basis of their planning, the support by government, planning functionality, landscape theme arrangement and gardening arrangement, the research puts forwards their construction characters and drawbacks. through comprehensive analysis on the aspects above, a series of inspirations are obtained for the construction of city wall parks. these include: specialized and legally valid regulation systems need to be setup before planning; government and citizens' proactive support is necessary for the protection of ancient city wall ruins and the construction of the city wall parks; when planning, existing situation should be utilized to the maximum extent, efficiency of space usage should be improved through smooth connection between different spacial locations.

Numerical Simulation of Vertical Wall fires II. Propane Fire (수직벽화재의 수치 시뮬레이션 II. 프로판 화재)

  • Park, Woe-Chul;Trouve, Arnaud
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.188-193
    • /
    • 2008
  • Numerical simulation was carried out for a propane fire of mass transfer rate 3g/m^2-s$ on a 1m high vertical wall. The objectives of this study are to confirm the outcomes of evaluation of the simulator through simulation of natural convection, and to compare the results of the wall fire with those of previous studies. It was confirmed that the simulated boundary layer was laminar at C_s=0.2$ while it was turbulent at C_s=0.1$. The z direction velocity showed lack of turbulent mixing as seen in the natural convection case, and the profiles of temperature and velocities were in relatively good agreement with those of experiment and previous simulation. It was found that the air entrainment into the boundary layer was well predicted.

The Retaining wall Design nearby Large Excavation for Developed Underground in Urban Area. (도심지 지하공간개발을 위한 대형 대심도 근접굴착 흙막이 설계사례)

  • Shin, Yung-Wok;Park, Jong-Min;Lee, Sung-Hwan;Lee, Bong-Yeol;Lee, Jung-Young;Chang, Huck-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.49-83
    • /
    • 2005
  • ESCP Project showed an urban excavation case and introduced design method for case of Soil-Structure behavior in urban excavation. In this case, a retaining structures design to analysis the behavior of retaining wall and adjacent structures in urban excavations was applied by using a Elasto-plastic beam and limit Equilibrium analysis and soil-structure interaction analysis. Reliable design of earth retaining structures and the ground adjacent to braced wall in urban excavation are often difficult due to many variable factors. The ground settlement and the damage of adjacent structures in urban excavation has been an imprtant issue. Therefore, the stability of the adjacent structures must be secured with the excavation support and research on the protection of adjacent structure is necessary.

  • PDF

Analysis of Generating Efficiency in PV Window System consequent on Apartment House Wall Reflectivity (공동주택 벽체 반사율에 따른 PV창호시스템 발전효율 분석)

  • Choi, Doo-Sung;An, Jun-Ho;Jeon, Hung-Chan;Do, Jin-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.31-39
    • /
    • 2016
  • This study did quantitative comparative evaluation of changes in generation consequent on reflectivity of the protruding wall near the widow in case of application of PV window system to an apartment house. To be concrete, this study did comparative analysis of the generation of (B) through the process of composing Mock-up (A)comprising the protruding window near the window and Mock-up(B) free of nearby wall interference, and giving change to the reflectivity of the wall (Case_1~3). The analysis result showed that the difference in generation was slight in case solar radiation was less than 10,000Wh in all three conditions. On the contrary, in case solar radiation was more than 10,000 Wh, the generation as against Module(B), was analyzed to be 87~91% in Case_1(5% reflectivity), 18~60% in Case_2(85% reflectivity), and 16~71% in case_3(93% reflectivity), respectively.

A Qualitative Understanding of the Critical Opinion and Environmental Values of College Students meeting the Young-Wall Dam Issue (영월댐 건설 문제를 둘러 싼 환경교육과 학생들의 비판적 견해와 환경가치에 대한 정성적 이해)

  • 구수정
    • Hwankyungkyoyuk
    • /
    • v.12 no.1
    • /
    • pp.276-293
    • /
    • 1999
  • An environmentally hot issue has arisen from the plan of Young-Wall Dam Construction at Tong river in Korea lately. The point at issue is which value is bigger between the water conservation for human use in future and the ecosystem protection for the intrinsic value of nature including animals and plants there. The purpose of this study is in the qualitative understanding of college students' critical thinking ability and opinion and the environmental values of them through the analysis of their writings. Various environmental values written in the 7th revised national curriculum of Korea are used as a criteria to investigate students' environmental values in their written opinions. Various environmental values are shown up to be handled such as the anthropocentrism, ecocentrism, pro-technology etc. Students of Dept. of Environment Teaching in the Kongju National University are the subject of this study. It shows that they have a deep understanding of the Young-Wall Dam issue and assert their opinions objectively and critically. Most of them(89.5%, n=17) are against the constructional plan of the Young-Wall Dam. Students who are for the plan are proved to have pro-technology value only and the others who are against to have various values including deer ecology.

  • PDF