Structural Design Guide Line of Composite Beam (내화피복이 생략된 합성보의 구조설계지침 제정을 위한 고찰)

  • Hong, Won-Kee;Kim, Jin-Min;Lee, Kyoung-Hun;Park, Seon-Chee;Kim, Jeom-Han
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.93-98
    • /
    • 2008
  • As high rise buildings and large span spatial structures are constructed, new composite members and construction techniques are continuously developed. Wide flange steel beam can be easily constructed but the fire proofing protection is necessary and the cost is high. Nowadays environmental pollution of structures is becoming a big issue. The material of fire proofing protection is not allowed to use for structural members in several countries because it cab be a cause of environment pollution. Composite beam is a new hybrid beam system which is not needed a fire proofing protection process. Composite beam has better construction capacity than that of RC system and has more economic advantages than that of wide flange steel beam. In this paper, structural design guide lines of composite beam were provided to apply design and construction.

Introduction of Fire Protection Technology and Its Design Method of Offshore Facilities (해양플랜트의 방화대책 및 설계기술 소개)

  • Koo, Myeong Jun;Choi, Jae Woong;Yoon, Ho Byung
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2013
  • The dimensioning accidental loads have been selected through suitable quantitative risk assessment and generally utilized important factors for offshore facility design. The fire hazard can be quantified with dimensioning fire loads. The main purposes of fire protection are to maintain the functionality of safety systems within evacuation period and to prevent the escalation from initial fire to uncontrolled catastrophic fire. This paper introduces the applications and the design methods of active and passive fire protections as representative measures of fire protection of offshore facilities. The passive fire protection requires the high initial installation cost and much difficulty on the operation of facilities and their maintenance. The oil major clients have asked the design contractors of offshore facilities to optimize the amount of passive fire protection with relevant engineering technology recently.

Monte Carlo simulation and study of REE/PET composites with wide γ-ray protection

  • Tongyan Cui;Ruixin Chen;Shumin Bi;Rui Wang;Zhongjian Ma;Qingxiu Jia
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2919-2926
    • /
    • 2023
  • In this paper, rare earth element (REE)/polyester composites were designed with lanthanum oxide, gadolinium oxide, and lutetium oxide as ray shielding agents, and polyethylene terephthalate (PET) as the base. Monte Carlo simulation was carried out using FLUKA software. We found that the radiation protection performance of the composite is affected by the type and amount of REE; a higher amount of REE equated to a better radiation protection performance of the composite. When the thickness of the composite and total thickness of the REE is constant, the number of superimposed layers inside the composite does not affect its shielding performance. Compared with a single-type REE/PET composite, a mixed-type REE/PET composite has a wider range of γ-ray absorption and better radiation protection performance. When the mass ratio of PET to REE is 2:8 and different types of REE are mixed with equal mass, several 0.2 cm-thick mixed-type REE/PET composites can shield >70% of 60 and 80 KeV γ-rays.

A Study on the Design Factors of Complex Damper for Ventilation and Fire Protection (환기 및 소방용 복합댐퍼의 설계인자에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.42-47
    • /
    • 2011
  • This study carried out the design and analysis of complex damper as basis study for development of complex damper for ventilation and fire protection. This study established design and analysis theory of complex damper based on process, kinematics mechanism and mechanism modelling of complex damper. And this study established engineering data construction and a source technology that can design each element of complex damper through motion analysis simulation based on design and analysis theory. Therefore, it got result that can apply comprehensively in development of complex damper for ventilation and fire protection from this study. Also, it sees that can ready control means and technological countermeasure of smoke to developed of complex damper with this study.

A Framework and Process Design for RFID Privacy Protection (RFID 프라이버시 보호 프레임웍 및 프로세스 설계에 관한 연구)

  • Kim, Jin-Soo
    • Journal of Information Technology Applications and Management
    • /
    • v.14 no.3
    • /
    • pp.151-168
    • /
    • 2007
  • RFID is an emerging technology and rapidly applied to various industries due to its high-tech characteristic and convenience. Although RFID provides valuable benefits. it might also generate serious privacy problems. Previous studies show that privacy issues should be incorporated in developing RFID systems and more detailed privacy protection methods. However. they just provide basic concept, rough guideline. and simple architecture about RFID privacy protection. Industry needs more structured framework and detailed systematic process to incorporate privacy issues into the RFID system. The purpose of this paper is to develop a framework and detailed process design of RFID privacy protection issues in retail industries. A framework is developed based on individual sensitivity concept, RFID contents, and interface with EPC global standard. Case study is applied to validate the framework and it turns out to be useful. It is expected that the proposed framework and process design would provide more systematic guide lines to solving RFID privacy problems.

  • PDF

Protection Design for EMI and Indirect Lightning Effect for RS-170a Video Signal (RS-170a 영상 신호에 대한 EMI 및 낙뢰 간접영향 보호 설계)

  • Cho, Seong-jin;Sim, Yong-gi;Kim, Sung-hun;Park, Jun-hyun
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.444-451
    • /
    • 2019
  • In this paper, we introduce the design consideration of the EMI and lightning induced transient protection circuit for RS-170a video signal on the avionics equipment. Avionics equipment is subject to the risk of malfunction or physical damage due to indirect lightning effect from lightning strike or electromagnetic interference from external environment. So in order to protect the avionics equipment from these effects, we should analyze the effect of electromagnetic interference and lightning strike on aircraft and apply protection design for each avionics device, but protection circuit may cause signal distortion if signal level is low and frequency is high. In this paper, we introduce common protection design for EMI and indirect lightning effect, and consideration for minimize signal distortion caused by protection circuit for RS-170a. In addition, we show some example of improvements to the actual equipment design using consideration discussed in this paper.

Analysis of Hydraulic Characteristics by Sediment Protection Weir on Natural River Estuary (자연하도 하구부의 방사보에 의한 수리학적특성 해석)

  • Ahn, Seung-Seop;Choi, Yun-Young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.1
    • /
    • pp.51-60
    • /
    • 2001
  • This study examines the effects of removal of the sediment protection weir at Taehwa river mouth on hydraulic and around river environment considering the fact that the effects of the sediment protection weir which is installed to protect water level drop of Ulsan harbor caused by sediments according to flood in Taehwa river, Dong-chun, and so forth may add water quality contamination by flow stagnance in normal and drought period and accumulation of pollutants. The result is as follows. First, it is estimated from the examination of variation characteristics water depth and level for Taehwa river before and after removal of the sediment protection weir that about 0.01m of water depth down according to removal of the sediment protection weir occurs when low flow runs between the sediment protection weir which is located about 2.3km away from the estuary and Samho-gyo which is about 9.0km away from the sediment protection weir, and about 0.01~0.56m(directly upstream point of the sediment protection weir 0.56m, Myongchon-gyo 0.14m, Ulsan-gyo 0.03m, and Taehwa-gyo 0.02m) downs when design flood flows between the sediment protection weir and the upstream of Taehwa-gyo which is 10km away from the sediment protection weir. Therefore, it is thought that variation of hydraulic characteristics of water depth down and so on according to removal of the sediment protection weir is slight because water depth variation is only about 1cm between directly upstream point of the sediment protection weir and Samho-gyo. Next, it is estimated from the examination of variation characteristics of flow velocity for Taehwa river before and after removal of the sediment protection weir that about 0.0lm/s of flow velocity increase occurs between the directly upstream point of the sediment protection weir which is about 2.4km away from the estuary and the directly upstream point of Samho-gyo when low flow runs, and about 0.01~0.44m/s increases between the sediment protection weir and Samho-gyo when design flood flows. Therefore, riverbed erosion by the increased flow velocity is concerned but it is thought that the concern about riverbed erosion is not great because the mean velocity is about 0.07~1.36m/s when low flow runs, and about 1.02~2.41m/s when design flood flows for the sector which experiences the flow velocity variation.

  • PDF

Reliability Analysis of CMOS Circuits on Electorstatic Discharge (CMOS 회로의 ESD에대한 신뢰성 문제 및 보호대책)

  • 홍성모;원태영
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.12
    • /
    • pp.88-97
    • /
    • 1993
  • Electrostatic Discharge(ESD) is one of the major reliability, issues for today's VLSI production. Since the gate oxide with a thickness of 100~300$\AA$ is vulnerable to several thousand volt of ESD surge, it is necessary to control the ESD events and design an efficient protection circuit. In this paper, physical mechanism of the catastrophic ESD damage is investigated by transient analysis based upon Human Body Model(HBM). Using two-dimensional electrothermal simulator, we study the failure mechanism of the output protection devices by ESD and discuss the design issues for the optimun protection network.

  • PDF

Fire & Life Safety Challenges in Sustainable Tall Building Design

  • Li, Fang;Reiss, Martin
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • The movement towards sustainable building design can result in unique fire protection challenges and concerns, especially with super tall buildings in relationship to traditional prescriptive code compliance. Different countries haves different code requirements as well as local best practices and may cause conflict with the design features when designing green buildings. These include, but not limited to green roofs, sprinkler water quality and testing, fire department access and areas of refuge with direct or indirect impact by the perspective code compliance. The solutions to these prescriptive code challenges and fire safety concerns can range from simple alternatives to more detailed engineering performance-based design analyses with good solid practice.

Safety Assessment for the Design of Digital Reactor Protection System of Nuclear Power Plant (원자력 발전소 디지털 원자로 보호시스템의 설계에 대한 안전성 평가)

  • Kong, Myung-Bock;Lee, Sang-Yong
    • IE interfaces
    • /
    • v.23 no.1
    • /
    • pp.68-77
    • /
    • 2010
  • Digital reactor protection system which consists of many identical modules, is fault- tolerant to provide high safety. The modules themselves including DSP(digital signal processing) card are also fault-tolerant in nature. This paper assesses the safety for being-designed digital reactor protection system of 2-out-of-4 G structure with lockout. Some interesting design alternatives are compared. Fault tree analysis for assessing system safety is performed by Relex software. The selected reactor protection system fully satisfies EPRIURD stipulation of mean failure time of 50 years.