• Title/Summary/Keyword: protection layer

Search Result 527, Processing Time 0.028 seconds

An Enhanced UBR+(EUBR+) scheme to improve the performance of TCP-over-ATM

  • Kim, Chul;Kim, Young-Tak
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.9A
    • /
    • pp.1535-1541
    • /
    • 2001
  • TCP is the most widely-used transport layer protocol in current Internet, while ATM technology is used to increase the data communication speed at data link layer and network layer. In the TCP-over-ATM architecture, the most significant problems are (i) the partial packet discarding problem, and (ii) the TCP window timeout problem. Several approaches have been proposed to solve the partial packet discard problem and the timeout problem individually, but none of them considered the two problems together. In this paper, we propose an enhanced UBR+ scheme which supports fairness among the TCP connections using UBR+ scheme, and provides protection of damaged VC from the multiple packet losses in the same TCP sliding window. To analyze its performance, we simulate the proposed scheme using OPNET. The simulation results show that the proposed scheme supports fairness, and also increases the throughput by reducing the probability of multiple cell losses in the same TCP window.

  • PDF

Efficient isolation, culture and regeneration of Lotus corniculatus protoplasts

  • Raikar, S.V.;Braun, R.H.;Bryant, C.;Conner, A.J.;Christey, M.C.
    • Plant Biotechnology Reports
    • /
    • v.2 no.3
    • /
    • pp.171-177
    • /
    • 2008
  • This paper reports an improved protocol for isolation, culture and regeneration of Lotus corniculatus protoplasts. A range of parameters which influence the isolation of L. corniculatus protoplasts were investigated, i.e., enzyme combination, tissue type, incubation period and osmolarity level. Of three enzyme combinations tested, the highest yield of viable protoplasts was achieved with the combination of 2% Cellulase Onozuka RS, 1% Macerozyme R-10, 0.5% Driselase and 0.2% Pectolyase. The use of etiolated cotyledon tissue as a source for protoplast isolation proved vital in obtaining substantially higher protoplast yields than previously reported. Culture of the protoplasts on a nitrocellulose membrane with a Lolium perenne feeder-layer on the sequential series of PEL medium was highly successful in the formation of microcolonies with plating efficiencies 3-10 times greater than previous studies. Shoot regeneration and intact plants were achieved from 46% of protoplast-derived cell colonies.

Development of Traffic Centralized Control System Based on Protocol Redirection for DB Protection (DB 보호를 위한 Protocol Redirection기반 트래픽 중앙통제시스템 개발)

  • Su, Yang-Jin;Lee, Jae-Pil;Park, Cheon-O;Lee, Deok-Gyu;Chang, Hang-Bae
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.8
    • /
    • pp.1212-1220
    • /
    • 2010
  • The technologies of domestic user programs are not enough to convert address convert information, which was collected via port redirection server, to user traffic. Generally traffic redirection technology is a special purpose technology for I/O traffic via network device. L4 switch needs various additional costs and devices to achieve this special purpose. To solve this problem, there appears need for a central management of control and monitoring by centralizing traffic at one position regardless of network structure and it is necessary to realize redirection function of switch at network layer. Therefore this study offer development of traffic central control system through protocol redirection of client-side.

Discharge Properties of $Al_2O_3$/MgO as a Dielectric Protection Layer ($Al_2O_3$/MgO 유전체 보호막의 방전특성)

  • Jeoung, Jin-Man;Shin, Kyung;Lee, Young-Jong;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.307-310
    • /
    • 1998
  • In this paper, $Al_2$O$_3$/MgO belayer was prepared with Electron-beam evaporation and the properties of the film was investigated in order to improve the property of MgO film, which is used for the protection layer in PDP(Plasma Display Panel). $Al_2$O$_3$/MgO belayer were improved of roughness and it were condensed by annealing, and the result of XPS analysis for $Al_2$O$_3$/MgO belayer unchanged binding energy. To investigate electric characteristics, discharge properties of $Al_2$O$_3$/MgO belayer were compared with discharge minimum voltage for MgO monolayer through Ar discharge experiments.

  • PDF

Seepage Flow Model for Analysis of the Flow Field within the Beach (해빈내의 흐름장 해석을 위한 침투류 모형)

  • 김규한;박창근;한상대;편종근
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.9 no.3
    • /
    • pp.125-131
    • /
    • 1997
  • In order to analyze the feasibility of the drain layer construction method, which is one of the beach protection methods, a hybrid model is constructed by combining the wave model and the seepage flow model. The used wave model is the analytic solution given by Shuto (1972). and the seepage flow model is used by Richards equation which governs the saturated-unsaturated flow in the porous media. It is concluded by the sensitivity analysis of the hybrid model that the most sensitive parameter in the flow field within the beach is the saturated hydraulic conductivity. The developed hybrid model will be efficiently used in the analysis of the parameter when the drain layers are constructed in the beach, if the field datas are obtained more.

  • PDF

A STUDY FOR DOSE DISTRIBUTION IN SPENT FUEL STORAGE POOL INDUCED BY NEUTRON AND GAMMA-RAY EMITTED IN SPENT FUELS

  • Sohn, Hee-Dong;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.174-182
    • /
    • 2011
  • With the reactor operation conditions - 4.3 wt% $^{235}U$ initial enrichment, burn-up 55,000 MWd/MTU, average power 34 MW/MTU for three periods burned time for 539.2 days per period and cooling time for 100 hours after shut down, to set up the condition to determine the minimum height (depth) of spent fuel storage pool to shut off the radiation out of the spent fuel storage pool and to store spent fuels safely, the dose rate on the specific position directed to the surface of spent fuel storage pool induced by the neutron and gamma-ray from spent fuels are evaluated. The length of spent fuel is 381 cm, and as the result of evaluation on each position from the top of spent fuel to the surface of spent fuel storage pool, it is difficult for neutrons from spent fuels to pass through the water layer of maximum 219 cm (600 cm from the floor of spent fuel storage pool) and 419 cm (800 cm from the floor of spent fuel storage pool) for gamma-ray. Therefore, neutron and gamma-ray from spent fuels can pass through below 419 cm (800 cm from the floor) water layer directed to the surface of spent fuel storage pool.

A Study of Shielding Properties of X-ray and Gamma in Barium Compounds

  • Seenappa, L.;Manjunatha, H.C.;Chandrika, B.M.;Chikka, Hanumantharayappa
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.26-32
    • /
    • 2017
  • Background: Ionizing radiation is known to be harmful to human health. The shielding of ionizing radiation depends on the attenuation which can be achieved by three main rules, i.e. time, distance and absorbing material. Materials and Methods: The mass attenuation coefficient, linear attenuation coefficient, Half Value Layer (HVL) and Tenth Value Layer (TVL) of X-rays (32 keV, 74 keV) and gamma rays (662 keV) are measured in Barium compounds. Results and Discussion: The measured values agree well with the theory. The effective atomic numbers ($Z_{eff}$) and electron density (Ne) of Barium compounds have been computed in the wide energy region 1 keV to 100 GeV using an accurate database of photon-interaction cross sections and the WinXCom program. Conclusion: The mass attenuation coefficient and linear attenuation coefficient for $BaCO_3$ is higher than the $BaCl_2$, $Ba(No_3)_2$ and BaSO4. HVL, TVL and mean free path are lower for $BaCO_3$ than the $BaCl_2$, $Ba(No_3)_2$ and $BaSO_4$. Among the studied barium compounds, $BaCO_3$ is best material for x-ray and gamma shielding.

Improvement of ESD Protection Performance of High Voltage Operating EDNMOS Device with Double Polarity Source (DPS) Structure (DPS(Double Polarity Source) 구조를 갖는 고전압 동작용 EDNMOS 소자의 정전기 보호 성능 개선)

  • Seo, Yong-Jin;Yang, Jun-Won
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.12-17
    • /
    • 2014
  • In this paper, modified EDNMOS device with DPS (double polarity source) structure are suggested to realize stable and robust ESD (electrostatic discharge) protection performance of high voltage operating microchip. This DPS structure inserts the P+ diffusion layer on N+ source side, which in intended to block lateral extension of the electron rich region from N+ source side. Based on our simulation results, the inserted P+ diffusion layer effectively prevents the formation of deep electron channeling induced by high electron injection. As a result, our proposed DPS_EDNMOS devices could overcome the double snapback effect of conventional Std_EDNMOS device.

Properties analysis of environment friendly calcareous deposit films electrodeposited at various temperature conditions in natural seawater (천연해수 중 온도 변화에 따라 전착한 환경친화적인 석회질 피막의 특성 분석)

  • Lee, Chan-Sik;Kang, Jun;Lee, Myeong-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.779-785
    • /
    • 2015
  • Cathodic protection is recognized as the most cost-effective and technically appropriate corrosion prevention method for the submerged zone of offshore structures, ships, and deep-sea facilities. When cathodic protection is applied, the cathodic currents cause dissolved oxygen reduction, generating hydroxyl ions near the polarized surface that increase the interfacial pH and result in enhanced carbonate ion concentration and precipitation of an inorganic layer whose principal component is calcium carbonate. Depending on the potential, magnesium hydroxide can also precipitate. This mixed deposit is generally called "calcareous deposit." This layer functions as a barrier against the corrosive environment, leading to a decrease in current demand. Hence, the importance of calcareous deposits for the effective, efficient operation of marine cathodic protection systems is recognized by engineers and scientists concerned with cathodic protection in submerged marine environments. Calcareous deposit formation on a marine structure depends on the potential, current, pH, temperature, pressure, sea-water chemistry, flow, and time; deposit quality is significantly influenced by these factors. This study determines how calcareous deposits form in sea water, and assesses the interrelationship of formation conditions (such as the sea water temperature and surface condition of steel), deposited structure, and properties and the effectiveness of the cathodic protection.

K-means clustering analysis and differential protection policy according to 3D NAND flash memory error rate to improve SSD reliability

  • Son, Seung-Woo;Kim, Jae-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.11
    • /
    • pp.1-9
    • /
    • 2021
  • 3D-NAND flash memory provides high capacity per unit area by stacking 2D-NAND cells having a planar structure. However, due to the nature of the lamination process, there is a problem that the frequency of error occurrence may vary depending on each layer or physical cell location. This phenomenon becomes more pronounced as the number of write/erase(P/E) operations of the flash memory increases. Most flash-based storage devices such as SSDs use ECC for error correction. Since this method provides a fixed strength of data protection for all flash memory pages, it has limitations in 3D NAND flash memory, where the error rate varies depending on the physical location. Therefore, in this paper, pages and layers with different error rates are classified into clusters through the K-means machine learning algorithm, and differentiated data protection strength is applied to each cluster. We classify pages and layers based on the number of errors measured after endurance test, where the error rate varies significantly for each page and layer, and add parity data to stripes for areas vulnerable to errors to provides differentiate data protection strength. We show the possibility that this differentiated data protection policy can contribute to the improvement of reliability and lifespan of 3D NAND flash memory compared to the protection techniques using RAID-like or ECC alone.