• Title/Summary/Keyword: protected zone

Search Result 130, Processing Time 0.038 seconds

The "National Park Concept-Waste-Conservation" Model for the Environmental Education ("국립공원의 개념-훼손-보존" 모형의 환경교육적 접근)

  • 이민부;한주엽
    • Hwankyungkyoyuk
    • /
    • v.8 no.1
    • /
    • pp.151-165
    • /
    • 1995
  • 1. This paper suggests one educational model of National Parks. The model includes main themes such as (1) concepts, (2) waste types, and (3) conservation policies of National Parks for the application at the school environmental education classes. 2. The study describes the origin of the national park system and concepts or policies for the conservation of the parks with cases of Japan, Taiwan, Canada, Australia, Swiss, Russia, and International Union for the Conservation of Nature and Natural Resources(IUCN). The main focuses of their concepts or policies are on the (1) public land, (2) conserved, (3) legally protected land, and (4) land for the education of the loving their country. 3. This research classifies wastes of parks as point, linear, areal, and cubic types, and explains wasting actions on each types, focused mainly on the mountainous national parks. 4. The suggested policies for the conserving national parks, in this paper, are (1) core-zoning policy, and (2) management policy within the core zone. 5. Some principles are suggested for the more effective realization of the policies: (1) enforcement, (2) abandonment,(3) restoration, (4) enlargement, (5) limitation, (6) incorporation, (7) monitoring, and (8) education. 6. Finally, the educational values of this model may be derived from concepts of (1) loving national land, (2) conservation of nature, (3) public responsibility for protection, and (4) education materials. Those concepts form the foundation of models for (1) civic education, (2) education of country, and (3) inquiry training.

  • PDF

A Study on the Fault Detection and Discrimination of Transmission Line using Fault-generated High Frequency Signals (고주파를 이용한 송전선로의 사고 검출 및 판별에 관한 연구)

  • Lee, Dong-Jun;Kim, Chul-Hwan;Kim, Il-Dong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.8
    • /
    • pp.924-931
    • /
    • 1999
  • Most conventional protection relays are based on processing information in the spectrum that is close to or at power frequency. It is, however, widely known that faults on transmission lines produce frequency components of a wide range. High frequency signals caused by sudden changes in system voltage that occurs in the immediate post-fault period are generally outside the bandwidth of receptibility of most protection scheme. In this respect, a specially designed stack tuner is connected to the coupling capacitor of CVT, in order to capture the high frequency signals. Digital signal processing is then applied to the captured information to determine whether the fault is inside or outside the protected zone, and to discriminate the fault type. In this paper, modal transform is not applied to fault generated signals, because signals which are converted by modal transform are not have an information of each phase any longer. Instead, using peak voltage value of data windows is able to discriminate fault type. The paper concludes by presenting fault detection and discrimination of various faults on transmission line which are based on extensive simulation studies carried out on a typical 154kV Korean transmission line, using the EMTP software.

  • PDF

A Study of Issuance of Medical Records Using AMOS (구조 방정식을 활용한 의무기록 사본 발급 특성에 관한 연구)

  • Ahn, Sang-Yoon;Kim, Kwang-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.787-793
    • /
    • 2008
  • This paper investigates the issuance of medical records of patients and caregivers who have obtained medical records from the Medical Record Information Center of "a university" in Daejeon from January through March in 2006. According to the structural equation, "the time zone for issuance of medical records" was -0.01 as a path coefficient against "how medical records are issued" and +0.86 against "ordinary characteristics." As shown above, privacy and confidentiality are what really matters in the management of medical records. Therefore, they must be protected regardless of whether the medical records are hard or electronic copies.

Protection Design and Lightning Zone Analysis for Unmanned Aerial Vehicle with Composite Wings (복합재 주익 무인항공기의 낙뢰보호 설계와 피격영역 해석)

  • Hee-chae Woo;Yong-Tae Kim
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.302-312
    • /
    • 2023
  • This paper describes the analysis of lightning strike zoning, the indirect lightning data simulation and the protection design for lightning indirect effects of equipment by lightning strike for unmanned aircraft consisting of composite wings. Through the analysis of lightning strike zoning according to the external shape of unmanned aerial vehicles, the structure areas that should be protected during lightning strike is derived, and the protection requirements of lightning indirect effects for flight critical equipments and equipment that must be operated upon lightning strike was derived. Lightning protection levels according to the location of mounting equipment and surrounding structure materials for each equipment was derived, and the protection design of the unmanned aerial vehicle with composite structures was also proposed from direct effect of lightning. Later, the lightning protection technology will be verified by the ground test of lightning direct and indirect effects.

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Fish Fauna and Community Analysis in Heuck Stream Watershed (흑천수계의 어류상 및 군집분석)

  • Moon, Woon-Ki;Han, Jeong-Ho;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.1
    • /
    • pp.69-81
    • /
    • 2010
  • This study was conducted at 25 sites of 6 mainstreams and 19 tributaries sites within Heuck Stream watershed during May~October 2003 for the survey of fish distributions, compositions, and community characteristics. The survey showed that total fish was identified as 9 family and 26 species in all sites, and Cyprinidae dominated the community as 15 species. The dominant species of >20% of the total were Zacco temminckii (29%), Zacco platypus (22%), and Rhynchocypris oxycephalus (21%) in the watershed. Community analysis, based on the stream spatial gradients, indicated composition differences along the main axis of the stream from the headwater to the downstream; R. oxycephalus predominated in the most headwater zone and Z. temminckii dominated in the lower headwater zone, whereas Z. temminckii -Z. platypus dominated in the mid-to-downstream, and Z. platypus dominated the community in the most downstream zone. Total endemic species was 7 family and 15 species, which is made of 50% in the fish community, so that the high proportion of endemic species indicated a healthy region in terms of fish community, compared to average 23% in Korean peninsula in general. The total number and species of fish increased as the stream order (stream size) increased, indicating that impacts on chemical pollution or habitat disturbance were not so large to the fish community in this watershed. Trophic and tolerance guilds analysis showed that relative proportions of sensitive and insectivore species were >50% in the watershed and decreased as the stream order increased, whereas relative proportions of tolerant and omnivore species showed an opposite results. These outcomes suggest that the natural condition of watershed is preserved relatively and the region should be protected from the chemical and habitat disturbace by agricultural activity and urban developments.

Effect of Root Zone Cooling Using the Air Duct on Temperatures and Growth of Paprika During Hot Temperature Period (공기순환 덕트를 이용한 근권부 냉방이 고온기 파프리카 재배에서 온도와 생육에 미치는 영향)

  • Choi, Ki Young;Jang, Eun Ji;Rhee, Han Cheol;Yeo, Kyung-Hwan;Choi, Eun Young;Kim, Il Seop;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.243-251
    • /
    • 2015
  • This study aimed to determine the effects of root zone cooling using air duct on air temperature distribution and root zone and leaf temperatures of sweet pepper (Capsicum annum L. 'Veyron') grown on coir substrate hydroponic system in a greenhouse. When the air duct was laid at the passage adjacent the slab, the direction of air blowing was upstream at $45^{\circ}$. The cooling temperature was set at $20^{\circ}C$ for day and $18^{\circ}C$ for night. For cooing timing treatments, the cooling air was applied at all day (All-day), only night time (5 p.m. to 1 a.m.; Night), or no cooling (Control). The air temperature inside the greenhouse at a height of 40 and 80cm above the floor, and substrate and leaf temperatures, fruit characteristics, and fruit ratio were measured. Under the All-day treatment, the air temperature was decreased about $4.4{\sim}5.1^{\circ}C$ at the height of 40cm and $2.1{\sim}3.1^{\circ}C$ at the height of 80cm. Under the Night treatment, the air temperature was decreased about $3.4{\sim}3.8^{\circ}C$ at the height of 40cm and $2.2{\sim}2.7^{\circ}C$ at the height of 80cm. The daily average temperature in the substrate was in the order of the Control ($27.7^{\circ}C$) > Night ($24.1^{\circ}C$) > All-day ($22.8^{\circ}C$) treatment. Cooling the passage with either upstream blowing at $45^{\circ}$ or horizontal blowing at $180^{\circ}$ was effective in lowering the air temperature at a height of 50cm; however, no difference at a height of 100cm. Cooling the passage with perpendicular direction at $90^{\circ}$ was effective in lowering the air temperature at the height between 100 and 200cm above the floor; however, no effect on the temperature at the height of 50cm. A greater decrease in leaf temperature was found at 7 p.m. than that at 9. a.m. under both All-day and Night treatments. Fresh weight partitioning of fruit was in the order of the All-day (48.6%) > Night (45.6%) > Control (24.4%) treatment. A higher fruit production was observed under the All-day treatment, in which the accumulated average temperature was the lowest, and it may have been led to a higher proportion of photosynthate distributed to fruit than other treatments.

A Study on the Identifying OECMs in Korea for Achieving the Kunming-Montreal Global Biodiversity Framework - Focusing on the Concept and Experts' Perception - (쿤밍-몬트리올 글로벌 생물다양성 보전목표 성취를 위한 우리나라 OECM 발굴방향 연구 - 개념 고찰 및 전문가 인식을 중심으로 -)

  • Hag-Young Heo;Sun-Joo Park
    • Korean Journal of Environment and Ecology
    • /
    • v.37 no.4
    • /
    • pp.302-314
    • /
    • 2023
  • This study aims to explore the direction for Korea's effective response to Target 3 (30by30), which can be said to be the core of the Kunming-Montreal Global Biodiversity Framework (K-M GBF) of the Convention on Biological Diversity (CBD), to find the direction of systematic OECM (Other Effective area-based Conservation Measures) discovery at the national level through a survey of global conceptual review and expert perception of OECM. This study examined ① the use of Korean terms related to OECM, ② derivation of determining criteria reflecting global standards, ③ deriving types of potential OECM candidates in Korea, and ④ considerations for OECM identification and reporting to explore the direction for identifying systematic, national-level OECM that complies with global standards and reflects the Korean context. First, there was consensus for using Korean terminology that reflects the concept of OECM rather than simple translations, and it was determined that "nature coexistence area" was the most preferred term (12 people) and had the same context as CBD 2050 Vision of "a world of living in harmony with nature." This study suggests utilizing four criteria (1. No protected areas, 2. Geographic boundaries, 3. Governance/management, and 4. Biodiversity value) that reflect OECM's core characteristics in the first-stage selection process, carrying out the consensus-building process (stage 2) with the relevant agencies, and adding two criteria (3-1 Effectiveness and sustainability of governance and management and 4-1 Long-term conservation) and performing the in-depth diagnosis in stage 3 (full assessment for reporting). The 28 types examined in this study were generally compatible with OECMs (4.45-6.21/7 points, mean 5.24). In particular, the "Conservation Properties (6.21 points)" and "Conservation Agreements (6.07 points)", which are controlled by National Nature Trust, are shown to be the most in line with the OECM concept. They were followed by "Buffer zone of World Natural Heritage (5.77 points)", "Temple Forest (5.73 points)", "Green-belt (Restricted development zones, 5.63 points)", "DMZ (5.60 points)", and "Buffer zone of biosphere reserve (5.50 point)" to have high potential. In the case of "Uninhabited Islands under Absolute Conservation", the response that they conformed to the protected areas (5.83/7 points) was higher than the OECM compatibility (5.52/7 points), it is determined that in the future, it would be preferable to promote the listing of absolute unprotected islands in the Korea Database on Protected Areas (KDPA) along with their surrounding waters (1 km). Based on the results of a global OECM standard review and expert perception survey, 10 items were suggested as considerations when identifying OECM in the Korean context. In the future, continuous research is needed to identify the potential OECMs through site-level assessment regarding these considerations and establish an effective in-situ conservation system at the national level by linking existing protected area systems and identified OECMs.

Effects of Local Cooling and Root Pruning on Budding and Local Heating on Heating Energy Consumption in Forcing Cultivation of Strawberry (딸기 촉성재배 시 국소 냉방 및 단근처리와 국소난방이 화방출뢰와 난방에너지소비에 미치는 영향)

  • Kwon, Jin Kyung;Kang, Suk Won;Paek, Yee;Moon, Jong Pil;Jang, Jae Kyung;Oh, Sung Sik
    • Journal of Bio-Environment Control
    • /
    • v.28 no.1
    • /
    • pp.46-54
    • /
    • 2019
  • Experiments of local cooling and heating on crown and root zone of forcing cultivation of strawberry 'Seolhyang' using heat pump and root pruning before planting were conducted. During the daytime, the crown surface temperature of the crown local cooling treatment was maintained at $18{\sim}22^{\circ}C$. This is suitable for flower differentiation, while those of control and root zone local cooling treatment were above $30^{\circ}C$. Budding rate of first flower clusters and initial yields were in the order of crown local cooling, root zone local cooling and control in root pruning plantlet and non pruning plantlet, except for purchase plantlet. Those of root pruning plantlet were higher than those of non pruning plantlet. These trends were evident in the yield of the first flower cluster until February 14, 2018, and the effect of local cooling and root pruning decreased from March 9, 2018. The budding rates of the second flower cluster according to the local cooling and root pruning treatments were not noticeable compared to first flower cluster but showed the same tendency as that of first flower cluster. In the heating experiment, root zone local heating(root zone $20^{\circ}C$+inside greenhouse $5^{\circ}C$) and crown local heating(crown $20^{\circ}C$+inside greenhouse $5^{\circ}C$) saved 59% and 65% of heating fuel, respectively, compared to control(inside greenhouse $9^{\circ}C$). Considering the electric power consumption according to the heat pump operation, the heating costs were reduced by 55% and 61%, respectively.

Energy Saving Effect for High Bed Strawberry Using a Crown Heating System (고설 딸기 관부 난방시스템의 에너지 절감 효과)

  • Moon, Jong Pil;Park, Seok Ho;Kwon, Jin Kyung;Kang, Youn Koo;Lee, Jae Han;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.420-428
    • /
    • 2019
  • This study is the heating energy saving test of the high-bed strawberry crown heating system. The system consists of electric hot water boiler, thermal storage tank, circulation pump, crown heating pipe(white low density polyethylene, diameter 16mm) and a temperature control panel. For crown heating, the hot water pipe was installed as close as possible to the crown part after planting the seedlings and the pipe position was fixed with a horticultural fixing pin. In the local heating type, hot water at $20{\sim}23^{\circ}C$ is stored in the themal tank by using an electric hot water boiler, and crown spot is partially heated at the setting temperature of $13{\sim}15^{\circ}C$ by turning on/off the circulation pump using a temperature sensor for controlling the hot water circulation pump which was installed at the very close to crown of strawberry. The treatment of test zone consisted of space heating $4^{\circ}C$ + crown heating(treatment 1), space heating $8^{\circ}C$(control), space heating $6^{\circ}C$ + crown heating(treatment 2). And strawberries were planted in the number of 980 for each treatment. The heating energy consumption was compared between November 8, 2017 and March 30, 2018. Accumulated power consumption is converted to integrated kerosene consumption. The converted kerosene consumption is 1,320L(100%) for space $8^{\circ}C$ heating, 928L(70.3%) for space $4^{\circ}C$ + crown heating, 1,161L($88^{\circ}C$) for space $6^{\circ}C$ + crown heating). It was analyzed that space $4^{\circ}C$ + pipe heating and space $6^{\circ}C$ + crown heating save heating energy of 29.7% and 12% respectively compared to $8^{\circ}C$ space heating(control).