• Title/Summary/Keyword: proportional intensity

Search Result 238, Processing Time 0.025 seconds

Semiparametric Bayesian Regression Model for Multiple Event Time Data

  • Kim, Yongdai
    • Journal of the Korean Statistical Society
    • /
    • v.31 no.4
    • /
    • pp.509-518
    • /
    • 2002
  • This paper is concerned with semiparametric Bayesian analysis of the proportional intensity regression model of the Poisson process for multiple event time data. A nonparametric prior distribution is put on the baseline cumulative intensity function and a usual parametric prior distribution is given to the regression parameter. Also we allow heterogeneity among the intensity processes in different subjects by using unobserved random frailty components. Gibbs sampling approach with the Metropolis-Hastings algorithm is used to explore the posterior distributions. Finally, the results are applied to a real data set.

Dependence of Optical Phase Conjugation on Incident Beam Position and Intensity (입사빔의 위치 및 세기에 따른 자기펌핑 위상공액파의 특성)

  • 손동환;전병욱;이임걸;손정영;임동건
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.3
    • /
    • pp.43-51
    • /
    • 1993
  • Effects of incident beam position and intensity on self-pumped optical phase conjugation are presented using barium titanate as an optical phase conjugator. Depending on the position of incident beam, the crystal used consists of four major operating regions: irregular pulsing, regular pulsing, stable phase conjugation, and unstable oscillating regions. In the second region, the pulsing frequency and amplitude of phase conjugate beam are proportional to I$_{in}$ and I$_{in}^{0.85}$, respectively, where I$_{in}$ is the incident beam intensity. In the fouth region, the rising time and intensity of the first-generated pulse are proportional to I$_{in}^{0.92}$ and I$_{in}^{0.81}$, respectively. A frequency shift by beam fanning is also discussed by observing interference pattern from an interferometer.

  • PDF

The Dependency of CH* Chemiluminescence of a Laminar Premixed Flame on Fuel Types (연료에 따른 층류 예혼합화염의 CH* Chemiluminescence 신호특성 변화)

  • Lee, Won-Nam;Kang, Suk-Min
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.2
    • /
    • pp.14-22
    • /
    • 2008
  • The CH* chemiluminescence of premixed flames and their dependency on fuel types has been experimentally investigated on laminar methane and propane premixed flames. The measured chemiluminescence intensities are observed linearly proportional to the fuel flow rate, which could be interpreted as the CH* chemiluminescence signal is linearly proportional to the heat release rate under fuel lean conditions. The effect of equivalence ratio could be expressed by an exponential function as ${I_{CH*}}^{\propto}\;a_1\;{\exp}(b_1{\Phi})$, where $a_1\;=\;0.00054$ and $b_1\;=\;4.60$ for methane and $a_1\;=\;0.0056$ and $b_1\;=\;5.02$ for propane. Oscillating flames showed the temporal fluctuation of chemiluminescence intensity: however, the time averaged values are virtually identical to those of quiescent flames under the same fuel flow rate and equivalence ratio conditions. This observation suggests that there is no significant flame stretch effect on chemiluminescence intensity, in average values.

  • PDF

Development of Photo-sensor for Integrated Lab-On-a-Chip (집적화된 Lab-On-a Chip을 위한 광센서의 제작 및 특성 평가)

  • 김주환;신경식;김용국;김태송;김상식;주병권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.4
    • /
    • pp.404-409
    • /
    • 2004
  • We fabricated photo-sensor for fluorescence detection in LOC. LOC is high throughput screening system. Our LOC screens biochemical reaction of protein using the immunoassay, and converts biochemical reaction into electrical signal using LIF(Laser Induced Fluorescence) detection method. Protein is labeled with rhodamine intercalating dye and finger PIN photodiode is used as photo-sensor We measured fluorescence emission of rhodamine dye and analyzed tendency of fluorescence detection, according to photo-sensor size, light intensity, and rhodamine concentration. Detection current was almost linearly proportional to two parameters, intensity and concentration, and was inversely proportional to photo-sensor size. Integrated LOC consists of optical-filter deposited photo-sensor and PDMS microchannel detected 50 (pg/${mu}ell$) rhodamine. For integrated LOC including light source, we used green LED as the light source and measured emitted fluorescence.

A study on the influence of turbulence characteristics on flame propagation in swirl flow field (스월유동장의 화염전파에 미치는 난류특성의 영향에 관한 연구)

  • Lee, Sang-Jun;Lee, Jong-Tae;Lee, Seong-Yeol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3282-3292
    • /
    • 1996
  • Flow velocity was measured using a hot wire anemometer. Turbulence intensity was in proportion to mean flow velocity regardless of swirl velocity. And integral length scale has proportional relation with swirl velocity regardless of measurement position. Flame speed calculated by radius of visualized flame was increased and then decreased according to lapse of time from spark. Maximum flame speed was increased according to increase of turbulence intensity. Burning speed and flame transport effect increased with increase of swirl velocity, but ratio of burning speed to flame speed decreased with increased of swirl velocity. Mass fraction burned versus volume fraction burned was increased in proportion to the increase of turbulence intensity, caused by increase of combustion promotion effect according to increase of turbulence intensity and scale.

Estimating Repair Effect and Parameters of Intensity Function under BMS Repair Model (BMS 수리모형하에서 시스템의 수리효과 및 고장강도함수의 모수추정)

  • 윤원영;정석주;정일한;김종운;정상욱
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.25 no.4
    • /
    • pp.45-54
    • /
    • 2000
  • Estimation Problems of parameters of the failure process and the repair effect in repairable systems are considered. We propose estimation procedures in repairable systems without preventive maintenances. The failure process is modeled by a proportional age reduction model (Brown, Mahoney, Sivazlian [5]) which is able to consider both aging and repair effects. Maximum likelihood method is used to estimate the repair effect and parameters of intensity function simultaneously. simulations are performed to evaluate the accuracy of estimators. A numerical example is also presented.

  • PDF

THE $^{13}CO$ DISTRIBUTION AND CORRELATION WITH EXTINCTION IN L134

  • MINN YOUNG KEY;LEE HYE KYUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.1
    • /
    • pp.75-81
    • /
    • 1996
  • We mapped the $^{13}CO$ line in the dark nebula L134 using the 14-m Taeduck radio telescope with a 57 arcsec beam and one beam spacing. The cloud has a spherical shape with an intensity peak ridge extended from the northwest to the southeast directions. The halfwidth and the radial velocity of the lines peak at the region of the cloud center. The radial velocity decreases from the cloud center towards the north and south directions. The integrated line intensity distributions in the space-velocity plane show some structure and a velocity gradient. The $^{13}CO$ and $H_2CO$ clouds and dark clouds are closely related in space in shape, outer boundary, and intensity peak positions. The $^{13}CO$ integrated line intensity is linearly proportional to the visual extinction.

  • PDF

Effect of Electric Fields on Flame Speed of Propagating Premixed Flames in Tube (전기장이 튜브내 예혼합화염 전파속도에 미치는 영향에 관한 연구)

  • Ryu, S.K.;Won, S.H.;Cha, M.S.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.137-143
    • /
    • 2006
  • The effect of electric fields on flame speed has been investigated experimentally by observing propagating premixed flames in a tube for methane/air mixtures. The flame speeds were measured in both the normal and micro gravity conditions to substantiate the measurements. The results show that the flame speeds were enhanced by both the AC and DC electric fields, as the flame approached to the high voltage electrode located on the one end of the tube. The enhancement of flame speed was proportional to the square root of the electric field intensity, defined as the voltage applied divided by the distance of flame from the high voltage electrode, when the electric field intensity is sufficiently large. When the electric field intensity was low, there existed critical intensities, below which the electric fields did not influence the flame speed. This critical electric field intensity correlated well with the flame speed.

  • PDF

A Study on the Optimized Test Condition of Lock-in IR Thermography by Image Processing

  • Cho, Yong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.3
    • /
    • pp.276-283
    • /
    • 2012
  • In this study, it was studies the utilization of LIT(lock-in infrared thermography) which can detect defects in welded parts of ship and offshore structures. Quantitative analysis was used through methods of filtering and texture measurement of image processing techniques to find the optimized experimental condition. We verified reliability in our methods by applying image processing techniques in order to normalize evaluations of comparative images that show phase difference. In addition, low to mid exposure showed good results whereas high exposure did not provide significant results in regards to intensity of light exposure on surface. Lock-in frequency was satisfactory around 0.1 Hz regardless of intensity of light source we had. In addition, having the integration time of thermography camera inversely proportional to intensity of exposed light source during the experiment allowed good outcome of results.

Developing a Non-Periodic Preventive Maintenance Model Guaranteeing the Minimum Reliability (최소 신뢰도를 보장하는 비 주기적 예방보전 모형 개발)

  • Lee, Juhyun;Ahn, Suneung
    • Journal of Applied Reliability
    • /
    • v.18 no.2
    • /
    • pp.104-113
    • /
    • 2018
  • Purpose: This paper proposes the non-periodic preventive maintenance policy based on the level of cumulative hazard intensity. We aim to construct a cost-effectiveness on the proposed model with relaxing the constraint on reliability. Methods: We use the level of cumulative hazard intensity as a condition variable, instead of reliability. Such a level of cumulative hazard intensity can derive the reliability which decreases as the frequency of preventive maintenance action increases. We also model the imperfect preventive maintenance action using the proportional age setback model. Conclusion: We provide a numerical example to illustrate the proposed model. We also analyze how the parameters of our model affect the optimal preventive maintenance policy. The results show that as long as high reliability is guaranteed, the inefficient preventive maintenance action is performed reducing the system operation time. Moreover, the optimal value of the proposed model is sensitive to changes in preventive maintenance cost and replacement cost.