• Title/Summary/Keyword: profile measurement

Search Result 912, Processing Time 0.03 seconds

Effect of Melt-mixing Conditions on Fracture Properties of Bioabsorbable HA/PLLA Composite Materials (생체흡수성 HA/PLLA 복합재료의 용융혼련조건이 파괴특성에 미치는 영향)

  • Park, Sang-Dae;Lee, Deok-Bo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.7 s.262
    • /
    • pp.732-738
    • /
    • 2007
  • Effects of melt-mixing conditions on fracture properties of hydroxyapatite filled bioabsorbable poly(L-lactic acid)(HA/PLLA) composites was investigated by measuring the firacture toughness value of HA/PLLA composites prepared under different mixing time and rotor speed. The fracture surface morphology was also examined by profile measurement and scanning electron microscopies. It was found that the fracture toughness of HA/PLLA composites decreases due to decrease of ductile deformation of PLLA matrix and debonding of interfaces with increase of the rotor speed and mixing time. Effect of mixing process on neat PLLA was also assessed, and it was found that the fracture toughness of PLLA decreases due to disappearance of multiple craze formation and increase of defects. Such thermal and shear-stress degradation were found to be the primary mechanisms of the degradation of HA/PLLA composites during melt-mixing process.

Analyses and Measurements of Rotational Accuracy for Journal Shaft in a Scroll Compressor (스크롤 압축기 저어널 회전축의 궤적 계산 및 측정)

  • Park, Sang-Shin;Kim, Gyu-Ha;Lee, Jin-Kab
    • Tribology and Lubricants
    • /
    • v.23 no.3
    • /
    • pp.83-88
    • /
    • 2007
  • This paper presents measurement processes of rotational accuracy and comparison of theoretical values in the main bearing of scroll compressor. The main bearing is a type of oil journal bearing, but it has an axial or helical groove. The generalized coordinate system method, which can handle this groove, is applied to calculate the pressure profile in the journal bearing. The orbits of journal shaft are calculated corresponding to the compressed gas forces and bearing reaction forces. Then, the orbits are measured using three-point method. The results are compared to that from analyses.

A Study on the Phase Measuring Profilometry with Parallel-optical-axes (평행 광축에서의 위상측정 형상측정법에 관한 연구)

  • 정경민;박윤창;박경근
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.6
    • /
    • pp.210-217
    • /
    • 2000
  • Noncontact measuring methodology of 3-dimensional profile using CCD camera are very attractive because of it's high measuring speed and it's high sensitivity. Especially when projecting a grid pattern over the object, the captured image have 3 dimensional information of the object. Projection moire extract 3-D information with another grid pattern in front of CCD camera. However phase measuring profilometry(PMP) obtain similar results without additional grid pattern. In this paper, the projection moire are compared with the PMP mathematically, and it is shown that PMP can generate moire image with simple mathematical computations. Experimental works are also carried out showing the same results. It is shown that using a single gird pattern, moire image can be obtained directly without any mathematical operation when some conditions are satisfied.

  • PDF

Artificial blood flow measurement using Ultrasound Time Domain Correlation (Ultrasound Time Domain Correlation을 이용한 가상 혈류 속도 측정)

  • 김의준
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1992.06a
    • /
    • pp.103-106
    • /
    • 1992
  • 기존의 혈류 속도 측정 방법으로는 인체내에 반사 물질을 투입하는 Fick technique과 electromagnetic flowmeter등을 이용한 invasive method와 Ultrasonic Doppler method에 의한 noninvasive method가 이용되고 있다. 이 방법들은 혈과의 모양이나 혈관에서의 flow velocity profile등에 관한 정확한 정보를 얻을 수 없다. 이와같은 문제점들을 해결하기 위한 혈류속도 측정 방법으로 실험실 조건하에서 인체에서와 유사한 혈류측정 장치를 제작하여, vessel의 표본 체적내의 산란체로부터 후방산란되는 초음파 신호의 correlation을 이용한 Ultrasound Time Domain Correlation (UTDC) technique을 연구하였다. UTDC technique을 이용하여 유속을 측정한 결과, 12% 이하의 정밀도로 평균 유체 유속이 측정되었고, Ultrasonic Doppler method에서 측정할 수 없는 혈과의 모양과 혈관의 각 위치에서의 유속 및 혈관벽에 이물질의 존재여부를 명확히 판단할 수 있었다.

  • PDF

Coordinated Voltage-Reactive Power Control Schemes Based on PMU Measurement at Automated Substations

  • Choi, Yun-Hyuk;Kang, Sang-Gyun;Lee, Byongjun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1400-1407
    • /
    • 2015
  • This paper deals with methodology to control an automatic substation system. The control system can predict the power system condition by a voltage stability index (VSI). The strategies in this paper is called as Voltage-Reactive Power Control (VRPC), which regulates an abnormal voltage of a target substation by using coordination between tap changers and shunt capacitor/reactor. This method is efficient for better voltage profile. The monitoring substation includes whole of substations around the contingency event. The control quantities of the monitoring substations are decided by the calculation of the VSI, called as a Z-index. Case studies with BC Hydro-Quebec system are presented to illustrate this approach using real-time simulator.

Fluidic velocity sensing with a speaker based optical doppler tomography (유속 센싱을 위한 스피커형 광학적 유체 단층촬영 기술)

  • Lee, Chang-Ho;Kim, Jee-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.317-324
    • /
    • 2008
  • This paper presents an optical doppler tomography(ODT) system using a speaker as a method to achieve depth measurement in a flowing sample. The use of the speaker provides easy implementation with a low cost. The nonlinear characteristics of the speaker has hindered its adaptation because it produces inconsistent fringe frequencies at different depths. This paper reports an adaptive algorithm to compensate the nonlinear characteristics, and could, resultantly, acquire the Doppler frequency shift caused by the sample. The experiment utilizes a flowing scattering particle solution in a capillary tube at a certain flow rate. The Doppler frequency profile over the lumen was calculated by using spectrogram method. and we obtained the velocity image of the sample.

Crystallite Size Measurement of Uranium Oxide Fuel Powders by Neutron Diffraction (중성자 회절에 의한 산화우라늄 핵연료 분말의 결정크기 측정)

  • 류호진;강권호;문제선;송기찬;최용남
    • Journal of Powder Materials
    • /
    • v.10 no.5
    • /
    • pp.318-324
    • /
    • 2003
  • The nano-scale crystallite sizes of uranium oxide powders in simulated spent fuel were measured by the neutron diffraction line broadening method in order to analyze the sintering behavior of the dry process fuel. The mixed $UO_2$ and fission product powders were dry-milled in an attritor for 30, 60, and 120 min. The diffraction patterns of the powders were obtained by using the high resolution powder diffractometer in the HANARO research reactor. Diffraction line broadening due to crystallite size was measured using various techniques such as the Stokes' deconvolution, profile fitting methods using Cauchy function, Gaussian function, and Voigt function, and the Warren-Averbach method. The non-uniform strain, stacking fault and twin probability were measured using the information from the diffraction pattern. The realistic crystallite size could be obtained after separation of the contribution from the non-uniform strain, stacking fault and twin.

Measurement of Time response of Calcium Ion in MG-63 Cells Induced by Shear Stress (전단응력에 의한 골육종 세포의 칼슘이온 시응답 특성 측정)

  • Park, So-Hee;Shin, Jung-Wook;Jeong, Ok-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.183-183
    • /
    • 2008
  • This paper presents the time responses of calcium ($Ca^{2+}$) ion concentration of MG-63 cells induced by a constant shear stress in micro channel were observed in the real time. Most of cells have similar rising time. There were some time delays because of the initial position of the cell in the micro channel along the pressure-driven fluid flow. The concentration of $Ca^{2+}$ exponentially decreased while time constant of each profile did not have any relation to the peak value of concentration.

  • PDF

Measurement of Volatile Organic Compounds Concentrations in the Air of a Highway Tunnel (고속도로 터널내부 공기 중 휘발성 유기화합물의 농도 측정)

  • 백성옥;김영민;황승만
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.1
    • /
    • pp.73-77
    • /
    • 1998
  • In this study, a total of 10 volatile organic compounds (VOCs) including BTEX were determined in the inside and outside of a highway thnnel in order to evaluate the emission profile of automobile exhaust with respect to the concentrations, relative ratio and correlation coefficient of target analytes. In addition to VOCs, CO $CO_2 and NO_2$ were measured simultaneously. The results of this study indicated that the most abundant compound was toluene followed by benzene and m+p-xylenes, and the correlation coefficients between VOCs except styrene were higher than 0.96. The concentration ratio of toluene, ethylbenzene, xylenes with respect to benzene measured in the inside of tunnel was 1.5, 0.13, 0.74, respectively. Such ratios were found to be very similar to those measured in tunnels in the USA.

  • PDF

A Recursive Restoration Scheme of B-Scan Ultrasonographic Images in Noisy Case (잡음을 고려한 회귀방법에 의한 초음파 진단기의 화상개선)

  • Kim, Sun-I.;Min, Byoung-G.;Ko, Myoung-S.
    • Journal of Biomedical Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.35-42
    • /
    • 1982
  • The objective of this phantom study is to develop a digital method for improving the lateral resolution of B-scan ultrasonographic images irs medical application of ultrasound. By utilizing a discrete state-space modeling approach and Kalman-Buch method for analysis of the transducer's beam profile and the measurement and sampling noise, a stable recursive restoration of the object image was obtained for improved lateral resolution. The point spread function (PSF) was measured for the reflective signals after scanning the small pins located along the depth of interest. One major advantage of the present recursive scheme over the transform method is in its applicability for the space-variant imaging, such as in the case of the rotational movement of transducer.

  • PDF