• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.032 seconds

Hyperthermia Properties of Fe3O4 Nanoparticle Synthesized by Hot-injection Polyol Process (Hot-injection Polyol 공정에 의해 제조된 Fe3O4 나노입자의 Hyperthermia 특성)

  • Lee, Seong Noh;Kouh, Taejoon;Shim, In-Bo;Shim, Hyun Ju
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.2
    • /
    • pp.51-55
    • /
    • 2014
  • The $Fe_3O_4$ nanoparticle was synthesized by the hot-injection method while varying the injection time of the precursor solution. The crystal structure was determined to be cubic inverse spinel with space group of Fd-3m based on X-ray diffraction (XRD) measurements and the morphology of the prepared $Fe_3O_4$ nanoparticle was studied with a high-resolution transmission electron microscope (HR-TEM). When the precursor solution was injected for 0.5 min, the size of the $Fe_3O_4$ nanoparticle was 7.63 nm, while the size of the obtained particle was 21.27 nm with the injection time of 60 min. The magnetic properties of the prepared $Fe_3O_4$ nanoparticle were investigated by both vibrating sample magnetometer (VSM) and $^{57}Co$ M$\ddot{o}$ssbauer spectroscopy at various temperatures. From the hyperthermia measurement, we observed that the temperature of the $Fe_3O_4$ nanoparticle powder reached around $120^{\circ}C$ under 250 Oe at 50 kHz, when the injection time of the precursor solution was 60 min.

An Analysis of Dental Anxiety and Dental Utilization Behavior of College Students (일부 대학생의 치과불안과 치과의료이용 행태)

  • Hwang, Hye-Rim;Lee, Su-Young;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.10 no.5
    • /
    • pp.357-363
    • /
    • 2010
  • The aim of this study was to measure the dental anxiety, the factors associated with dental anxiety and the utilization behavior of dental treatment. Modified dental anxiety scale(MDAS) and Dental fear survey(DFS) were used as measurement, where through the mean and the standard deviation were worked out and also the T-test and ANOVA were performed. In relation to MDAS, females and males showed the mean, '$2.86{\pm}0.06$' and '$2.49{\pm}0.06$' (p=0.000). Also, less than 20 and more than 21 showed the mean, '$2.81{\pm}1.01$' and '$2.61{\pm}0.99$' (p=0.023). In relation to dental utilization behavior, the subjects were classified into three groups, a group who uses dental clinics periodically, a group who uses them only when problems arise, and a group who has not ever used them. MDAS indicated a higher value in the group who use dental clinics only when problems arise, which was significant statistically (p=0.000). In the case of MDAS, many respondents answered that they felt anxious in the process of actual treatment; in the case of DFS, they felt anxious due to the factors that cause irritation.

Analysis of Domestic SNA-based Governance Study Trends (소셜네트워크분석을 통한 국내 거버넌스 연구 동향 분석)

  • Kim, Na-Rang;Choi, Hyung-Rim;Lee, Taihun
    • Journal of Digital Convergence
    • /
    • v.16 no.7
    • /
    • pp.35-45
    • /
    • 2018
  • Research on the establishment of new governance aimed at efficient policy planning and the implementation thereof by the government has been conducted in response to social changes. Nonetheless, governance is comprehensive and encompasses different meanings; it takes various forms in the process of its actual application. Therefore, systematic classification of research on governance and analysis on its research trend are required. Accordingly, three researchers who majored in policy sciences, business informatics, and library and information science, respectively, searched for theses related to governance published since 2016 from Research Information Sharing Service and conducted a social network analysis (SNA) on them. According to their research results, the main research topics were largely classified into collaborative governance and local governance. Keywords throughout the topics included network, participation, conflict, and trust in line with the characteristics of governance. Representative subjects of governance included education, urban regeneration, and the environment. Further, measurement of betweenness centrality showed local governance was a main topic for convergent research. This study will lead to a greater understanding of research on governance and help activate such research. One limitation of this study is that it analyzed only theses with the keywords but not all theses on governance. Follow-up research should analyze all theses on governance and statistically verify them with SNA indexes.

Construction of a Silver(I) Ion-Selective Electrode Using Amine Phenol Ligand as Carrier and the Selective Determination of Silver in Actual Samples (수송체로서 아민페놀을 이용한 은(I)이온-선택 전극의 제조와 실제 샘플에서 은의 선택적 측정)

  • Xu, Wen-Ju;Chai, Ya-Qin;Yuan, Ruo
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.1
    • /
    • pp.63-69
    • /
    • 2011
  • This work discusses the fabrication, development and potential response behaviors of $Ag^+$ ion-selective electrodes ($Ag^+$-ISE) based on N,N'-bis(2-hydroxybenzyl)-1,3-diaminopropane (L1) and N,N'-bis(2-hydroxybenzyl)-2,2-dimethyl-1,3-diaminopropane (L2) as carriers. The observations indicated that the resulting electrode based on L1 toward $Ag^+$ showed stable near-Nernst slope approaching 58.7 mV/dec and the optimum potential response characteristics in a linear range at least five orders of magnitude with a detection limit of $1.0{\times}10^{-6}M$. The proposed electrode displayed the preferential selectivity to $Ag^+$ against other tested cations. The excellent potential analytical characteristics could lead to the successful applications of silver assay in significant real samples, indicating that the proposed $Ag^+$-ISE showed a significant advancement of measurement capabilities. But for the electrode based on L2, the poor potential response characteristics were observed in total experiment process.

Research on Measurement Condition Establishment of a Liquid Scintillation Counter System (액체섬광계수기 장비의 계측조건 확립에 관한 연구)

  • Park, Eung-Seop;Han, Sang-Jun;Lee, Seung-Jin;Kim, Hee-Gang;Lee, Na-Young;Mun, Ji-Yeon
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.155-164
    • /
    • 2006
  • It is judged that there could be certainty in every process of analyzing environmental samples using Liquid Scintillation Counter. Therefore, this study focuses on quantitative evaluation on uncertainty in an effort to analyze comparatively accurately environmental samples. For this, after parameters which can have an effect on uncertainty was derived, the evaluation on each parameter was tamed out. The results of analysis of each parameter showed that the effect according to the weight difference of Teflon vial did not appear, and that standard deviations of SQP(E) averages reached saturation point at $75{\sim}90$ sec at the result of making increases step by step the irradiation time of External standard, and that values measured by repeat method produces good results compared with replicate. Also, conclusion was derived that analysis on sample after it is left in cold and dark room at least above 1,000 minutes have to be carried out, and the result of carrying out verification on results measured as well as equipment itself using radioactivity-error-analysis and chi-square test, resonable result was derived.

Electrical Resistivity at Room Temperature and Relation between Physical Properties of Core Samples from Ulleung Island (울릉도 시추 코어의 상온 전기비저항과 물성 간의 상관성)

  • Lee, Tae Jong;Lee, Sang Kyu;Yun, Kwan-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.4
    • /
    • pp.171-180
    • /
    • 2015
  • Electrical resistivity of 23 core samples from Ulleung Island at dry or saturated condition has been measured along with dry density and effective porosity, and the relations between the properties has also been discussed. Upper and lower bounds of electrical resistivity at room temperature can be provided by the dry- and saturated-resistivity, respectively. Injecting nitrogen gas to the pore space at the very end of drying process can prevent humid air from getting into the pore space, so that measurement of dry-resistivity can be less affected by humidity in the air. Dry density and porosity have very close correlation; the ratio between increase of porosity and the decrease of density showed distinct relation to the rock types, such that basaltic rocks showed higher ratio while trachytic rocks showed lower. Saturated resistivity showed close correlation to density and effective porosity of the rock sample, while dry resistivity didn't.

The Extracts from Natural Product Complex (DW) Suppress Lipid reroxidation and Inhibit Liver Fibrosis (Cirrhosis) in Rats (실험동물에서 복합천연물(DW)의 지질 과산화 억제와 간섬유화 저해 효과 검색)

  • 정재열;임진아;박선영;서의석;제갈승주;김기영
    • YAKHAK HOEJI
    • /
    • v.45 no.5
    • /
    • pp.513-521
    • /
    • 2001
  • The chronic cholestasis induce to biliary liver fibrosis (cirrhosis) and the increased products of ROS(reactive oxygen species) cause to the liver damage. In this study ; the antioxidant and antifibrotic effect of dried extracts of oriental medicine (DW) was investigated under the liver fibrotic (cirrhotic) condition. The female Sprague-Dawley rats were divided in 5 groups (Normal, Op-2, Op-4, OpDW-2, OpDW-4). Except for normal group, the rats were induced to biliary liver fibrosis (cirrhosis) by the operation of bile duct ligation/scission (BDU/S) and were observed in 2 weeks or 4 weeks. And the prepared DW was treated p.o.2 ml/day/rats in 2 weeks or 4 weeks for OpDW groups. At the time of sacrifice, the liver, kidney, spleen were weighed and the ratio of organ weight/body weight was calculated. The MDA, the hyp and biochemical parameters (GOT GTP, ALP, t-bili) were measured in sera and liver tissue of rats. The biochemical change was observed on liver tissue. In the result, the hepatomegaly and spleenomegaly appeared in all BDL/S operated rats, and significantly lower liver weight was observed in OpDW-4 group compared with in Op-4 group (p<0.05). The level of clinical parameters in sera of all liver fibrosis (cirrhosis) developed rats was higher than in normal group. Especial1y, the value of GOT in OpDW-2 group and ALP in OpDW-4 group showed significantly lower than in Op-2 group and Op-4 group (p<0.01, p<0.005). The content of hyp in all operation groups was significantly higher than in normal group (p<0.05∼<0.005), and showed significantly lower value in the OpDW-4 group than in Op-4 group (p<0.05). The product of lipid peroxidationUDA) increased significantly under the fibrotic(cirrhotic) condition (p<0.05∼ <0.005), and the MDA value in OpDW-4 group decreased significantly in Op-4 group (p<0.005). The histological change (bile duct proliferation, fibrosis, collagen bundle) was similarly observed in Op-2 group and in OpDW-2 group, but the weak fibrosis and bile duct proliferation were observed in OpDW-4 group compared with in Op-4 group. In conclusion, lipid peroxidation and severe liver damage were activated by bile duct obstruction, and the measurement of MDA and hap can be useful monitor for the screening of antioxidant and antifibrotic effect in experimental liver fibrosis (cirrhosis). The 4 weeks treatment with DW extracts suppressed lipid peroxidation and inhibited fibrotic (cirrhotic) process in BDL/S operated rats.

  • PDF

Measurement of the Device Properties of a Ionization Smoke Detector to Improve Predictive Performance of the Fire Modeling (화재모델링 예측성능 개선을 위한 이온화식 연기감지기의 장치물성 측정)

  • Kim, Kyung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-34
    • /
    • 2013
  • The high prediction performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of PBD (Performance Based fire safety Design). The main objective of the present study is to measure input information in order to predict the accurate activation time of smoke detector into a Large Eddy Simulation (LES) fire model such as FDS (Fire Dynamics Simulator). To end this, FDE (Fire Detector Evaluator) which can measure the device properties of detector was developed, and the input information of Heskestad and Cleary's models was measured for a ionization smoke detector. In addition, the activation times of smoke detectors predicted using default values into FDS and measured values in the present study were systematically compared. As a result, the device properties of smoke detector examined in the present study showed a significant difference compared to the default values used into FDS, which resulted in the considerable difference of up to 15 minutes or more in terms of the activation time of smoke detector. The database (DB) on device properties of various smoke and heat detectors will be built to improve the reliability of PBD in future studies.

Free-air anomaly from Airborne Gravity Surveying (항공중력측정에 의한 프리에어 이상 산출)

  • Lee, Ji-Sun;Kwon, Jay-Hyoun;Lee, Bo-Mi;Hong, Chang-Ki
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.139-147
    • /
    • 2009
  • The gravity data collected and reserved in Korea is seriously biased in its distribution. That is, only the west-southern part of the peninsula including Chungcheong and Jeonla area has dense distribution while only a part is covered in Gyoungsang area. Especially, the low density of the gravity data in mountainous area basically limits the accuracy of the gravimetric geoid in Korea. As one of the solution to overcome the problem, an airborne gravity survey were conducted from Dec. 2008 $\sim$ Jan. 2009. In this study, free-air gravity anomaly derived from the airborne gravity data which has consistent quality are presented. The data processing for the airborne gravity is composed of several corrections of errors such as errors from gravity measurement, errors from flight dynamics, errors from GPS, and errors from time synchronization. We presented detailed explanations on the data processing with the final cross-over results. The free-air anomaly from airborne gravity finally shows the cross-over accuracy of 2.21mGal which reflects the precision of each track is 1.56mGal. It is expected that the result from this study will play a role as input data in precision geoid determination with ground and ship-borne gravity data after appropriate fusion process.

The effects of aircraft noise on the hearing loss, blood pressure and response to psychological stress (군용 항공기 이륙소음이 청력, 혈압, 스트레스 및 주관적 인지도에 미치는 영향)

  • Han, Sang-Hwan;Cho, Soo-Hun;Koh, Kyung-Shim;Kwon, Ho-Jang;Ha, Mi-Na;Ju, Yeong-Su;Shin, Myung-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.356-368
    • /
    • 1997
  • In effort to determine whether aircraft noise can have health effects such as hearing loss, hypertension and psychological stress, a total of 111 male professors and administrative officers working a college near a military airport in Korea(exposed group) and a total of 168 males and 112 females matched by age groups(control groups) were analyzed. Personal noise exposure and indoor and outdoor sound level of jet aircraft noise were measured at the exposed are3. And pure tone, air conduction test and measurement of blood pressure were given to the exposed(males) and matched control groups (males and females). BEPSI(Brief Encounter Psychological Instrument) and psychological response to aircraft noise were examined for the exposed group. The noise dosimetry results revealed time-weighted averages(TWAs) that ranged from 61 to 68 dBA. However the levels encountered during taking off jet airplanes reached 126 dBA for two half minutes time period. Th, audiometric, test showed that mean values of HTL(hearing threshold level) in exposed group at every frequency(500, 1,000, 2,000, 4,000, and 8,000 Hz were much lower than them of male and female control groups. And in old age groups, interaction of age and noise was observed at 8,000 Hz in both ears(p<0.05). Conclusively, aircraft noise does not appear to induce hearing loss directly in high frequency, but may decreased hearing threshold level by interaction of aging process and noise exposure. However, difference of mean values of exposed and control groups on blood pressure was not significantly. In psychological test, annoyance was the most severe psychological response to noise in exposed group, but mean value of BEPSI was not correlated with job duration in exposed group.

  • PDF