• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.033 seconds

Comparative Study of Mechanical and VOC Properties According to Manufacturing Conditions of Glass Fiber/Bamboo Fiber/PP Composites (유리섬유/대나무섬유/PP 복합재의 제조 조건에 따른 기계적 및 VOC 특성 비교 연구)

  • Lee, Su-kyoung;Park, Tae-sung;An, Seung-kook
    • Textile Coloration and Finishing
    • /
    • v.33 no.3
    • /
    • pp.153-160
    • /
    • 2021
  • In this study, composite materials were prepared by varying the content of glass fiber and bamboo fiber in PP/glass fiber/bamboo fiber. Experiments were conducted to confirm the mechanical properties(tensile, impact and burst strength) and volatile organic compound content of the bamboo fiber composite prepared under these conditions. An improvement in the main properties was observed at a fiber content of 30wt%. When the fiber fraction was increased above 30wt%, the mechanical properties tended to decrease due to the agglomeration of fibers at higher load fractions. In addition, the content of volatile organic compounds increased as the content of bamboo fibers increased, which is thought to be due to the volatile organic compounds generated during the manufacturing process of the composite material being present in the composite material without escaping from the pores of the bamboo fibers and volatilizing at a certain temperature. As a result of confirming the physical properties of the composite, it is considered that the optimal mixing condition is 30wt% of bamboo fiber for the composite produced by varying the amount of bamboo fiber composite. In the future, it is thought that follow-up experiments to confirm and improve the pre-treatment conditions for reducing the content of volatile organic compounds in the manufactured composite material are possible.

A Study on the High Sensitivity Electrical Muscle Stimulation (EMS) Pad Using E-TEXTILE (E-TEXTILE을 이용한 고감성 전기 근육 자극(EMS)패드의 연구)

  • Yeun, Eun-Ji;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.24 no.3
    • /
    • pp.81-90
    • /
    • 2021
  • EMSCT (Electrical Muscle Stimulation Conductive Textile) is an electrical muscle stimulation pad that can compensate for ease of use and comfort, which are disadvantages of conventional hydrogel pads used in electrical muscle stimulation (EMS). With the concentration with SWCNT (Single-Walled Carbon Nanotube) and the number of impregnation processes, EMSCT was tested by giving conductivity to five fabrics (radirons, neoprene, spandex cushions, poly100%, and vergamo). The padding process with SWCNT was performed, and the alternating current measurement indicated that the most similar alternating current with hydrogel was the Vergamo fabric of SWCNT:=2:1. Furthermore, the usability evaluation of convenience, usability, and psychological satisfaction results in increased usability of EMSCT compared with conventional hydrogel pads.

Integrated Navigation Filter Design for Trains Considering the Mounting Misalignment Error of the IMU

  • Chae, Myeong Seok;Cho, Seong Yun;Shin, Kyung Ho
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.3
    • /
    • pp.179-187
    • /
    • 2021
  • To estimate the location of the train, we consider an integrated navigation system that combines Inertial Navigation System (INS) and Global Navigation Satellite System (GNSS). This system provides accurate navigation results in open sky by combining only the advantages of both systems. However, since measurement update cannot be performed in GNSS signal blocked areas such as tunnels, mountain, and urban areas, pure INS is used. The error of navigation information increases in this area. In order to reduce this problem, the train's Non-Holonomic Constraints (NHC) information can be used. Therefore, we deal with the INS/GNSS/NHC integrated navigation system in this paper. However, in the process of installing the navigation system on the train, a Mounting Misalignment Error of the IMU (MMEI) inevitably occurs. In this case, if the NHC is used without correcting the error, the navigation error becomes even larger. To solve this problem, a method of easily estimating the MMEI without an external device is introduced. The navigation filter is designed using the Extended Kalman Filter (EKF) by considering the MMEI. It is assumed that there is no vertical misalignment error, so only the horizontal misalignment error is considered. The performance of the integrated navigation system according to the presence or absence of the MMEI and the estimation performance of the MMEI according to the method of using NHC information are analyzed based on simulation. As a result, it is confirmed that the MMEI is accurately estimated by using the NHC information together with the GNSS information, and the performance and reliability of the integrated navigation system are improved.

A study on the mold opening stroke according to the control method of the injection molding machine (사출성형기의 속도제어 방식에 따른 형개거리에 관한 연구)

  • Jung, Hyun-Suk;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.56-61
    • /
    • 2021
  • The increase in automation facilities in the injection molding industry is a very important process control item. The most important item when constructing an unmanned machine using a take-out robot is the "mold opening stroke" of the mold. The injection molding machine control method is divided into hydraulic type and electric type, and there have been few studies on the mold opening distance according to the control method. In this study, the correlation was confirmed by increasing the injection speed to 20, 50, 80, and 100% for the three types of hydraulic control method, open loop and close loop, and electric control method. Through the experiment, the following results were obtained. (1) It can be seen that the reproducibility is excellent with the electric, close loop, and open loop control methods. (2) When the injection speed is set to 50%, the mold opening distance is 263.10~263.27 mm, which is the most reproducible. (3) As a result of ANOVA, both injection speed and mold opening distance showed a significant difference in the hydraulic control method (p<0.05), but it was verified through experiments that there was no significant difference in the electric control method. Based on these results, when electric control is selected rather than hydraulic control, the reproducibility of the mold opening distance is excellent, so it is thought that the taking-out robot can take the object out of the mold more safely.

Fabrication and Evaluation of CdS/ZnS Quantum Dot Based Plastic Scintillator (CdS/ZnS 양자점 기반 플라스틱 섬광체 제작 및 성능평가)

  • Min, Su Jung;Kang, Ha Ra;Lee, Byung Chae;Seo, Bum Kyung;Cheong, Jae Hak;Roh, Changhyun;Hong, Sang Bum
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.450-454
    • /
    • 2021
  • Currently, gamma nuclide analysis is mainly used using inorganic scintillators or semiconductor detectors. These detectors have high resolution but there are less economical, limited in size, and low process ability than plastic scintillators. Therefore, quantum dot-based plastic scintillator was developed using the advantages of the quantum dot nanomaterial and the conventional plastic scintillator. In this study, efficient plastic scintillator was fabricated by adding CdS/ZnS based on the most widely used Cd-based nanomaterial in a polystyrene matrix. In addition, the performance of the commercial plastic scintillator was compared and it was analyzed through radiological measurement experiments. The detection efficiency of fabricated plastic scintillator was higher than commercial plastic scintillator, EJ-200. It is believed that this fabricated plastic scintillator can be used as a radioactivity analyzer in the medical and nuclear facility fields.

A Study on the Radius of Curvature of Concave Optical Fiber Tips fabricated by Laser-Induced Photothermal Effect (레이저 유도 광열 효과를 이용하여 제작된 오목한 광섬유 팁의 곡률 반경에 관한 연구)

  • Choi, Ji-Won;Son, Gyeong-Ho;Yu, Kyoung-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.871-876
    • /
    • 2019
  • We fabricated concave optical fiber tips using hydrofluoric acid solution and photothermal effect induced by $1.55{\mu}m$ wavelength laser applied to an optical fiber. The radius of curvature of the concave optical fiber tips fabricated with different applied laser power, etching time, and concentration of hydrofluoric acid was measured with an optical microscope. Then, we analyzed how the radius of curvature changes for those three variables. In addition, the reliability of the measurement method using a microscope was verified through a free spectral range(FSR) and a scanning electron microscope(SEM). Through this paper, the radius of curvature can be adjusted by the variables of the fabrication process of concave optical fiber tips; thus, it is overcoming the limitations of conventional optical fiber etching methods using hydrofluoric acid solutions.

A Study on CMP Pad Thickness Profile Measuring Device and Method (CMP 패드 두께 프로파일 측정 장치 및 방법에 관한 연구)

  • Lee, Tae-kyung;Kim, Do-Yeon;Kang, Pil-sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.1051-1058
    • /
    • 2020
  • The chemical mechanical planarization (CMP) is a process of physically and chemically polishing the semiconductor substrate. The planarization quality of a substrate can be evaluated by the within wafer non-uniformity (WIWNU). In order to improve WIWNU, it is important to manage the pad profile. In this study, a device capable of non-contact measurement of the pad thickness profile was developed. From the measured pad profile, the profile of the pad surface and the groove was extracted using the envelope function, and the pad thickness profile was derived using the difference between each profile. Thickness profiles of various CMP pads were measured using the developed PMS and envelope function. In the case of IC series pads, regardless of the pad wear amount, the envelopes closely follow the pad surface and grooves, making it easy to calculate the pad thickness profile. In the case of the H80 series pad, the pad thickness profile was easy to derive because the pad with a small wear amount did not reveal deep pores on the pad surface. However, the pad with a large wear amount make errors in the lower envelope profile, because there are pores deeper than the grooves. By removing these deep pores through filtering, the pad flatness could be clearly confirmed. Through the developed PMS and the pad thickness profile calculation method using the envelope function, the pad life, the amount of wear and the pad flatness can be easily derived and used for various pad analysis.

Fabrication and Magnetic Properties of Mg and BaFe12O19 Ferromagnetic Composite Powders by Mechanical Alloying (기계적합금화법에 의한 Mg-BaFe12O19 계 강자성 복합분말의 제조 및 자기특성)

  • Lee, Chung-Hyo
    • Korean Journal of Materials Research
    • /
    • v.31 no.2
    • /
    • pp.61-67
    • /
    • 2021
  • Fabrication of a ferromagnetic composite powder for the magnesium and BaFe12O19 system by mechanical alloying (MA) is investigated at room temperature. Mixtures of Mg and BaFe12O19 powders with a weight ratio of Mg:BaFe12O19 = 4:1, 3:2, 2:3 and 1:4 are used. Optimal MA conditions to obtain a ferromagnetic composite with fine microstructure are investigated by X-ray diffraction, differential scanning calorimetry (DSC) and vibrating sample magnetometer (VSM) measurement. It is found that Mg-BaFe12O19 composite powders in which BaFe12O19 is dispersed in Mg matrix are successfully produced by MA of BaFe12O19 with Mg for 80 min. for all compositions. Magnetization of Mg-BaFe12O19 composite powders gradually increases with increasing the amounts of BaFe12O19, whereas coercive force of MA powders gradually decreases due to the refinement of BaFe12O19 powders with MA time for all compositions. However, it can be seen that the coercivity of Mg-BaFe12O19 MA composite powders with a weight ratio of Mg:BaFe12O19=4:1 and 3:2 for MA 80 min. are still high, with values of 1260 Oe and 1320 Oe compared to that of Mg:BaFe12O19=1:4. This clearly suggests that the refinement of BaFe12O19 powders during MA process for Mg:BaFe12O19=4:1 and 3:2 tends to be suppressed due to ductile Mg powders.

Estimation of the Setting Time of the High Flowing Concrete Using Durometer (Durometer를 이용한 고유동 콘크리트의 응결시간 판정 방법)

  • Han, Min-Cheol;Shin, Yong-Sub;Han, In-Deok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.9
    • /
    • pp.143-150
    • /
    • 2019
  • The purpose of this study was to propose how to determine the setting time related to the determination of the surface finish working time of the concrete using a Durometer, which is used as a rubber hardness meter. Two different types of Durometer were used to measure the setting time of the concrete. High flowing concrete with 40% of water to binder ratio was fabricated maintaining $600{\pm}100mm$ of slump flow. The test results indicated that the application of the Durometer resulted in a high correlation with the penetration resistance tester in both mortar and concrete. When measuring the setting time of the concrete, with properly used with Durometer, evaluation of the setting time of the concrete can be available. Therefore, it is thought that the measurement of the final set of the durometer C type can be useful to decide the limit time of the finishing operation and the time of the rejuvenation of the curing process by measuring the finishing set at 40 HD in the case of the initial set and 10 HD in the case of D type.

Effects of Bed Insert Geometry and Shape of WGS Catalysts on CO Conversion in a Fluidized Bed Reactor for SEWGS Process (SEWGS 공정을 위한 유동층 반응기에서 내부 삽입물의 모양 및 WGS 촉매의 형상이 CO 전환율에 미치는 영향)

  • Ryu, Hojung;Kim, Hana;Lee, Dongho;Bae, Dalhee;Hwang, Taeksung
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.2
    • /
    • pp.150-159
    • /
    • 2013
  • To enhance the performance of SEWGS system by holding the WGS catalyst in a SEWGS reactor using bed inserts, effects of insert geometry and shape of WGS catalysts on CO conversion were measured and investigated. Small scale fluidized bed reactor was used as experimental apparatus and WGS catalyst (particle and tablet) and sand were used as bed materials. The parallel wall type and cross type bed inserts were used to hold the WGS catalysts. The CO conversion with steam/CO ratio was determined based on the exit gas analysis. The measured CO conversion using the bed inserts showed high value comparable to physical mixing cases. Moreover, gas flow direction was confirmed by bed pressure drop measurement for each case. Most of input gas flowed through the catalyst side when we charged tablet type catalyst into the bed insert and this can cause low $CO_2$ capture efficiency because the possibility of contact between input gas and $CO_2$ absorbent is low in this case. New bed insert geometry was proposed based on the results from this study to enhance contact between input gas and WGS catalyst and $CO_2$ absorbent.