• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.04 seconds

Sensitivity simulation on isotopic fissile measurement using neutron resonances

  • Lee, YongDeok;Ahn, Seong-Kyu;Choi, Woo-Seok
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.637-643
    • /
    • 2022
  • Uranium and plutonium are required to be accounted in spent fuel head-end and major recovery area in pyro-process for safeguards purpose. The possibility of neutron resonance technique, as a nondestructive analysis, was simulated on isotopic fissile analysis for large scale process. Neutron resonance technique has advantage to distinguish uranium from plutonium directly in mixture. Simulation was performed on U235 and Pu239 assay in spent fuel and for scoping examination of assembly type. The resonance energies were determined for U235 and Pu239. The linearity in the neutron transmission was examined for the selected resonance energies. In addition, the limit for detection was examined by changing sample density, thickness and content for actual application. Several factors were proposed for neutron production and the moderated neutron source was simulated for effective and efficient transmission measurement. From the simulation results, neutron resonance technique is promising to analyze U235 and Pu239 for spent fuel assembly. An accurate fissile assay will contribute to an increased safeguards for the pyro-processing system and international credibility on the reuse of fissile materials in the fuel cycle.

Measurement of Glass-Silicon Interfacial fracture Toughness and Experimental Evaluation of Anodic Bonding Process based on the Taguchi Method (다구찌 방법에 의한 유리-실리콘 양극접합 계면의 파괴인성치 측정 및 양극접합공정 조건에 따른 접합강도 분석)

  • Kang, Tae-Goo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1187-1193
    • /
    • 2002
  • Anodic bonding process has been quantitatively evaluated based on the Taguchi analysis of the interfacial fracture toughness, measured at the interface of anodically bonded silicon-glass bimorphs. A new test specimen with a pre-inserted blade has been devised for interfacial fracture toughness measurement. A set of 81 different anodic bonding conditions has been generated based on the three different conditions for four different process parameters of bonding load, bonding temperature, anodic voltage and voltage supply time. Taguchi method has been used to reduce the number of experiments required for the bonding strength evaluation, thus obtaining nine independent cases out of the 81 possible combinations. The interfacial fracture toughness has been measured for the nine cases in the range of 0.03∼6.12 J/㎡. Among the four process parameters, the bonding temperature causes the most dominant influence to the bonding strength with the influence factor of 67.7%. The influence factors of other process parameters, such as anodic voltage and voltage supply time, bonding load, are evaluated as 18%, 12% and 2.3%, respectively. The maximum bonding strength of 7.23 J/㎡ has been achieved at the bonding temperature of 460$\^{C}$ with the bonding load of 45gf/㎠, the applied voltage of 600v and the voltage supply time of 25minites.

A Study on the In-process Measurement of Metallic Surface roughness in Cylindrical Grinding by Diode Laser (원통연삭가공시 반도체 레이저 빔을 이용한 금속표면거칠기의 인프로세스 측정)

  • 김희남
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.03a
    • /
    • pp.1-8
    • /
    • 1995
  • This paper proposed a simple method for measuring surface roughness of ground surface. utilizing non-contact in-process measuring system using the diode laser. The measurement system is consisted of a laser unit with a diode laser and a cylindrical lens a detecting unit with polygon mirror and CCD array sensor. and a signal processing unit with a computer and device. During operation, this measuring system can provide information on surface roughness in the measuring distance with a single sampling and simultanilusly monitor the state of the grind wheel. The experimental results, showed that the increase of the feed rate and the dressing speed an caused increase in the surface roughness and when the surface roughness is 4Rmax-10Rmax, the cutting speed is 1653m/min-1665m/min. the feed rate is 0.2m/min-0.9m/min, the dressing speed is 0.2mm/rev-0.4mm/rev, the stylus method and the in-process method can be obtained the same results. thus under limited working conditions. using the proposed system. the surface roughness of the ground surface during cylindrical grinding can be obtained through the in-process measurement method using the diode laser.

  • PDF

Evaluationof Exposure Levels and Detection Rate of Hazardous Factors in the Working Environment, Focused on the Aluminum Die Casting Process in the Automobile Manufacturing Industry (자동차 부품제조 사업장의 유해인자 노출 농도수준 및 검출율 - 알루미늄 다이캐스팅 공정을 중심으로 -)

  • Lee, Duk-Hee;Moon, Chan-Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.100-107
    • /
    • 2018
  • Objectives: This study examines exposure to hazardous substances in the working environment caused by exposure to toxic substances produced in the aluminum die casting process in the automobile manufacturing industry. Materials and Methods: The exposure concentration levels, detection rates and time-trend of 15 hazardous factors in the aluminum die casting process over 10 years(from 2006 to 2016) were used as a database. Results: The study found that hazardous factors in the aluminum die casting process were mostly metals. The rate for detected samples was 70.6%(405 samples), and that for not detected samples was 29.4%. The noise for an eight-hour work shift showed a 49.7% exceedance rate for TLV-TWA. Average noise exposure was 89.0 dB. The maximum exposure level was 105.1 dB. Conclusion: The high numbers of no-detection rates for hazardous substance exposure shows that there is no need to do a work environment measurement. Therefore, alternatives are necessary for improving the efficiency and reliability of the work environment measurement. Moreover, to prevent noise damage, reducing noise sources from automation, shielding, or sound absorbents are necessary.

Radiation Monitoring of Nuclear Material in Process for Reducing Environmental Burden

  • YongDeok Lee;Seong-Kyu Ahn
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.22 no.3
    • /
    • pp.259-271
    • /
    • 2024
  • A procedure for minimizing the environmental burden and maximizing the efficiency of storage sites used for the final disposal of spent fuel has been proposed. In this procedure, fission products (highly mobile and producing heat) are collected, and uranium and TRU-RE (transuranium-rare earth) oxide are independently stored. The possibility and applicability of radiation measurement for monitoring the nuclear materials effectively throughout the process has been simulated and evaluated. For the simulation, the properties of the chemical processes were analyzed, the major radiation emitters were determined, and the production of nuclear materials by chemical reactions were evaluated. In each process, the content of nuclear material was changed by up to 20% to represent abnormal conditions. The results showed that the plutonium peak was matched with the change in the TRU content and the measured signal was changed linearly with respect to the content change of the plutonium. From the neutron measurement, a linear response of the TRU content variation was obtained. In addition, a logic diagram was developed for the nuclear monitoring. The integration of radiation detections is recommended for monitoring the process effectively and efficiently.

Development of capacitive Micromachined Ultrasonic Transducer (II) - Analysis of Microfabrication Process (미세가공 정전용량형 초음파 탐촉자 개발(II) - 미세공정기술 분석)

  • Kim, Ki-Bok;Ahn, Bong-Young;Park, Hae-Won;Kim, Young-Joo;Kim, Kuk-Jin;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.573-580
    • /
    • 2004
  • The main goal of this study was to develop a micro-fabrication process for the capacitive micromachined ultrasonic transducer (cMUT). In order to achieve this goal, the former research results of the micro-electro-mechanical system (MEMS) process for the cMUT were analyzed. The membrane deposition, sacrificial layer deposition and etching were found to be a main process of fabricating the cMUT. The optimal conditions for those microfabrication were determined by the experiment. The thickness, uniformity, and residual stress of the $Si_3N_3$ deposition which forms the membrane of the cMUT were characterized after growing the $Si_3N_3$ on Si-wafer under various process conditions. As a sacrificial layer, the growth rate of the $SiO_2$ deposition was analyzed under several process conditions. The optimal etching conditions of the sacrificial layer were analyzed. The microfabrication process developed in this study will be used to fabricate the cMUT.

Diagnostic Framework for Performance Measurement Practices of Public Broadcasting (공영방송 성과측정관행의 진단 틀)

  • Min, Jae-H.
    • Korean Management Science Review
    • /
    • v.26 no.1
    • /
    • pp.137-159
    • /
    • 2009
  • An organizational performance measurement practice is a function of performance measurement system and performance management system they are currently employing, and its quality is determined by evaluating the followings in a comprehensive manner: first, if they are measuring right things; second, if they are measuring in a right way; third, if they are actively facilitating a process of data collection, structuring, analysis, interpretation, and dissemination; and fourth, if they are using performance measurement results for the primary purposes of performance measurement. This study proposes a diagnostic framework for evaluating the performance measurement practices of public broadcasting which include the qualities of performance measurement and performance management, and develop a structured questionnaire for that purpose. The framework proposed in this study does not serve only as a useful tool for public broadcasting to revise their respective performance measures and performance measurement systems, but it also make their respective performance measurement practices a strategic management tool as well as an operational management one.

Study on the Extraction of Characteristics of LTCC RF Components (LTCC RF 소자 특성 추출에 관한 연구)

  • 유찬세;이우성;강남기;박종철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.2
    • /
    • pp.45-48
    • /
    • 2002
  • LTCC system has many kinds of advantages, like low loss, low cost of process, stability of process etc. But it is so hard to adjust the characteristics of passives in ceramic module after fabrication. So the exact prediction of behavior of components in high frequency region upper than GHz must be made. In this procedure, the exact measurement is need. In this study, many kinds of measurement Jigs are compared and optimized, and measurement methods of each parameter are designed.

  • PDF

Ultrasonic Measurement of Interfacial Layer Thickness of Sub-Quarter-Wavelength

  • Kim, No-Hyu;Lee, Sang-Soon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.577-582
    • /
    • 2003
  • This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave used in the ultrasonic pulse-echo measurements. The technique determines the thickness of a thin layer in a tapered medium from constructive interference of multiple reflection waves. The interference characteristics are derived and investigated in theoretical and experimental approaches. Modified total reflection wave g(t) defined as difference between total and first reflection waves increases in amplitude as the interfacial layer thickness decreases down to zero. A layer thickness less than one-tenth of the ultrasonic wavelength is measured using the maximum amplitude of g(t) with a good accuracy and sensitivity. The method also requires no inversion process to extract the thickness information from the waveforms of reflected waves, so that it makes possible to have the on-line thickness measurement of a thin layer such as a lubricating oil film in thrust bearings and journal bearings during manufacturing process.

Calibration of Inertial Measurement Units Using Pendulum Motion

  • Choi, Kee-Young;Jang, Se-Ah;Kim, Yong-Ho
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.11 no.3
    • /
    • pp.234-239
    • /
    • 2010
  • The utilization of micro-electro-mechanical system (MEMS) gyros and accelerometers in low-level inertial measurement unit (IMU) influences cost effectiveness in a positive way under the condition that device error characteristics are fully calibrated. The conventional calibration process utilizes a rate table; however, this paper proposes a new method for achieving reference calibration data from the natural motion of pendulum to which the IMU undergoing calibration is attached. This concept was validated with experimental data. The pendulum angle measurements correlate extremely well with the solutions acquired from the pendulum equation of motion. The calibration data were computed using the regression method. The whole process was validated by comparing the measurement from the 6 sensor components with the measurements reconstructed using the identified calibration data.