• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.037 seconds

The Micro Electromagnetic Force Measurement of Voice-coil Actuator using Semiconductor Piezoresistive Type Vibration Sensor (실리콘 압저항형 진동 센서를 이용한 Voice-coil형 구동기의 미소 전자력 측정)

  • Gwon, Gi-Jin;Lee, Gi-Chan;Park, Se-Gwang
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.147-152
    • /
    • 1999
  • Semiconductor piezoresistive type vibration sensor was fabricated by using semiconductor process and micromachining technology. To measure the micro electromagnetic force between coil and magnet, fabricated vibration sensor was used. Toapply micro electromagnetic force produced from the micro exciter, small-sized NdFeB permanent magnet was attached on the mass of the fabricated vibration sensor. The measured electromagnetic force are about 5~180dyne when the applied sinusoidal current of 1KHz in the range of 1.5~8mA. The measurement of micro electromagnetic forcewas performed by changing the distance between coil and magnet. Output characteristics of micro electromagnetic force according to the applied coil current were linear. Furthermore, output results were used to get the transfer constant that is important to decide the efficiency and the performance of the coil and magnet.

  • PDF

The Development of Accurate GPS Module Using Discrete-Time $H_{\infty}$ Filter (이산형 $H_{\infty}$ 필터를 이용한 고정밀 GPS 모듈의 개발)

  • Hieu, Nguyen Hoang;Long, Nguyen Phi;Lee, Sang-Hoon;Park, Ok-Deuk;Kim, Hyun-Su;Kim, Han-Sil
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.351-353
    • /
    • 2006
  • In this paper, we present the traditional GPS Position- Velocity (PV) model to apply for both Discrete-Time Kalman Filter and Discrete-Time $H_{\infty}$ Filter. The positioning algorithms of both filters are proposed for a stand-alone low-cost GPS module to increase its accuracy. For disturbance cancellation, the Kalman Filter requires the statistical information about process and measurement noises while the $H_{\infty}$ Filter only requires that these noises are bounded. Experiments show that with the same measurement data, $H_{\infty}$ Filter gives us better positioning results compared with Least-Squared method and Kalman Filter.

  • PDF

Implementation of Automated Motor Fault Diagnosis System Using GA-based Fuzzy Model (유전 알고리즘기반 퍼지 모델을 이용한 모터 고장 진단 자동화 시스템의 구현)

  • Park, Tae-Geun;Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.24-26
    • /
    • 2005
  • At present, KS-1000 which is one of a commercial measurement instrument for motor fault diagnosis has been used in industrial field. The measurement system of KS-1000 is composed of three part : harmonic acquisition, signal processing by KS-1000 algorithm, diagnosis for motor fault. First of all, voltage signal taken from harmonic sensor is analysed for frequency by KS-1000 algorithm. Then, based on the result values of analysis skilled expert makes a judgment about whether motor system is the abnormality or degradation state. But the expert system such a motor fault diagnosis is very difficult to bring the expectable results by mathematical modeling due to the complexity of judgment process. In this reason, we propose an automation system using fuzzy model based on genetic algorithm(GA) that builded a qualitative model of a system without priori knowledge about a system provided numerical input output data.

  • PDF

Results of the key comparison in absolute pressure from 1 Pa to 1000 Pa

  • Hong, Seung-Soo;Shin, Yong-Hyeon;Chung, Kwang-Hwa;A. P. Miiller
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.3
    • /
    • pp.109-115
    • /
    • 2002
  • This paper describes a CCM key comparison of low absolute-pressure standards at seven National Measurement Institutes that was carried out during the period March 1998 to September 1999 in order to determine their degrees of equivalence at pressures in the range 1 Pa to 1000 Pa. The Korea Research Institutes of Standards and Science(KRISS) participated from 10 Pa to 1000 Pa pressure range in 1999. The primary standards, which represent two principal measurement methods, included five liquid-column manometers and four static expansion systems. The transfer standard package consisted of four high-precision pressure transducers, two capacitance diaphragm gauges to provide high resolution at low pressures, and two resonant silicon gauges to provide the required calibration stability.

  • PDF

Data reconciliation for multicomposition processes (다성분 공정을 위한 데이터 보정)

  • 이무호;한종훈;장근수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.36-39
    • /
    • 1996
  • In chemical processes, measurement errors reduce the credibility of information and cause inconsistency in material and energy balances. Because multicomposition flows and temperature measurements make material and energy balances nonlinear equations, data reconciliation becomes a nonlinear constrained optimization problem. In multicomposition processes, if we follow general optimization procedure, the number of measurement variables is so large that data reconciliation requires much computation time. We propose the decomposition procedure to reduce the computation time without the decrease of accuracy of data reconciliation. Decomposition procedure finds global variables, that can reduce the nonlinearity of constraints, and divides two sub-optimization problems. Once we optimize the global variables at upper level, we can easily optimize the remain variables at tower level, We can obtain the short computational time and the same accuracy as SQP optimization method.

  • PDF

Radiation level distribution monitoring system (방사선 분포 모니터링 시스템)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.828-831
    • /
    • 1996
  • Radiation monitoring system is needed at nuclear power plant and nuclear facility. Manual survey techniques are commonly used, but they are time consuming and somewhat inaccurate. Automatic radiation surveys are very important because it provides significant savings in men-rem and wages. Unmanned, remote automatic radiation measurement system should be small and light-weighted in order to mount on robotic system. The system we have developed consists of detection parts, signal processing part, interface, and software part. Position information is provided by using of a collimator. The measurement process is achieved by the scanning of detector and image processing techniques are used to display radiation levels. We designed collimators, detectors, signal processing circuit, and constructed prototype system. The goal of this system is the mapping of camera image and radiation level distribution.

  • PDF

Development of Digital Particle Holographic System for Measurements of the Characteristics of Spray Droplets (분무 액적 특성 계측을 위한 디지털 입자 홀로그래피 시스템의 개발)

  • Yan, Yang;Kang, Bo-Seon
    • Journal of ILASS-Korea
    • /
    • v.15 no.2
    • /
    • pp.53-60
    • /
    • 2010
  • This study presents development of digital particle holographic system and its application to spray field to measure three-dimensional velocities and sizes of spray droplets. A double exposure hologram recording system with synchronization system for time control was established and digital holograms can be recorded in a short time interval. To process recorded holograms, the correlation coefficient method was used for focal plane determination of particles. To remove noises and improve the quality of holograms and reconstructed images, the Wiener filter was adopted. The two-threshold and image segmentation methods were used in binary image transformation. For particle pairing, the match probability method was adopted. The developed system was applied to spray field and three-dimensional velocities and sizes of spray droplets were measured. The measurement results of digital holographic system were compared with those made by laser instruments, PDPA(Phase Doppler Particle Analyzer), which proved the feasibility of in-line digital particle holographic system as a good measurement tool for spray droplets.

Study on the Measurement of Restraining and Opening Forces in Drawbeads (드로우비드 상압력과 인출력 측정에 관한 연구)

  • Moon, S.J.;Keum, Y.T.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.203-206
    • /
    • 2006
  • The drawbeads, which is used for controlling the flow of the sheet by imposing the tension and for preventing the springback in the sheet metal forming process, affects a lot the formability because of the differences in the restraint and opening forces according to the drawbead shapes and dimensions. In this study, the experimental device enabling to measure the drawbead restraining forces and the drawbead opening forces associated with various drawbead shapes and dimensions and their theoretical evaluation are introduced and verified through the experimental measurement of those of a circular drawbead.

  • PDF

Performance Analysis of GPS/INS Integrated Navigation Systems (GPS/INS 통합 항법시스템의 성능분석에 관한 연구)

  • Cho, J.B.;Won, J.H.;Ko, S.J.;Lee, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.822-825
    • /
    • 1999
  • This paper compares two methods of GPS/INS integration ; tightly-coupled integration ana loosely-coupled integration. In the tightly -coupled method an integrated Kalman filter is designed to process raw GPS measurement data for state update and INS data for propagation. The loosely-coupled integration method uses the solution outputs from a stand-alone GPS receiver for update. The loosely-coupled method is simpler and can readily be applied to off-the-self receivers and sensors while the tightly-coupled integration requires access to raw measurement mechanism of the receiver. Simulation result show that the tightly-coupled integration system exhibits better performance and robustness than loosely-coupled integration method.

  • PDF

Integrated Damage Identification System for large Structures via Vibration Measurement

  • JEONG-TAE KIM;SOO-YONG PARK;JAE-WOONG YUN;JONG-HOON BAEK
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.4 no.1
    • /
    • pp.31-37
    • /
    • 2001
  • In this paper, an integrated damage identification system (IDIS) is proposed to locate and size damage in real structures. The application of the IDIS to real structures includes the measurement of modal responses, the construction of damage-detection models, and the implementation of measurements and models into the damage-detection process. Firstly, the theory of the damage identification method is outlined. Secondly, the schematic and each component of the IDIS are described. Finally, the practicality of the IDIS is verified from experiments on two different bridge-models, a model plate-grider and a model truss.

  • PDF