• Title/Summary/Keyword: process equipment

Search Result 3,205, Processing Time 0.04 seconds

Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy (Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가)

  • Lee, Hun Hee;Kim, Chan Kyu;Song, Kwan Soo;Bang, Mun Kyun;Kang, Dong Yun;Sin, Dong Ho;Lee, Du Heon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose : In this study, we evaluated the usefulness of colloid gel(slime) as a compensator for irregular patient surfaces in radiation therapy. Materials and Methods : For this study, colloid gel suitable for treatment was made and four experiments were conducted to evaluate the applicability of radiation therapy. Trilogy(Varian) and CT(SOMATOM, Siemens) were used as treatment equipment and CT equipment. First, the homogeneity according to the composition of colloid gel was measured using EBT3 Film(RIT). Second, the Hounsfield Unit(HU) value of colloid gel was measured and confirmed by CRIS phantom, Eclipse RTP(Eclipse 13.1, Varian) and CT. Third, to measure the deformation and degeneration of colloid gel during the treatment period, it was measured 3 times daily for 2 weeks using an ion chamber(PTW-30013, PTW). The fourth experiment was compared the treatment plan and measured dose distributions using bolus, rice, colloid gel and additional, dose profiles in an environment similar to actual treatment using our own acrylic phantom. Result : First experiment, density of the colloid gel cases 1, 2 and 3 was $1.02g/cm^3$, $0.99g/cm^3$ and $0.96g/cm^3$. When the homogeneity was measured at 6 MV and 9 MeV, case 1 was more homogeneous than the other cases, as 1.55 and 1.98. In the second experiment, the HU values of case 1, 2, 3 were 15 and when the treatment plan was compared with the measured doses, the difference was within 1 % at all 9, 12 MeV and a difference of -1.53 % and -1.56 % within the whole 2 % at 6 MV. In the third experiment, the dose change of colloid gel was measured to be about 1 % for 2 weeks. In the fourth experiment, the dose difference between the treatment plan and EBT3 film was similar for both colloid gel and bolus, rice at 6 MV. But colloid gel showed less dose difference than bolus and rice at 9 MeV. Also, dose profile of colloid gel showed a more uniform dose distribution than the bolus and rice. Conclusion : In this study, the density of colloid gel prepared for radiation therapy was $1.02g/cm^3$ similar to the density of water, and alteration or deformation was not observed during the radiotherapy process. Although we pay attention to the density when manufacturing colloid gel, it is sufficient in that it can deliver the dose uniformly through the compensation of the patient's body surface more than the bolus and rice, and can be manufactured at low cost. Further studies and studies for clinical applications are expected to be applicable to radiation therapy.

  • PDF

A Methodology to Develop a Curriculum based on National Competency Standards - Focused on Methodology for Gap Analysis - (국가직무능력표준(NCS)에 근거한 조경분야 교육과정 개발 방법론 - 갭분석을 중심으로 -)

  • Byeon, Jae-Sang;Ahn, Seong-Ro;Shin, Sang-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.1
    • /
    • pp.40-53
    • /
    • 2015
  • To train the manpower to meet the requirements of the industrial field, the introduction of the National Qualification Frameworks(hereinafter referred to as NQF) was determined in 2001 by National Competency Standards(hereinafter referred to as NCS) centrally of the Office for Government Policy Coordination. Also, for landscape architecture in the construction field, the "NCS -Landscape Architecture" pilot was developed in 2008 to be test operated for 3 years starting in 2009. Especially, as the 'realization of a competence-based society, not by educational background' was adopted as one of the major government projects in the Park Geun-Hye government(inaugurated in 2013) the NCS system was constructed on a nationwide scale as a detailed method for practicing this. However, in the case of the NCS developed by the nation, the ideal job performing abilities are specified, therefore there are weaknesses of not being able to reflect the actual operational problem differences in the student level between universities, problems of securing equipment and professors, and problems in the number of current curricula. For soft landing to practical curriculum, the process of clearly analyzing the gap between the current curriculum and the NCS must be preceded. Gap analysis is the initial stage methodology to reorganize the existing curriculum into NCS based curriculum, and based on the ability unit elements and performance standards for each NCS ability unit, the discrepancy between the existing curriculum within the department or the level of coincidence used a Likert scale of 1 to 5 to fill in and analyze. Thus, the universities wishing to operate NCS in the future measuring the level of coincidence and the gap between the current university curriculum and NCS can secure the basic tool to verify the applicability of NCS and the effectiveness of further development and operation. The advantages of reorganizing the curriculum through gap analysis are, first, that the government financial support project can be connected to provide quantitative index of the NCS adoption rate for each qualitative department, and, second, an objective standard is provided on the insufficiency or sufficiency when reorganizing to NCS based curriculum. In other words, when introducing in the subdivisions of the relevant NCS, the insufficient ability units and the ability unit elements can be extracted, and the supplementary matters for each ability unit element per existing subject can be extracted at the same time. There is an advantage providing directions for detailed class program and basic subject opening. The Ministry of Education and the Ministry of Employment and Labor must gather people from the industry to actively develop and supply the NCS standard a practical level to systematically reflect the requirements of the industrial field the educational training and qualification, and the universities wishing to apply NCS must reorganize the curriculum connecting work and qualification based on NCS. To enable this, the universities must consider the relevant industrial prospect and the relation between the faculty resources within the university and the local industry to clearly select the NCS subdivision to be applied. Afterwards, gap analysis must be used for the NCS based curriculum reorganization to establish the direction of the reorganization more objectively and rationally in order to participate in the process evaluation type qualification system efficiently.

A Study on Status of Utilization and The Related Factors of Primary Medical Care in a Rural Area (일부 농촌지역의 일차의료이용실태와 그 관련요인에 관한 연구)

  • Wie, Cha-Hyung
    • Journal of agricultural medicine and community health
    • /
    • v.20 no.2
    • /
    • pp.157-168
    • /
    • 1995
  • This study was carried out, through analyzing the annual reports(year of 1973-1993) on health status of Su Dong-Myun, and specific survey data of 332 households(Su Dong-Myun 209, Byul Nae-Myun 123), located in Nam Yang Ju-Si, Kyung Gi-Do, from July 20 to July 31, 1995, to find out more effective means for primary medical care in a rural area. The results were as fellows : 1. Number of population in Su Dong-Myun was 5,419 in 1973, 4,591(the lowest) in 1987 and 5,707 in 1995. In the composition rate of population, "0-14" of age group showed markedly decreasing tendency from 43.1% in 1975, to 19.1% in 1995, however "65 and over" markedly in creasing tendency form 5.3% in 1975 to 9.8% in 1995. 2. Annual utilization rate per 1,000 inhabitants in Su Dong-Myun showed markedly increasing tendency from 1973 to 1977 such as 343 in 1973, 540 in 1975, 900 in 1977. However, since 1979, the rate showed rapidly decreasing tendency, such as 846 in 1979, 519 in 1985, 190 in 1991 and 1993. 3. The morbid household rate per year was 53.6% of respondents and the rate per 15 days was 48.2%. In disease classification rate of morbid household per year, Arthralgia & Neuralgia was the highest rate(33.9%) and gastro-intestinal disorder(19.3%), Cough(11,9%), Hypertension(7.8%), Accident(3.2%) in next order. 4. In the utilizing facilities for Primary Medical Care, Medical facilities was showed the highest rate(58.1% of respondents) and Pharmacy and Drug Shp(33.1%), Tradition Method(4.0%) in next order. In the Medical facilities, General private clinic was showed the highest rate(34.3%) and specific private Clinic(22.3%), Hospital(19.0%), Health (Sub)center(16.3%), Nurse practitioner (3.3%), Oriental hospital and clinic(2.7%) in next order. 5. Experience rate, utilizing health subcenter was 51.8% of the respondents, and it was 55.0% in Su Dong-Myun and 46.3% in Byul Nae-Myun. In utilization times of health subcenter, times-rate showed next orders such as 1-2 times/6months(31.6%), 1-2 times/year (22.1%), 1-2 times/months(19.2%), 1-2 times/3months(15.6%). 6. In objectives, visiting Health Subcenter, Medical Care was the highest rate(59.8% of the respondents) and health control(23.3%) was in next order. In Medical Care, Primary Care by general physician was higher rate(51.1%) almost all. In the Health control, Immunization too was high rate(18.0%) in health control activities. 7. The reasons rate, utilizing health subcenter showed next order, such as distance to Medical facilities(33.0% of the respondents), Medical Cost(28.1%), Simple process of consultation (10.8%), Effectiveness of cure(7.6%), Function of primary medical care(7.0%) and Attitude of physician(6.5%). 8. In the affecting factors to utilization of primary medical facilities, medical needs was showed the highest rate(29.5% of the respondents) and medical cost(15.4%), distance to medical facilities(14.2%), traffic vehicle(14.2%) and farm work(6.9%) in next order. 9. In the priority between 'daily farm work,' and 'primary medical care', only 46.4% of respondents answered that primary health care is more important than the daily farm work The 22.6% of respondents answered 'daily farm work', and the 12.3% answered 'the equal of the both'. 10. In the criterion of medical facilities choice, medical knowledge and technical quality was showed the highest rate(56.3%), distance or time to medical facilities(10.9%), sincerity and kindness of physician(9.4%), medical cost(8.7%) and traffic vehicle(6.5%) in next order 11. In the advise for improvement of health subcenter function, the 36.1% of respondents answered that 'enforcement of medical personnel and equipment' was required, and then 'improved medical technology'(25.5%), 'good attitude of physician'(14.9%), 'improved medical system'(13.3%), 'enforced drug'(6.7%) in next order. 12. The study on affecting factors to utilization of primary medical facilities was very difficult subject to systematize the analyzed results, due to a prejudice of protocol planner, surveyer and respondent, and variety and overlapping of subject matter.

  • PDF

Setup of Infiltration Galleries and Preliminary Test for Estimating Its Effectiveness in Sangdae-ri Water Curtain Cultivation Area of Cheongju, Korea (청주 상대리 수막재배지의 지중 침투형 갤러리 설치와 예비 주입시험)

  • Moon, Sang-Ho;Kim, Yongcheol;Kim, Sung-Yun;Ki, Min-Gyu
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.445-458
    • /
    • 2016
  • Most of water curtain cultivation (WCC) area in Korea has been inveterately suffering from the gradual draw-down of groundwater level and related shortage of water resources at the late stage of WCC peak time. To solve this problem, artificial recharge techniques has been recently applied to some WCC area. This study introduces infiltration gallery, which is one of the artificial recharge methods, and tentatively examined the effectiveness of three galleries installed at Sangdae-ri WCC area of Cheongju City. Seven galleries are set up at each empty space between eight vinyl houses in this area and its dimension is designed as 50 cm in each width and height and 300 cm in each length. Installation process was including bed excavation, backfill with gravels and silica sands, and completion of gallery by equipment of piezometer and covering with non-woven cloth. For each B, C, D gallery, 3 types of test including preliminary, four step and one long-term injection were performed. The first preliminary test showed the rough relations between injection rates and water level rise as follows; 20 cm and 30 cm level rise for $33.29{\sim}33.84m^3/d$ and $45.60{\sim}46.99m^3/d$ in B gallery; 0 cm, 16 cm and 33 cm level rise for $21.1m^3/d$, $33.98m^3/d$ and $41.69m^3/d$ in C gallery; 29 cm and 42 cm level rise for $48.10m^3/d$ and $52.23m^3/d$ in D gallery. Afterwards, more quantitative results estimating effectiveness of artificial recharge were reasoned out through stepped and long-term injection tests, which is expected to be employed for estimating water quantity re-injected into the aquifer through these galleries by natural injection over the period of WCC peak time.

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Monitoring on Microbiological Contamination of Packed Ice Creams from Manufacturing Factories in Korea (국내 제조공장에서 생산된 아이스크림류의 미생물학적 오염실태 조사)

  • Heo, Eun-Jeong;Ko, Eun-Kyung;Kim, Young-Jo;Seo, Kun-Ho;Park, Hyun-Jung;Wee, Sung-Hwan;Moon, Jin San
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.3
    • /
    • pp.202-206
    • /
    • 2014
  • In this study, the bacteriological survey was examined on ice creams at manufacturing factories in Korea during the summer season of 2011. The nineteen selected among 166 samples by preliminary test were collected from 11 different manufacturing factories in four major manufacturers in May 2011. Samples from ice milk, ice creams, sherbets, and non milk fat ice creams were tested for the total aerobic bacteria, coliform bacteria, and five food borne pathogens, respectively. The results showed that the coliforms including E. coli O157:H7, Salmonella spp., Staphylococcus aureus, Clostridium perfringens, and Listeria monocytogenes were not detected on all the ice creams. The total aerobic bacteria of the packed samples examined ranged between $2.5{\times}10^3$ and $5.5{\times}10^5cfu/g$. One ice cream, two sherbets, and four ice milk samples exceeded the acceptable limits of total aerobic bacteria according to the Korean standards for ice cream ($1.0{\times}10^5cfu/g$) and others ($5.0{\times}10^4cfu/g$). The levels of these microorganisms from ice creams were higher in three original equipment manufacturers than seven self-manufacturers. Three of ten ice creams (30.0%), three of six ice milks (50.0%), and one of two sherbets (50%) exceeded the acceptable limits of total aerobic bacteria, respectively. The personnel hygiene procedures with chocolate and vanilla chip addition from the manufacturing process were the main sources of the microbial contamination of stick-bar type ice creams when being produced in a factory. Improvement of the hazard analysis critical control points (HACCP) system should be introduced into the ice cream factory to improve the microbial quality of the ice cream products in Korea.

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

Evaluation on the Accuracy of the PPS in the Proton Therapy System, Which Uses the Self Made QA Phantom (자체 제작한 QA Phantom을 이용한 양성자 PPS (Patient Positioning System)의 정확성 평가)

  • Lee, Ji-Eun;Kim, Jae-Won;Kang, Dong-Yoon;Choi, Jae-Hyeok;Yeom, Du-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.115-121
    • /
    • 2012
  • Purpose: The process of the proton treatment is done by comparing the DRR and DIPS anatomic structure to find the correction factor and use the PPS to use this factor in the treatment. For the accuracy of the patient set up, the PPS uses a 6 axis system to move. Therefore, there needs to be an evaluation for the accuracy between the PPS moving materialization and DIPS correction factor. In order to do this, we will use a self made PPS QA Phantom to measure the accuracy of the PPS. Materials and Methods: We set up a PPS QA Phantom at the center to which a lead marker is attached, which will act instead of the patient anatomic structure. We will use random values to create the 6 axis motions and move the PPS QA Phantom. Then we attain a DIPS image and compare with the DRR image in order to evaluate the accuracy of the correction factor. Results: The average correction factor, after moving the PPS QA Phantom's X, Y, Z axis coordinates together from 1~5 cm, 1 cm at a time, and coming back to the center, are 0.04 cm, 0.026 cm, 0.022 cm, $0.22^{\circ}$, $0.24^{\circ}$, $0^{\circ}$ on the PPS 6 axis. The average correction rate when moving the 6way movement coordinates all from 1 to 2 were 0.06 cm, 0.01 cm, 0.02 cm, $0.1^{\circ}$, $0.3^{\circ}$, $0^{\circ}$ when moved 1 and 0.02 cm, 0.04 cm, 0.01 cm, $0.3^{\circ}$, $0.5^{\circ}$, $0^{\circ}$ when moved 2. Conclusion: After evaluating the correction rates when they come back to the center, we could tell that the Lateral, Longitudinal, Vertical were all in the acceptable scope of 0.5 cm and Rotation, Pitch, Roll were all in the acceptable scope of $1^{\circ}$. Still, for a more accurate proton therapy treatment, we must try to further enhance the image of the DIPS matching system, and exercise regular QA on the equipment to reduce the current rate of mechanical errors.

  • PDF

Improvement of Net Structure and Operating System in Purse Seine Fishery for Gizzard-shad, Konosirus Punctatns(I) -Underwater Geometry and Behaviour of fish School to the Net - (전어 선망 어구 및 조업 시스템 개발(I) -어구의 수중 형상 및 전어 어군의 대망 행동-)

  • 장덕종;신형호;김동수;김진건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.2
    • /
    • pp.156-163
    • /
    • 2002
  • In order to development the construction and dimension of fishing gear for gizzard shad coastal purse seine, first of all investigated to the sinking speed and underwater geometry of net, behaviour of fish school to the net during the fishing operation In the field. The results obtained are summarized as follows; 1. Average sinking speed of net was 13cm/sec in bunt, 9.0cm/sec and 9.5cm/sec in 170m and 280m of center, 4.9cm/sec in end wing side, therefore was fastest in start of shooting and decreased gradually during the shooting process. 2. The most of leadline was reached in bottom from the shooting immediately to hauling time and the mean depth of timber bar used equipment for the escaping prevention of fish school was within the 2.7m. 3. The fish school of gizzard shad was appearanced higher density and remained to the most time in bottom than the surface and repeated to vortical movement, and its tendency to distinct in rapid time of tide current. 4. Behaviour of fish school in the net was showed to the vortical movement by sinking and rising immediately with the shooting of net and then divide with the two shape to follow round the wall of net and no patterns straightly movement in the net, and tendency easily catched in fish school of the wall of net. 5. Escaping of fish school in the gap of wing side was to busy after that seting the timber bar, therefore its function for escaping prevention of fish school was very lowed. 6. Escaping behaviour of fish school was differenced with the depth of fishing ground, the above 20m escaped to busy through the below in ledline because the sinking speed of fish school is fast than the net.

Remanufacturing of Commercial $V_2O_5-WO_3/TiO_2$ Catalyst used in the SCR Process of Incinerator (소각장 SCR 공정에서 사용되는 상용 $V_2O_5-WO_3/TiO_2$ 촉매의 재제조에 관한 연구)

  • Yoon, Goan-Gu;Yoo, Man-Sik;Lim, Jong-Sun;Kim, Tae-Won;Park, Hea-Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.9
    • /
    • pp.970-977
    • /
    • 2005
  • The commercial $V_2O_5-WO_3/TiO_2$ catalysts which had been exposed to the off gas from incinerator for a long time were remanufactured by washing with distilled water and arid solution and reimpregnation with catalytic active components($V_2O_5-WO_3$). The catalytic properties and NOx conversion reactivity of those catalysts were examined by analysis equipment and NOx conversion experiment. Under the experimental condition used in this study, the remanufactured catalysts activated by distilled water ultra sonic cleaning, the catalytic activity was recovered in the range of $66{\sim}93%$ of that of the fresh and the maximum activity was showed when the ultra sonic cleaning time was more than 3 minutes. The remanufactured catalysts by acid solution ultra sonic cleaning, the catalytic activity was recovered in the range of $81{\sim}97%$ of that of the fresh catalyst and the maximum catalytic activity was shooed when the pH of the acid solution was 5. The remanufactured catalysts by reimpregnation with $V_2O_5$ and $WO_3$, the catalytic activity was recovered in the range of $87{\sim}100%$ of that of the fresh catalyst. Maximum catalytic activity was showed when the $V_2O_5$ was reimpregnated more than 1.0 wt %. In this case, the catalytic activity was recovered 97% of that of the fresh catalyst especially at the $150^{\circ}C$ of the experimental temperature.