• Title/Summary/Keyword: problem analysis

Search Result 16,359, Processing Time 0.044 seconds

The Joint Determination of Leverage and Debt Maturity (레버리지와 부채만기 결정의 상호관계)

  • Kim, Chi-Soo;Kwon, Kyeung-Taek
    • The Korean Journal of Financial Management
    • /
    • v.22 no.1
    • /
    • pp.1-36
    • /
    • 2005
  • In this study, we analyzed determinant factors of leverage ratio and debt maturity for Korean firms in the simultaneous equation system using 2SLS (two stage least square) method under assumption that two variables are jointly determined in the capital structure decision. As a result of the analysis, we found that leverage ratio and debt maturity are positively related. Also, as for determinant factors of debt maturity, agency cost hypothesis, asset maturity matching hypothesis, signalling and liquidity risk hypothesis are all generally supported, and further leverage ratio are significantly positively related with firm size, but negatively related with default risk. However, when we divided samples into groups according to bank debt level and Chaebul affiliation, with contrast to existing study which worked on similar issues with OLS, we found no evidence supporting the argument that the information asymmetry problem is less severe in firms with more bank debt, whereas information asymmetry and financial constraint problems are more severe in non-Chaebul affiliated firms.

  • PDF

Simulation training applying SBAR for the improvement of nursing undergraduate students' interdisciplinary communication skills (SBAR 적용 시뮬레이션 교육이 간호학생의 의료팀간 의사소통능력 향상에 미치는 효과)

  • Ha, Yikyung;Lee, Yoonju;Lee, Yeon Hee
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.2
    • /
    • pp.407-419
    • /
    • 2017
  • In this paper, we aim to evaluate the effect of simulation training with a focus on the application of SBAR for the improvement of communication skills of nursing students with physician. The results of the analysis of 25 videos recorded pre/post-simulation were as follows: In terms of the SBAR score, "the most recently measured vital signs" in stage B increased significantly (Z = -2.448, p =.014); the frequency of step-by-step progress in SBAR did not advance to the SBA or SBAR stage in the pre-simulation stage, but increased to 48% post-simulation. The frequencies of SBAR evaluation items mentioned in the post-simulation were the following order: the name of the patient (96%), nurse's name (80%), most recently measured oxygen saturation (76%), and main symptoms (60%). The results of the nurse's judgment (A), request for additional prescription or request for the doctor's direct patient visit (R) were not mentioned. Therefore, it is necessary to consider the application of SBAR in simulation training, which requires problem solving through cooperation with physicians, because it has a positive effect on education in nurse-physician communication.

Evaluation of marginal fidelity of copy-milled and CAD/CAM all ceramic crowns

  • Jeong Seung-Mi;Kang Dong-Wan;Wolf Christoph
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.243-249
    • /
    • 2001
  • Statement of the problem. The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems or Copy-milling systems there is a need for evaluating the quality levels of these new fabrication techniques. Purpose. This study was to evaluate the fitting accuracy of machined all-ceramic crowns made out of an industrially prefabricated feldspathic porcelain. Material and Methods. Three master models with different cutting depth (0.8mm/1.0mm/1.2mm)were produced using a palladium-silver alloy. A total of 36 working dies, 12 of each form, was used for the modellation of prototype resin copings and 36 additional crowns, 12 of each cutting depth, were produced by using the $CEREC^{(R)}2$ system for all crowns. The maginal fit of all 72 crowns was then evaluated on their respective master die at 54 circularly staggered points of measurement per crown under a fixation pressure of 30 N by using a computerized video image system. Results. The medians of the copy-milled $CELAY^{(R)}$ crowns ranged from 29 to $36{\mu}m$. The highest value for the marginal gap was found in group B (cutting depth 1.0mm) at $107{\mu}m$. The median for the $CEREC^{(R)}2$ crowns was found between 43.5 and $70{\mu}m$. The maximum values for all three groups ranged from $181{\mu}m$ to $286{\mu}m$. With $286{\mu}m$ the highest value for marginal gap was found in group C. the Kruskal-Wallis test and multiple comparisons analysis procedure revealed a significant influence of the production technique on the marginal fit in all three groups (p<0,02). Conclusion. 1. The $CELAY^{(R)}$ system is capable to produce all-ceramic crowns with a significantly better marginal fit than the $CEREC^{(R)}2$ system. 2. As far as premolar crowns produced with the $CEREC^{(R)}2$ system are concerned, the cutting depth has a significant influence on fitting accuracy. 3. The production of crowns with an acceptable marginal fit is possible with both systems. However, adhesive luting is recommended for milled feldspathic porcelain crowns.

  • PDF

THE EFFECT OF SOLDER AND LASER WELD ON CORROSION OF DENTAL ALLOYS (납착법과 레이저융합법이 치과용 합금의 부식에 미치는 영향)

  • Baik Jin;Woo Yi-Hung;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.264-279
    • /
    • 2005
  • Statement of problem. Intraoral corrosion not only affects the esthetic and function of metallic dental restoration, but also has biologic consequences as well. Therefore, corrosion is considered a primary factor when choosing the dental alloy and laboratory technique. Purpose. The objective of this study was to compare the effects of solder and laser weld on corrosion Material and methods. Test specimens were made of 2 types of gold alloys, Co-Cr and Ni-Cr alloy and fabricated 3 methods, respectively: as cast, solder, and laser weld. For the analysis of corroding properties, potentiodynamic polarization test and immersion test conducted. The potentiodynamic polarization scan curve were recorded in 0.9% NaCl solution(pH 7) using Potentiostat/Galyanostat Model 273A. All specimens were exposed to 0.9% NaCl solution(pH 2.3) during 14 days. Elemental release into corrosive solution was measured by atomic emission spectrometry Differences in corrosion potential and mass release were determined using ANOVA. Results and conclusion. Through analyses of the data, following results were obtained. 1. In Pontor MPF and Wiron 99, corrosion potential of the solder group was statistically lower than as cast and laser weld group (p<0.05) , but there was no difference between corrosion potential of solder group and laser weld group in Pontor MPF and no differences between as cast and laser weld group (p>0.05). In Jel-Bios 10 and Wirobond, there was no difference of corrosion potential according to joining methods(p>0.05). 2. In all tested alloys, the amount of released metallic ion was greatest in the solder group(p<0.05). There was no difference between as cast group and laser weld group in Jel-Bios 10 and Wirobond(p>0.05). 3. In scanning electron microscopic examination. except soldered Wiron 99 specimens, it is impossible to discriminate the corrosive property of solder and laser weld. 4. Under the this experimental circumstances, laser weld appears superior to the solder when corrosion is considered.

Dislodgement resistance of modified resin-bonded fixed partial dentures utilizing tooth undercuts: an in vitro study

  • Doh, Re-Mee;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.85-90
    • /
    • 2009
  • STATEMENT OF PROBLEM. Over the years, resin-bonded fixed partial dentures (RBFPDs) have gone through substantial development and refinement. Several studies examined the biomechanics of tooth preparation and framework design in relation to the success rate of RBFPDs and considered retention and resistance form essential for increase of clinical retention. However, these criteria required preparations to be more invasive, which violates not only the original intentions of the RBFPD, but may also have an adverse effect on retention due to loss of enamel, an important factor in bonding. PURPOSE. The object of this in vitro study was to compare the dislodgement resistance of the new types of RBFPDs, the conventional three-unit fixed partial denture, and conventional design of RBFPD (Maryland bridge). MATERIAL AND METHODS. Fifty resin mandibular left second premolars and second molars were prepared on dentiforms, according to the RBFPD design. After model fabrication (five group, n = 10), prostheses were fabricated and cemented with zinc phosphate cement. After cementation, the specimens were subjected to tensile loading at a cross head speed of 4 mm/min in a universal testing machine. The separation load was recorded and analyzed statistically using one-way analysis of variance followed by Duncan's multiple range test. RESULTS. Group V, the pin-retained RBFPDs, had the highest mean dislodgement resistance, whereas specimens of group II, the conventional RBFPDs, exhibited a significantly lower mean dislodgement resistance compared to the other 4 groups (P <.05). There were no significant differences between group I, III, and IV in terms of dislodgement resistance (P>.05). Group V had the highest mean MPa (N/$mm^2$) (P <.05). There was no significant difference between groups I, II, III and IV (P > .05). CONCLUSION. Within the limits of the design of this in vitro study, it was concluded that: 1. The modified RBFPDs which utilizes the original tooth undercuts and requires no tooth preparation, compared with the conventional design of RBFPDs, has significantly high dislodgement resistance (P < .05). 2. The modified RBFPDs which utilizes the original tooth undercuts and requires minimal tooth preparation, compared with the conventional FPDs, has significantly no difference in retention and dislodgement resistance)(P>.05). 3. The pin-retained FPDs showed a high dislodgement resistance compared to the conventional three-unit FPDs (P<.05).

Cervical design effect of dental implant on stress distribution in crestal cortical bone studied by finite element analysis (유한요소법을 이용한 임플란트 경부 디자인이 골응력에 미치는 영향 분석)

  • Kim, Kyung-Tak;Jo, Kwang-Heon;Lee, Cheong-Hee;Yu, Won-Jae;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.385-393
    • /
    • 2009
  • Statement of problem: High stress concentration on the crestal cortical bone has been regraded as a major etiologic factor jeopardizing long term stability of endosseous implants. Purpose: To investigate if the design characteristics of crestal module, i.e. internal type, external type, and submerged type, affect stress distribution on the crestal cortical bone. Material and methods: A cylindrical shaped implant, 4.3 mm in diameter and 10 mm in length, with 3 different crestal modules, i.e. internal type, external type, and submerged type, were analysed. An axisymmetric scheme was used for finite elment formulation. A vertical load of 50 N and an oblique load of 50N acting at $45^{\circ}$ with the implant's long axis was applied. The peak crestal bone stress acting at the intersection of implant and crestal bone was compared. Results: Under vertical load, the crestal bone stress was high in the order of internal, external, and submerged types. Under the oblique loading condition, it was in the order of internal, submerged, and external types. Conclusion: Crestal module design was found to affect the level of the crestal bone stresses although the actual amount was not significant.

A COMPARATIVE STUDY OF THE 1-PIECE AND 2-PIECE CONICAL ABUTMENT JOINT: THE STRENGTH AND THE FATIGUE RESISTANCE

  • Kwon, Taek-Ka;Yang, Jae-Ho;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.780-786
    • /
    • 2007
  • Statement of problem. The performance and maintenance of implant-supported prostheses are primarily dependent upon load transmission both at the bone-to-implant interface and within the implant-abutment-prosthesis complex. The design of the interface between components has been shown to have a profound influence on the stability of screw joints. Purpose. The Purpose of this study was to compare the strength and the fatigue resistance of 1-piece and 2-piece abutment connected to oral implant, utilizing an internal conical interface. Material and methods. Twenty $Implatium^{(R)}$ tapered implants were embedded to the top of the fixture in acrylic resin blocks. Ten $Combi^{(R)}$(1-piece) and $Dual^{(R)}$(2-piece) abutments of the same dimension were assembled to the implant, respectively. The assembled units were mounted in a testing machine. A load was applied perpendicular to the long axis of the assemblies and the loading points was at the distance of 7mm from the block surface. Half of 1-piece and 2-piece abutment-implant units were tested for the evaluation of the bending strength, and the others were cyclically loaded for the evaluation of the fatigue resistance until plastic deformation occurred. Nonparametric statistical analysis was performed for the results. Results. Mean plastic and maximum bending moment were $1,900{\pm}18Nmm,\;3,609{\pm}106Nmm$ for the 1-piece abutment, and $1,250{\pm}31Nmm,\;2,688{\pm}166Nmm$ for the 2-piece abutment, respectively. Mean cycles and standard deviation when implant-abutment joint showed a first plastic deformation were $238,610{\pm}44,891$. cycles for the 1-piece abutment and $9,476{\pm}3,541$ cycles for the 2-piece abutment. A 1-piece abutment showed significantly higher value than a 2-piece abutment in the first plastic bending moment (p<.05), maximum bending moment (p<.05) and fatigue strength (p<.05). Conclusion. Both 1-piece and 2-piece conical abutment had high strength and fatigue resistance and this suggests long-term durability without mechanical complication. However, the 1-piece conical abutment was more stable than the 2-piece conical abutment in the strength and the fatigue resistance.

THE EFFECT OF GOLD ELECTROFORMING PROCEDURE ON GOLD-SILVER-PALLADIUM ALLOY

  • Hwang, Bo-Yeon;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.303-309
    • /
    • 2007
  • Statement of problem. The effect of gold electroforming on gold alloy was not studied. Purpose. This in vitro study investigate the effect of gold electroforming on gold-silver-palladium alloy. Material and methods. Three pieces of gold strips had undergone the electroforming procedures on one side and then half of the side again electroformed. The set mode for this study was program 1 ($200{\mu}m$). And the processing time was 15min (1/20 time to form $200{\mu}m$ coping). The confocal laser scanning microscope (PASCAL 5, Carl Zeiss, Bernried, Germany) was used to measure the thickness of the pure gold layer electroformed on the gold strips. Half of the gold strip was coated two times with electroformed gold, and the other half one time. The data from the cone focal laser system was processed to get the vertical profile of the strips and the difference of the vertical height between the double coated and single coated layer was regarded as the thickness of the gold coating. The layer thickness value to built 3D image of the cone-focal laser was set $0.5{\mu}m$. Next to the measurement of the thickness of the coating, the Vicker's hardness test was done. It was performed on the double coated surface, single coated surface and non-coated surface (back side) three times each. Results. The mean thickness value gained from gold electroforming technique was measured to be $22{\mu}m$ for sample 1, $23{\mu}m$ for sample 2, $21{\mu}m$ for sample 3. In the same condition of time, power and the amount of electrolyte, the data showed no difference between samples. According to the results of variance analysis, the differences among the variations in number of coating were statistically insignificant (p>0.05), meaning that the two times of gold electroforming coating did not change the hardness of gold-silver-palladium alloy. Conclusion. The test of thickness of gold coating proved the coherency of the gold electroforming procedure, in other words, when the power, the exposed surface area, processing time and the amount of electrolytes were set same, the same thickness of gold would be coated on. The hardness test showed that the electroformed gold coating did not change the hardness of the gold-silver-palladium alloy when it is coated not more than $45{\mu}m$.

Development and Management of the Advanced STEAM Teacher Training Program (STEAM 심화과정 교사연수 프로그램 개발 및 운영)

  • Hahn, Insik;Hwang, Shinyoung;Yoo, Jungsook
    • Journal of The Korean Association For Science Education
    • /
    • v.36 no.3
    • /
    • pp.399-411
    • /
    • 2016
  • The purpose of this study is to investigate implications for future STEAM education by analyzing the surveys by the in-service teachers who participated in the Advanced STEAM Teacher Training Program(ASTTP) for raising interests and understanding of science and technology and nurturing STEAM literacy and problem-solving ability of students. ASTTP was developed for promoting 'teacher competence for STEAM.' ASTTP is a 60-hour program(4 credits), which includes offline intensive course of 38 hours, online training course of 12 hours, a course of implementation at schools for 5 hours, and a workshop for 5 hours (based on the 2014 program). For the offline intensive course, teachers take various professional development classes and activities, such as open-laboratory tours, advanced experiments, mentoring programs, and team projects as well as lectures on diverse disciplines. For the online course, teachers take online classes freely while they are encouraged to work with other teachers in groups. After taking both online and offline courses, the teachers are required to implement their STEAM lesson plans in their classrooms. Finally at the workshop, some selected teachers share how successfully they have implemented STEAM education. About 700 teachers have successfully taken the program from 2012 to 2014. Based on the surveys by the teachers, the program has been modified and improved. Our analysis shows increased professional development in STEAM education for the participating teachers. This study can provide some implication and helpful insights for people who need to develop and manage teacher training programs for STEAM education and other education programs in general.

A Study on How Well-Being Influences Consumer Behavior and Restaurant Choice (외식 소비자의 웰빙 수준과 웰빙 태도가 레스토랑의 선택 속성에 미치는 영향)

  • Son, Young-Jin;Hong, Ki-Woon
    • Culinary science and hospitality research
    • /
    • v.15 no.1
    • /
    • pp.209-224
    • /
    • 2009
  • The objective of this study is to find out how well-being influences consumer behavior of dining-out. Based on this objective, this study covers plans for improving marketing strategies, which contributes to menu development and purchase behavior of consumers. This study consists of two parts : a research based on the review of the literature and empirical study methods. The finding of the study would also be valuable for the development of management of advertising strategies to be implemented in the foodservice industry. Based on the survey statistics, Program SPSS 12.0 and Amos 5.0 were used in order to look into a casual relationship among group units. The findings of the demonstration analysis are as follows. Most of previous research regarding well-being in local study is psychological well-being dealt with individual health and psychological satisfaction. On the other hand, social well-being is likely to focus on public relation rather than private concerns. The fact that the term 'well-being' have not been definitely defined yet was a problem in research. Also, well-being should not be recognized as a temporary trend but as a general trend. Therefore, it is necessary to understand consumer behavior which is changeable as the circumstance of the foodservice industry changes.

  • PDF