• Title/Summary/Keyword: prism type

Search Result 102, Processing Time 0.033 seconds

An Experimental Study on the Replication Ratio of Micro Patterns of 7 inch LGP using Injection/Compression and RHCM (사출/압축 및 RHCM 기술이 7인치 도광판 마이크로 패턴 전사성에 미치는 영향에 대한 실험적 연구)

  • Cho, S.W.;Kim, J.S.;Hwang, C.J.;Yoon, K.H.;Kang, J.J.
    • Transactions of Materials Processing
    • /
    • v.20 no.1
    • /
    • pp.11-16
    • /
    • 2011
  • Recently, according to the rapid development of display, many display applications, such as, cellular phone, navigation, monitor and LCD TV have been changed from CRT type to LCD type. BLU(Back Light Unit) is one of main parts in LCD unit and generally, it consists of a light source, a reflective sheet, a LGP(Light Guide Plate), a diffuser sheet, and two prism sheets. The most important component of BLU is a light guide plate, which diffuses the input light to the TFT-LCD module uniformly. The LGP is usually made by injection molding process, and it has numerous optical micro patterns on the surface. In the present study the micro-patterned stamper which has cylindrical shape was fabricated by using the UV-LiGA process. And the replication characteristics have been compared among three different kinds of injection molding process; general injection molding, injection/compression molding and RHCM(Rapid Heating and Cooling Molding). Average replication ratios of CIM and ICM were 19.1% and 64.6%, respectively. On the other hand, the average replication ratio of RHCM process showed the higher value of 98.4% among these. It show that maintaining the mold surface above $T_g$ could increase the replication ratio of micro patterns substantially.

Effects of metal surface grinding at the porcelain try-in stage of fixed dental prostheses

  • Kilinc, Halil Ibrahim;Kesim, Bulent;Gumus, Hasan Onder;Dincel, Mehmet;Erkaya, Selcuk
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.317-324
    • /
    • 2014
  • PURPOSE. This study was to evaluate the effect of grinding of the inner metal surface during the porcelain try-in stage on metal-porcelain bonding considering the maximum temperature and the vibration of samples. MATERIALS AND METHODS. Ninety-one square prism-shaped ($1{\times}1{\times}1.5mm$) nickel-chrome cast frameworks 0.3 mm thick were prepared. Porcelain was applied on two opposite outer axial surfaces of the frameworks. The grinding was performed from the opposite axial sides of the inner metal surfaces with a low-speed handpiece with two types of burs (diamond, tungsten-carbide) under three grinding forces (3.5 N, 7 N, 14 N) and at two durations (5 seconds, 10 seconds). The shear bond strength (SBS) test was performed with universal testing machine. Statistical analyzes were performed at 5% significance level. RESULTS. The samples subjected to grinding under 3.5 N showed higher SBS values than those exposed to grinding under 7 N and 14 N (P<.05). SBS values of none of the groups differed from those of the control group (P>.05). The types of bur (P=.965) and the duration (P=.679) did not affect the SBS values. On the other hand, type of bur, force applied, and duration of the grinding affected the maximum temperatures of the samples, whereas the maximum vibration was affected only by the type of bur (P<.05). CONCLUSION. Grinding the inner metal surface did not affect the metal-porcelain bond strength. Although the grinding affected the maximum temperature and the vibration values of the samples, these did not influence the bonding strength.

Comparison of Binocular Function and Surgical Outcomes of Tenacious Proximal Fusion and High Accommodative Convergence/Accommodation Ratio Types of Intermittent Exotropia

  • Park, Jun Woo;Lee, Soo Jung
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.483-487
    • /
    • 2018
  • Purpose: To compare the characteristics and surgical outcomes in patients with tenacious proximal fusion (TPF) and high accommodative convergence/accommodation ratio (AC/A) types of intermittent exotropia. Methods: This study retrospectively enrolled 40 patients with intermittent exotropia, 23 with TPF and 17 with high AC/A. Binocular function was evaluated by Worth's 4-dot test. Patients underwent lateral rectus recession, and surgical outcomes were compared. Surgical success was defined as less than ${\pm}10$ prism diopters (PD) at 12 months postoperatively. Results: The proportion of diplopia at near, evaluated by Worth's 4-dot test, was significantly higher in patients with high AC/A than in those with TPF (35.3% vs. 4.3%, p = 0.029). The mean preoperative angles of deviation in TPF and high AC/A types were $28.3{\pm}4.4$ and $28.8{\pm}4.5PD$ at distances, and $14.7{\pm}4.2$ and $15.1{\pm}4.1PD$ at near. Twelve months after surgery, the mean angles of deviation in TPF and high AC/A types were $2.9{\pm}9.8$ and $1.2{\pm}9.6PD$, respectively, at distance and $1.7{\pm}7.7$ and $-1.3{\pm}11.3PD$ at near. The surgical success rates were similar in the TPF and high AC/A types (74.0% vs. 64.7%). Five (21.7%) patients with TPF and 2 (11.8%) with high AC/A type experienced recurrence, with consecutive esotropia occurring in 1 (4.3%) patient with TPF and 4 (23.5%) patients with high AC/A. Conclusions: The proportion of diplopia at near was higher in patients with high AC/A type than in those with TPF intermittent exotropia. However, the surgical success rates were not significantly different between the types.

Genetic Polymorphism in Corticotropin-releasing Hormone Receptor Type-1 in Preeclamptic Korean Women

  • Lim, Ji-Hyae;Kim, Shin-Young;Park, So-Yeon;Kim, Do-Jin;Kim, Mi-Jin;Ahn, Hyun-Kyong;Han, Jung-Yeol;Kim, Moon-Young;Park, Hyun-Young;Lee, Kwang-Soo;Kim, Young-Ju;Ryu, Hyun-Mee
    • Journal of Genetic Medicine
    • /
    • v.8 no.2
    • /
    • pp.113-118
    • /
    • 2011
  • Purpose: Placental corticotropin-releasing hormone receptor type 1 (CRHR1) expression is reduced in pregnancies with abnormal placental function such as preeclampsia (PE), and the levels and/or function of CRHR1 are genetically influenced. The aim of this study was to investigate the association between the c.33+8199C>T polymorphism in the CRHR1 gene and PE in a Korean population. Materials and Methods: Using a case-control design, the association between the CRHR1 polymorphism and the risk of PE was investigated in 203 individuals with PE and 211 normotensive controls. Genotypes were determined using a SNapShot kit and an ABI Prism 3100 Genetic analyzer. Results: Genotypes and allele frequencies for the CRHR1 polymorphism did not differ between PE and normotensive pregnancies. The variant T allele was more frequent than the ancestral C allele in both of the groups and was more frequent in the controls than in the cases. In risk analysis for PE, there was not an increased risk of preeclampsia in subjects who were concomitant homozygous rare allele genotypes (CC) (OR, 0.3; P=0.15) or heterozygous rare allele genotypes (TC) (OR, 0.8; P=0.29). There were no differences in the complications of PE such as severity or preterm delivery in patients with the CRHR1 polymorphism. Conclusion: Our findings indicate that the CRHR1 polymorphism was not associated with PE in the present Korean study group.

THE EFFECT OF ETCHING TIME ON THE PATTERN OF ACID ETCHING ON THE ENAMEL OF PRIMARY TEETH (산부식 시간에 따른 유전치 법랑질의 부식 유형에 관한 연구)

  • Choi, Su-Mi;Choi, Young-Chul;Park, Jae-Hong;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.437-445
    • /
    • 2008
  • The presence of a "prismless" layer on the enamel surface particularly on deciduous teeth has been reported by a number of workers. This structure, which appears to lack the normal prism delineations, could interfere with tag formation and hence, reduce bonding to such surfaces. The purpose of this study was to investigate the relationship of etching times on the effect of acid etching on primary enamel with respect to the quality of etching patterns. Labial surfaces of 32 extracted or exfoliated caries-free primary anterior teeth were used. 35% phosphoric acid gel was used only cervical regions of labial surfaces for each etching time group, 15, 30, 45 and 60 seconds. The surfaces were then washed with water for 20 seconds and dried with air spray for 20 seconds. 1. The Type 3 is 75% when the 15 seconds acid etching time was used. 2. The Type 1 is 38% and Type 2 is 75% when the 30 and 45 seconds acid etching time was used. 3. The Type 1 is 25% and Type 2 is 75% when the 60 seconds acid etching time was used. 4. An etching time of 60 seconds produced a constant and regular etching pattern. 5. There is a significant difference between the groups with respect to the patterns of etch achieved(p<0.05). 6. We confirmed that the acid induced patterns(type 1, 2) became more pronounced when the application time increased(p<0.05). $45{\sim}60$ seconds was the optimal time for etching on the primary enamel.

  • PDF

Study on Polarization Characteristics of Optical Device and Improvement of Measurement Precision of Normal Incidence Ellipsometer for Measuring Optical Anisotropy of a Micro Spot (미소면적 광학이방성 정밀 측정을 위한 수직반사형 타원계의 광소자 편광특성 및 측정정밀도 향상 연구)

  • Lyum, Kyoung Hun;Park, Sang Uk;Seo, Young Jin;Lee, Min Ho;Kim, Woong Ki;Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.6
    • /
    • pp.274-280
    • /
    • 2012
  • A normal incidence ellipsometer is fabricated to measure the optical anisotropy of a small spot whose diameter is less than $8.0{\mu}m$, by adding a beam splitter and a prism to the conventional rotating analyzer type ellipsometer. The polarizing actions of the added optical components are calibrated to improve the accuracy of the anisotropy measurement. The standard deviation of the optical anisotropy factor decreased to 0.00083, and the variation of the optical anisotropy factor of rutile versus sample azimuth angle variation also decreased to 0.015, after adoption of a non-polarizing beam splitter and a quarter wavelength phase retarder, followed by removal of the optical fiber and a careful choice of measurement wavelength.

Mechanism of Micro-V Grooving with Single Crystal Diamond Tool (단결정 다이어몬드 공구를 이용한 Micro-V 홈 가공기구)

  • Park D.S.;Seo T.I.;Kim J.K.;Seong E.J.;Han J.Y.;Lee E.S.;Cho M.W.;Choi D.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1223-1227
    • /
    • 2005
  • Fine microgroove is the key component to fabricate micro-grating, micro-grating lens and so on. Conventional groove fabrication methods such as etching and lithography have some problems in efficiency and surface integrity. This study deals with the creation of ultra-precision micro grooves using non-rotational diamond tool and CNC machining center. The shaping type machining method proposed in the study allows to produce V-shaped grooves of $40\mu{m}$ in depth with enough dimensional accuracy and surface. For the analysis of machining characteristics in micro V-grooving, three components of cutting forces and AE signal are measured and processed. Experimental results showed that large amplitude of cutting forces and AE appeared at the beginning of every cutting path, and cutting forces had a linear relation with the cross-sectional area of uncut chip thickness. From the results of this study, proposed micro V-grooving technique could be successfully applied to forming the precise optical parts like prism patterns on light guide panel of TFT-LCD.

  • PDF

Screening Strabismus of Elementary School (초등학생의 사시에 관한 연구)

  • Kim, Chang Sik;Lee, Hak Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.73-76
    • /
    • 1999
  • Screening of strabismus was followed in 1306 healthy elementary school students from 8 to 13 years old. The cover-uncover test with M1N GLASSES was used to screen strabismus for all of students and then we examined abnormal students by the prism cover test. Finally 16 students were strabismus. So the cover-uncover test with MIN GLASSES was a good method to screen strabismus because of easy and simple testing. The number of strabismus was 16 patients who consisted in from 10 to 13 years old, and girls(2.4%) was 3 times more than boys(0.9%). The type of 16 strabismus was only heterophoria which consisted in 8 patients of exophoria, 7 patients of esophoria and 1 patient of hyperphoria. So the rate of exophoria and esophoria was almost same. 3 patients was ametropic amblyopia by testing visual acuity, and all of patients were normal color vision by color testing.

  • PDF

A Multi-Service MAC Protocol in a Multi-Channel CSMA/CA for IEEE 802.11 Networks

  • Ben-Othman, Jalel;Castel, Hind;Mokdad, Lynda
    • Journal of Communications and Networks
    • /
    • v.10 no.3
    • /
    • pp.287-296
    • /
    • 2008
  • The IEEE 802.11 wireless standard uses the carrier sense multiple access with collision avoidance (CSMA/CA) as its MAC protocol (during the distributed coordination function period). This protocol is an adaptation of the CSMA/CD of the wired networks. CSMA/CA mechanism cannot guarantee quality of service (QoS) required by the application because orits random access method. In this study, we propose a new MAC protocol that considers different types of traffic (e.g., voice and data) and for each traffic type different priority levels are assigned. To improve the QoS of IEEE 802.11 MAC protocols over a multi-channel CSMA/CA, we have developed a new admission policy for both voice and data traffics. This protocol can be performed in direct sequence spread spectrum (DSSS) or frequency hopping spread spectrum (FHSS). For voice traffic we reserve a channel, while for data traffic the access is random using a CSMA/CA mechanism, and in this case a selective reject and push-out mechanism is added to meet the quality of service required by data traffic. To study the performance of the proposed protocol and to show the benefits of our design, a mathematical model is built based on Markov chains. The system could be represented by a Markov chain which is difficult to solve as the state-space is too large. This is due to the resource management and user mobility. Thus, we propose to build an aggregated Markov chain with a smaller state-space that allows performance measures to be computed easily. We have used stochastic comparisons of Markov chains to prove that the proposed access protocol (with selective reject and push-out mechanisms) gives less loss rates of high priority connections (data and voices) than the traditional one (without admission policy and selective reject and push-out mechanisms). We give numerical results to confirm mathematical proofs.

Stress-Free Pyrex-Based Optical Waveguide for Planar Lightwave Circuits on Silicon Substrate (실리콘 기판의 광집적회로를 위한 Pyrex 무응력 도파박막)

  • 문형명;정형곤;이용태;김한수;전영윤;정석종;윤선현;이형종
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.156-161
    • /
    • 1998
  • We developed aerosol flame deposition method and made stress-free Pyrex-based optical waveguide on silicon substrate using this method. Zr is doped to control the refractive index of Pyrex waveguide layers. The refractive index of the film changes from 1.460 to 1.475 as the content of Zr changes from 0 to 3 wt%. Er is doped to see the possibility of applying this Pyrex waveguide as PLC-type (Planar Lightwave Circuit) optical amplifier. The refractive index of the film changes from 1.460 to 1.465 as the content of Zr changes from 0 to 1 wt%. Light launching using a prism coupler to the fabricated waveguide showed good quality for application to PLC. The polarization dependence of refractive-index of the Pyrex film is measured to be less than $2{\times}10^{-4}$.

  • PDF