• Title/Summary/Keyword: primary loading

Search Result 366, Processing Time 0.027 seconds

Estimation of BOD Loading of Diffuse Pollution from Agricultural-Forestry Watersheds (농지-임야 유역의 비점원 발생 BOD 부하의 추정)

  • Kim, Geonha;Kwon, Sehyug
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.617-623
    • /
    • 2005
  • Forestry and agricultural land uses constitute 85% of Korea and these land uses are typically mixed in many watersheds. Biological Oxygen Demand (BOD) concentration is a primary factor for managing water qualities of the water resources in Korea. BOD loadings from diffuse sources, however, not well monitored yet. This study aims to assess BOD loadings from diffuse sources and their affecting factors to conserve quality of water resources. Event Mean Concentration (EMC) of BOD was calculated based on the monitoring data of forty rainfall events at four agricultural-forestry watersheds. Exceedence cumulative probability of BOD EMCs were plotted to show agricultural activities in a watershed impacts on the magnitude of EMCs. Prediction equation for each rainfall event was proposed to estimate BOD EMCs: $EMC_{BOD}(mg/L)=EXP(0.413+0.0000001157{\times}$(discharged runoff volume in $m^3$)+0.018${\times}$(ratio of agricultural land use to total watershed area).

Shear Behavior of Wide Beam-Column Joints with Slab (슬래브가 있는 넓은 보-기둥 접합부의 전단거동)

  • 안종문;최종인;신성우;이범식;박성식;양지수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.157-162
    • /
    • 2003
  • An experimental investigation was conducted to study the behavior of high-strength RC wide beam-column joints with slab subjected to reversed cyclic loads under constant axial load. Six half scale interior wide beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including three specimens without slab and three specimens with slab. The primary variables were compressive strength of concrete($f_ck$=285, 460kgf/$cm^2$), the ratio of the column-to-beam flexural capacity($M_r$=$\Sigma M_c / \Sigma M_b$ ; 0.77 -2.26), extended length of the column concrete($l_d$ ; 0, 12.5, 30cm), ratio of the column-to-beam width(b/H ; 1.54, 1.67). Test results are shown that (1) the behavior of specimen using high-strength concrete satisfied for required minimum ductile capacity according to increase the compressive strength, (2) the current design code and practice for interior joints(type 2) are apply to the wide beam-high strength concrete column.

  • PDF

Cell Search In Asynchronous W-CDMA System (비동기식 W-CDMA 시스템의 셀 탐색(Cell Search)에 관한연구)

  • 김강온;김병학;김철성
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.325-328
    • /
    • 2001
  • In this work, Cell search which is one of the important abilities of W-CDMA system in Reyleigh s fading channel is studied by using Cell Searcher of asynchronous IMT-2000 system(3GPP) and Cell - search simulation. For the methods of cell search to optimize codes, three stages are considered: 1) slot synchronization, 2) frame synchronization, and 3) scrambling code identification. It is found that key system parameters such as Primary Synchronization Channel (P-SCH), Secondary L Synchronization Channel(S-SCH), and Common Pilot Channel (CPCH) loading factor are optimized. It is noted that the smaller Optimal threshold value, the larger SNR of the received singnal. Therefore, It is important that the optimal threshold value is selected in the region of SNR

  • PDF

Derivation of TMA Slagging Indices for Blended Coals

  • Park, Ho Young;Baek, Se Hyun;Kim, Hyun Hee;Park, Sang Bin
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.127-131
    • /
    • 2017
  • The present paper describes the slagging field data obtained with the one-dimensional process model for the 500 MW tangentially coal fired boiler in Korea. To obtain slagging field data in terms of thermal resistances [$m^2{\cdot}^{\circ}C/kW$], a number of plant data were collected and analyzed with the one-dimensional modelling software at 500 MW full load. The slagging field data for the primary superheater were obtained for six coal blends, and compared with two TMA (Thermo-Mechanical analyzer) slagging indices and the numerical slagging index, along with the conventional slagging indices which were modified with the ash loading. The advanced two TMA indices for six blended coals give a good slagging tendency when comparing them with the slagging field data, while the modified conventional slagging indices give a relatively poor agreement.

V-Factor Estimation Under Thermal and Mechanical Stress for Circumferentially Cracked Cylinder (열하중 및 기계하중이 작용하는 원주 방향 균열 배관에 대한 V-계수 평가)

  • Song, Tae-Kwang;Oh, Chang-Kyun;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1123-1131
    • /
    • 2008
  • This paper provides V-factor estimation under combined mechanical and thermal load for circumferential cracks. Results are based on finite element analyses and effect of types and magnitudes of the thermal stress, crack geometry, the loading mode and plastic strain hardening on variations of the V-factor are investigated. The results of finite element analyses are compared with R6 values. As a result, it is shown that R6 gives generally conservative results. The conservatism is especially increased for the combination of large mechanical and thermal load. As a result, new estimation method which uses failure assessment line in R6 is proposed for V-factor and gives less conservative results.

The Optimum Design of Internal Pipes for LNG Storage Tank (LNG 저장탱크용 관통 파이프의 설계 최적화 연구)

  • Seo, H.S.;Yang, Y.M.;Hong, S.H.;Kim, H.S.;Kim, Y.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.776-781
    • /
    • 2001
  • Internal pipes technology for LNG Storage tank developed because of the perceived safety risk of having an opening near the base of the shell. This is because the shell at this point is the most highly stressed component of the primary containment. other, secondary, problems arise because the movement of the tank in this region is also at a maximum. This requires the use of bellows either in the interspace or on the outside of the outer tank. Therefore the internal pipe, through the roof, solves these problems. The loading conditions calculated from design concept are then used to perform a pipe stress analysis. As well as determining the stresses in the internal pipe and checking against allowable stress, it determines the reaction forces at the support positions.

  • PDF

An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram (과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘)

  • 허정용;김철환
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.161-167
    • /
    • 2004
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk lot mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel Zone 3 scheme based on combining the steady-state components (i.e. 60Hz) and the transient components (TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

A Study on the Prediction of Fatigue Crack Initiation Life of Hole Expansion Plate (홀 확장 판재의 피로균열 발생수명 예측에 관한 연구)

  • 이동석;이준현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.2
    • /
    • pp.129-135
    • /
    • 2003
  • The fatigue life of a structure can be enhanced by improving the mechanical and metallurgical aspects to strengthen the material around regions of high stress. Coldworking of holes in structures is one of the mechanical methods of strengthening material. The material for this research is A12024-T351 which is used for the primary member or aircraft. Specimens were tested under constant amplitude loading and residual stresses measured by X-ray diffraction technique. Fatigue crack initiation life was evaluated by a strain-life equation which was considered initial residual stress and residual stress relaxation exponent as a function of the strain amplitude. The predictions on fatigue crack initiation life were compared with experimental results. A wide range of discrepancies between them was found.

CORRECTION TECHNIQUES OF MASS-LOADING EFFECTS OF TRANSDUCERS IN MODAL TESTING

  • Guoyi Ji;Chung, Won-Jee;Lee, Choon-Man;Park, Dong-Keun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.188-188
    • /
    • 2004
  • Modal testing and analysis is a primary tool for obtaining reliable models to represent the dynamics of structures. When a structure is tested in order to collect measured data in modal testing, we usually use attached accelerometers to pick up the response data. Change in modal parameters due to the mass of transducers in modal testing is a well-known problem. The disadvantages are the shift of measured modal frequencies and the change of modal shapes, which can cause inaccurate results in further analysis. Modal analysis methods in frequency domain are based on a set of measured frequency response functions(FRF).(omitted)

  • PDF

A Study on the Dynamic Behaviors of a Shipping Container Under Drop Impact Loading (낙하충격하중을 받는 방사성물질 수송용기의 동적거동에 관한 연구)

  • 이영신;김용재
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.2805-2816
    • /
    • 1994
  • This paper describes dynamic finite element analyses performed to study the dynamic behaviors of a shipping container under the impact onto rigid target due to the accidental fall from the hight of 9 m. Using two and three dimensional techniques, the shipping container which gave the maximum damage, ten different drop orientations are considered ; at intervals of $5^{\circ}$ from $45^{\circ}$ to $90^{\circ}$ According to the present results, the orientation of the shipping container which gave the maximum damage is $85^{\circ}$ from horizontal for oblique drop in the primary impact. In the optimal design of the shipping container, the impact limiter material must be considered importantly because it's proper selection affects the weight and the manufacturing cost of the shipping container. The analysis of the shipping container in this paper demonstrated that the shipping container is structurally sound relative to the regulatory drop test requirements.