• Title/Summary/Keyword: pressure ratio

Search Result 5,691, Processing Time 0.052 seconds

Self-management levels of diet and metabolic risk factors according to disease duration in patients with type 2 diabetes

  • Cho, Sukyung;Kim, Minkyeong;Park, Kyong
    • Nutrition Research and Practice
    • /
    • v.12 no.1
    • /
    • pp.69-77
    • /
    • 2018
  • BACKGROUND/OBJECTIVES: Metabolic risk factors should be managed effectively in patients with type 2 diabetes mellitus (T2DM) to prevent or delay diabetic complications. This study aimed to compare the self-management levels of diet and metabolic risk factors in patients with T2DM, according to the duration of illness, and to examine the trends in self-management levels during the recent decades. SUBJECTS/METHODS: Data were collected from the Korea National Health and Nutrition Examination Surveys (KNHANES, 1998-2014). In our analysis, 4,148 patients with T2DM, aged ${\geq}30years$, were categorized according to the duration of their illness (< 5 years, 5-9 years, and ${\geq}10years$). Demographic and lifestyle information was assessed through self-administered questionnaires, and biomarker levels (e.g., fasting glucose level, blood pressure, or lipid level) were obtained from a health examination. Dietary intake was assessed by a 24-recall, and adherence level to dietary guidelines (meal patterns and intake levels of calories, carbohydrates, vegetable/seaweed, sodium, and alcohol) were assessed. Multivariable generalized linear regression and unconditional logistic regression models were used to compare the prevalence rates of hyperglycemia, dyslipidemia, and hypertension according to the duration of patients' illness, accounting for the complex survey design of the KNHANES. RESULTS: In the multivariable adjusted models, patients with a longer duration (${\geq}10years$) of T2DM had a higher prevalence of hyperglycemia than those with a shorter duration of T2DM (< 5 years) (odds ratio 2.20, 95% confidence interval 1.61-3.01, P for trend < 0.001). We did not observe any associations of disease duration with the prevalence of hypertension and dyslipidemia. In addition, the adherence levels to dietary recommendations did not significantly differ according to disease duration, except adherence to moderate alcohol consumption. There were significant decreasing trends in the prevalence of hyperglycemia in patients with a duration of illness ${\geq}10years$ (P for trend = 0.004). CONCLUSION: Although the proportion of patients with adequate control of glucose levels has improved in recent decades, poorer self-management has been found in those with a longer disease duration. These findings suggest the need for well-planned and individualized patient education programs to improve self-management levels and quality of life by preventing or delaying diabetic complications.

Characteristics of Dental Emergency Patients at Busan Paik Hospital (부산백병원 응급실로 내원한 치과 응급환자에 대한 임상적 연구)

  • Kim, So-Hyun;Kim, Do-Young;Baek, Joon-Seok;Jung, Tae-Young;Park, Sang-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.58-64
    • /
    • 2012
  • Purpose: Dental emergencies vary from toothaches to oral and maxillofacial traumas. Because the number of dental emergency cases has increased recently, we analyzed characteristics of patients seen during the last 2 years, in an effort to find a trend. Methods: This study was carried out with emergency room patients visiting the Department of Oral and Maxillofacial Surgery from 2009 to 2010. Results: The total number of patients studied was 1,162; the ratio of males to females was 1.73:1. The most frequent age group was 0 to 9 years, followed by 20 to 29 years. Trauma (58.7%) was the most frequent cause followed by acute toothache, oral hemorrhage, infection, and temporomandibular (TMJ) disorder. In the trauma group, injuries of soft tissue and alveolus were prevalent. The most common causes of soft tissue injury were falls, safety violations and assault. The highest incidence of emergencies was seen in patients 0 to 9 years old (41.8%). The most common causes of jaw fracture were falls, assaults, and traffic accidents in that order. In the acute toothache group, most patients had pulpitis (41.2%). In the infection group, most had buccal space abscesses (40.0%). In the hemorrhage group, post-operative bleeding cases (80.5%) were the majority, and hemostasis was obtained mostly by pressure dressings. For the TMJ disorder group, masticatory muscle disorder (65.4%) was more common than TMJ dislocation. Conclusion: In this study, trauma was the most frequent reason for patients who visited the emergency room. However, acute toothache, hemorrhage, infection and TMJ disorders were also seen frequently. Dental emergency patients could be better treated by understanding patterns of dental emergencies and performing proper diagnoses.

Investigation on the Performance of Special Purpose Automotive Air-Conditioning System Using Dual Refrigeration Cycle (듀얼 냉동사이클을 이용하는 특수목적 자동차용 에어컨 시스템의 냉방성능에 관한 연구)

  • Seo, Jae-Hyeong;Bang, You-Ma;Lee, Moo-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.213-220
    • /
    • 2016
  • The objective of this study is to investigate the cooling performance of an air-conditioning system for a special purpose vehicle under tropical and severe weather conditions. In order to evaluate and compare the cooling performances, the dual refrigeration cycle using R-134a was tested on a special purpose vehicle with various refrigerant charge amounts and indoor temperatures. The cycle was tested considering indoor cooling speed and compression ratio (discharge pressure), and was optimized at the refrigerant charge amount of 1.5 kg and outdoor temperature of $40.0^{\circ}C$. The time to reach indoor temperature of $15.0^{\circ}C$ increased by 86.5% and 38.1%, at the indoor temperatures from $25.0^{\circ}C$ to $32.5^{\circ}C$ and from $32.5^{\circ}C$ to $40.0^{\circ}C$, respectively. In addition, with the increase in indoor temperature from $25.0^{\circ}C$ to $40.0^{\circ}C$, the cooling capacity increased by 7.3%, from 19.1 kW to 20.5 kW, but decreased by 7.0% from 4.67 to 5.1.

Electrical Characteristic of IGZO Oxide TFTs with 3 Layer Gate Insulator

  • Lim, Sang Chul;Koo, Jae Bon;Park, Chan Woo;Jung, Soon-Won;Na, Bock Soon;Lee, Sang Seok;Cho, Kyoung Ik;Chu, Hye Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.344-344
    • /
    • 2014
  • Transparent amorphous oxide semiconductors such as a In-Ga-Zn-O (a-IGZO) have advantages for large area electronic devices; e.g., uniform deposition at a large area, optical transparency, a smooth surface, and large electron mobility >10 cm2/Vs, which is more than an order of magnitude larger than that of hydrogen amorphous silicon (a-Si;H).1) Thin film transistors (TFTs) that employ amorphous oxide semiconductors such as ZnO, In-Ga-Zn-O, or Hf-In-Zn-O (HIZO) are currently subject of intensive study owing to their high potential for application in flat panel displays. The device fabrication process involves a series of thin film deposition and photolithographic patterning steps. In order to minimize contamination, the substrates usually undergo a cleaning procedure using deionized water, before and after the growth of thin films by sputtering methods. The devices structure were fabricated top-contact gate TFTs using the a-IGZO films on the plastic substrates. The channel width and length were 80 and 20 um, respectively. The source and drain electrode regions were defined by photolithography and wet etching process. The electrodes consisting of Ti(15 nm)/Al(120 nm)/Ti(15nm) trilayers were deposited by direct current sputtering. The 30 nm thickness active IGZO layer deposited by rf magnetron sputtering at room temperature. The deposition condition is as follows: a rf power 200 W, a pressure of 5 mtorr, 10% of oxygen [O2/(O2+Ar)=0.1], and room temperature. A 9-nm-thick Al2O3 layer was formed as a first, third gate insulator by ALD deposition. A 290-nm-thick SS6908 organic dielectrics formed as second gate insulator by spin-coating. The schematic structure of the IGZO TFT is top gate contact geometry device structure for typical TFTs fabricated in this study. Drain current (IDS) versus drain-source voltage (VDS) output characteristics curve of a IGZO TFTs fabricated using the 3-layer gate insulator on a plastic substrate and log(IDS)-gate voltage (VG) characteristics for typical IGZO TFTs. The TFTs device has a channel width (W) of $80{\mu}m$ and a channel length (L) of $20{\mu}m$. The IDS-VDS curves showed well-defined transistor characteristics with saturation effects at VG>-10 V and VDS>-20 V for the inkjet printing IGZO device. The carrier charge mobility was determined to be 15.18 cm^2 V-1s-1 with FET threshold voltage of -3 V and on/off current ratio 10^9.

  • PDF

Simulation on Concentration of CH4 Using Hollow Fiber Membrane Permeator with Countercurrent Flow (향류 흐름 중공사 분리막의 메탄 농축 수치해석)

  • Seo, Yeonhee;Lee, Seungmin;Park, Sungeun;Jung, Woojin;Kim, Jeonghoon;Lee, Yongtaek
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.223-230
    • /
    • 2014
  • A numerical analysis was performed for concentration of methane from the biogas using a polysulfone hollow fiber membrane permeator. Governing equations were derived for the countercurrent flow and numerically solved by using the Compaq Visual Fortran 6.6 software. When the methane mole fraction of feed was 0.5, the mole fraction of retentate increased from 0.5 to 0.8; the normalized retentate flow rate to the feed flow rate decreased from 1.0 to 0.57 at the given typical operating condition as the feed gas flowed from the inlet to the outlet of the membrane. As the methane mole fraction of feed was changed to 0.9, the methane mole fraction of retentate became 0.93 and the normalized retentate flow rate was changed to 0.91. When the pressure ratio of the permeate to the feed was varied from 0.33 to 0.17, there was a little difference in the methane mole fraction of retentate for the low stage cut of 0.1, whereas there was an significant increment for the high stage cut of 0.3. The retentate methane mole fraction remained relatively high despite the change of a stage cut as the area of the membrane increased from $1.14m^2$ to $2.57m^2$.

A Study on the Annealing Effect of SnO Nanostructures with High Surface Area (높은 표면적을 갖는 SnO 나노구조물의 열처리 효과에 관한 연구)

  • Kim, Jong-Il;Kim, Ki-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.536-542
    • /
    • 2018
  • Tin dioxide, $SnO_2$, is a well-known n-type semiconductor that shows change in resistance in the presence of gas molecules, such as $H_2$, CO, and $CO_2$. Considerable research has been done on $SnO_2$ semiconductors for gas sensor applications due to their noble property. The nanomaterials exhibit a high surface to volume ratio, which means it has an advantage in the sensing of gas molecules. In this study, SnO nanoplatelets were grown densely on Si substrates using a thermal CVD process. The SnO nanostructures grown by the vapor transport method were post annealed to a $SnO_2$ phase by thermal CVD in an oxygen atmosphere at $830^{\circ}C$ and $1030^{\circ}C$. The pressure of the furnace chamber was maintained at 4.2 Torr. The crystallographic properties of the post-annealed SnO nanostructures were investigated by Raman spectroscopy and XRD. The change in morphology was confirmed by scanning electron microscopy. As a result, the SnO nanostructures were transformed to a $SnO_2$ phase by a post-annealing process.

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

Evaluation of Binder jetting 3D Printed Specimens Using Vacuum Impregnation (진공함침을 적용한 바인더젯 3D 프린팅 출력물의 성능 평가)

  • Park, Kwang-Min;Park, Su-Hyeon;Lee, Jun;Lee, Bong-Chun;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.103-110
    • /
    • 2020
  • This study examined the applicability of the vacuum impregnation post-processing to enhance the strength of binder jet 3D printed output. In addition, permeability, bulk density, and compressive strength of 10 mm, 20 mm, 30 mm, and 40 mm cubic specimens were examined to check the strength limit depending on the 3D prined output size. In result, as the maximum pressure increased, the post-processing storage solution permeated to the inside of the 3D printed sample and thus the permeation area ratio was improved. The compressive strength and the permeation area indicate the correlation between the exponential function of the adjusted R-square factor 0.992. In addition, the bulk density was increased, which can be inferred as the post-processing solution permeated to the inside. In conclusion, in order to enhance the compressive strength of the binder jet 3D printed output, it is essential to permeate the post-processing solution to the inside of the output, and vacuum impregnation can be proposed as an effective method.

Patent Technologies for Reducing Micro-Dust (미세먼지 저감을 위한 특허기술들)

  • Cho, Taejun;Kim, Tae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.9-14
    • /
    • 2020
  • Four developed patents have applied for a new type of Composite Cyclone Scrubber followed by the previous research (Cho and Kim, 2017), including dust reducing fan with filters. Regarding target installation and maintenance cost, 64% reduction for investment costs (6.2 billion won vs. 17 billion won) compared to existing road pollution reduction system, while social benefit costs increase by 43% compared to existing road pollution reduction measures (72.6 billion won vs. 50.8 billion won). The composition of the device is an air blower type spiral guide vane, and an injection pressure collecting dust efficiency. A nozzle varies Injection angle and contact range, spray liquid species (waterworks, salty water). The proposed patent tests are circulation water Time-by-Time Spray and collected 41.4% more increased micro dust since the sprayed water meets contaminated gas due to the 45° degree colliding, which is 141% increased conventional dust collector. (Ratio of collection over 85%). As regards the source of collection liquid, circulated rainwater and well water, we expect a huge amount of energy and economically saved eco-friendly system in our patent. Finally, the guided vane and metal filter reduced over 90% micro-dust, while sprayed water cleans the vane and filters, resultantly minimizing the maintenance budget. The preliminary evaluations of the developed design make it possible to reduce not only cheaper maintenance budget due to the characteristic water spraying but the cost of water comes from mainly rain and underground.

Effect of 12-week Low Calorie Diet and Behavior Modification on the Anthropomeric Indices and Biochemical Nutritional Status of Obese Woman (12주 동안의 저열량식사와 행동수정요법이 비만여성의 체격지수와 생화학적 영양상태에 미치는 영향)

  • Son, Sook-Mee;Kim, Hee-Jun
    • Korean Journal of Community Nutrition
    • /
    • v.10 no.4
    • /
    • pp.525-535
    • /
    • 2005
  • This study was conducted to investigate the effect of a 3 week low calorie diet (LCD) and a 9 week of behavior modification (BM) program on the weight loss, mineral and vitamin status in 22 obese women. The subject were healthy, obese (PIBW> $120\%$) women aged 20 - 50 Yr and not taking any medications known to influence body composition, mineral or vitamin metabolism During the LCD program, subjects were provided commercial liquid formulas with 125 kcal per pack and were instructed to have a formula for replacement of one meal and at least one regular meal per day within the range of daily 800 - 1200 kcal intake. During the BM program the subjects weekly attended the group nutrition counseling session to encourage themselves to modify their eating behavior and spontaneously restrict their energy intakes. The BM program focused on stimulus control, control of portion sizes and modification of binge eating and other adverse habits. The initial mean energy intake of subjects was 2016.9 $\pm$ 129.8 kcal ($100.8\%$ of RDA) and dropped to 1276.5 $\pm$ 435.7 kcal at the end of a 3 week of LCD program and elevated to 1762 $\pm$ 329.3 kcal at the end of a 9 week of BM program. Carbohydrate, protein and fat intakes were significantly decreased at the end of the LCD but carbohydrate was the only macro nutrient that showed significant decrease (p < 0.05) at the end of the BM program compared to baseline. Calcium and iron intakes decreased significantly (p < 0.01, respectively) with no significant changes in other micronutrients at the end of the LCD. The mean weight of the subjects decreased from 73.8 $\pm$ 8.0 kg to 69.2 $\pm$ 7.7 kg with LCD and ended up with 67.7 $\pm$ 7.1 kg after 9 weeks of BM. The 3 weeks of LCD reduced most of the anthropometric indices such as BMI, PIBW, fat weight, wast-to-hip ratio and subscapular and suprailiac skinfold thickness. The 9 weeks of behavior modification showed slight change or maintenance of each anthropometric measurements. Weight loss and decreased WHR with the diet program induced significantly decreased systolic blood pressure. SGOT, SGPT and serum insulin levels with improved serum lipid profiles. Biochemical parameters related to iron status such as hemoglobin, hematocrit were significantly decreased (p < 0.01) at the end of the LCD. But their mean values were within normal range. The mean serum 25 (OH) vitamin $D_3$ level significantly increased after whole diet program. Serum folate level significantly decreased after 12 weeks of diet program. In conclusion 3 weeks of LCD brought 4.6 kg reduction in body weight without risk of iron, zinc or vitamin D deficiency and 9 weeks of the BM was effective to maintain nutritional status with slightly more weight reduction (1.5 kg). However calcium intake and serum folate should be monitored during the LCD and BM because of increased risk of deficiencies.