• Title/Summary/Keyword: prescriptive

Search Result 126, Processing Time 0.023 seconds

Consideration for AFRAMAX TANKER Applied Common Structural Rules (AFRAMAX TANKER의 CSR 적용에 대한 고찰)

  • Kim, Sung-In;Kim, Young-Nam;Kim, Gyeong-Rae
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2007.09a
    • /
    • pp.99-106
    • /
    • 2007
  • The IACS Common Structural Rules are to be applied for double hull tanker of more than 150m length with contracted after 1 April 2006. The objectives of the rules are to make more robust, safer ship and to ensure transparency of the technical background. In compliance of CSR, we had carried out prescriptive rules scantling determination and 3-D hold FE analysis of AFRAMAX TANKER. Prescriptive rules scantling determines the minimum required scantling, hull-girder longitudinal bending and shear strength, hull girder ultimate strength, local strength of plate and stiffener, strength of primary supporting member and fatigue assessment of the longitudinal stiffener end connections to the transverse bulkhead. 3-D hold FE analysis assesses the structural adequacy of the vessel's primary hull structure and major supporting members using yielding and buckling failure modes. So we could verify the strength assessment of AFRAMAX TANKER applied CSR.

  • PDF

Trends in Research on Caregivers Hospitalized Children in Korea-Focus on Knowledge Type (입원아동 보호자 대상 연구논문 분석-지식체 유형을 중심으로)

  • Kwon, In-Soo;Seo, Yeong-Mi;Kim, Ji-Youn
    • Child Health Nursing Research
    • /
    • v.18 no.3
    • /
    • pp.101-108
    • /
    • 2012
  • Purpose: This study was designed to analyze recent trends in research about caregivers of hospitalized children in Korea and to suggest future research directions in this area. Methods: Eighty one studies selected from http://www.kan.or.kr, www.childnursing.or.kr, www.riss4u.net, and www.ndsl.kr published from 1995 to 2011 were used. The analysis framework of concepts was derived from client domain (Kim, 2000) and knowledge type (Kim et al., 2004). Results: In terms of research design, nonexperimental studies (82.7%) were the most frequent, followed by experimental studies (14.8%) and qualitative studies (2.5%). Mothers were the most frequent caregivers, and hospitalization was the most frequent health problem of the children. In terms of categories of the concepts, 35 (39.3%) studies included essentialistic concepts like coping and adaptation, 15 (16.9%) studies included problematic concepts like anxiety and uncertainty, and 39 (43.8%) studies included health-care experiential concepts like educational needs and nursing needs. In term of knowledge types, there were 35 (39.3%) studies of the explanatory knowledge type, 44 (49.5%) descriptive ones, and 10 (11.2%) prescriptive ones. Conclusion: The results indicate that further research is necessary on problematic concepts and prescriptive knowledge types for child health nursing practice which will lead to expanding nursing knowledge.

Optimum location of second outrigger in RC core walls subjected to NF earthquakes

  • Beiraghi, Hamid;Hedayati, Mansooreh
    • Steel and Composite Structures
    • /
    • v.38 no.6
    • /
    • pp.671-690
    • /
    • 2021
  • Seismic responses of RC core wall with two outriggers are investigated in this study. In the models analyzed here, one of the outriggers is fixed at the top of the building and the second is placed at different levels along the height of the system. Each of the systems resulting from the placement of the outrigger at different locations is designed according to the prescriptive codes. The location of the outrigger changes along the height. Linear design of all the structures is accomplished by using prescriptive codes. Buckling restrained braces (BRBs) are used in the outriggers and forward directivity near fault and far fault earthquake record sets are used at maximum considered earthquake (MCE) level. Results from nonlinear time history analysis demonstrate that BRB outriggers can change the seismic responses like force distribution and deformation demand of the RC core-walls over the height and lead to the new plastic hinge arrangement over the core-wall height. Plasticity extension in the RC core wall occurs at the base as well as adjacent to the outrigger levels. Considering the maximum inter-story drift ratio (IDR) demand as an engineering parameter, the best location for the second outrigger is at 0.75H, in which the maximum IDR at the region upper the second outrigger level is approximately equal to the corresponding value in the lower region.

APPLICATION OF PERFORMANCED BASED DESIGN IN FIRE PROTECTION ENGINEERING

  • Cha, David S.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.423-438
    • /
    • 1997
  • Today's building and fire prevention codes are mostly prescriptive. Prescriptive codes are based on major fires in earlier years that created a need for specific building provision. These codes provide a minimum level of safety. As the general and engineering uses of computers have increased over the years, so has use of computers in the fire protection engineering. This has allowed fire protection engineers to develop alternative approaches to solve today's fire protection problems or to evaluate the performance of a specific fire safety goal. A performance based approach to building and fire codes involves the following: 1) identifying specific goals, such as, safely getting out of the building in 10 minutes, 2) obtain conceptual approval from authorities, 3) define performance level, 4) develop design solutions and identify tools such as, fire tests, models, or methods, to demonstrate that a design will meet the fire protection objective 5) test solutions, 6) present test method and results to the authorities. Some people in the fire protection community consider this to be nothing more than an intellectual exercise, while the others view it as a way to reduce expenses on large project$^4$ Others in fire protection community view this as a way to refine the design process to design fire protection systems to better protect the fire hazards. This paper will focus on application of these tools, specifically computer fire models, to actual cases such as: design of a smoke control system heat transfer analysis and egress of building occupants during potential fires.

  • PDF

Artificial Intelligence-Based Descriptive, Predictive, and Prescriptive Coating Weight Control Model for Continuous Galvanizing Line

  • Devraj Ranjan;G. R. Dineshkumar;Rajesh Pais;Mrityunjay Kumar Singh;Mohseen Kadarbhai;Biswajit Ghosh;Chaitanya Bhanu
    • Corrosion Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.228-234
    • /
    • 2024
  • Zinc wiping is a phenomenon used to control zinc-coating thickness on steel substrate during hot dip galvanizing by equipment called air knife. Uniformity of zinc coating weight in length and width profile along with surface quality are most critical quality parameters of galvanized steel. Deviation from tolerance level of coating thickness causes issues like overcoating (excess consumption of costly zinc) or undercoating leading to rejections due to non-compliance of customer requirement. Main contributor of deviation from target coating weight is dynamic change in air knives equipment setup when thickness, width, and type of substrate changes. Additionally, cold coating measurement gauge measure coating weight after solidification but are installed down the line from air knife resulting in delayed feedback. This study presents a coating weight control model (Galvantage) predicting critical air knife parameters air pressure, knife distance from strip and line speed for coating control. A reverse engineering approach is adopted to design a predictive, prescriptive, and descriptive model recommending air knife setups that estimate air knife distance and expected coating weight in real time. Implementation of this model eliminates feedback lag experienced due to location of coating gauge and achieving setup without trial-error by operator.

Quality Function deployment:Methods and modeling issues

  • 김광재
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1997.10a
    • /
    • pp.189-192
    • /
    • 1997
  • New product development is a complex managerial process which involves multiple functional groups, each with a different perspective. Quality function deployment (QFD) is a new product development process which stresses cross-functional integration. QFD provides a specific approach for ensuring quality through each stage of the product development and production process. This paper provides an overview of QFD including its concepts and methods, and then proposes an integrated approach to formulating and solving the QFD process. This paper also discusses issues associated with the prescriptive modeling of QFD.

  • PDF

Decision-making Process for Choosing Alternative Outbound Travel Product (해외여행상품 선택을 위한 의사결정 프로세스에 관한 연구)

  • Kang, Inwon;Park, Chanwook
    • Knowledge Management Research
    • /
    • v.10 no.3
    • /
    • pp.99-113
    • /
    • 2009
  • The goal of this article is to ascertain the factors that govern consumers' choosing to outbound travel product. The authors assess the consumers' travel product choosing processes with information search(internal knowledge, external information knowledge). alternative evaluation(perceived image, emotional experience, price acceptability, appeal, trust), and alternative choice(purchasing intention). Using data on Thailand travel product, the authors find considerable results and conclude by discussing prescriptive recommendations for the travel industry.

  • PDF

성능위주 방화설계의 세계적 흐름과 적용

  • 이수경
    • Bulletin of the Korean Institute for Industrial Safety
    • /
    • v.1 no.1
    • /
    • pp.21-27
    • /
    • 2001
  • 산업 발전과 인구의 급격한 증가에 따라 건축물은 고층화 및 인텔리젼트화 되어가면서, 화재로 인한 인적·물적 손실은 계속적으로 증가하고 있다. 따라서 과거보다 구체적이고 근본적인 대책의 마련이 필요하게 되었다. 현재의 소방시설의 설계는 사양중심(Prescriptive Based)의 체계로 되어 있다. 우리나라의 경우는 사양중심 체계로 되어있으나 외국에서의 공학적 도구와 연구를 바탕으로 하는 성능위주의 방화설계에 대한 연구가 시작되어 기존에 개발된 화재거동과 연기이동 및 피난의 소프트웨어를 이용하여 소방대상물의 열 분포, 연기이동, 피난특성, 발생열량 및 내화도 등을 분석함으로써 적합한 방화설계가 진행중이다.(중략)

  • PDF

Trends of Doctoral Dissertations in Nursing Science: Focused on Studies Submitted Since 2000 (간호학 박사학위 논문의 최근 탐구 경향: 2000년 이후 논문 분석)

  • Shin, Hyun-Sook;Sung, Kyung-Mi;Jeong, Seok-Hee;Kim, Dae-Ran
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.1
    • /
    • pp.74-82
    • /
    • 2008
  • Purpose: The purpose of the study was to identify the characteristics of doctoral dissertations in nursing science submitted since 2000. Method: Three-hundred and five dissertations of six schools of nursing published from 2000 to 2006 in Korea were analyzed with the categories of philosophy, method, body of knowledge, research design, and nursing domain, Result: In philosophy, 82% of all dissertations were identified as scientific realism, 15% were relativism, and 3% were practicism. Two-hundred and fifty dissertations (82%) were divided into a quantitative methodology and 55 dissertations (18%) were qualitative methodology. Specifically, 45% were experimental, 23% methodological, 13% survey and 17% qualitative designed researches. Prescriptive knowledge was created in 47% of dissertations, explanatory knowledge in 29%, and descriptive knowledge in 24%. Over 50% of all research was studied with a community-based population. In the nursing domain, dissertations of the practice domain were highest (48.2%). Conclusion: Dissertations since 2000 were markedly different from the characteristics of the previous studies (1982-1999) in the increase of situation-related, prescriptive and community-based population studies. A picture of current nursing science identified in this study may provide a future guideline for the doctoral education for nursing.

Some Considerations for the Fire Safe Design of Tall Buildings

  • Cowlard, Adam;Bittern, Adam;Abecassis-Empis, Cecilia;Torero, Jose L.
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.63-77
    • /
    • 2013
  • In any subject area related to the provision of safety, failure is typically the most effective mechanism for evoking rapid reform and an introspective assessment of the accepted operating methods and standards within a professional body. In the realm of tall buildings the most notable failures in history, those of the WTC towers, widely accepted as fire induced failures, have not to any significant extent affected the way they are designed with respect to fire safety. This is clearly reflected in the surge in numbers of Tall Buildings being constructed since 2001. The combination of the magnitude and time-scale of the WTC investigation coupled with the absence of meaningful guidance resulting from it strongly hints at the outdatedness of current fire engineering practice as a discipline in the context of such advanced infrastructure. This is further reflected in the continual shift from prescriptive to performance based design in many parts of the world demonstrating an ever growing acceptance that these buildings are beyond the realm of applicability of prescriptive guidance. In order for true performance based engineering to occur however, specific performance goals need to be established for these structures. This work seeks to highlight the critical elements of a fire safety strategy for tall buildings and thus attempt to highlight some specific global performance objectives. A survey of tall building fire investigations is conducted in order to assess the effectiveness of current designs in meeting these objectives, and the current state-of-the-art of fire safety design guidance for tall structures is also analysed on these terms. The correct definition of the design fire for open plan compartments is identified as the critical knowledge gap that must be addressed in order to achieve tall building performance objectives and to provide truly innovative, robust fire safety for these unique structures.