• Title/Summary/Keyword: premolar

Search Result 987, Processing Time 0.027 seconds

REGENERATIVE CAPACITY OF DEMINERALIZED BONE GRAFT AND GUIDED TISSUE REGENERATION ON DEHISCED ALVEOLAR BONE ADJACENT TO DENTAL IMPLANT (탈회이식골과 유도조직재생용 차폐막이 인공치아 매식채 주위의 골열개창 치유에 미치는 효과)

  • Chung, Kyeong-Uk;Choi, Sang-Mook
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.2
    • /
    • pp.341-356
    • /
    • 1995
  • The purpose of this study was to evaluate the effect of demineralized freeze dried bone and demineralized bone gel with guided tissue regeneration treatment around titanium implants with dehisced bony defects and also evaluate space maintaining capacity of demineralized bone gel type and DFDB powder type under e-PTFE membrane. In 3 Beagle dogs, mandibular premolar was extracted and four peri-implant osteotomies were formed for dehiscence. After insertion of implants, the four peri-implant defects were treated as follows. 1) In control group. no graft material and barrier membrane were applied. 2) In experimental group.1, the site was covered only with the e-PTFE membrane. 3) In experimental group 2,received DFDB powder and covered by the e-PTFE membrane. 4) In experimental group 3, demineralized bone gel and e-PTFE membrane were used. By random selection, animals were sacrificed at 4, 8, 12 weeks. The block sectioned specimens were prepared for decalcified histologic evaluation(hematoxylin and eosin staining) and undecalcified histologic evahiation(Von Kossa's and toluidine blue staining) with light microscopy. The results of this study were as follows. 1) In control group, there was a little new bone formation and connective tissue was completely filled in the defect area. 2) Experimental group 1 showed lesser quantity of bone formation as compared to the bone grafted group. Thin vertical growth of new bone formation around implant fixture was shown. 3) Experimental group 2 showed thick bucco-lingual growth of new bone formation and grafted bone particles were almost resorbed in 12 week group. 4) In experimental group 3, most grafted bone particles were not resorbed in 12 week group and thick bucco-lingual bone formation was shown in dehisced defect base area. 5) There was no remarkable differences in space making capacity and new bone formation procedure between demineralized freeze-dried bone powder type and demineralized bone gel type.

  • PDF

Effect of root planing on the reduction of probing depth and the gain of clinical attachment depending on the mode of interproximal bone resorption

  • Choi, Yoon Mi;Lee, Ju-Youn;Choi, Jeomil;Joo, Ji-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.5
    • /
    • pp.184-189
    • /
    • 2015
  • Purpose: The purpose of the present study was to evaluate the effect of root planing on the reduction of probing pocket depth and the gain of clinical attachment depending on the pattern of bone resorption (vertical versus horizontal bone loss) in the interproximal aspect of premolar teeth that showed an initial probing pocket depth of 4-6 mm. Methods: In this study, we analyzed 68 teeth (15 from the maxilla and 53 from the mandible) from 32 patients with chronic periodontitis (17 men and 15 women; mean age, 53.6 years). The probing pocket depth and clinical attachment level at all six sites around each tooth were recorded before treatment to establish a baseline value, and then three months and six months after root planing. Results: The reduction in interdental pocket depth was 1.1 mm in teeth that experienced horizontal bone loss and 0.7 mm in teeth that experienced vertical bone loss. Interdental attachment was increased by 1.0 mm in teeth with horizontal bone loss and by 0.7 mm in teeth with vertical bone loss. The reduction of probing pocket depth and the gain of clinical attachment occurred regardless of defect patterns three and six months after root planing. Conclusions: The reduction of pocket depth and gain in the clinical attachment level were significantly larger in horizontally patterned interproximal bone defects than in vertical bone defects.

What is the changing frequency of diamond burs?

  • Emir, Faruk;Ayyildiz, Simel;Sahin, Cem
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.93-100
    • /
    • 2018
  • PURPOSE. The purpose of this study was to determine the changing frequency of a diamond bur after multiple usages on 3 different surfaces. MATERIALS AND METHODS. Human premolar teeth (N = 26), disc shaped direct metal laser sintered CoCr (N = 3) and zirconia specimens (N = 3) were used in this study. Groups named basically as Group T for teeth, Group M for CoCr, and Group Z for zirconia. Round tapered black-band diamond bur was used. The specimens were randomly divided into three groups and placed with a special assembly onto the surveyor. 1, 5, and 10 preparation protocols were performed to the first, second, and third sub-groups, respectively. The subgroups were named according to preparation numbers (1, 5, 10). The mentioned bur of each group was then used at another horizontal preparation on a new tooth sample. The same procedure was used for CoCr and zirconia disc specimens. All of the bur surfaces were evaluated using roughness analysis. Then, horizontal tooth preparation surfaces were examined under both stereomicroscope and SEM. The depth maps of tooth surfaces were also obtained from digital stereomicroscopic images. The results were statistically analyzed using One-Way ANOVA, and the Tukey HSD post-hoc tests (${\alpha}=.05$). RESULTS. All of the groups were significantly different from the control group (P<.001). There was no significant difference between groups Z5 and Z10 (P=.928). Significant differences were found among groups T5, M5, and Z5 (P<.001). CONCLUSION. Diamond burs wear after multiple use and they should be changed after 5 teeth preparations at most. A diamond bur should not be used for teeth preparation after try-in procedures of metal or zirconia substructures.

Flexural strengths of implant-supported zirconia based bridges in posterior regions

  • Rismanchian, Mansour;Shafiei, Soufia;Nourbakhshian, Farzaneh;Davoudi, Amin
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.346-350
    • /
    • 2014
  • PURPOSE. Impact forces in implant supported FDP (fixed dental prosthesis) are higher than that of tooth supported FDPs and the compositions used in frameworks also has a paramount role for biomechanical reasons. The aim of this study was to evaluate the flexural strength of two different zirconia frameworks. MATERIALS AND METHODS. Two implant abutments with 3.8 mm and 4.5 mm platform were used as premolar and molar. They were mounted vertically in an acrylic resin block. A model with steel retainers and removable abutments was fabricated by milling machine; and 10 FDP frameworks were fabricated for each Biodenta and Cercon systems. All samples were thermo-cycled for 2000 times in $5-55^{\circ}C$ temperature and embedded in $37^{\circ}C$ artificial saliva for one week. The flexural test was done by a rod with 2 mm ending diameter which was applied to the multi-electromechanical machine. The force was inserted until observing fracture. The collected data were analyzed with SPSS software ver.15, using Weibull modulus and independent t-test with the level of significance at ${\alpha}=.05$. RESULTS. The mean load bearing capacity values were higher in Biodenta but with no significant differences (P>.05). The Biodenta frameworks showed higher load bearing capacity ($F_0=1700$) than Cercon frameworks ($F_0=1520$) but the reliability (m) was higher in Cercon (m=7.5). CONCLUSION. There was no significant difference between flexural strengths of both zirconia based framework systems; and both Biodenta and Cercon systems are capable to withstand biting force (even parafunctions) in posterior implant-supported bridges with no significant differences.

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

LANGERHANS CELL HISTIOCYTOSIS IN MANDIBLE : CASE REPORT (하악골에 발생한 Langerhans Cell Histiocytosis 환아의 증례보고)

  • Yoon, Hyun-Joo;Lee, Jae-Ho;Yoon, Jung-Hoon;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.8-11
    • /
    • 2001
  • Langerhans Cell Histiocytosis (LCH) is characterized by proliferation of Langerhans cells. The clinical manifestation varies from solitary bone lesion to multi-system, life threatening disorder. The younger the patient is and the more system is involved, the worse the prognosis is. The jaw is involved $10\sim20$ percent of all LCH and it is involved usually in early stage of LCH. In this case the patient is three years old girl who suffered from pain of whole mandibular body and histological examination confirmed the diagnosis LCH. She is referred to pediatrics and managed with combined chemotherapy. Due to the possibility of recurrence, we follow up the girl and she need orthodontic and prosthodontic treatment in the future because of the loss of lower left 2nd premolar. We report this case because early recognized LCH in dental hospital result in good prognosis.

  • PDF

MYOFIBROMA OF THE MANDIBLE (하악골에 발생한 근섬유종)

  • Yoon, Jung-Hoon;Kim, Su-Gwan;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.10-14
    • /
    • 2003
  • Myofibroma is a rare spindle cell neoplasm that consists of myofibroblsasts. Although it was originally described as a multicentric tumor process affecting infants and young children, it is now recognized that most cases of the tumor are soliatary and that it can occur at any age. This case is a myofibroma involving the right mandibular body in a 9-year-old boy. Radiographic examination revealed a relatively well-demarcated radiolucent lesion surrounding the impacted right mandibular canine and first premolar crown. The histologic sections composed of interlacing bundles of spindle cells with tapered or blunt-ended nuclei admixed with a foci of hemangiopericytoma-like appearance. Immunohistochemical staining demonstrated a positive reaction to vimentin and smooth muscle actin, but they are negative for desmin and S-100. The presence of well circumscribed radiolucent solid lesion in children as observed in this case, differential diagnosis of myofibroma must be included. In this case, there was no recurrence 6 months after enucleation and eruption guide of the impacted tooth is ongoing now.

  • PDF

A Study on the Accuracy of the Electronic Apex Locator Using a Micro-Computed Tomography (미세단층촬영기(Micro-CT)를 이용한 전자 근관장 측정기의 정확성에 관한 연구)

  • Chun, Keyoung-Jin;Kim, Yang-Soo;Nam, Tae-Kye
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.8 s.197
    • /
    • pp.116-121
    • /
    • 2007
  • The length of root canal has to be measured for endodontic treatment. Several electronic apex locators were developed to measure the length of root canal by other researchers. And their accuracies were verified by X-ray or micrometer method. But these methods did not consider the non-linear bends of pulp and had ${\pm}0.5mm$ error which was large enough to measure the length of root canal. The purpose of this study is the introduction of a new method to measure the length of root canal and the verification of the accuracy of an electronic apex locator using a Micro-CT. The length of root canal of 6 teeth were measured with the electronic apex locator. When the electronic apex locator reads 0.5, 0.6, 0.7, 0.8, 0.9 and 1.0 mm length of the file which was inserted in the hole of the tooth to measure the length of root canal. The average (${\pm}$Standard deviation) length of root canal of 6 teeth measured by the Micro-CT was $0.49{\pm}0.03,\;0.59{\pm}0.04,\;0.68{\pm}0.03,\;0.78{\pm}0.03,\;0.90{\pm}0.04\;and\;1.01{\pm}0.03mm$, respectively. The maximum error of the electronic apex locator was 0.06 mm.

Successful Treatment Using Wire-reinforced Interdental Splint for a Puppy with Rostral Mandibular Fractures

  • Kim, Se Eun;Shim, Kyung Mi;Kim, Seung Hyun;Bae, Chun-Sik;Kang, Seong Soo
    • Journal of Veterinary Clinics
    • /
    • v.35 no.4
    • /
    • pp.137-140
    • /
    • 2018
  • A five-month-old toy poodle was referred for treatment of bilateral mandibular fractures. Preoperative skull and dental radiographs showed rostral mandibular fractures and permanent teeth that had not yet erupted. In addition to providing stability for the healing of fractures, it is very important to focus on restoring normal occlusion. The mandibular fractures were repaired using interdental wiring in a dentate area where the deciduous canines and fourth premolars were stable and could be used to anchor the interdental fixation. In the absence of an erupted permanent mandibular first molar, the modified Risdon wiring was performed using the deciduous mandibular fourth premolars as anchor teeth. An intraoral splint was placed on the mandibular teeth using self-curing composite resin. Five months after surgery, the patient had experienced no complications, and the permanent teeth had erupted normally. In this case, which involves a small-breed puppy with deciduous dentition, treatment with a wire-reinforced interdental splint using intact deciduous fourth premolar teeth as anchor teeth can be considered as a suitable method for rostral mandibular fracture restoration.