References
- Humphries RM, Yaman P, Bloem TJ. The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 1990;5:331-6.
- Sahin S, Cehreli MC. The significance of passive framework fit in implant prosthodontics: current status. Implant Dent 2001;10:85-92. https://doi.org/10.1097/00008505-200104000-00003
- Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications with implants and implant prostheses. J Prosthet Dent 2003;90:121-32. https://doi.org/10.1016/S0022-3913(03)00212-9
- Sones AD. Complications with osseointegrated implants. J Prosthet Dent 1989;62:581-5. https://doi.org/10.1016/0022-3913(89)90084-X
- Wee AG, Aquilino SA, Schneider RL. Strategies to achieve fit in implant prosthodontics: a review of the literature. Int J Prosthodont 1999;12:167-78.
- Assif D, Marshak B, Schmidt A. Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 1996;11:216-22.
- Henry PJ. An alternative method for the production of accurate casts and occlusal records in osseointegrated implant rehabilitation. J Prosthet Dent 1987;58:694-7. https://doi.org/10.1016/0022-3913(87)90421-5
- Barrett MG, de Rijk WG, Burgess JO. The accuracy of six impression techniques for osseointegrated implants. J Prosthodont 1993;2:75-82. https://doi.org/10.1111/j.1532-849X.1993.tb00387.x
- Carr AB. Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 1991;6:448-55.
- Assuncao WG, Filho HG, Zaniquelli O. Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 2004;13:358-66. https://doi.org/10.1097/01.id.0000144509.58901.f7
- Del'Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo Fde A Jr. Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implants 2008;23:226-36.
- Phillips KM, Nicholls JI, Ma T, Rubenstein J. The accuracy of three implant techniques: a three dimensional analysis. Int J Oral Maxillofac Implants 1994;9:533-40.
- Cabral LM, Guedes CG. Comparative analysis of 4 impression techniques for implants. Implant Dent 2007;16:187-94. https://doi.org/10.1097/ID.0b013e3180587b3f
- Herbst D, Nel JC, Driessen CH, Becker PJ. Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 2000;83:555-61. https://doi.org/10.1016/S0022-3913(00)70014-X
- Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A. Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implants 2004;19:192-8.
- Wenz HJ, Hertrampf K. Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection. Int J Oral Maxillofac Implants 2008;23:39-47.
- Carr AB. Comparison of impression techniques for a two-implant 15-degree divergent model. Int J Oral Maxillofac Implants 1992;7:468-75.
- Conrad HJ, Pesun IJ, DeLong R, Hodges JS. Accuracy of two impression techniques with angulated implants. J Prosthet Dent 2007;97:349-56. https://doi.org/10.1016/S0022-3913(07)60023-7
- Parker MH, Cameron SM, Hughbanks JC, Reid DE. Comparison of occlusal contacts in maximum intercuspation for two impression techniques. J Prosthet Dent 1997;78:255-9. https://doi.org/10.1016/S0022-3913(97)70023-4
- Hsu CC, Millstein PL, Stein RS. A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Dent 1993;69:588-93. https://doi.org/10.1016/0022-3913(93)90287-X
- Spector MR, Donovan TE, Nicholls JI. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990;63:444-7. https://doi.org/10.1016/0022-3913(90)90235-5
- Liou AD, Nicholls JI, Yuodelis RA, Brudvik JS. Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. Int J Prosthodont 1993;6:377-83.
- Rashidan N, Alikhasi M, Samadizadeh S, Beyabanaki E, Kharazifard MJ. Accuracy of implant impressions with different impression coping types and shapes. Clin Implant Dent Relat Res 2012;14:218-25. https://doi.org/10.1111/j.1708-8208.2009.00241.x
- Cox JR, Brandt RL, Hughes HJ. A clinical pilot study of the dimensional accuracy of double-arch and complete-arch impressions. J Prosthet Dent 2002;87:510-5. https://doi.org/10.1067/mpr.2002.124489
- Parfitt GJ. Measurement of the physiological mobility of individual teeth in an axial direction. J Dent Res 1960;39:608-18. https://doi.org/10.1177/00220345600390032201
- Goodkind RJ, Heringlake CB. Mandibular flexure in opening and closing movements. J Prosthet Dent 1973;30:134-8. https://doi.org/10.1016/0022-3913(73)90046-2
- Ceyhan JA, Johnson GH, Lepe X, Phillips KM. A clinical study comparing the three-dimensional accuracy of a working die generated from two dual-arch trays and a complete-arch custom tray. J Prosthet Dent 2003;90:228-34. https://doi.org/10.1016/S0022-3913(03)00237-3
- Stimmelmayr M, Guth JF, Erdelt K, Happe A, Schlee M, Beuer F. Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw. Clin Oral Investig 2013;17:1929-35. https://doi.org/10.1007/s00784-012-0885-z
- Stimmelmayr M, Erdelt K, Guth JF, Happe A, Beuer F. Evaluation of impression accuracy for a four-implant mandibular model-a digital approach. Clin Oral Investig 2012;16:1137-42. https://doi.org/10.1007/s00784-011-0622-z
- Papaspyridakos P, Hirayama H, Chen CJ, Ho CH, Chronopoulos V, Weber HP. Full-arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fit. Clin Oral Implants Res 2016;27:1099-105. https://doi.org/10.1111/clr.12695
- Papaspyridakos P, Gallucci GO, Chen CJ, Hanssen S, Naert I, Vandenberghe B. Digital versus conventional implant impressions for edentulous patients: accuracy outcomes. Clin Oral Implants Res 2016;27:465-72.
- Rhee YK, Huh YH, Cho LR, Park CJ. Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition. J Adv Prosthodont 2015;7:460-7. https://doi.org/10.4047/jap.2015.7.6.460
Cited by
- Reverse engineering technique on the evaluation of impression accuracy in angulated implants vol.59, pp.3, 2018, https://doi.org/10.4047/jkap.2021.59.3.261
- Comparative study of three composite materials in bonding attachments for clear aligners vol.24, pp.4, 2018, https://doi.org/10.1111/ocr.12465