• Title/Summary/Keyword: prefabricated system

Search Result 138, Processing Time 0.023 seconds

Evaluation of Residential Performance in Commercialization of Flexible Unit Infra Free Residential for Disaster (재난 시 대응을 위한 Flexible-Unit형 인프라 프리(임시)주거의 성능평가)

  • Park, Beungyong;Cho, Jinkyun;Jeong, Yongdae;Lee, Wonhak
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.37-49
    • /
    • 2018
  • In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated the physical performance, insulation, airtightness. The second step, we was evaluated energy performance building to design heating and cooling system to combined PV system. As a results, the insulation performance wall was $0.18W/(m^2{\cdot}K)$. The results of air-tightness was 12.13 ACH@50 (1/h). The building energy demand ratings and solar energy generation has the possible to be ballanced.

Mechanized tunnels lining prefabricated segments production methods

  • Elaheh Banihashemigargari;Amir H. Rezaeifarei
    • Geomechanics and Engineering
    • /
    • v.32 no.5
    • /
    • pp.503-512
    • /
    • 2023
  • In tunneling projects, a significant part of the costs is spent on segment production. By more economically producing, the cost of tunnel construction can be greatly reduced, especially in long and large-diameter tunnels. In the present study, the effect of using the Carousel method in the improvement of the production system performance compared to the conventional Static system has been studied. To carry out the research, a quantitative comparison of cost and production time was carried out for two production methods using the available documentation. The opinions of experts have been obtained using questionnaires and qualitative comparison of cost, time and production quality was done by implementation of statistical analysis. The SPSS software and the univariate t-test were used to analyze the questionnaires. According to the results of statistical analysis with SPSS, the use of the Carousel method will reduce production time and costs along with increasing manufacturing quality. According to the documentation analysis, the Carousel method reduces the cost of production by almost 30% and leads to a reduction of the production time to approximately 40% of the Static moulds system. The Carousel method has a higher production rate, efficiency, and better performance. Research into quantifying the benefits of Carousel method in the production system performance is very limited. This comparison is based on real information from the under construction Tabriz Metro project. This article can be very helpful in choosing the best production method.

Assembly Performance Evaluation for Prefabricated Steel Structures Using k-nearest Neighbor and Vision Sensor (k-근접 이웃 및 비전센서를 활용한 프리팹 강구조물 조립 성능 평가 기술)

  • Bang, Hyuntae;Yu, Byeongjun;Jeon, Haemin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.5
    • /
    • pp.259-266
    • /
    • 2022
  • In this study, we developed a deep learning and vision sensor-based assembly performance evaluation method isfor prefabricated steel structures. The assembly parts were segmented using a modified version of the receptive field block convolution module inspired by the eccentric function of the human visual system. The quality of the assembly was evaluated by detecting the bolt holes in the segmented assembly part and calculating the bolt hole positions. To validate the performance of the evaluation, models of standard and defective assembly parts were produced using a 3D printer. The assembly part segmentation network was trained based on the 3D model images captured from a vision sensor. The sbolt hole positions in the segmented assembly image were calculated using image processing techniques, and the assembly performance evaluation using the k-nearest neighbor algorithm was verified. The experimental results show that the assembly parts were segmented with high precision, and the assembly performance based on the positions of the bolt holes in the detected assembly part was evaluated with a classification error of less than 5%.

Development of Prefabricated Joint for 66kV Cross Linked Polyethylene Cable. (66kV XLPE Cable용 조립형 접속함의 개발)

  • Oh, E.J.;Kim, K.Y.;Lee, J.Y.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2123-2125
    • /
    • 1999
  • In recent the XLPE cable has been applied more widely because of its advantages, such as the low-cost and simple installation. For a prefabricated joint, its working time is short, its jointing procedures aγe simple, and its quality control is easy. Electrical performance targets of our developed 66kV cable accessories has been approved through the type test in accordance with IEC publication 840. This paper describes the developmental effort in terms of the design, structure and results of performance verification tests for 66kV XLPE cable system.

  • PDF

Development of Prefabricated Joint for 132kV Cross Linked Polyethylene Cable (132kV XLPE CABLE 조립형 접속함의 개발)

  • Kim, J.H.;Oh, E.J.;Kim, K.Y.;Park, J.K.;Jeong, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2017-2019
    • /
    • 2000
  • In recent the XLPE cable has been applied more widely because of its advantages, such as the low-cost and simple installation. For a prefabricated joint, its working time is short, its jointing procedures are simple, and its quality control is easy. Electrical performance targets of our developed 132kV cable accessories has been approved through the type test in accordance with IEC publication 840. This paper describes the developmental effort in terms of the design, structure and results of performance verification tests for 132kV XLPE cable system.

  • PDF

Trial Installation and Performance Evaluation of Prefabricated Concrete Slab Track on Revenue Line (프리캐스트 콘크리트 슬래브궤도의 영업선 시험시공 및 성능평가)

  • Jang, Seung-Yup;Kang, Yun-Suk;Lee, Hu-Sam;Kim, Yu-Bong;Lee, Jong-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.840-845
    • /
    • 2008
  • To develop our original technology of concrete slab track, being widely accepted for new track, prefabricated concrete slab track, or precast concrete slab track has been developed. They have two different types according to slab shape and its dimensions, connection of slabs and connecting structure onto substructure. After the system design and successful performance evaluation in the laboratory, the trial installation on revenue line has been carried out. This paper is presenting the result of the trial installation and the performance tests in field. The performance tests have been performed as visual inspection for cracks and damages, measurement of track alignment and elastic behavior of track under passing trains. The performance test results during last 2 years have shown that no remarkable damages and settlements were found, and track alignment and elastic track behavior both exhibits good status.

  • PDF

Numerical Analysis of Soil Vapour Extraction Remediation System using Prefabricated Vertical Drain (토목섬유 연직배수재를 활용한 토양증기추출복원시스템의 수치해석)

  • Shin, Eun-Chul;Park, Jeong-Jun;Lee, Kyu-Woong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.4
    • /
    • pp.1-8
    • /
    • 2008
  • Soil vapor extraction (SVE) is an effective and cost efficient method of removing volatile organic compounds (VOCs) and petroleum hydrocarbons from unsaturated soils. However, soil vapor extraction becomes ineffective in soils with low gas permeability, for example soils with air permeabilities less than 1 Darcy. The aim of this study is to investigate numerically the performance of a prefabricated vertical drain (PVD) as a SVE well, and the pattern of the induced air flow. A validated numerical model for a single PVD extraction well is developed based on the result of a well-designed laboratory model test. The validity of the simple analytical approach to determine air permeability based on the results of model tests is also discussed.

  • PDF

Fixed Prosthetic Restoration in an Edentulous Patient with NobelGuideTM System (양악 무치악 환자에서 NobelGuideTM 시스템을 이용한 고정성 임플란트 보철수복)

  • Shin, Hyoung-Joo;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.243-253
    • /
    • 2009
  • This report described a technique utilizing a computer-aided design (CAD) /computer-aided machining (CAM) - guided surgical implant placement and prefabricated fixed complete denture for an immediately loaded restoration. A patient with an edentulous maxilla and mandible received 6 implants in maxilla and 6 implants in the mandible using CAD/CAM surgical templates. Prefabricated provisional maxillary and mandibular implant supported fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics, function during 6 months. Definitive prostheses were fabricated.

Evaluation of Structural Performance of Precast Prefabricated Bridge Column using Nonlinear Finite Element Analysis (비선형 유한요소해석을 이용한 조립식 교각의 성능 평가)

  • Chung, Chul-Hun;Yun, Yeon-Suk;Whang, Eun-Jung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.383-390
    • /
    • 2008
  • A Precast Prefabricated Bridge Column using steel tube and prestressing bar was proposed for the application of precast method on substructure. A column specimen designed by the proposed bridge column system was made and performed a quasi-static test. The failure mode appeared to be a flexural failure and there is no damage on column segment connection. And it is good use of the self-centering ability by prestressing force. Test results showed that a column specimen satisfy the earthquake specification, and the structural stability was verified. Nonlinear finite element analysis was performed and compared with the test results. Force-displacement relation and location of crack from the analysis results were compared with the test results and it agreed well. The quantitative analysis was also performed by a parametric study using this modeling technique.