• Title/Summary/Keyword: power regulation

Search Result 1,331, Processing Time 0.026 seconds

The Influence of Stress and Emotion Regulation Ability of Health College Students on University Life Adjustment (보건계열 대학생들의 스트레스와 정서조절에 따른 대학생활적응 관련성 연구)

  • Kang, Hyun-Joo
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.9
    • /
    • pp.65-71
    • /
    • 2021
  • The purpose of this study is to investigate the factors that affect stress, emotional regulation, and adjustment to college life of health college students. The survey was conducted from June 21 to 30, 2021 for 190 health students in G and J area. The data were analyzed by frequency analysis, reliability analysis, simple correlation analysis, and multiple regression analysis. The results showed that positive perception had positive correlation with negative perception(r=-.286,p<.01), emotional regulation (r=.296,p<.01), and university life adjustment(r=.520,p<.01). Negative perception was correlated with emotional regulation(r=-.619,p<.01), university life adjustment (r=-.428,p<.01) and negative(-). Emotional regulation had a positive correlation with university life adjustment(r=.341,p<.01). Positive perception, negative perception, and emotional regulation, which are sub-factors of perceived stress, were the factors affecting the adjustment to university life, and the explanatory power was 84%. Therefore, it is necessary to develop a program that can improve the adjustment of college students in health.

A Study on the V2G Application using the Battery of Electric Vehicles under Smart Grid Environment (스마트그리드 환경에서 전기자동차 배터리를 이용한 V2G의 활용방안에 관한 연구)

  • Choi, Jin-Young;Park, Eun-Sung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.40-45
    • /
    • 2014
  • This study examines the system and process of battery stored energy in vehicles and suggest the effective area for the use of V2G(vehicle-to-grid) from Jeju Smart Grid Demonstration Project. V2G means technology of electric power transmission from the battery of electric-drive vehicles to state grid. As for the increasing of effectiveness for demand-side control, V2G is a very good alternative. In the U.S., the utilization of electric vehicles is under 40% on average. In this case, we can use he battery of electric vehicle as role of frequency regulation or generator of demand-side resource. V2G, which is the element of Smart Transportation, consists of electric vehicle battery, BMS(battery management system), OBC(on-board charger), charging infrastructure, NOC(network operating center) and TOC(total operation center). V2G application has been tested for frequency regulation to secure the economical efficiency in the United States. In this case, the battery cycle life is not verified its disadvantage. On the other hand, Demand Response is required by low c-rate of battery in electric vehicle and It can be small impact on the battery cycle life. This paper concludes business area of demand response is more useful than frequency regulation in V2G application of electric vehicles in Korea. This provides the opportunity to create a new business for power grid administrator with VPP(virtual power plant).

A Voltage Regulation System for Independent Load Operation of Stand Alone Self-Excited Induction Generators

  • Kesler, Selami;Doser, Tayyip L.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1869-1883
    • /
    • 2016
  • In recent years, some converter structures and analyzing methods for the voltage regulation of stand-alone self-excited induction generators (SEIGs) have been introduced. However, all of them are concerned with the three-phase voltage control of three-phase SEIGs or the single-phase voltage control of single-phase SEIGs for the operation of these machines under balanced load conditions. In this paper, each phase voltage is controlled separately through separated converters, which consist of a full-bridge diode rectifier and one-IGBT. For this purpose, the principle of the electronic load controllers supported by fuzzy logic is employed in the two-different proposed converter structures. While changing single phase consumer loads that are independent from each other, the output voltages of the generator are controlled independently by three-number of separated electronic load controllers (SELCs) in two different mode operations. The aim is to obtain a rated power from the SEIG via the switching of the dump loads to be the complement of consumer load variations. The transient and steady state behaviors of the whole system are investigated by simulation studies from the point of getting the design parameters, and experiments are carried out for validation of the results. The results illustrate that the proposed SELC system is capable of coping with independent consumer load variations to keep output voltage at a desired value for each phase. It is also available for unbalanced consumer load conditions. In addition, it is concluded that the proposed converter without a filter capacitor has less harmonics on the currents.

Current Source ZCS PFM DC-DC Converter for Magnetron Power Supply

  • Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.20-28
    • /
    • 2009
  • This paper presents the design of zero current switching ZCS pulse frequency modulation type DC-DC converter for magnetron power supply. A magnetron serving as the microwave source in a microwave oven is driven by a switch mode power supply (SMPS). SMPSs have the advantages of improved efficiency, reduced size and weight, regulation and the ability to operate directly from the converter DC bus. The demands of the load system and the design of the power supply required to produce constant power at 4[kV]. A magnetron power supply requires the ability to limit the load current under short circuit conditions. The current source series resonant converter is a circuit configuration which can achieve this. The main features of the proposed converter are an inherent protection against a short circuit at the output, a high voltage gain and zero current switching over a large range of output power. These characteristics make it a viable choice for the implementation of a high voltage magnetron power supply.

Dielectric Barrier Discharge for Ultraviolet Light Generation and Its Efficient Driving Inverter Circuit

  • Oleg, Kudryavtsev;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.101-105
    • /
    • 2004
  • The efficient power MOSFET inverter applied for a simple and low cost power supply is proposed for driving the dielectric barrier discharge (DBD) lamp load. For decades, the DBD phenomenon has been used for ozone gas production in industry. In this research, the ultraviolet and visible light sources utilizing the DBD lamp is considered as the load for solid-state high frequency power supply. It is found that the simple voltage-source single-ended quasi-resonant ZVS inverter with only one active power switch could effectively drive this load with the output power up to 700 W. The pulse density modulation based control scheme for the single-ended quasi-resonant ZVS inverter using a low voltage and high current power MOSFET switching device is proposed to provide a linear power regulation characteristic in the wide range 0-100% of the full power as compared with the conventional control based Royer type parallel resonant inverter type power supplies.

A Design of Power Circuit and LCL Filter for Switching Mode PV Simulator (스위칭방식 PV Simulator의 전력회로와 LCL필터 설계)

  • Lee, Sung-Min;Yu, Tae-Sik;Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.431-437
    • /
    • 2012
  • PV simulators are essential equipment for testing power conditioning systems (PCS) which are one of an important part in PV generator systems, for testing before shipment. High dynamic PV simulator is required since MPPT(Maximum Power Point Tracking) test procedure has been established by EN50530 regulation recently. Most high quality PV simulator prevailed in the market is linear type which however has low efficiency. This paper proposes design guide lines for the power stage and LCL type filter cooperating with a switching mode PV simulator that shows high efficiency and very low power consumption. Proposed theory is verified by experiment.

Analysis of Cross-Regulation Characteristics for Multi-Output LLC Resonant Converter (다중출력 LLC 공진 컨버터의 Cross-regulation 특성 분석)

  • Jeong, Jin-Woo;Lim, Jeong-Gyu;Chung, Se-Kyo;Kim, Jong-Hae;Oh, Dong-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.151-152
    • /
    • 2011
  • This paper describes a cross-regulation characteristics of a multi-output LLC resonant converter widely used in consumer electronics. The output characteristics of the multi-output LLC converter is derived from the assumption that the current and voltage to flow through the resonant network is sinusoidal and the duty loss is investigated. The simulation results are provided to verify the theoretic results.

  • PDF

Low Drop Out Regulator with Ripple Cancelation Circuit (잡음 제거 회로를 이용한 LDO 레귤레이터)

  • Kim, Chae-Won;Kwon, Min-Ju;Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.264-267
    • /
    • 2017
  • In this paper, A low dropout (LDO) regulator that improves the power supply rejection ratio by using a noise canceling circuit is proposed. The noise rejection circuit between the error amplifier and the pass transistor is designed to reduce the influence of the pass transistor on the noise coming from the voltage source. The LDO regulator has the same regulation characteristics as the conventional LDO regulator. The proposed circuit uses 0.18um process and Cadence's Virtuoso and Specter simulator.

A study on the Optimal Operation of Step Voltage Regulator(SVR) in the Distribution Feeders(3) (고압배전선로의 선로전압조정장치(SVR)의 최적운용에 관한 연구(3))

  • Lee, Eun-Mi;Rho, Dae-Seok;Park, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.97-99
    • /
    • 2003
  • This paper deals with optimal voltage regulation methods of line voltage regulator(SVR : Step Voltage Regulator) in power distribution systems. In order to deliver suitable voltages to as many customers as possible, the optimal sending voltage of SVR should be decided by the effective operation of voltage regulators at the distribution feeders and substations. In this paper, a new voltage regulation method based on the existing method is presented and an optimal coordination method of multiple voltage regulators is extended. The results from a case study show that the proposed methods can be a practical tool for the voltage regulation in distribution systems.

  • PDF

Analysis of Cross-Regulation Characteristics for LLC Resonant Converter of Secondary Multi-winding Structure (2차측 Multiple-Winding 구조의 변압기를 갖는 LLC 공진형 컨버터의 Cross-regulation 특성 분석)

  • Kim, Sung-Jae;Kim, Yeong-Sam;Kim, Jong-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.289-290
    • /
    • 2019
  • 2차측 Multi-winding구조의 LLC공진형 컨버터는 교차조절(Cross-regulation) 특성에 의해 각 출력의 부하의 변화에 따라 출력전압의 불균형 문제가 있다. 본 논문에서는 2차측 Multi-winding 구조의 LLC공진형 컨버터에서 나타나는 교차조절 특성을 이론적으로 분석하고 240W급 LLC공진형 컨버터를 이용하여 실험을 진행한다. 실험 결과를 통해 출력 채널 수의 증가에 따른 교차조절 특성에 대해 고찰한다.

  • PDF