• Title/Summary/Keyword: power recovery unit

Search Result 64, Processing Time 0.023 seconds

Alternate Energy: Gravity Powered Rail Transportation Systems

  • Bojji, Rajaram
    • International Journal of Railway
    • /
    • 제2권1호
    • /
    • pp.22-29
    • /
    • 2009
  • A simple pendulum shows how efficient gravity is in recovering energy. Any transportation is a linearly oscillating system; every load gains kinetic energy, but loses the same to come to a stop. The Gravity Power Towers comprise of a set of vertically moving heavy masses coupled, through microprocessor controlled continuously variable gear and cable system, to a horizontally rolling unit on wheels either on rail or road. The heavy masses move vertically up against gravity gaining potential energy while stopping a moving mass; move down under gravity force, giving out energy. The Tower thus accelerates or sustains the speed a rolling unit, and while decelerating, recover the kinetic energy. Speeds of 360 kmph can be attained. Recovery of energy varies from 98.5-70%; the longer the distance between stops, the lesser is recovery. The economical, omnipresent & eternal Gravity Power grants energy independence to many a nation. Global warming reduces.

  • PDF

마이크로터빈의 열회수 성능시험 (Test of Heat Recovery Performance of a Microturbine)

  • 전무성;이종준;김동섭;장세동
    • 대한기계학회논문집B
    • /
    • 제32권8호
    • /
    • pp.629-635
    • /
    • 2008
  • Recently, microturbines have received attention as a small-scale distributed power generator. Since the exhaust gas carries all of the heat release, the microturbine CHP (combined heat and power) system is relatively compact and easy to maintain. Generating hot water or steam is usual method of heat recovery from the microturbine. In this work, a heat recovery unit producing hot water was installed at the exhaust side of a 30 kW class microturbine and its performance characteristics following microturbine power variation was investigated. Heat recovery performance has been compared for different operating conditions such as constant hot water temperature and constant water flow rate. In particular, the influence of water flow rate and hot water temperature on the recovered heat was analyzed.

Utilizing Under Voltage Load Shedding Strategy to Prevent Delayed Voltage Recovery Problem in Korean Power System

  • Lee, Yun-Hwan;Oh, Seung-Chan;Lee, Hwan-Ik;Park, Sang-Geon;Lee, Byong-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.60-67
    • /
    • 2018
  • The presence of induction motor loads in a power system may cause the phenomenon of delayed voltage recovery after the occurrence of a severe fault. A high proportion of induction motor loads in the power system can be a significant influence on the voltage stability of the system. This problem referred to as FIDVR(Fault Induced Delayed Voltage Recovery) is commonly caused by stall of small HVAC unit(Heating, Ventilation, and Air Conditioner) after transmission or distribution system failure. This delayed voltage recovery arises from the dynamic characteristics associated with the kinetic energy of the induction motor load. This paper proposes the UVLS (Under Voltage Load Shedding) control strategy for dealing with FIDVR. UVLS based schemes prevent voltage instability by shedding the load and can help avoid major economic losses due to wide-ranging cascading outages. This paper review recent topic about under voltage load shedding and compare decentralized load shedding scheme with conventional load shedding scheme. The load shedding strategy is applied to an actual system in order to verify the proposed FIDVR mitigation solution. Simulations demonstrate the effectiveness of the proposed method in resolving the problem of delayed voltage recovery in the Korean Power System.

송전선로용 디지털 고장점 표정장치에 관한 연구 (A Study on Digital Fault Locator for Transmission Line)

  • 이경민;박철원
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.291-296
    • /
    • 2015
  • Transmission line is exposed to a large area, and then faults are likely to occur than the other component of power system. When a fault occurs on a transmission line, fault locator helps fast recovery of power supply on power system. This paper deals with the design of a digital fault locator for improvement accuracy of the fault distance estimation and a fault occurrence position for transmission line. The algorithm of a fault locator uses a DC offset removal filter and DFT filter. The algorithm utilizes a fault data of GPS time synchronized. The computed fault information is transmitted to the other side substation through communication. The digital fault locator includes MPU module, ADPU module, SIU module, and a power module. The MMI firmware and software of the fault locator was implemented.

폐루프 유압 에너지 회생 시스템에 관한 연구 (Design and Assessments of a Closed-loop Hydraulic Energy-Regenerative System)

  • 호 치엣 흥;윤종일;안경관
    • 유공압시스템학회:학술대회논문집
    • /
    • 유공압시스템학회 2010년도 춘계학술대회
    • /
    • pp.116-125
    • /
    • 2010
  • In this study, a novel hydraulic energy-regenerative system was presented from its proposal through its modeling to its control. The system was based on a closed-loop hydrostatic transmission and used a hydraulic accumulator as the energy storage system in a novel configuration to recover the kinetic energy without any reversion of the fluid flow. The displacement variation in the secondary unit was reduced, which widened the uses of several types of hydraulic pump/motors for the secondary unit. The proposed system was modeled based on its physical attributes. Simulation and experiments were performed to evaluate the validity of the employed mathematical model and the energy recovery potential of the system. The experimental results indicated that the round trip recovery efficiency varied from 22% to 59% for the test bench.

  • PDF

VDL Mode-2에 적용 가능한 버스트 모드 심벌 타이밍 복원기 (Burst Mode Symbol Timing Recovery for VDL Mode-2)

  • 김종만;최승덕;은창수
    • 한국항행학회논문지
    • /
    • 제13권3호
    • /
    • pp.337-343
    • /
    • 2009
  • 본 논문에서는 D8PSK 변조 방식을 이용하는 VDL Mode-2 수신기에 적용 가능한 버스트 모드 심벌 타이밍 복원기를 제안하고 성능 분석과 연동실험을 실시하였다. IIR 루프필터를 사용하여 심볼 타이밍 에러를 최소화 하는 방식은 수렴 속도가 늦기 때문에 버스트 모드에 적용하기 곤란하다. 즉 빠른 수렴 특성이 중요시 된다. 본 논문에서 제안한 방식은 프리앰블을 이용하여 초기 동기가 이루어진 후 최대 심벌 전력을 갖는 방향으로 한 샘플 빠르게 또는 한 샘플 느리게 샘플 클럭을 이동하여 최적의 심벌을 취하는 방식이다. 제안된 방식을 적용한 수신기와 호주 ADS사 송신 장비와 연동 시험한 결과 100 ppm 이상에서도 잘 동작함을 확인하였다.

  • PDF

300MW 태안 IGCC 플랜트 종합성능 특성 (Overall Performance characteristic for 300MW Taean IGCC Plant)

  • 김학용;김재환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.129.2-129.2
    • /
    • 2010
  • As a part of the government renewable energy policy, KOWEPO is constructing 300MW IGCC plant in Taean. IGCC plant consists of gasification block, air separation unit and power block, which performance test is separately conducted. Overall performance test for IGCC plant is peformed to comply with ASME PTC 46. Major factors affected on the overall efficiency for IGCC plant are external conditions, each block performance(gasification, ASU, power block), water/steam integration and air integration. Performance parameters of IGCC plant are cold gas efficiency, oxygen consumption, sensible heat recovery of syngas cooler for gasification block and purity of oxygen, flow amount of oxygen and nitrogen, power consumption for air separation unit and steam/water integration among the each block. The gas turbine capacity applied to the IGCC plant is 20 percent higher than NGCC gas turbine due to the low caloric heating value of syngas, therefor it is possible to utilize air integration between gas turbine and air separation unit to improve overall efficiency of the IGCC plant and there is a little impact on the ambient condition. It is very important to optimize the air integration design with consideration to the optimized integration ratio and the reliable operation. Optimized steam/water integration between power block and gasification block can improve overall efficiency of IGCC plant where the optimized heat recovery from gasification block should be considered. Finally, It is possibile to achieve the target efficiency above 42 percent(HHV, Net) for 300MW Taean IGCC plant by optimized design and integration.

  • PDF

유압식 엘리베이터 에너지 저감장치의 성능특성에 관한 연구 (A Study on the Performance Characteristics of an Energy Saving Unit in a Hydraulic Elevator)

  • 조인성
    • 한국산학기술학회논문지
    • /
    • 제14권6호
    • /
    • pp.2588-2595
    • /
    • 2013
  • 기존의 유압식 엘리베이터에서 엘리베이터 카의 하강행정 동안 손실 되는 유압 에너지를 회수하여 재사용하기 위하여 개발한 유압식 엘리베이터용 하이브리드 형 에너지 저감 장치에 대한 성능 특성에 관하여 연구하였다. 회수된 에너지는 축전지에 저장하여 재사용할 수 있도록 구성되어 있으며, 엘리베이터의 구동 조건에 따른 에너지 저감장치의 출력 특성, 효율 및 에너지 회수율 등에 관하여 실험을 통하여 규명하고자 하였다. 본 연구의 결과들은 하강행정 동안 버려지는 에너지의 회수율이 최대 약 54%로 에너지 저감 장치의 압력, 유량, 출력 전압과 전류, 효율 및 에너지 회수율 등과 같은 성능 특성들이 안정적이고 양호하다는 것을 보여주고 있으며, 본 연구를 통하여 유압식 엘리베이터의 에너지 저감 장치를 통하여 하강행정 동안 회수된 에너지를 재사용하데 매우 유용하며, 상용화 가능성이 충분하다는 것을 확인하였다.

전력품질 보상기와 부하모의장치의 연계시험 분석 (Performance Analysis of load simulator interconnected with Power Quality Compensator)

  • 배병열;조윤호;박용희;한병문
    • 전력전자학회논문지
    • /
    • 제12권1호
    • /
    • pp.89-97
    • /
    • 2007
  • 본 논문에서는 새로 개발된 전력품질 보상장치의 성능을 실험실에서 효과적으로 분석하기 위해 필요한 새로운 부하모의장치를 제안하였다. 제안하는 부하모의장치는 2대의 PWM 인버터가 직류 단을 공유한 구조로 선형과 비선형부하를 단일기기로 시험 가능하도록 설계되어 있다. 그리고 전력품질보상기의 하나인 능동전력필터와 연계시험을 수행하였다. 본 논문에서는 제안하는 부하모의장치와 능동전력필터의 연계 특성을 분석할 목적으로 PSCAD/EMTDC 소프트웨어를 이용하여 시뮬레이션 실시하였고 또한 실적용시 타당성을 검증할 목적으로 20kVA 용량의 부하모의장치와 10kVA용량의 능동전력필터를 제작하여 실험을 실시하였다. 시뮬레이션과 하드웨어 실험결과 제안하는 부하모의장치는 능동전력필터의 다양한 보상 능력 검증에 충분히 활용가능함을 알 수 있었다.

STATCOM을 활용한 FIDVR 완화 방안에 대한 연구 (A Study on the FIDVR Mitigation Scheme using Dynamic Voltage Support by STATCOM)

  • 이윤환;정승민
    • 전기학회논문지P
    • /
    • 제67권4호
    • /
    • pp.208-213
    • /
    • 2018
  • In this paper, we studied the control strategy of applying STATCOM(static synchronous compensator) to mitigate the FIDVR(fault induced delayed voltage recovery) phenomenon. The proportion of motor loads is gradually increasing which might affect power system stability. Excessive reactive power consumption by the stall of the motor loads causes FIDVR phenomenon. In addition, the low inertia of the small HVAC(heating, ventilation and air conditioner) unit will not separate itself in the event of a contingency, causing system instability. For this reason, we have developed a control strategy that utilizes STATCOM efficiently through static and dynamic analysis. Case studies on a Korean power system have validated the performance of the proposed scheme under severe contingency scenarios. The results have verified that the proposed strategy can effectively mitigate FIDVR and improve the stability and reliability of the system.