• Title/Summary/Keyword: power meter

Search Result 532, Processing Time 0.03 seconds

Chromospheric Sunspot Oscillations in H-alpha and Ca II 8542A

  • Maurya, Ram Ajor
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.61.2-61.2
    • /
    • 2013
  • We study chromospheric oscillations including umbral flashes and running penumbral waves in a sunspot using scanning spectroscopy in H-alpha and Ca II 8542A, with the Fast Imaging Solar Spectrograph (FISS) at the 1.6 meter New Solar Telescope at Big Bear Solar Observatory. A bisector method is applied to spectral observations to construct chromospheric Doppler velocity maps. Temporal sequence analysis of these shows enhanced high-frequency oscillations inside the sunspot umbra in both lines. Their peak frequency gradually decreases outward from the umbra. The oscillation power is found to be associated with magnetic-field strength and inclination, with different relationships in different frequency bands.

  • PDF

Clamp-meter for the power measurement (전력측정 클램프메타)

  • Park, Y.T.;Yu, G.M.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.296-298
    • /
    • 1999
  • 전압 전류, 유효전력. 무효전력. 피상전력. 역률, 진상. 지상 역률표시. 전력량을 측정할 수 있는 클램프메타의 개발에 관한 내용을 기술하였으며 제품화를 위한 시제품 제작과 그 특성을 시험한 결과 등을 나타내었다. 전류를 측정하는 클램프센서는 홀소자를 이용하였으며 선형도를 개선하기 위하여 홀소자를 2개 사용하였다. 결과에 의하면 현재 상품화되어있는 클램프메타보다 우수하며 전체 소비전력이 10 mA보다 적은 결과를 얻었다.

  • PDF

Implementation of Telemetry System using Two-Way Paging (양방향 페이징을 사용한 원격검침시스템 구현)

  • Park, Jong-Beom;Kim, Min;Kim, Hong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2723-2725
    • /
    • 2003
  • The research on Automatic Meter Reading(AMR) using PSTN. Power Line and Wireless network, is currently lead by the utilities, and it is intended to improve the ordinary manual reading method, so more accurate reading and management can be achieved. In this thesis, AMR system based on two-way paging was studied.

  • PDF

The diagnosis and appropriate reducing method on the harmonics for the induction motor installed inverter system (저압인버터를 적용한 펌프모터의 고조파 분석 및 저감방안)

  • Kim, Gi-Tae;Lee, Eun-Chun;Lee, Kyong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2056-2057
    • /
    • 2007
  • Recently we installed inverter system in $ind{\acute{u}}ction-m{\acute{o}}tor$ for the energy saving. But inverter system generates harmonics, and it causes a lot of issues. malfunction of meter, damage of instrument, overheating of motor. In this study, you can see how to deal with harmonics of inverter system by diagnosis of the power quality.

  • PDF

Evaluation System of the Thermal Properties of the Exothermic Agents (발열 보온재의 특성평가 시스템 구축)

  • Shin, D.Y.;Kim, D.J.;You, B.D.;Kim, N.S.;Oh, S.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.46-51
    • /
    • 2008
  • In this study, evaluation system of the thermal properties of the exothermic agents was investigated. Exothermic agents property evaluation system was developed by metering variation of power supply. Thermal properties of exothermic agents was affected by material mixture condition of exothermic agents, however, it was not affected by temperature. It is possible to make various exothermic agents by means of regulating thermal properties which is based on property evaluation system of exothermic agents.

  • PDF

A Study on the Monitoring System for Engine Control by Measuring Combustion Pressure Continuously in All Cylinders

  • Miharat Yoshinori;Maruyama Yasuo;Okada Yutaka;Kido Hachiro;Nishida Osami;Fujita Hirotsugu;Ito Masakazu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.713-721
    • /
    • 2005
  • A marine diesel engine should realize optimal operation efficiency while reducing NOx, PM (Particulate Matters) and other emissions. Fuel injection systems that use electronic control can become an effective means of achieving that objective. However. it still needs some accurate and instant information in order to bring its ability into full potential while sailing on the sea. The important information of them are a shaft torque and continuous combustion pressures of all cylinders. The shaft torque and the propeller thrust described in this paper are measured at an intermediate shaft by using a unique principle that one of two electromagnet coils oscillates a vibrating strip which the length changes with force and the other coil picks up the change of the frequency of the vibrating strip. For further reference, the shaft power meter multiplied the torque by the shaft revolution has already had about 750 sets of sales performance. The research presented in this paper started about ten years ago and is concerned with the development of a combustion pressure sensor that uses the same principle. Recently, the pressure sensor which bears continuous operation has been developed after a hard struggle, that is, the system that consists of a shaft horsepower meter, a propeller thrust meter and a combustion pressure sensor has been completed and has been shown to be reliable. This paper describes the configuration of this system, the material of the combustion pressure sensor, the principle of that, and the improving point of the sensor, and, we finally consider the use of this system.

Relation with Activity of Road Mobile Source and Roadside Nitrogen Oxide Concentration (도로이동오염원의 활동도와 도로변 질소산화물 농도의 관계)

  • Kim, Jin Sik;Choi, Yun Ju;Lee, Kyoung Bin;Kim, Shin Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.1
    • /
    • pp.9-20
    • /
    • 2016
  • Ozone has been a problem in big cities. That is secondary air pollutant produced by nitrogen oxide and VOCs in the atmosphere. In order to solve this, the first to be the analysis of the $NO_x$ and VOCs. The main source of nitrogen oxide is the road mobile. Industrial sources in Seoul are particularly low, and mobile traffics on roads are large, so 45% of total $NO_x$ are estimated that road mobile emissions in Seoul. Thus, it is necessary to clarify the relation with the activity of road mobile source and $NO_x$ concentration. In this study, we analyzed the 4 locations with roadside automatic monitoring systems in their center. The V.K.T. calculating areas are set in circles with 50 meter spacing, 50 meter to 500 meter from their center. We assumed the total V.K.T. in the set radius affect the $NO_x$ concentration in the center. We used the hourly $NO_x$ concentrations data for the 4 observation points in July for the interference of the other sources are minimized. We used the intersection traffic survey data of all direction for construction of the V.K.T. data, the mobile activities on the roads. ArcGIS application was used for calculating the length of roads in the set radius. The V.K.T. data are multiplied by segment traffic volume and length of roads. As a result, the $NO_x$ concentration can be expressed as linear function formula for V.K.T. with high predictive power. Moreover we separated background concentration and concentrations due to road mobile source. These results can be used for forecasting the effect of traffic demand management plan.

Preservative characteristics of photographic films and papers on the speed method (사진용 필름, 인화지의 감도측정에 따른 보존특성)

  • Ahn, Hong-Chan;Han, Sang-Wan;Choi, Hoon-Jeong;Heo, Hoon
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.3 no.2
    • /
    • pp.143-155
    • /
    • 2003
  • As archives, photograph is the evident records of historical facts and experiences. Thus, it is worth preserving. Unlike other documents silver halide photographic films and prints are quite sensitive to environmental factors such as light, temperature and humidity, which demands careful treatment in preservation. This study was carried out to select popular photographic films and papers on the market, to examine their photographic speeds (or sensitivities) and to compare and analyze their preservative features after keeping them some time in a weather-o-meter. Consequently, B/W materials were superior to color ones in preservation. And films were better than papers in the same manner. But we were not able to observe remarkable differences among material's manufacturers.

Development of Automatic Evaluation Equipment for Burden of Instrument Transformer using Resistor Simulator (저항기를 이용한 계기용 변성기 부담 자동 평가 장치 개발)

  • Lee, Young Seob;Jung, Jae Kap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.589-595
    • /
    • 2014
  • The error of instrument transformers is measured by connecting the external burden with the secondary terminal of the instrument transformers. Because the error of transformer is affected by the apparent power and power factor of the external burden, an accurate measurement of burden is important for transformer evaluation. We have developed the burden evaluation equipment for both potential transformer and current transformer by employing the series resistor in the range of $20m{\Omega}{\sim}5{\Omega}$ and the parallel resistor in the range of $1M{\Omega}{\sim}500{\Omega}$, respectively, together with visual basic program. We could reduce testing time more than 5 times by employing method developed in this study, compared with that developed in past. This method shows more better reliability by analyzing the evaluation results and fitting graphs of burden measurements. The test results of the developed system is compared with those obtained in the power meter analyzer to verify the validity.

Development of Matlab/Simulink Module for Voltage Flicker Simulation in Distribution Power Systems

  • Cho, Soo-Hwan;Jung, Jae-Ahn;Jang, Gil-Soo;Kwon, Sae-Hyuk;Kang, Moon-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.314-319
    • /
    • 2008
  • Power quality simulation plays an important role in many practical cases, for example, when deciding the capacity of the related mitigation devices, assessing the influence of installing a nonlinear load in the distribution part, dissolving the quality issues between utilities and customers, and so on. For these purposes, many dedicated tools have been used in order to assess the level of quality distortions by various kinds of PQ indices. However, there are few modules that can accurately simulate the flicker phenomenon, that is, $P_{st}$ and the nonlinear and chaotic behavior of the electrical arc furnace, which is one of the representative nonlinear loads. This paper deals with the useful and simple modules for the voltage flicker simulation in the distribution and transmission level under the environment of Matlab/Simulink. With these modules, the various conditions of distribution systems and the capacities of arc furnaces with the chaotic characteristic can be easily taken into account.