Reorganization trend on technical regulation of harm prevention for Power Line Communication (전력선통신 위해방지 기술기준의 개편 동향)

  • Cho, Pyung-dong;Choi, Mun-hwan;Lee, Sang-mu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1071-1074
    • /
    • 2015
  • Technical regulation of harm prevention for power line communication prescribes the technical matters to protect human and other equipment from power line communication equipment. Unified operation of technical regulation of power line communication and line facility installation is more efficient in content. This paper is to discuss the technical background of national PLC system and the direction of reforming related techinal regulations.

  • PDF

Security Monitoring System for Apartment House Building Using Paver Line Carrier (전력선 통신을 이용한 집단주택 안전관리 시스템)

  • Kim, In-Soo;Kim, Kwan-Ho;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.476-478
    • /
    • 1993
  • Instead of installing new communication wiring to each house in the apartment house building. the power distribution network. which is already installed in the building. can be use as communication medium. In a safty management, by adoption of power line communication system, at remote we can monitor safty related sensors such as fire, gas leakage, burglar intrusion and emergency call which are located at each house. From this viewpoint, we developed security monitoring system for apartment house building using power lines. Security monitoring system consists of Power Line Communication-Sub Controller (PLC-SC). Power Line Communication-Main Controller (PLC-MC) and Management System (MS). Between a PLC-MC and a PLC-SC, the transmission rate is 1200 bps in power lines and modulation technique is frequency shirt keying (FSK). In between a PLC-MC and a MS, the transmission rate is 1200 bps in communication line (RS-485). As a result of this research. transmission loss is 0.1dB per meter of intrabuilding distribution network. Transmission can be reach in 250 meters. So it is enough to communicate for security monitoring system in apartment house building.

  • PDF

Characteristics of the Voltages between the Communication Lines and Ground Induced by the Adjacent Artificial High-Voltage or Current ELF Source

  • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyung-Dong;Eun, Chang-Soo;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.4
    • /
    • pp.175-181
    • /
    • 2009
  • The measurements were performed to verify experimentally that the voltage arising on a telecommunication line by a power line is due to the induction phenomena because there has been an opinion that the arising voltage on a telecommunication line is not by induction, but by other causality. The voltage appeared on the telecommunication line by way of an electric field or magnetic field generated by the source apparatus that had been artificially made to provide intentional constant high-voltage or current in ELF, that is, 60 Hz as an emulated commercial power.

Analysis on Technical Standard for High Speed Power Line Communications (국내 고속전력선통신 도입을 위한 기술기준 분석)

  • Jang, Dong-Won;Cho, Pyung-Dong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.3 no.2
    • /
    • pp.26-32
    • /
    • 2004
  • This paper represents analysis on domestic technical regulation of high speed power line communications(PLC). Also it gives comparison of regulations for several countries which include U.S., Europe, and Japan. Power line communications radiates harmful interference in below 30MHz. This may intervene other radio equipments. The technical regulation must protect interference and provide clean radio environment. Finally this paper gives the proposal which is drafted by field tests for introducing high speed PLC.

  • PDF

Electromagnetic Induction Voltage according to the Position of Telecommunication Line from the Power Feeding Plant of Electrified Railway System (전기철도의 급전소 위치 관계에 따른 통신선 전자유도 전압)

  • Lee, Sangmu;Choi, Munhwan;Cho, Pyung-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.689-692
    • /
    • 2015
  • That induced voltage by an electrified railway line is related with the position of telecommunication line between traction power feeding systems is practically varified by measurements in the real field. This experimented fact is conformed with the calculated simulation provided by the ITU-T Directives concerning the protection of telecommunication lines against harmful effects from electric power and electrified railway lines. Therefore it is needed to consider at what position a telecommunication line is parallelized with power feeding line of traction system when an induction phenomenon is evaluated or measurement is carried out besides the length of parallelization and the separate distance between power line and telecommunication line.

  • PDF

A Study on the Implementation of Geographic Information System for an Intelligent Power Distribution Network with Location Informations of Power Line Communication-based Automatic Meter Reading System (전력선통신 기반 저압원격검침 시스템의 공간 정보를 활용한 지능형 배전망 지리정보시스템 구축에 관한 연구)

  • Seo, Chung-Ki;Lee, Seung-Gol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.365-369
    • /
    • 2015
  • In this paper, geographic information system(GIS) for an intelligent power distribution network was implemented with location informations acquired from automatic meter reading system, where the location informations of power line communication(PLC) modems installed at customer side were collected at data concentration units(DCUs) of headend equipment via PLC and then were transmitted to front end processor server. By displaying the connection status of the power distribution network on GIS map, operation of advanced metering infrastructure(AMI) or management of power grid system could be performed intuitionally and in real time, because the configuration state of the power grid could be easily monitored. The feasibility of the proposed system was confirmed with the especially constructed laboratory-level test bed and the verification test of the system will be carried out for a real power distribution network.

Analysis on an Inducing Current Change between Railway Power Feeding Plants (전기철도 전자기 유도 전류의 급전구간 상대적 위치 관계에 따른 변화 분석)

  • Lee, Sangmu;Choi, Mun Hwan;Cho, Pyung-dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.567-569
    • /
    • 2012
  • An inducing current of power feeding line of high-speed railway system is varied by a relative position of telecommunication cable to the feeding line between plants. An analytical calculation formula of this inducing current is described in ITU-T Directives using multiconductor line method or two line method. In this paper, using the two line method, a variation characteristic of inducing current is simulated. The inducing current has a characteristic of hyperbolic function which is a symmetric shape of curve in the range between power feeding plants. This basic variation property can be considered when a power induction protection measure is planned.

  • PDF

Power Reflection and Transmission Coefficients for Meander-Line Polarizers with a Chiral Slab

  • Delihacioglu, Kemal;Uckun, Savas
    • ETRI Journal
    • /
    • v.25 no.1
    • /
    • pp.41-48
    • /
    • 2003
  • This paper presents a theoretical investigation of power reflection and transmission coefficients for a meander-line polarizer placed periodically on a chiral slab. It is assumed that a linearly polarized transverse magnetic wave is incident on a chiral slab from the air region. In the analysis, we derive the electric and magnetic fields in the modal form in the air and chiral regions. We obtain power reflection and transmission coefficients in a straightforward manner after matching the tangential components of the electric and magnetic fields at the boundaries. We present numerical results for the power reflection and transmission coefficients versus frequency and incident angle for different values of the chirality admittance. A meander-line polarizer placed on a dielectric slab can convert a linearly polarized wave to a circularly polarized wave. The design parameters for a meander-line polarizer are the dimensions of the meander-line and the values of the dielectric slab. Replacing a dielectric slab with a chiral slab introduces a new independent parameter which controls the wave polarization.

  • PDF

2.4-GHz Power Amplifier with Power Detector Using Metamaterial-Based Transformer-Type On-Chip Directional Coupler

  • Dang, Trung-Sinh;Tran, Anh-Dung;Lee, Bomson;Yoon, Sang-Woong
    • ETRI Journal
    • /
    • v.35 no.3
    • /
    • pp.554-557
    • /
    • 2013
  • This letter presents a power amplifier (PA) with an on-chip power detector for 2.4-GHz wireless local area network application. The power detector consists of a clamp circuit, a diode detector, and a coupled line directional coupler. A series inductor for an output matching network in the PA is combined with a through line of the coupler, which reduces the coupling level. Therefore, the coupler employs a metamaterial-based transformer configuration to increase coupling. The amount of coupling is increased by 2.5 dB in the 1:1 symmetric transformer structure and by 4.5 dB from two metamaterial units along the coupled line.

Design and Fabrication of 25 W Ka-Band SSPA Based on GaN HPA MMICs (GaN HPA MMIC 기반 Ka 대역 25 W SSPA 설계 및 제작)

  • Ji, Hong-gu;Noh, Youn-sub;Choi, Youn-ho;Kwak, Chang-soo;Youm, In-bok;Seo, In-jong;Park, Hyung-jin;Jo, In-ho;Nam, Byung-chang;Kong, Dong-uk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.12
    • /
    • pp.1083-1090
    • /
    • 2015
  • We designed and manufactured Ka-band SSPA include drive amplifier and high power amplifier MMICs by $0.15{\mu}m$ GaN commercial process. Also, we fabricated main components micro-strip line to WR28 waveguide transition and WR28 wave guide power combiner for Ka-band SSPA. This Ka-band SSPA shows saturated output power 44.2 dBm, power added efficiency 16.6 % and power gain 39.2 dB at 29~31 GHz frequency band.