Analysis on an Inducing Current Change between Railway Power Feeding Plants

전기철도 전자기 유도 전류의 급전구간 상대적 위치 관계에 따른 변화 분석

  • Lee, Sangmu (Electronics and Telecommunications Research Institute) ;
  • Choi, Mun Hwan (Electronics and Telecommunications Research Institute) ;
  • Cho, Pyung-dong (Electronics and Telecommunications Research Institute)
  • Published : 2012.10.26

Abstract

An inducing current of power feeding line of high-speed railway system is varied by a relative position of telecommunication cable to the feeding line between plants. An analytical calculation formula of this inducing current is described in ITU-T Directives using multiconductor line method or two line method. In this paper, using the two line method, a variation characteristic of inducing current is simulated. The inducing current has a characteristic of hyperbolic function which is a symmetric shape of curve in the range between power feeding plants. This basic variation property can be considered when a power induction protection measure is planned.

전기철도 급전선에 흐르는 기유도전류를 계산하는 방법은 ITU-T의 지침서에 다도체 계산법으로 제시되어 있고 급전선 특성에 의한 전파상수 및 전차선 전류의 계산에 관하여는 이도체 해석 방법으로 계산하도록 되어 있다. 본 논문에서는 특히 급전 구간내에서도 전차 및 통신선의 상대적 위치 관계에 따른 기유도전류의 변화를 ITU에서 제시한 방식에 의하여 국내 전차선 전파상수 특성 파라미터를 부여하고 전차의 이동에 따라 어떠한 변화를 나타내는지 시뮬레이션을 통하여 분석하여 보았다. 급전구간내에서 변화하는 기유도전류는 급전소 간에 대칭적 쌍곡선 함수 특성으로 나타남을 알수 있고 이러한 해석 결과는 급전소간의 유도 영향 관계에서 통신선 장애에 대응하는 데에 기초적 영향 변수로 활용될 수 있다.

Keywords