• Title/Summary/Keyword: power line

Search Result 6,050, Processing Time 0.035 seconds

A Study on the Self-Healing Mechanism using Spanning Tree Algorithm for PLC-based Home Network (전력선 홈 네트워크를 위한 스패닝 트리 알고리즘 기반의 자동 중계 기술 연구)

  • Hwang, Min-Tae;Choi, Sung-Soo;Lee, Won-Tae
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.7
    • /
    • pp.986-996
    • /
    • 2008
  • The home network environment based on the power line communication has some unexpected events. The noise source from the home appliances makes the network impedance increased, and the transmission packets distorted. Therefore the packet transmission from the source node may not be delivered to the destination node directly. In this paper we propose a new self-healing mechanism which relays the packet to the directly unreachable destination automatically with the help of intermediate nodes. In order to choose the minimum required intermediate nodes our mechanism makes a spanning tree with both the directly reachable nodes and indirectly reachable nodes via the intermedia nodes. We developed the network simulator in order to compare its performance to the Echelon's repeater selecting mechanism. Though it required more packet relations than Echelon's but the reachable probability to the destination was highly increased about two times.

  • PDF

Implementation of the Disaster Monitering System with PLC/CDMA Environments (PLC/CDMA 환경에서의 재난 감시 시스템 구현)

  • Park, Sang-Hwan;Kim, In-Min;Yoon, Seon-Tae;Park, Ki-Won;Go, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.824-830
    • /
    • 2010
  • PLC_Zigbee system, implemented in a previous study, uses ZigBee Node based on PLC (Power Line Communication). The weak point of the system is that the long distance powerline communication and PLC is impossible to use in the areas where the powerline is not installed. In this paper, we added CDMA (Code Division Multiple Access) module using a data transfer method of SMS (Short Message Service) and XBee of WSN (Wireless Sensor Network) module to the previous system, and got around the restriction of place and environment of PLC system through the interfacing of each communication media. We, thus, implemented a wide range of real monitoring system.

Fatigue performance and life prediction methods research on steel tube-welded hollow spherical joint

  • Guo, Qi;Xing, Ying;Lei, Honggang;Jiao, Jingfeng;Chen, Qingwei
    • Steel and Composite Structures
    • /
    • v.36 no.1
    • /
    • pp.75-86
    • /
    • 2020
  • The grid structures with welded hollow spherical joint (WHSJ) have gained increasing popularity for use in industrial buildings with suspended cranes, and usually welded with steel tube (ST). The fatigue performance of steel tube-welded hollow spherical joint (ST-WHSJ) is however not yet well characterized, and there is little research on fatigue life prediction methods of ST-WHSJ. In this study, based on previous fatigue tests, three series of specimen fatigue data with different design parameters and stress ratios were compared, and two fatigue failure modes were revealed: failure at the weld toe of the ST and the WHSJ respectively. Then, S-N curves of nominal stress were uniformed. Furthermore, a finite element model (FEM) was validated by static test, and was introduced to assess fatigue behavior with the hot spot stress method (HSSM) and the effective notch stress method (ENSM). Both methods could provide conservative predictions, and these two methods had similar results. However, ENSM, especially when using von Mises stress, had a better fit for the series with a non- positive stress ratio. After including the welding residual stress and mean stress, analyses with the local stress method (LSM) and the critical distance method (CDM, including point method and line method) were carried out. It could be seen that the point method of CDM led to more accurate predictions than LSM, and was recommended for series with positive stress ratios.

Design and Implementation of Wireless Asynchronous UWB System for low-rate low power PAN applications (저속도 저전력 PAN 응용을 위한 무선 비동기식 UWB 시스템 설계 및 구현)

  • Choi, Sung-Soo;Koo, In-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.11
    • /
    • pp.2021-2026
    • /
    • 2007
  • In the parer, we design a non-coherent UWB system by adopting the architecture of a simplified asynchronous transmission and the edge-triggered pulse transmission, which makes e system performance independent of the share of the transmitted waveform, robust to multipath channels. The designed non-coherent UWB transceiver architecture has an advantage of the simple realization since any mixer, high-speed correlator, and high-sampling A/D converter are not necessary at the cost of performance degradation of about 3dB. Further, the designed non-coherent UWB transceiver is actually implemented with the wireless CANVAS prototype testbed in short range indoor application environments such as a lecture room. The implemented prototype testbed is proven to offer the data rate of 115kbps on the conditions of Peer-to-Peer(P-to-P) in the indoor channel within the range of about 10m.

A Design of ADC with Multi SHA Structure which for High Data Communication (고속 데이터 통신을 위한 다중Multi SHA구조를 갖는 ADC설계)

  • Kim, Sun-Youb
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.9
    • /
    • pp.1709-1716
    • /
    • 2007
  • In this paper, ADC with multi SHA structure is proposed for high speed operation. The proposed structure incorporates a multi SHA block that consists of multiple SHAs of identical characteristics in parallel to improve the conversion speed. The designed multi SHA is operated by non-overlapping clocks and the sampling speed can be improved by increasing the number of multiplexed SHAs. Pipelined A/D converter, applying the proposed structure, is designed to satisfy requirement of analog front-end of VDSL modem. The measured INL and DNL of designed A/D converter are $0.52LSB{\sim}-0.50LSB$ and $0.80LSB{\sim}-0.76LSB$, respectively. It satisfies the design specifications for VDSL modems. The simulated SNR is about 66dB which corresponds to a 10.7 bit resolution. The power consumption is 24.32mW.

A Study on the Development of Power-Line EMI Filter for the Prevention of Conduction Noise by Coil Loads. (코일성 부하에 의한 전도 노이즈 방지 목적의 전원용 EMI필터 개발 연구)

  • Kim, Byeong Jun;Joo, Jae-hun;Kim, Jin Ae;Baek, Pan Keun;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.175-179
    • /
    • 2009
  • this paper proposes a filter design that makes to be satisfied EMC spec. in reliability test of analogue switch for electronic equipment and air conditioning load unit. A designed electromagnetic wave filter was applied to minimize an mutual interference and surrounding environment and improve the product's quality being satisfied to EMC standard. By simulation, using a spectrum analyzer at the 30MHz~1GHz band, ISO/JASO standard frequency range, and simplified EMI chamber, energy distribution of a specific frequency band was analyzed and the capacity of the element which composed the filter was determined in order to implement the most suitable electromagnetic wave filter.In fact, it was certificated that noise decrease by filter addition to the analogue switch for electronic equipment and air conditioning load unit in Certification Authority, and confirmed that the unit is carried out a normal action without electromagnetic wave interference.

  • PDF

A Development of Maintenance Decision Support System for Gas Turbine Engine (가스터빈 엔진 정비 의사결정 지원시스템 개발)

  • Ki, Ja-Young;Kang, Myoung-Cheol;Lee, Myung-Kuk;Rho, Hong-Suk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.586-591
    • /
    • 2012
  • The solution of maintenance decision support system for the gas turbine engine, which is currently operating in GUNSAN combined cycle power plant, was developed and is consist of online monitoring module, periodic performance trending module, optimal compressor washing interval analysis module and hot component management module. Also, GUI platform was applied to this solution for the user to monitoring the analyzed result of engine performance condition and then to make a decision of the consequent maintenance action. In online condition monitoring module, the performance degradation of engine is provided by the analysis of difference between the real time measurement data compared to exist engine performance. The optimal compressor washing interval module produced the washing interval of maximum net profit value by researching the maintenance expense and the loss profit value corresponds to the performance degradation with economic assessment algorithm. Thus, this solution support the user to enable the optimal maintenance and operation of gas turbine engine with overall analysis of engine condition and main information.

  • PDF

Analysis of Resonant Characteristics in High Voltage Windings of Main Transformer for Railway Vehicle using EMTP (EMTP를 이용한 철도차량용 주변압기 고압권선의 공진특성 분석)

  • Jeong, Ki-Seok;Jang, Dong-Uk;Chung, Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.436-444
    • /
    • 2016
  • The primary windings of the main transformer for rolling stock have several natural frequencies that can occur internal resonance with transient voltages induced on a high voltage feeding line. Factory testing is limited in its ability to determine whether or not transient voltage with various shape and duration can be excitable. This study presents the design of a high voltage windings model and simulation and analysis of the internal resonant characteristics in terms of the initial voltage distribution and voltage-frequency relationship using the electromagnetic transients program (EMTP). Turn-based lumped-parameters are calculated using the geometry data of the transformer. And, sub-models, being grouped into the total number of layers, are composed using a ladder-network model and implemented by the library function of EMTP. Case studies are used to show the layer-based voltage-frequency relationship characteristics according to the frequency sweep and the voltage escalation and distribution aspects in time-domain simulation.

Research on Development and Evaluation Tests of Movable Catenary System Using Rigid Bar for DC Feeding System (강체전차선을 이용한 직류전기철도용 이동식 전차선 시스템 개발 및 성능검증에 관한 연구)

  • Park, Seong-Hee;Jang, Dong-Uk;Kang, Seung-Wook
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.3
    • /
    • pp.356-364
    • /
    • 2017
  • The process of inspecting electric railway vehicles is complicated and these vehicles accompany a risk of safety accidents. This developed system will be a great help in simplifying the shunting process and be very useful in terms of ensuring safety and providing user convenience. In this paper, the results of performance evaluation tests are studied on a movable catenary system for railway vehicles that secured mechanical durability, convenience, and operator safety by applying a specific rigid bar catenary of an existing mobile train line. We presented an analysis of the basic characteristics for site installation including sorting. In conclusion, this developed system was obtained in good results through durability test, durable mechanical load test and safety test in require specifications.

Effects of post weld heat treatment conditions on localized corrosion resistance of super duplex stainless steel tube used for thermal power plant applications (화력발전용 슈퍼 듀플렉스 스테인리스 강 조관재의 용접 후 열처리 조건이 국부부식 저항성에 미치는 영향)

  • Lee, Jun Ho;Park, Jin sung;Cho, Dong Min;Hong, Seung Gab;Kim, Sung Jin
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.5
    • /
    • pp.248-259
    • /
    • 2021
  • This study examined the influence of post weld heat treatment (PWHT) conditions on corrosion behaviors of laser-welded super duplex stainless steel tube. Due to the high cooling rate of laser welding, the phase fraction of ferrite and austenite in the weld metal became unbalanced significantly. In addition, the Cr2N particles were precipitated adjacent to the fusion line, which can be susceptible to the localized corrosion. On the other hand, the phase fraction in the weld metal was restored at a ratio of 5:5 when exposed to temperatures above 1060 ℃ during the post weld heat treatment. Nevertheless, the high beltline speed during the PWHT, leading to the insufficient cooling rate, caused a precipitation of σ phase at the interface between ferrite/austenite in both weld metal and base metal. This resulted in the severe corrosion damages and significant decrease in critical pitting temperature (CPT), which was even lower than that measured in as-welded condition. Moreover, the fraction of σ phase in the center region of post weld heat treated steel tube was obtained to be higher than in the surface region. These results suggest that the PWHT conditions for the steel tube should be optimized to ensure the high corrosion resistance by excluding the precipitation of σ phase even in center region.