• Title/Summary/Keyword: power distribution line

Search Result 812, Processing Time 0.027 seconds

Development of the equipment for detecting the poor power facilities by receiving electric noises (전자파 잡음을 이용한 전기설비 불량 검출장치 개발)

  • 이복규;강성철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1356-1359
    • /
    • 1997
  • There are various methods to detect the faulty electric facilities(esp, insulator) indirectly on power distribution lines at a certain distance apart. This paper describes the proto type equipment to detect a faulty insulator by receiving a electric discharge noises, which are generated with a periodicity of 120Hz.

  • PDF

Identification of Energized status of Underground Power Cable (지중 전력 케이블 가압 상태 진단)

  • 김창교;홍진수;정영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.69-72
    • /
    • 1998
  • A study to identify the energized status of the 22.9kV underground power cable by the detection of vibration was reformed. We derived that there exists vibration at double the line frequency in live cables by electromagnetic force. The vibration can be picked up by accelerometer sensor. A prototype was tested on the underground distribution system in Chonan Station, KEPCO. The results are presented and suggest the applicability of the detecting device.

  • PDF

Technical Problems and solution based on Connection of Ullung Wind Power Plant into Power Distribution System (울릉도 풍력발전 계통연계 문제점 및 대책)

  • Yoon, G.G.;Lee, W.S.;Kim, B.H.;Lee, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.305-307
    • /
    • 2001
  • The wind power equipment of Ullung island is composed of a hybride type of wind powers and diesel generators. The wind power generation in Ullung island is, howerever, not smooth due to the small capacity and weekness of existing power systems and line. Therefore, it is the purpose of this study to describe the technical problems and its solution through the investigation of actual conditions.

  • PDF

The Consideration of the Development Testing for LED type In-pavement Aeronautical Lights (LED형 매립형 항공등 시스템의 개발 시험에 대한 고찰)

  • Lee, Sang-Cheol;Shin, Jae-Heung;Lee, Seung-Youn;Lim, Keun-Young;Lim, Min-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.3
    • /
    • pp.140-148
    • /
    • 2012
  • Aeronautical lights, which are internationally standardized sequence of colors and placements, are aeronautic safety devices that provide visual information to pilots by continuously adjusting their light intensity to appropriate level. In this paper, we consider the development testing for in pavement LED aeronautical light system such as taxiway centerline, stop line and temporary stop line. The test results of LED sourced lights have shown a drastic improvement in power consumption levels and cost efficiency compared to their halogen sourced counterparts The LED light used only 42.7% as much power as their halogen sourced counterparts. Taking installation costs into account, LED will cost only 58% of its halogen counterparts. These results suggest that developing the LED sourced aeronautical light would result in globally competitive products thar guarantees satisfaction to their consumers, and that both cost effective and energy efficient.

Numerical Analysis of Loss Power Properties in the Near-Field Electromagnetic Wave Through A Microstrip Line for Multilayer Magnetic Films with Different Levels of Electrical Conductivity

  • Lee, Jung-Hwan;Kim, Sang-Woo
    • Journal of Magnetics
    • /
    • v.13 no.3
    • /
    • pp.92-96
    • /
    • 2008
  • There are few reports of high frequency loss behavior in the near-field for magnetic films with semiconducting properties, even though semiconducting magnetic materials, such as soft magnetic amorphous alloys and nanocrystalline thin films, have been demonstrated. The electromagnetic loss behavior of multilayer magnetic films with semiconducting properties on the microstrip line in quasi-microwave frequency band was analyzed numerically using a commercial finite-element based electromagnetic solver. The large increase in the absorption performance and broadband characteristics of the semiconducting/insulating layer magnetic films examined in this study were attributed to an increase in the loss factor of resistive loss. The electromagnetic reflection increased significantly with increasing conductivity, and the loss power deteriorated significantly. The numerical results of the magnetic field distribution showed that a strong radiated signal on the microstrip line was emitted with increasing conductivity and decreasing film thickness due to re-reflection of the radiated wave from the surface of the magnetic film, even though the emitted levels varied with film thickness.

DYNAMICAL CHARACTERISTICS OF SUNSPOT CHROMOSPHERES II. ANALYSIS OF CA II H, K AND ${\lambda}8498$ LINES OF A SUNSPOT (SPO 5007) FOR OSCILLATORY MOTIONS

  • Yoon, Tae-Sam;Yun, Hong-Sik;Kim, Jeong-Hoon
    • Journal of The Korean Astronomical Society
    • /
    • v.28 no.2
    • /
    • pp.245-253
    • /
    • 1995
  • We have analyzed the time series of Ca II H,K and ${\lambda}8498$ line profiles taken for a sunspot (SPO 5007) with the Echelle spectrograph attached to Vacuum Tower Telescope at Sacramento Peak Solar Observatory. Each set of spectra was taken simultaneously for 20 minutes at a time interval of 30 seconds. A total of 40 photographic films for each line was scanned by a PDS at Korea Astronomy Observatory. The central peak intensity of Ca II H ($I_{max}$), the intensity measured at ${\Delta}{\lambda}=-0.1{\AA}$ from the line center of ${\lambda}8498(I_{{\lambda}8489})$, the radial velocity ($V_r$) and the Doppler width (${\Delta}{\lambda}_D$) estimated from Ca II H have been measured to study the dynamical behaviors of the sunspot chromosphere. Fourier analysis has been carried out for these measured quantities. Our main results are as follows: (1) We have confirmed the 3-minute oscillation being dominant throughout the umbra. The period of oscillations jumps from 180 sec in the umbra to 500 to 1000 sec in the penumbra. (2) The nonlinear character of the umbral oscillation is noted from the observed sawtooth shaped radial velocity fluctuations with amplitudes reaching up to $5{\sim}6\;km/sec$. (3) The spatial distribution of the maximum powers shows that the power of oscillations is stronger in the umbra than in the penumbra. (4) The spatial distributions of the time averaged < $I_{max}$ > and < $V_r$ > across the spot are found to be nearly axially symmetric, implying that the physical quantities derived from the line profiles of Ca II H and ${\lambda}8498$ are inherently associated with the geometry of the magnetic field distribution of the spot. (5) The central peaks of the CaII H emission core lead the upward motions of the umbral atmosphere by $90^{\circ}$, while no phase delay is found in intensities between $I_{max}$ and $I_{{\lambda}8498}$, suggesting that the umbral oscillation is of standing waves.

  • PDF

Design Methodology of the Bus Configuration and Protection Coordination Basic Logics of Power Substation Using EMTP-RV (EMTP-RV를 이용한 변전소 모선 방식과 보호협조 기초 논리 설계 방법론에 대한 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1129-1138
    • /
    • 2019
  • Since substations are structurally complex due to the concentration of protection coordination facilities with substation facilities for long distance power transmission, it is difficult to design a protection coordination system to minimize the spreading effect of the fault when a fault occurs on transmission line or distribution line. Therefore, in this paper, the bus configuration and the basic logic of protection coordination that have a major influence on the reliability of substation power supply were analyzed, and the substation protection coordination logic to detect internal and external faults was developed based on EMTP-RV. As the basic logic of substation protection coordination, the percent differential protection relay logic for substation internal fault detection and the overload protection relay logic for inference of external failure were modeled. Finally, the 154kV substation including the protection coordination logic was modeled using EMTP-RV, and the effectiveness of the protection coordination design methodology was confirmed through the several fault simulation cases based on EMTP-RV.

A Novel Three-Phase Four-Wire Shunt Active Filter to Eliminate Neutral Current (高調波 中性電流를 低減시키기 위한 3相4線 竝列形 能動필터에 關한 硏究)

  • 고경수;김래기;유권종;송진수;김시경
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.184-190
    • /
    • 1998
  • Most buildings and factories are supplied with electric power by three-phase four-wire low voltage electric distribution system. This method pollutes the neutral line and utility sources with harmonic currents. Today, development of power conversion technology and the popularization of computer cause the neutral current to become serious. In this paper, a novel three-phase four-wire active filter is proposed to solve these harmonic problems has two purposes. The first purpose of the proposed active filiter is that the phase current has a sinusoidal waveform shape under the nonlinear load. The second purpose of the proposed active filiter is that the current on the neutral line become zero under the unbalanced power source and under the varring load conditions. The ability of the shunt active filiter has been proved to be excellent through simulations under the varring load conditions.

  • PDF

Various Factors Influencing the Lifetime of Suspension-Type Porcelain Insulators for 154 kV Power Transmission Lines

  • Choi, In Hyuk;Park, Joon Young;Kim, Tae Gyun;Yoon, Yong Beum;Yi, Junsin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.151-154
    • /
    • 2017
  • In this article, we investigated the various influencing factors that degraded the lifetime of suspension insulators in 154 kV transmission lines, and showed the possible solutions to avoid such breakdowns. With respect to achieve safety, reliability and aesthetical considerations, the characteristics of transmission and distribution network power cables should be improved. Suspension insulators are particularly important to study, as they have developed to be the main component of transmission lines due to their ability to withstand the electrical conductivity of high-voltage power transmission. Suspension insulators are mostly made from glass, rubber and ceramic material due to their high resistivity. In Korea, porcelain suspension insulators are typically used in the transmission line system, as they are cheaper and more flexible compared to other types of insulators. This is effective from preventing very high and steep lightening impulse voltages from causing the breakdown of suspension insulators used in power lines. Other influential factors affect the lifetime of suspension insulators that we studied include temperature, water moisture, contamination, mechanical vibration and electrical stress.

Study on Simulation of Dust Diffusion at Open Pit Mines (노천광산의 발파분진 비산영역 예측에 관한 연구)

  • 김복윤;이상권;조영도;김임호
    • Tunnel and Underground Space
    • /
    • v.8 no.3
    • /
    • pp.194-199
    • /
    • 1998
  • This research was aimed to figure out the trend of dust diffusion at open pit limestone mine for assessing the environmental impacts on the high voltage power transmission line. It is rather easy to assess the dust generation and size distribution of limestone dust at the blasting site, but it is very hard to assess the expected area of dust diffusion and amount of dust fall by the distances from the dust source. In this research, a 3-dimensional fluid dynamic simulation software (3D-Flow) was used for analysing the above mentioned matters to assess the impacts to the insulators on the transmission tower by the blasting dust. It was verfied that the 3D-Flow is reliable tool for simulating dust movement, and the limestone dust is not much hazardous to the power transmission line.

  • PDF