• Title/Summary/Keyword: power conditioning

Search Result 1,094, Processing Time 0.023 seconds

Acoustical Characteristics of System Air Conditioners Installed in the Ceiling (천장형 시스템 에어컨의 음향 특성)

  • Kim, Su-Yeon;You, Jin;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.662-665
    • /
    • 2005
  • In this study acoustical characteristics of system air conditioner in different ceiling systems was investigated in anechoic and real conditions. Same Types of air conditioners were installed in two different rooms. The results showed that motor's tonal component was emphasized at near fart of air blast blower in the exposed type while fan's harmonic component is emphasized rather in the enclosed type. This confirms tile result of acoustical intensity mapping which showed that Intensity level of 125Hz octave band increased in the exposed type while there was no noticeable difference at the frequency band in the enclosed type.

  • PDF

Time Domain Analysis of Digital Filters for Noise Cancelling in ECG Signals (ECG신호의 잡음 제거를 위한 디지탈 필터의 시간 영역 해석)

  • Nam, Hyun-Do;Ahn, Dong-Jun;Lee, Cheol-Heui
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.137-145
    • /
    • 1993
  • Time domain analysis as well as frequency domain analysis of signal conditioning filters is very useful for practical applications. Time domain analysis of digital filters for noise cancelling in ECG signals is presented. Several band pass and band reject filters are designed for the analysis. Computer simulations are performed to compare the distortions of the Butterworth type filters and linear phase optimal FIR filters which are widely used for ECG signal processing. Band reject filters are applied to power line interference cancelling in ECG signals.

  • PDF

Load torque compensaiton algorithm for single rotray compressor of air conditioning system (Single rotary compressor의 저진동 저속제어를 위한 자동 부하 보상 알고리즘)

  • Gu, Bon-Gwan;Choi, Jun-Hyuk;Jung, In-Soung
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.320-322
    • /
    • 2010
  • 저용량 에어컨의 압축기에 많이 사용되는 Single rotary 방식은 하나의 피스톤만을 채용하여 가격적인 면에서 큰 이점을 가진다. 그러나, 압축기 모터가 1회전할때 마다 압축과 토출을 단 1회 거치게 되므로, 부하변동을 심하여 진동이 많이 발생하는 단점이 있다. 이러한 단점을 보완하기 위하여 Single rotary를 사용하는 에어컨 제품에서는 저속에서의 운전을 회피하거나 하나의 운전점에 대한 전향보상기를 채용하여 진동을 저감시켜 왔다. 본 논문에서는 모든 운전점에서 보상이 가능하도록 압축과 토출로 인한 부하의 패턴에서 각 주파수 성분을 분석하여 자동으로 부하 토크를 보상하는 알고리즘을 제안한다. 제안된 방법은 가장 영향이 큰 1차와 2차 주파수 성분의 속도 리플의 양을 FFT 하고, 그 양이 작아지는 방향으로 부하 토크를 전향 제어방식으로 인가하는 방식이다. 제안된 방식을 이용하여 저속 운전에서 진동이 저감 되는것을 실험을 통하여 보였다.

  • PDF

Cooling Performance of a Hybrid Refrigeration System for Telecommunication Equipment (통신기기 냉각용 하이브리드 냉방시스템의 성능특성)

  • Jeon, Jong-Ug;Kim, Yong-Chan;Choi, Jong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.489-494
    • /
    • 2006
  • Electronic and telecommunication industries are constantly trying to develop compact components having high power density. Therefore, a proper heat dissipation method is very important to allow reliable operation of the telecommunication equipment. In this study, a hybrid refrigeration system for a telecommunication equipment room was designed to save energy consumption and improve reliability of the compressor In addition, the performance of the hybrid refrigeration system was measured with a variation of outdoor load. The designed hybrid refrigeration system for the telecommunication equipment shelter saved the energy approximately 50%e at the mode switch temperature of $8.3^{\circ}C$.

  • PDF

Investigation of the Cooling Performance Using Pottier Module (펠티에 소자를 이용한 냉각성능에 관한 연구)

  • Lee, Sang-Il;Choi, Jin-Wook;Lee, Dong-Ryul
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1156-1161
    • /
    • 2006
  • This study is to evaluate the cooling performance of the Bonding type and Injection type of heat sink using three different kinds of industrial Peltier module by digital $LabView^{TM}$ measurement. Injection type of heat sink could be more efficient for the heat transfer than Bonding type, even with 30% more radiating surface area. In addition, the experimental results revealed that the sufficient power supplied was able to show the better cooling performance of Peltier module.

  • PDF

On propagation of elastic waves in an embedded sigmoid functionally graded curved beam

  • Zhou, Linyun;Moradi, Zohre;Al-Tamimi, Haneen M.;Ali, H. Elhosiny
    • Steel and Composite Structures
    • /
    • v.44 no.1
    • /
    • pp.17-31
    • /
    • 2022
  • This investigation studies the characteristics of wave dispersion in sigmoid functionally graded (SFG) curved beams lying on an elastic substrate for the first time. Homogenization process was performed with the help of sigmoid function and two power laws. Moreover, various materials such as Zirconia, Alumina, Monel and Nickel steel were explored as curved beams materials. In addition, curved beams were rested on an elastic substrate which was modelled based on Winkler-Pasternak foundation. The SFG curved beams' governing equations were derived according to Euler-Bernoulli curved beam theory which is known as classic beam theory and Hamilton's principle. The resulted governing equations were solved via an analytical method. In order to validate the utilized method, the obtained outcomes were compared with other researches. Finally, the influences of various parameters, including wave number, opening angle, gradient index, Winkler coefficient and Pasternak coefficient were evaluated and indicated in the form of diagrams.

Occupational Dose Analysis of Spent Resin Handling Accident During NPP Decommissioning

  • Hyunjin Lee;Chang-Lak Kim;Sang-Rae Moon;Sun-Kee Lee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.2
    • /
    • pp.247-253
    • /
    • 2023
  • According to NSSC Notice No. 2021-10, safety analysis needs to be introduced in the decommissioning plan. Public and occupational dose analyses should be conducted, specifically for unexpected radiological accidents. Herein, based on the risk matrix and analytic hierarchy process, the method of selecting accident scenarios during the decommissioning of nuclear power plants has been proposed. During decommissioning, the generated spent resin exhibits relatively higher activity than other generated wastes. When accidents occur, the release fraction varies depending on the conditioning method of radioactive waste and type of radioactive nuclides or accidents. Occupational dose analyses for 2 (fire and drop) among 11 accident scenarios have been performed. The radiation doses of the additional exposures caused by the fire and drop accidents are 1.67 and 4.77 mSv, respectively.

A Study of the Possibility of Building Energy Saving through the Building Data : A Case Study of Macro to Micro Building Energy Analysis (건물데이터를 통한 건물에너지 절감 가능성에 대한 연구 : 도시단위의 거시적 분석부터 미시적 건물에너지 분석사례)

  • Cho, Soo Youn;Leigh, Seung-Bok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.580-591
    • /
    • 2017
  • In accordance with 2015 Paris agreement, each individual country around the world should voluntarily propose not only its (individual) reduction target, but also actively develop and present expansion targets of its scope and concrete reduction goals exceeding the previous ones. Accordingly, it is necessary to prepare a macroscopic, long-range strategy for reducing energy consumption and greenhouse gas emissions, which can cover a single building, town, city and eventually even a province. The purpose of this research is to gather and compile government-acquired data from various sources and (in accordance with contents and specificity), combine building data by stages by using multi-variable matrix and then analyze the significance of combined data for each stage. The first order data presents the probability and the cost effectiveness of energy saving on the scale of a city or a province, based only upon general information, size and power consumption of buildings. The second order data can identify a pattern of energy consumption for a building of a specific purpose and which tends to consume a larger amount of energy during one particular season (than others). Finally, the third order data can derive influential factors (base load, humidity) from the energy consumption pattern of a building, and thus propose an informed and practical energy-saving method to be applied in real time.

Cooling Performance of Geothermal Heat Pump Using Surface Water Heat Exchanger (지표수 열교환기 적용 지열 히트펌프 시스템의 냉방 성능)

  • Lim, Hyo Jae;Kong, Hyoung Jin;Sohn, Byonghu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.316-326
    • /
    • 2017
  • Commercial buildings and institutions are predominantly cooled, thereby dissipating excess heat to a vertical ground heat exchanger (VGHE), than heat extracted over an annual cycle. Surface waters, such as lakes and ponds, provide a cost-effective means of reducing the VGHE length, and in balancing the thermal loads to the ground. This paper presents the measurement and analysis of the cooling performance of ground-coupled heat pump (GCHP) system, using surface water heat exchanger (SWHE) submerged in an artificial pond. In order to measure the performance of the system, we installed monitoring equipment, including sensors, for assessing the temperature and power consumption, after which the operation parameters were determined. The results from the thermal performance test for the SWHE indicate that the temperatures at the outlet of the SWHE and within the pond were affected by outdoor air temperature. In addition, the results reveal similar variation trends on temperatures; however, the peak temperatures of the SWHE were somewhat greater than those of outdoor air, due to the thermal capacity of the pond. Analyzing the cooling performance over the measurement period, the average coefficient of performance (COP) of heat pump was found to be 5.71, while that for the entire system was 2.99.

Heating Performance of Geothermal Heat Pump System Applied in Cold Climate Region(Mongolia) (한랭지(몽골) 지열 히트펌프 시스템의 난방 성능 분석)

  • Sohn, Byonghu;Choi, Jae Ho;Min, Kyung Chon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Geothermal heat pump (GHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. These systems use the ground as a heat source in heating mode operation and a heat sink in cooling mode operation. The aim of this study is to evaluate the heating performance of the GHP system for a residential building ($420m^2$) in Ulaanbaatar, Mongolia. In order to demonstrate the feasibility of a sustainable performance of this system, we installed the water-to-water geothermal heat pump with ten vertical ground heat exchangers and measured operation parameters from October 19, 2013 to March 26, 2014. The results showed that the entering source temperature of brine from the ground heat exchangers was in a range of the design target temperature of $-10^{\circ}C$ for heating. For total values of the representative results, the ground heat exchangers extracted heat of 53.51 MWh from the ground. In addition, the GHP system supplied heat of 83.55 MWh to the building and consumed power of 30.27 MWh. Consequently, the average heating seasonal performance factor ($SPF_h$) of the overall system was evaluated to be 2.76 during the measurement period of the heating season.