• Title/Summary/Keyword: post core

Search Result 527, Processing Time 0.02 seconds

COLOR COMPARISON OF VARIOUS POST SYSTEMS WITH EMPRESS 2 CROWNS (포스트의 종류에 따른 Empress 2 도재관의 색상에 관한 비교연구)

  • Lee Young-Soo;Yoo Dong-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.197-207
    • /
    • 2001
  • Development of new ceramics and esthetic needs of patients increase the use of all ceramic restorations. Fractured teeth often need metal post and core as foundation for final restoration. When all ceramic restorations are planned, metal post and core may lead to compromised esthetics because of opacity and gray color of metal post and core. Many techniques have been proposed to solve this problem such as application of an opaque porcelain to the metal core or all ceramic post and core. This study was performed to evaluate effect on color of Empress 2 crown according to various post systems. Color was evaluated by the CIE $L^*a^*b^*$ systems and measured by spectrophotometer (Model CM-3500, Minolta, Japan). Specimens were divided into 4 groups as follows Group 1 : gold cast post specimen + Empress 2 crown specimen Group 2 : application of an opaque porcelain to gold cast post specimen + Empress 2 crown specimen Group 3 : cosmopost specimen + Empress 2 crown specimen Group 4 : In-ceram post specimen + Empress 2 crown specimen. The results obtained as follows, 1. $L^*$ Values showed that group 2, 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 2. $a^*$ Values and $b^*$ values also showed that group 2. 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 3. ${\Delta}E^* ab$ Values showed that ${\Delta}E^* ab$ 3 was the highest value and ${\Delta}E^* ab$ 5 was the lowest value.

  • PDF

Discrimination between FRC-post and core according to the color difference (색상차이에 따른 FRC-포스트와 코어 사이의 구별)

  • Kim, Jou-Hwe;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.75-85
    • /
    • 2015
  • Purpose: The purpose of this study is to evaluate which FRC-posts were more distinguishable from core. Materials and Methods: Nine extracted single-rooted mandibular premolars with similar lengths (${\pm}0.5 mm$) and widths (${\pm}0.5 mm$) were endodontically treated and obturated. One specimen which the three roots were embedded in a cold mounting resin was made. 3 specimens were made by this method. Post spaces were prepared for the following post system: FRC $Postec^{(R)}$ Plus, MACRO-$LOCK^{TM}$ POST $ILLUSION^{TM}$ $XRO^{(R)}$, $Snowpost^{(R)}$. After three different posts were placed in the roots of a specimen, each three specimens received a direct core build-up: $Luxacore^{(R)}$ Dual A3, $Luxacore^{(R)}$ Dual blue, $Filtek^{TM}$ Z350 A1E. Digital images were taken of the post and core with and without air-blowing. We asked to fifty dentists and fifty dental college students which post was more clearly discriminated from the core. Results: In surveys, when core was $Luxacore^{(R)}$ Dual blue, among three types of posts people more easily discriminated the $Snowpost^{(R)}$ from core. When core was $Luxacore^{(R)}$ Dual A3, among three types of posts people similarly more easily discriminated $Snowpost^{(R)}$ from core. When core was $Filtek^{TM}$ Z350 A1E, among three types of posts people more easily discriminated distinguished MACRO-$LOCK^{TM}$ POST $ILLUSION^{TM}$ $XRO^{(R)}$ post from core. People more easily distinguished MACRO-$LOCK^{TM}$ POST $ILLUSION^{TM}$ $XRO^{(R)}$ post from core when temperature was lowered by air-blowing. Conclusion: Ability to discriminate between FRC-post and core is different according to color contrast. MACRO-$LOCK^{TM}$ POST $ILLUSION^{TM}$ $XRO^{(R)}$ posts are more discriminable when temperature is lowered by air-blowing.

FINITE ELEMENT ANALYSIS OF MAXILLARY CENTRAL INCISORS RESTORED WITH VARIOUS POST-AND-CORE APPLICATIONS (여러가지 post-and-core로 수복된 상악 중절치의 유한요소법적 연구)

  • Seo, Min-Seock;Shon, Won-Jun;Lee, Woo-Cheol;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.324-332
    • /
    • 2009
  • The purpose of this study was to investigate the effect of rigidity of post core systems on stress distribution by the theoretical technique, finite element stress-analysis method. Three-dimensional finite element models simulating an endodontically treated maxillary central incisor restored with a zirconia ceramic crown were prepared and 1.5 mm ferrule height was provided. Each model contained cortical bone, trabecular bone, periodontal ligament, 4 mm apical root canal filling, and post-and-core. Six combinations of three parallel type post (zirconia ceramic, glass fiber, and stainless steel) and two core (Paracore and Tetric ceram) materials were evaluated, respectively. A 50 N static occlusal load was applied to the palatal surface of the crown with a $60^{\circ}$angle to the long axis of the tooth. The differences in stress transfer characteristics of the models were analyzed. von Mises stresses were chosen for presentation of results and maximum displacement and hydrostatic pressure were also calculated. An increase of the elastic modulus of the post material increased the stress, but shifted the maximum stress location from the dentin surface to the post material. Buccal side of cervical region (junction of core and crown) of the glass fiber post restored tooth was subjected to the highest stress concentration. Maximum von Mises stress in the remaining radicular tooth structure for low elastic modulus resin core (29.21 MPa) was slightly higher than that for high elastic modulus resin core (29.14 MPa) in case of glass fiber post. Maximum displacement of glass fiber post restored tooth was higher than that of zirconia ceramic or stainless steel post restored tooth.

OPTICAL EFFECTS OF NONMETALLIC POST AND CORE SYSTEMS ON ALL-CERAMIC CROWNS (비금속 포스트 코어가 전부도재관에 미치는 광학적인 영향)

  • Kim Sung-Won;Cho In-Ho;Lim Ju-Hwan;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.493-506
    • /
    • 2002
  • Recently as the esthetic concerns about dental prosthesis have been increased, the nonmetallic post and core systems have been introduced clinically to improve the color and the low optical transmittance of conventional casting metal post and core systems. The purpose of this study was to compare and analyze the optical transmittance and the shade changes of all-ceramic crowns with two nonmetallic post and core systems. The experimental groups were classified as follows : Total 27 specimens(9 samples in each group) were evaluated. Group I : Natural teeth as a control group Group II : CosmoPost and $Empress^{(R)}$ core (Ivoclar-Vivadent, Liechtenstein) Group III : $LIGHT-POST^{TM}$ and $LIGHT-CORE^{TM}$ (Bisco, U.S.A.) In all group, all-ceramic crowns were fabricated with the same shade of IPS $Empress^{(R)}$ II (Ivoclar-Vivadent, Liechtenstein) after abutment preparation, and then two kinds of spectrophotometers, UV 3101 PC (Shimadzu, Japan) and CM 503i (Minolta Co. Ltd. Japan), were used to measure the optical transmittance and the color value. The following results were obtained : 1. The optical transmittance of each group without all-ceramic crowns, was siginificantly decreased in order of Group III, I and II (p<0.05). 2. The optical transmittance of each group with all-ceramic crowns cemented, were siginificantly decreased in order of Group I, II and III (p<0.05). 3. In comparison with the shade of all-ceramic crowns, there were no significant differences between groups regardless of the cementation. 4. In comparison with the shade changes in each group after the cementation of all-ceramic crowns, there were no significant differences between groups. From the above results, it is thought that the selection among materials used in this study doesn't influence greatly the esthetic restoration, because the differences of optical transmittance were so small that those were clinically insignificant.

Fracture resistances of zirconia, cast Ni-Cr, and fiber-glass composite posts under all-ceramic crowns in endodontically treated premolars

  • Habibzadeh, Sareh;Rajati, Hamid Reza;Hajmiragha, Habib;Esmailzadeh, Shima;Kharazifard, Mohamadjavad
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.170-175
    • /
    • 2017
  • PURPOSE. The aim of the present study was to evaluate the fracture resistances of zirconia, cast nickel-chromium alloy (Ni-Cr), and fiber-composite post systems under all-ceramic crowns in endodontically treated mandibular first premolars. MATERIALS AND METHODS. A total of 36 extracted human mandibular premolars were selected, subjected to standard endodontic treatment, and divided into three groups (n=12) as follows: cast Ni-Cr post-and-core, one-piece custom-milled zirconia post-and-core, and prefabricated fiber-glass post with composite resin core. Each specimen had an all-ceramic crown with zirconia coping and was then loaded to failure using a universal testing machine at a cross-head speed of 0.5 mm/min, at an angle of 45 degrees to the long axis of the roots. Fracture resistance and modes of failure were analyzed. The significance of the results was assessed using analysis of variance (ANOVA) and Tukey honest significance difference (HSD) tests (${\alpha}=.05$). RESULTS. Fiber-glass posts with composite cores showed the highest fracture resistance values ($915.70{\pm}323N$), and the zirconia post system showed the lowest resistance ($435.34{\pm}220N$). The corresponding mean value for the Ni-Cr casting post and cores was reported as $780.59{\pm}270N$. The differences among the groups were statistically significant (P<.05) for the zirconia group, as tested by ANOVA and Tukey HSD tests. CONCLUSION. The fracture resistance of zirconia post-and-core systems was found to be significantly lower than those of fiber-glass and cast Ni-Cr post systems. Moreover, catastrophic and non-restorable fractures were more prevalent in teeth restored by zirconia posts.

Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crowns

  • Suputtamongkol, Kallaya;Tulapornchai, Chantana;Mamani, Jatuphol;Kamchatphai, Wannaporn;Thongpun, Noparat
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.319-325
    • /
    • 2013
  • PURPOSE. The objective of this study was to determine the effect of the color of a background substructure on the overall color of a zirconia-based all-ceramic crown. MATERIALS AND METHODS. Twenty one posterior zirconia crowns were made for twenty subjects. Seven premolar crowns and six molar crowns were cemented onto abutments with metal post and core in the first and second group. In the third group, eight molar crowns were cemented onto abutments with a prefabricated post and composite core build-up. The color measurements of all-ceramic crowns were made before try-in, before and after cementation. A repeated measure ANOVA was used for a statistical analysis of a color change of all-ceramic crowns at ${\alpha}$=.05. Twenty four zirconia specimens, with different core thicknesses (0.4-1 mm) were also prepared to obtain the contrast ratio of zirconia materials after veneering. RESULTS. $L^*$, $a^*$, and $b^*$ values of all-ceramic crowns cemented either on a metal cast post and core or on a prefabricated post did not show significant changes (P>.05). However, the slight color changes of zirconia crowns were detected and represented by ${\Delta}E{^*}_{ab}$ values, ranging from 1.2 to 3.1. The contrast ratios of zirconia specimens were 0.92-0.95 after veneering. CONCLUSION. No significant differences were observed between the $L^*$, $a^*$, and $b^*$ values of zirconia crowns cemented either on a metal cast post and core or a prefabricated post and composite core. However, the color of a background substructure could affect the overall color of posterior zirconia restorations with clinically recommended core thickness according to ${\Delta}E{^*}_{ab}$ values.

Comparative evaluation of effects of different surface treatment methods on bond strength between fiber post and composite core

  • Mosharraf, Ramin;Yazdi, Najmeh Baghaei
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.103-108
    • /
    • 2012
  • PURPOSE. Debonding of a composite resin core of the fiber post often occurs at the interface between these two materials. The aim of this study was to evaluate the effects of different surface treatment methods on bond strength between fiber posts and composite core. MATERIALS AND METHODS. Sixty-four fiber posts were picked in two groups (Hetco and Exacto). Each group was further divided into four subgroups using different surface treatments: 1) silanization; 2) sandblasting; 3) Treatment with 24% $H_2O_2$, and 4) no treatment (control group). A cylindrical plexiglass matrix was placed around the post and filled with the core resin composite. Specimens were stored in 5000 thermal cycles between $5^{\circ}C$ and $55^{\circ}C$. Tensile bond strength (TBS) test and evaluation using stereomicroscope were performed on the specimen and the data were analyzed using two-way ANOVA, Post Hoc Scheffe tests and Fisher's Exact Test (${\alpha}$=.05). RESULTS. There was a significant difference between the effect of different surface treatments on TBS ($P$ <.001) but different brands of post ($P$=.743) and interaction between the brand of post and surface treatment ($P$=.922) had no significant effect on TBS. Both silanization and sandblasting improved the bonding strength of fiber posts to composite resin core, but there were not any significant differences between these groups and control group. CONCLUSION. There was not any significant difference between two brands of fiber posts that had been used in this study. Although silanization and sandblasting can improve the TBS, there was not any significant differences between surface treatments used.

A STUDY FOR THE BONDING STRENGTH OF COMPOSITE RESIN CORE TO GLASS FIBER POST (Glass Fiber Post와 Composite Resin Core의 전단결합강도)

  • Kim Tae-Hyoung;Shim June-Sung;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.415-425
    • /
    • 2005
  • Statement of problem : Fracture of composite resin core will be occulted by progress of crack. Bonding interface of different materials has large possibility of starting point of crack line. Therefore, the bond strength of glass fiber post to composite resin core is important for prevention of fracture. Purpose: This in vitro study tried to find out how to get the higher strength of glass fiber post to composite resin core through surveying the maximum load that fractures the post and cote complex. Materials and methods: 40 specimens made with glass fiber Posts(Style $post^{(R)}$, Metalor, Swiss) and composite resin core ($Z-100^{(R)}$, 3M, USA) were prepared and loaded to failure with push-out type shear-bond strength test in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with four different surface treatments. With the data. ANOVA test was used to validate the significance between the test groups, and Bonferroni method was used to check if there is any significant statistical difference between each test group. Evely analysis was approved with 95% reliance. Results: On measuring the maximum fracture load of specimens, both the treatments of sandblasted and acid-etched one statistically showed the strength increase rather than the control group (p<0.005). The scanning electric microscope revealed that sand blasting made more micro-retention form not only on the resin matrix but on the glass fiber, and acid-etching contributed to increase in surface retention form, eliminated the inorganic particles in resin matrix. Specimen fracture modes investigation represented that sand blasted groups showed lower bonding failure than no-sand blasted groups. Conclusion: Referring to the values of maximum fracture load of specimens, the bonding strength was increased by sand blasting and acid-etching.

Traditional approach with ceramic (임상가를 위한 특집 2 - 심미 수복 - 같은 결과, 다른 접근 세라믹을 이용한 전통적인 접근법)

  • Lee, Seung-Kyu
    • The Journal of the Korean dental association
    • /
    • v.51 no.11
    • /
    • pp.595-603
    • /
    • 2013
  • The requirements for the successful treatment of all-ceramic restorations are not so different from the ones of conventional restorations. "The provisional restoration followed by an adequate tooth reduction and the accurately fitting prostheses with corresponding to final impression" can be the examples of them. Nevertheless, the one which all-ceramic restorations are distinguished from conventional restorations is the additional procedure of so called "bonding". In addition to the application of resin cement between "inner surface of restoration and outer surface of abutment", bonding technology can be also applied to the treatment process of "Post and Core" in particular if the abutments are non-vital teeth. Core build-up for all-ceramic crown is conducted with fiber post and tooth colored composite by considering the properties of the restorations transmitting light. We know well that a vital abutment is easier than a non-vital one to get the targeted goals for clinical success in connection with esthetics and structure. The creation of "Post and Core" with bonding technique is a decisive factor for a long-term success if the abutment is non-vital tooth with dentinal collapse. I would like to share my clinical experience about "post & core build-up and all-ceramic restoration bonding" out of several success strategies of all-ceramic crown with this presentation.

A STUDY ON THE ADAPTATION OF THE CAST POST (주조 포오스트의 적합도에 관한 연구)

  • Park, Dong-Kwan;Chang, Ik-Tai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.55-65
    • /
    • 1986
  • An in vitro study was performed to evaluate adaptation of custom direct, custom indirect, and prefabricated post system on 15 extracted upper central incisors. 15 specimens were prepared and equally devided into 3 groups under random sampling. Each group of 5 cast posts was made with custom direct, custom indirect, and prefabricated post core method. Gap between inner wall of the dentin and outer wall of the cast post was measured on electron microphotographic prints at x500 magnification. The result were as follows ; 1. No significant difference of adaptation at cervical portion was found between each method. 2. Prefabricated post core method had poor adaptation compared with other methods. 3. Even distribution of adaptation was found in custom direct method between each portion. 4. Prefabricated post core method showed remarkable difference in adaptation between each portion.

  • PDF